HomeMy WebLinkAbout149.66 - Proposed Septic Design (2)i 20 FT. MINIMUM FROM CELLAR 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE CONCRETE $¢rUi,J,Q 4-SCHEDULE PITCH 1 40 VC PIPE ��>,� ZABEL A100 FILTER TEE / f min. i t (.9. 2 0• r LEVEL BA AF FSE ELEV. _ _ 7,11 6" SUMP ELEV � LL DISTRIBUTION ELEV. _ BOX f.9, (TO BE PLACED ON FIRMBASE) TO BE WATER TESTED 500 GALLON IF MORE THAN ONE OUTLET SEPTIC TANK (TO BE PLACED ON FIRM BASE) 3/4" TO 1 1/2"-) WASHED STONE SEWAGE DISPOSAL SYSTEM PROFILE NOT TO SCALE s CLEAN SAND LOAM AND SEED \.lHED " LAYE,T OF /8 TO 1/2" MINIMUMASTONE VENT O,j v 1 CU. FT. OF CONCRETE ANCHOR , D ao ELEV. �;,�HIGH CAPACCIITY I It LATRATORS 151T�i D 36 X _?k X 10" FIELD FORMATION K WELL SDW 252 SOIL ABSORPTION ZONE A '* INDEX 47.3 SYSTEM (SAS) ADJUST 1.4 USGS PROBABLE WATER TABLE ELEV. =2.9 y Fc 1V•3 OBSERVED WATER TABLE ( 9 / 24 / 97 ) ELEV. _is/z6/� r°� --- BOTTOM OF TEST HOLE ELEV. = 0.5 ,l/ YENr �~ D. Box 1500 GALLON SEPTIC TANK f v T C'6I b�, % '� "r�, / 000 _ Ir ARAy �0 1y 1IL LOT 15 18,57 S.F.f / G� h fry6, / CATCH \SIN :?o = 6 5t5' 29'�O / RIM = 13.48 S BM PK NAIL r ELEV. = 14.72 fo,L T� 70 �� D Iv�3fo�� ZY' G<A'' 1w" 1 LV6" CLwr P�c.lG� 6✓finn �r AS8 70 f udSa'� CLa, d pt-'Jy- W r 4, `f c2 23 SOIL TEST DATE OF SOIL TEST$���1997 SOIL TEST DONE BY �R N G WITNESSED BY��URPH OBSERVATION HOLE 1 ELEV-- 16.0 OBSERVATION HOLE 2 ELEV.. 18.3 PERCOLATION RATE < 16 MIN./INCH AT 46 INCHES PERCOLATION RATE < 9 MIN./INCH AT 42 INCHES DEPTH HORIZ I TEXTURE COLOR MOTT. OTHER 0-9 0/A SANDY LOAM 10583/3 ROOTS 9-33 B LOAMY SAND 10`iR5/6 SWEETSER ENGINEERING 235 GREAT WESTERN ROAD P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 ROOTS 33-72 Cl SILT LOAM 10YR6/2 REVISED /1 TIGHT 72-15 C2 SILT CLAY LOAM 5GY TICHT DEPTH HORIZ TEXTURE COLOR MOTT. I OTHER 0-11 0/A SANDY LOAM 10YR3/2 ROOTS 11-26 8 LOAMY SAND 101 SWEETSER ENGINEERING 235 GREAT WESTERN ROAD P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 ROOTS 26-38 Cl FINE SAND 10YR6/4 REVISED /1 REVISED/7 36-108 C2 SILT LOAM 10YR6/2 TICHT loa-13f C3 SIL CLY 5GY NO WATER ENCOUNTERED AT 15V ELEV. - 4.3 NO WATER ENCOUNTERED AT 138" ELEV. - La OBSERVATION HOLE 3 ELEV- 15.5 OBSERVATION HOLE 4 ELEV.— 15.9 PERCOLATION RATE < 15 I/IN./INCH AT 41 INCHES PERCOLATION RATE < 3 MIN./INCH AT 44 INCHES PERCOLATION RATE < 7 MIN./INCH AT 70 INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-10 0/A SANDY LOAM 10YR3/2 PROJECT LOCATION LOT 5 125LOCH RANNOCH WAY, YAR. 10-30 B LOAMY SAND 10486/3 SWEETSER ENGINEERING 235 GREAT WESTERN ROAD P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 30-42 Cl FINE SAND 10YRII REVISED /1 REVISED/7 42-102 C2 SILT LOAM 10YR6/2 02-16 C3 SILTLOAN CLAY 50Y WATER ENCOUNTERED AT 168_ ELEV. - 1.5 DEPTH HORIZ I TEXTURE COLOR MOTT. OTHER 0-10 0/A SANDY LOAM 10YR3/2 PROJECT LOCATION LOT 5 125LOCH RANNOCH WAY, YAR. 10-30 B LOAMY SAND 10YR5/8 SWEETSER ENGINEERING 235 GREAT WESTERN ROAD P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 30-51 Cl FINE SAND 10YR6/3 REVISED /1 REVISED/7 51-100 C2 SILT LOAM t0YR6/2 *O -15c C3 SILOAM CLAY 50Y NO WATER ENCOUNTERED AT 150" ELEV. a 3.4 DESIGN CALCULATIONS NOTES: NUMBER OF BEDPOOVS 4 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. GARBAGE DISPOSAL UN;l �``� TITLE 5 AND THE TOWN OF YARMOUTH RULES AND Ti1TAi FST'#d ^ ^ ^:{}:+' _--- REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. ( 110 GAL/BR./DAY X 4 BR.) 44C GAL_IDAY 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO REQUIRED SEPTIC TANK CAPACITY 880 GAL WITHIN 6" OF FINISHED GRADE. ACTUAL SIZE OF SEPTIC TANK 1500 GAL 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF SOIL CLASSIFICATION --IIS WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN DESIGN PERCOLATION RATE < 20 MIN.%IN. 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE EFFLUENT LOADING RATE 0.34 GAL/DAY/S.F. USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. LEArHING AREA 1256 SO. FT. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL 2L X 3(o BE MORTARED IN PLACE. LEACHING CAPACITY (AREA X RATE) Y-0 G GAL/DAY 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH rZ9�, X 0.34 DEEDED OR ZONING REGULATIONS. OWNER /� APPLICANT 1S TO RESERVE LEACHING CAPACITY �' GAL/DAY OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG—SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. PARCEL IS IN FLOOD ZONE C. 8. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM. 9. ALL DISTURBED AREAS ARE TO BE REVEGETATED, 10. DESIGN ENGINEER AND HEALTH DEPARTMENT ARE TO INSPECT THE SEPTIC SYSTEM ON THE FOLLOWING SCHEDULE: A. SURVEYOR IS TO STAKE OVERDIG. B. ENGINEER IS TO INSPECT OVERDIG PRIOR TO FILLING. C: ENGINEER IS TO INSPECT PLACEMENT OF SEP11C COMPONENTS PRIOR TO BACKFILLING. 11. DESIGN ENGINEER IS TO CERTIFY INSTALLATION OF SEPTIC SYSTEM IN ACCORDANCE WITH THIS PLAN. 12. SEPTIC TANK AND DISTRIBUTION BOX ARE TO BE SET ON A 6" BED OF 3/4" TO 1 1/2" STONE. T. A. 13. LOT IS SHOWN ON ASSESSORS MAP 132 AS PARCEL S5 14. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS No.ti S17E CONDITIONS PRIOR TO COMMENCING WORK ON SITE. LEGEND: EXISTING SPOT ELEVATION 00X0 EXISTING CONTOUR----OO---- FTNAL SPOT ELEVATION FINAL CONTOUR 00 SOIL TEST LOCATION U71UTY POLE - >- TOWN WATER —W—=—W CATCH BASIN (®) GAS UNE G APPROVED: BOARD OF HEALTH DATE AGENT w wvul7/ LOCUS 0 t/7 o 0 Lo = RANNO� Z, w� cel a PROPOSED SEPTIC DESIGN FOR DAVID & BARBARA CLANCY PROJECT LOCATION LOT 5 125LOCH RANNOCH WAY, YAR. SWEETSER ENGINEERING 235 GREAT WESTERN ROAD P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 scALE 1" = 20' DATE DEC. 11, 1997 REVISED /1 REVISED/7 LOCATION MAP JOB N0• •40326 SHEET OF 1