Loading...
HomeMy WebLinkAbout25.363 - Title 5 Site PlanACCESS COVERS TO WITHIN 6" OF FIN. GRADE 12.8' SYSTEM PROFILE ALL SYSTEM COMPONENTS SHALL BE (NOT TO SCALE) MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 2" PEASTONE OR GEOTEXTILE PROVIDE INSPECTION PORTS TO FILTER FABRIC OVER STONE WITHIN 3" OF FINISH GRADE 1 2% SLOPE REQUIRED OVER SYSTEM/2' PRECAST H-10 RISERS (TYP.) 2'e 4"OSCH40 PVC JEQUAL) PIPES LEVEL 1ST 2' 10.6*'f 10" 1500 GAL 1OTEE SEPTIC TA9 95, °°°°°°°°°4' LI0. LEVEL (ACM9.65' 9.48' �Oo°o°o°o°o°o°o°o°°o°o o° �0000000�o„o�o 10°00000000° 0 0�0�0„0�0°00000. 6" CRUSHED STONE OR MECHANICAL (1_7% SLOPE) COMPACTION. (15.221 [21) (-L% % SLOPE) (-L-% SLOPE) FOUNDATION- 24' - SEPTIC TANK 30' D' BOX 7' - *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEN D- 99- 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. F-99-1 METER 3,0' PROPOSED CONTOUR 99 PROPOSED SPOT EL. TH1 TEST HOLE, 2>= SLOPE OF GROUND GARAGE UTILITY POLE ZX FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR M DRAWING TEST HOLE LOGS ENGINEER: ARNE H. OJALA, PE, PLS WITNESS: AMY VON HONE, RS DATE: JULY 29, 2009 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS Q ELEV. i 0" 12.0' 15" FILL AD LS 16" 1OYR 2/1 E FS 19"1 2.5Y 5/2 B LS 48" 1OYR 5/8 8.0' PERC MS 2.5Y 6/4 120 OBS WATER 2.0' 09-175 GROUNDWATER ADJ. DATA: WELL: MIW 29 ZONE: A ADJ: 1.6' +1a00 9.78 9.68 92 11.58 1 11.51 1029 Yp 11.43 2" DOUBLE 9.93' HIGH CAPACITY QUICK 4 INFILTRATORS 3/4" TO 1 1/2" DOUB-E WASHED STONE OVERALL DIMENSIONS TO OUTSIDE OF STONE: 47' X 10.83' 5.0' LEACHING FACILITY USE ADJ. G -W AT EL. 3.6' M CAUTION: GASUNE IS IN AREA OF GUY SOIL REMOVAL Lti T-�LE _p1PPER _- 143.59' 11.76 i PAVED 13 793 SF +1 31 DRI Iw �1 PAVED 1 I ` 11.68 1 DRIVE 71.95 1.11.76 I /1. 29 } 1 w 1 12.15 JC14,� 2 FLAGPOLE 1 W . 6- 1 90 NN E)11,28 i 1 / EXISTING 11 W +1t25 }-I 16 DWELLING 1 - +12.46 TOP FNDN. ELEV. = 12.8' 5 12. NOTES 1. DATUM IS APPROX. NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q, 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR' CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. WATER TEST D'BOX FOR LEVELNESS LOCUS MAP NOT TO SCALE ASSESSORS MAP 25 PARCEL 363 LOCUS IS WITHIN FEMA FLOOD ZONE "B" AS SHOWN ON COMMUNITY PANEL#250015 0006D DATED REV. JULY 2, 1992 VARIANCE REQUESTED UNDER MFC, 15.405: 1(b): REDUCTION IN SETBACK, SAS TO FNDN. (20' TO 13') WIRE SYSTEM DESIGN" -}-4235 GAS t') l METER 3,0' INVERT OUT 10.6'1 .80 1 1 0 12.15 GARAGE 11 217-{-12.06 -1-11 20 SCREEN 11 PORCH 1 12.2 1 ON TUBES 1 1 12.2 1 1 1 SHWR _ DECK 1 - , % _ � 1 / +11.0 �2-b3-2 l CP --- -j' 11.92 N " _ fl[ y� T35 + 1.88 +1 a 1 +1 3� In 78.00' 81.87' - C6 BENCHMARK 11.74 COR. CONIC. BULKHEAD ELEV. = 12.2' NOT: PROPOSED MASTER BEDROOM SUITE OVER GARAGE (NO NET CHANGE IN # BEDROOMS; NO CHANGE IN FOOTPRINT) Scale: 1"= 20' 0 10 20 30 40 50 FEET 79 Ci/ZZ Jr,n q -z? -05 DATE NOTE: CONNECT UNITS VIA " 4' PVC GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW (EXIST 4 BR DWELL, STAYING 4 BEDROOMS TOTAL AFTER RENOVATION 5' REMOVAL OF UNSUITABLE SOIL REQUIRED SEPTIC TANK: 440 GPD (2) = 880 AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE USE A 1500 GAL. SEPTIC TANK WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) LEACHING: 11.86 PERIMETER: 115 (0.83) (0.74) = 70.6 GPD O0 0 BOTTOM AREA: 508 SF (0.74) = 375.9 GPD o TOTAL: 603.4 S.F. 446.5 GPD USE (11) H-20 QUICK 4 HIGH CAPACITY INFILTRATORS WITH 1.5' STONE AT ENDS AND 4' AT SIDES IN "L" 1 CONFIGURATION PROVIDE APPROX. 58' OF 40 MIL LINER AT 5' OFF SAS IN AREA SHOWN. TOP AT ELEV. 10', BOTTOM AT EL 6.0'1 y:0 , MA 64 APPROVED DATE BOARD OF HEALTH PermitONLY va valid for REPAIR OF SEPTIC SYSTE ONLYM TITLE 5 SITE PLAN , due to Stzle and I;oca! septic riances. Coard of flealai rcvi w and approval is required OF fcr any future additions/renos'ations/alterations to sewage facilities and/or structurtVdwelling. Yarmouth Health Department 48 LITTLE DIPPER LANE S'�9,zeMPPROVEU SOUTH YARMOUTH L%�JC/1G /0 PREPARED FOR PETER KILMARTIN e SEPTEMBER 22, 2009 SNA inp�sq �v,} off 508-362-4541 6� I fox 508-362-9880 downcope.com ti0' aL`' down cope engineefiMg, inc, �S$ p`swAL �r, gn9.A v civil engineers s NAL ?� land surveyors 939 Main Street ( Rte 6A) DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 09-175.DwG(SBO)