HomeMy WebLinkAbout151.90 - Site and Sewage Plan (2)a a
,°
o0,
fi
O G� U)
�? s
DATUM:
VERTICAL DATUM: ASSUMED
BENCH MARK USED: TOP OF CONCRETE BOUND
AT NORTHWEST CORNER
OF LOCUS.
ELEVATION 40.00
SYSTEM PROFILE:
NOT TO SCALE
TOP OF FOUNDATION
ELEV, 43.3
FINISH GRADE FINISH GRADE
RAISE COVERS TO WITHIN 6" OF FINISH GRADE
CENTER CHAMBER RISER
RAISE TO WITHIN 6"
i IA/AP POST
C) - SYR uss
w
57bWC 44fM0'A//A/& WAZ4
eRPCK u/Ark
ziDATE: 11/18/02 DATE: 11/18/02
GROUND ELEV 35.5 GROUND ELEV 34.6 \ .
NO GROUNDWATER NO GROUNDWATER k'
A/0 A/0
SANDY LOAM SANDY LOAM
10YR 3/3 10YR 3/3
B B
SANDY LOAM SANDY LOAM
10YR 5/8 10YR 5/8
C-1
SILT LOAM
2.5Y 6/6 C-1
.ELEV = 30.0 SILT LOAM
2.5Y 6/6
C-2 ELEV = 26.1
[:2
NE LOAM C-2
SAND MED. SAND
.5Y 7/4 2.5Y 7/4
0
4"
38"
Cd -1
66"
840"
0 BENCHMARK
TOP OF CONCRETE BOUND
ELEVATION 40.00 n J
4"
40.E \� \
32.. Q 4 �oF O Oy�d z
. .. \ N� O
WOODWARD / / i \ ` \ �.\ ss40
2' y / \ \ F �bgYJ / \
102" ASSESSORS MAP 151 / 4 \ .� F �\ V� \
PARCEL 91�\ \
#11 LONGFELLOW DRIVE \ ? Ni \
150" / / 10' \ \ GHQ \ \ \
,VV
ELEV 24.0 ELEV = 22.1 ! v MIN. ` a \ RO R-4
B.O.H. B.O.H.110
\
AMY VON HONE AMY VON HONE
SOIL EVALUATOR'. SOIL EVALUATOR -
ED. STONE ED. STONE
BACKHOE OPERATOR. / oC15 0 \ \ ,� \\ \ 7.68, \ \
£LLIS BROTHERS
SOIL TYPE 1_
FERC RATE. 3 -MIN, PER INCH / 2 ~ t\
LOADING RATE: 0_74, GAL/SF/MIN
ah o !/ 20 PROPOSED � �� � ��� �� � �� �� �� - •
INDICATES DEEP ,^. ! opt),-; DTH #2 12.83'x25.0'
DTH #2 TEST HOLE �o� 0 12. 0 RESERVE \ \ ` 40 \� \
0 1 AREA
INDICATES\ \ \
P -1A 44" PERC TEST �'PROPOSED)
/ b -
/ PROPOSED 24' x 22' y �2' 500 GAL
2 .9) / GARAGE (SLAB 42.0) y Q SEP. TANK DTH # 1 \\ \ \ \ \ \ \ k
\\
GENERAL NOTES: (
\ PROPOSED
1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. \ 4� 26' x 36' o
\ \ \
TITLE V AND THE TOWN OF- YARMOUTH RULES AND REGULATIONS O _ 3 BEDROOM ' ! / ) \\ \ co� \ !
FOR SUBSURFACE DISPOSAL OF SEWERAGE. I DWELLING
2: AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE BASEMENT SLAB 35.5
TOP OF FND. REAR 36.0
" WITH ANY REMAINING I TOP OF FND. FRONT. 43.3 / /! !! • \\ \ /1 // ! \
ACCESSIBLE WITHIN 6" OF FINISH GRADE, � >
ACCESS ,PORTS BROUGHT TO WITHIN 12 OF FINISH GRADE.
3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE
3�0 PROPOSED
CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE
UNDER OR WITHIN 16 OF DRIVES OR 'PARKING AREAS THEY
• CONCRETE BOUND I DECK
�
MUST WITHSTAND H-20 LOADING. DH FOUND
4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION
OF ALL'UTILITIES PRIOR TO ANY EXCAVATION.
5:; ANY MASONRY UNITS USED TO BRING COVERS TO GRADE
OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE.
6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER
FOOT OVER.THE S.A.S. AND DISTRIBUTION BOX. �1� �/ / / !� v /
7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF 1" 20,2 I / !/ // / �p /! yh/1���
SCHEDULE 40 PVC AND SHALL EXTEND A•MINIMUM OF 6" ABOVE. �� 343 /
PRO SED K !
THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND STONE ATIO / / / ! / / / / . 9 / QQ
LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. �� 3SD ! / / / / / ///� / /OF
8. THE INLET PIPEINVERT ELEVATION SHALL BE NO LESS THAN
30.2'
2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT
ELEVATION OF THE OUTLET PIPE.
9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES - 0 W 1-4,5101, ~ �3�4
10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS v
BAFFLE 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC / /foo, / / ! ! / /
11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND �� ` \��` �. \ / 60.5' / / // 6. oh /// // //�!/! ! CATCH S
SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE // / // / y'��! / ! / ! BASIN �P
FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL
BE LEVEL
12, CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION MORE
TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW ASSESSORS MAP 151
/ l
AND APPROVAL:
PARCEL 89
#4 BAYRIDGE DRIVE
CONSTRUCTION NOTES:
1. CONTRACTORS INSTALLERS SHALL VERIFY GRADES AND
ELEVATIONS AND ,SITE CONDITIONS PRIOR TO COMMENCING 39 - _ _ L_ P�
WORK ON THE SITE: ARE BOUND ////// /
/ SUPPORT POLE --_
2. NO DETERMINATION''HAS BEEN MADE AS TO COMPLIANCE _--- - -� - _ ' FOUND / // / / / 35/311
SYSTEM DESIGN
DESIGN FLOW
3 BEDROOMS AT 110 GPB/D 332 GPD
REQUIRED SEPTIC TANK
330 x_2 __ = ----- 660 GAL.
SEPTIC TANK PROVIDED = _ 1500 _GAL.
SIZE OF LEACHING FACILITY REQUIRED
DESIGN PERC RATE c2 _ --MIN./INCH
LONG TERM APPL. RATE_0.74_GPD/S.F.
SIZE OF LEACHING SYSTEM PROVIDED:
330 + 0.74 SF/GPD = 446 S.F. MIN. REQUIRED
USING 3 CHAMBERS WITH 4' STONE AROUND
SIDEWALL = 2(12.83+25.0') x 2 = 151.3S.F.
BOTTOM = 12.83' x 25.0" = 320.7S.F.
TOTAL LEACHING AREA = 472S.F.
472 S.F x 0.74 = 349 GPD
349 GPD PROVIDED > 330 GPD REQUIRED = 19 GPD RESERVE
NO GARBAGE DISPOSAL / GRINDER ALLOWED
LOCUS INFORMATION
CURRENT OWNER
RICHARD W. MORGAN, Jr.
ADDRESS
1 LONGFELLOW DRIVE
ELEV. 42.0
YARMOUTHPORT
ELEV. 41.6
MA 02675
FINISH GRADE OF FINISH GRADE
PLAN BOOK 203, PAGE 111
TITLE REFERENCE
DEED BOOK 6868, PAGE 092
ZONING DISTRICT
R-40
SETBACKS
FRONT 30'
SIDE 20'
ELEV.
40.9 GROUND
ELEVATION 40.5
C
ASSESSORS MAP
151
PARCEL
90
`."
10'CS=0.0251
MIN. -3'
MAX. COVER
,p
4'®S=0.015
12'®S=-0.001
TOP ELEV 39.87
6A`
4"
-„ --„--
4" PVC SCH
40
O O O o o O 00
2" MIN 1/8"-1/4" DOUBLE WASHED PEA STONE
'p
SCH 40
INV.=
2 Mi -3 MAX
O O O O
n,
°�
:<
INV,= 40.0
39.75
10"TEE
14"TEE
INV.=39.50
00000 0 0 00000
1
�,
O 000 000 0 00 000 0
3/4" DOUBLE WASHED STONE
Oa6"
5-7
GAS BAFFLE
5 OUTLET
0 3),
2
9 2
4'-62
4'-1" LIQUID LEVEL
D -BOX
TWO 4' -10"x8' -6"x2'-9" CHAMBERS
S
4'14"
INV.=39.44
WITH 4' OF STONE AROUND
NV.=39.12 p..
(POUT AROUND SYSTEM TO "C-2" (MEDIUM SAND) HORIZON MIN DEPTH
G
ELEV
INV�39.24
or
1L
37.12
35.2
S.A.S. (12.83' x 25.0')
d
STRIPOUT (23'± x 35.0')
LOCUS MAP
6" BASE OF CRUSHED STONE
NOT TO SCALE:
OR MECHANICALLY COMPACTED
TEST PIT
#2 ELEV 22.1 NO GROUNDWATER ENCOUNTERED
1,500 GALLON
PRECAST CONCRETE
-
SEPTIC TANK
D.T.H. #1 ib D.T,H. #2
ziDATE: 11/18/02 DATE: 11/18/02
GROUND ELEV 35.5 GROUND ELEV 34.6 \ .
NO GROUNDWATER NO GROUNDWATER k'
A/0 A/0
SANDY LOAM SANDY LOAM
10YR 3/3 10YR 3/3
B B
SANDY LOAM SANDY LOAM
10YR 5/8 10YR 5/8
C-1
SILT LOAM
2.5Y 6/6 C-1
.ELEV = 30.0 SILT LOAM
2.5Y 6/6
C-2 ELEV = 26.1
[:2
NE LOAM C-2
SAND MED. SAND
.5Y 7/4 2.5Y 7/4
0
4"
38"
Cd -1
66"
840"
0 BENCHMARK
TOP OF CONCRETE BOUND
ELEVATION 40.00 n J
4"
40.E \� \
32.. Q 4 �oF O Oy�d z
. .. \ N� O
WOODWARD / / i \ ` \ �.\ ss40
2' y / \ \ F �bgYJ / \
102" ASSESSORS MAP 151 / 4 \ .� F �\ V� \
PARCEL 91�\ \
#11 LONGFELLOW DRIVE \ ? Ni \
150" / / 10' \ \ GHQ \ \ \
,VV
ELEV 24.0 ELEV = 22.1 ! v MIN. ` a \ RO R-4
B.O.H. B.O.H.110
\
AMY VON HONE AMY VON HONE
SOIL EVALUATOR'. SOIL EVALUATOR -
ED. STONE ED. STONE
BACKHOE OPERATOR. / oC15 0 \ \ ,� \\ \ 7.68, \ \
£LLIS BROTHERS
SOIL TYPE 1_
FERC RATE. 3 -MIN, PER INCH / 2 ~ t\
LOADING RATE: 0_74, GAL/SF/MIN
ah o !/ 20 PROPOSED � �� � ��� �� � �� �� �� - •
INDICATES DEEP ,^. ! opt),-; DTH #2 12.83'x25.0'
DTH #2 TEST HOLE �o� 0 12. 0 RESERVE \ \ ` 40 \� \
0 1 AREA
INDICATES\ \ \
P -1A 44" PERC TEST �'PROPOSED)
/ b -
/ PROPOSED 24' x 22' y �2' 500 GAL
2 .9) / GARAGE (SLAB 42.0) y Q SEP. TANK DTH # 1 \\ \ \ \ \ \ \ k
\\
GENERAL NOTES: (
\ PROPOSED
1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. \ 4� 26' x 36' o
\ \ \
TITLE V AND THE TOWN OF- YARMOUTH RULES AND REGULATIONS O _ 3 BEDROOM ' ! / ) \\ \ co� \ !
FOR SUBSURFACE DISPOSAL OF SEWERAGE. I DWELLING
2: AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE BASEMENT SLAB 35.5
TOP OF FND. REAR 36.0
" WITH ANY REMAINING I TOP OF FND. FRONT. 43.3 / /! !! • \\ \ /1 // ! \
ACCESSIBLE WITHIN 6" OF FINISH GRADE, � >
ACCESS ,PORTS BROUGHT TO WITHIN 12 OF FINISH GRADE.
3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE
3�0 PROPOSED
CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE
UNDER OR WITHIN 16 OF DRIVES OR 'PARKING AREAS THEY
• CONCRETE BOUND I DECK
�
MUST WITHSTAND H-20 LOADING. DH FOUND
4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION
OF ALL'UTILITIES PRIOR TO ANY EXCAVATION.
5:; ANY MASONRY UNITS USED TO BRING COVERS TO GRADE
OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE.
6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER
FOOT OVER.THE S.A.S. AND DISTRIBUTION BOX. �1� �/ / / !� v /
7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF 1" 20,2 I / !/ // / �p /! yh/1���
SCHEDULE 40 PVC AND SHALL EXTEND A•MINIMUM OF 6" ABOVE. �� 343 /
PRO SED K !
THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND STONE ATIO / / / ! / / / / . 9 / QQ
LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. �� 3SD ! / / / / / ///� / /OF
8. THE INLET PIPEINVERT ELEVATION SHALL BE NO LESS THAN
30.2'
2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT
ELEVATION OF THE OUTLET PIPE.
9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES - 0 W 1-4,5101, ~ �3�4
10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS v
BAFFLE 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC / /foo, / / ! ! / /
11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND �� ` \��` �. \ / 60.5' / / // 6. oh /// // //�!/! ! CATCH S
SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE // / // / y'��! / ! / ! BASIN �P
FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL
BE LEVEL
12, CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION MORE
TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW ASSESSORS MAP 151
/ l
AND APPROVAL:
PARCEL 89
#4 BAYRIDGE DRIVE
CONSTRUCTION NOTES:
1. CONTRACTORS INSTALLERS SHALL VERIFY GRADES AND
ELEVATIONS AND ,SITE CONDITIONS PRIOR TO COMMENCING 39 - _ _ L_ P�
WORK ON THE SITE: ARE BOUND ////// /
/ SUPPORT POLE --_
2. NO DETERMINATION''HAS BEEN MADE AS TO COMPLIANCE _--- - -� - _ ' FOUND / // / / / 35/311
SYSTEM DESIGN
DESIGN FLOW
3 BEDROOMS AT 110 GPB/D 332 GPD
REQUIRED SEPTIC TANK
330 x_2 __ = ----- 660 GAL.
SEPTIC TANK PROVIDED = _ 1500 _GAL.
SIZE OF LEACHING FACILITY REQUIRED
DESIGN PERC RATE c2 _ --MIN./INCH
LONG TERM APPL. RATE_0.74_GPD/S.F.
SIZE OF LEACHING SYSTEM PROVIDED:
330 + 0.74 SF/GPD = 446 S.F. MIN. REQUIRED
USING 3 CHAMBERS WITH 4' STONE AROUND
SIDEWALL = 2(12.83+25.0') x 2 = 151.3S.F.
BOTTOM = 12.83' x 25.0" = 320.7S.F.
TOTAL LEACHING AREA = 472S.F.
472 S.F x 0.74 = 349 GPD
349 GPD PROVIDED > 330 GPD REQUIRED = 19 GPD RESERVE
NO GARBAGE DISPOSAL / GRINDER ALLOWED
LOCUS INFORMATION
CURRENT OWNER
RICHARD W. MORGAN, Jr.
ADDRESS
1 LONGFELLOW DRIVE
YARMOUTHPORT
MA 02675
PLAN REFERENCE
PLAN BOOK 203, PAGE 111
TITLE REFERENCE
DEED BOOK 6868, PAGE 092
ZONING DISTRICT
R-40
SETBACKS
FRONT 30'
SIDE 20'
REAR 20'
FLOOD ZONE
C
ASSESSORS MAP
151
PARCEL
90
LOT AREA 15,781± S.F.
VARIANCE REQUESTED
/ TOWN OF YARMOUTH
TO ALLOW THE TOP OF FOUNDATION TO BE AT ELEVATION
43.5 IN LIEU OF THE 52.0 REQUIRED.
03 EB 13 AM 9:31
0 10 15 20 30 50
GRAPHIC SCALE: 1 INCH = 10 FEET
0
SITE AND SEWAGE PLAN
REPAIR / UPGRADE
#1 LONGFELLOW DRIVE
IN
YARMOUTH, MASSACHUSETTS
CALE 1" = 10' DATE: DEC. 9, 2002
WITH DEEDED OR ZONING REGULATIONS. OWNER' / APPLICANT �� �_ MHB/ // / / / // //� ��' ` �� UTILITY POLE
IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. - / / / / c�� altttAt� s
3. VEHICULAR TRAFFIC, PARKING OF VEHICLES AND PLACING 40 _ - - - - - FOUND 46.0/311 z1 0
MATERIALS OVER THE SEPTIC TANK, DISTRIBUTION BOX AND 41 ' - - - - - - _
/ / / �
S.A.S. AREA IS PROHIBITED 4r.. // /
BENCHMARK° �ofs yE
t4745 -//,HYDRANT FLANGE BOLT
- - - • / / 11// . /ti0 / ELEVATION 51.17
PREPARED FOR:
Mr. RICHARD W. MORGAN, Jr.
#1 LONGFELLOW DRIVE
YARMOUTHPORT
MA 02675 TILE PH^ D
0-4, PREPARED BY:
EAS SURVEY, INC.
141 RT. 6A
P.O. BOX 1729
RAONDWICH, MA 02563
,PH. (508) 888-3619
FAX (508) 888-2496
i�Eafa�l�
v�
v
A A ,r
STONE"C.
�9No 28980
// Now="
FI w