HomeMy WebLinkAbout151.102.1.1 - Foundation Plan780 CMR 3604.6 FOUNDATION WATERPROOFING AND DAMP PROOFING 3604.6.1 CONCRETE AND MASONRY FOUNDATION DAM PROOFING: EXCEPT WHERE REQUIRED TO BE WATERPROOFED BY 780 CMR 3604.6.2 FOUNDATION WALLS ENCLOSING HABITABLE OR STORAGE SPACE SHALL BE DAMP PROOFED FROM THE TOP OF THE FOOTING TO THE FINISHED GRADE. MASONRY WALLS SHALL BE DAMPROOFED BY APPLYING NOT LESS THAN 3/8" PORTLAND CEMENT PARGING TO THE EXTERIOR OF THE WALL. THE PARGING SHALL BE COVERED WITH A BITUMINOUS COATING, THREE POUNDS PER SQUARE YARD OF ACRYLIC MODIFIED CEMENT, 1/8—INCH COAT OF SURFACE BONDING MORTAR COMPLYING WITH ASTM C 887 OR ANY MATERIAL PERMITTED FOR WATERPROOFING IN 780 CMR 3604.6.2. CONCRETE WALLS SHALL BE DAMP PROOFED BY APPLYING ANY ONE OF THE WATERPROOFING MATERIALS LISTED IN 780 CMR 3604.6.2 TO THE EXTERIOR OF THE WALL, 3604.6.2 CONCRETE AND MASONRY FOUNDATION WATERPROOFING: IN AREAS WHERE A HIGH WATER TABLE OR OTHER SEVERE SOIL—WATER CONDITIONS ARE KNOWN TO EXIST, EXTERIOR FOUNDATION WALLS ENCLOSING HABITABLE OR STORAGE SPACE SHALL BE WATERPROOFED WITH A MEMBRANE EXTENDING FROM THE TOP OF THE FOOTING TO THE FINISHED GRADE. THE MEMBRANE SHALL CONSIST OF TWO—PLY HOT—MOPPED FELTS, 55 POUND ROLL ROOFING, 6 MIL POLYVINYL CHLORIDE, SIXIMIL POLYETHYLENE OR 40—MIL POLYMER—MODIFIED ASPHALT. THE JOINTS IN THE MEMBRANE SHALL BE LAPPED AND SEALED WITH AN ADHESIVE COMPATIBLE WITH THE WATERPROOFING MEMBRANE. TABLE 3604.2.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE TYPE OR LOCATION OF MINIMUM SPECIFIED CONCRETE CONSTRUCTION COMPPRESSIVE STRENGTHI (f'c) BASEMENT WALLS AND FOUNDATIONS 2 NOT EXPOSED TO THE WEATHER. 2,500 BASEMENT SLABS AND INTERIOR SLABS 2 ON GRADE,EXCEPT GARAGE FLOOR SLABS 2,500 BASEMENT WALLS,FOUNDATION WALLS, EXTERIOR WALLS AND OTHER VERTICAL 3 CONCRETE WORK EXPOSED TO THE WEATHER, 3,000 PORCHES,CARPORT SLABS AND STEPS 3,4 EXPOSED TO THE WEATHER,AND GARAGE 3,500 FLOOR SLABS I I FOR SI; 1 psi = 6.895 kPa 1. AT 28 DAYS psi. 2. CONCRETE IN THESE LOCATIONS WHICH MAY BE SUBJECT TO FREEZING AND THAWING DURING CONSTRUCTION SHALL BE AIR -ENTRAINED CONCRETE IN ACCORDANCE WITH FOOTNOTE 3. 3. CONCRETE SHALL BE AIR -ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL NOT BE LESS THAN 5% OR MORE THAN 7%. 4. SEE 780 CMR 3604.2.2 FOR MINIMUM CEMENT CONTENT. A 0 I LO N 780 CMR 3604.4 FOUNDATION WALLS 3604.4.1 CONCRETE AND MASONRY FOUNDATION WALLS: FOUNDATION WALLS SHALL BE CONSTRUCTED IN ACCORD NCE WITH THE PROVISIONS OF CMR 3604.4 OR IN ACCORDANCE WITH ACI 318, ACI 318.1, NCMA TR68—A OR ACI 530/ASCE 5/TMS 402 AS LISTED IN APPENDIX A OF THE MASSACHUSETTS BUILDING CODE, OR OTHER APPROVED STRUCTURAL SYSTEMS. 3604.4.1.1 MASONRY AND CONCRETE WALL CONSTRUCTION: MASONRY AND CONCRETE FOUNDATION WALLS SHALL BE CONSTRUCTED AS IN ACCORDANCE WITH TABLE 3604.4.1.1x. EXCEPTION: WHERE UNSTABLE SOIL CONDITIONS EXIST OR WHERE THE FOUNDATION EXTENDS TO OR BELOW THE SEASONAL HIGH GROUNDWATER TABLE, FOUNDATION WALL SHALL BE CONSTRUCTED IN ACCORDANCE WITH TABLE 3604.4.1.1b. 3604,4.1,2 DESIGN: FOUNDATION WALLS SUBJECT TO MORE PRESSUREE-THAN WOULD EXERTED BY BACKFILL HAVING AN EQUIVALENT FLUID WEIGHT OF 30 POUNDS PER CUBIC FOOT SHALL BE DESIGNED IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE BY A REGISTERED ENGINEER OR REGISTERED ARCHITECT 3604.4.1.3 GRADE CLEARANCE: FOUNDATION WALLS SHALL EXTEND AT LEAST EIGHT (8) INCHES ABOVE THE FINISHED GRADE ADJACENT TO THE THE FOUNDATION AT ALL POINTS. EXCEPTION: WHERE MASONRY VENEER IS USED, FOUNDATION WALLS SHALL EXTEND A MINIMUM OF FOUR INCHES ABOVE FINISHED GRADE. NOTES: 1. EXTERIOR FOOTINGS SHALL EXTEND TO BELOW THE FROSTLINE UNLESS OTHERWISE PROTECTED AGAINST FROST HEAVE. IN NO CASE SHALL EXTERIOR FOOTINGS BE LESS THAN 12 INCHES BELOW GRADE. 2. FOOTING WIDTHS(W) SHALL BE BASED ON THE LOAD—BEARING VALUE OF THE SOIL IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE. 3. SPREAD FOOTINGS SHALL BE A MINIMUM OF SIX INCHES THICK, AND FOOTING PROJECTIONS(P) SHALL BE A MINIMUM TWO INCHES AND SHALL NOT EXCEED THE FOOTING THICKNESS. 4. FOOTINGS SHALL BE SUPPORTED ON UNDISTURBED NATURAL SOIL OR ENGINEERED FILL. 5. THE SILL PLATE OR FLOORSYSTEMSHALL BE ANCHORED TO THE FOUNDATION WITH 1/2"—INCH—DIAMETER BOLTS PLACED SIX FEET ON CENTER AND NOT MORE THAN 12" INCHES FROM CORNERS. BOLTS SHALL EXTEND A MINIMUM OF 15" INCHES INTO MASONRY OR SEVEN INCHES INTO CONCRETE. SILL PLATES SHALL BE PROTECTED AGAINST DECAY WHERE REQUIRED BY 780CMR 3603.22. 6, PIER AND COLUMN FOOTING SIZES SHALL BE BASED ON THE TRIBUTARY LOAD AND ALLOWABLE SOIL PRESSURE IN ACCORDANCE WITH TABLE 3605.2.3b. 7'-2" 0 I FINISH GRADE ,SLOPE ANCHOR BOLTS @ 6'O.C.AND 1/2"per FOOT min.6 - 12" FROM ALL CORNERS. FEET FROM WALL. E (see notes 3604 note 5) VIII in 11 IIIIHIiIi !11111 IIco 4"P.C. SLAB 3500#min. (see table 3604.2.2) COMPACTED SUBGRADE \//X\ N UNDISTURBED SOIL C/\�,� (SEE SOIL BEARING CHART) FOUNDATION WALL 10"P.C. \T\//j\�� � \\�/,�/�\ : •. 3000# min. (see notes 3604.4) \��\�/�\/\ %\ �v : • BACKFILL Ix /�/�✓\/\/� • (see notes 3604.1.3.1/ table 3604.4.1.1x) COURSE GRAVEL FOOTING W/KEYWAY 4 (see 3604.3/table3604.3.1) (SEE UNDISTURBED SOIL SOIL BEARING CHART) Garage Foundation Wall Detail Scale: 1/2"=1'0" „ FINISH GRADE SLOPE 1/2"per FOOT min.6 Jr ANCHOR BOLTS © 6'O.C.AND FEET FROM WALL. a 12" FROM ALL CORNERS. In Hill IIIIIII!II III I II !I (see notes 3604 note 5) FOUNDATION WALL 10"P.C. ` • 3000# min. (see notes 3604.4) BACKFILL (see notes 3604.1.3.1/ •. table 3604.4.1.1o) DAMPROOF or WATERPROOF TO FINISH GRADE \ /\\/�`•' (see notes 3604.6) 4"PERFORATED DRAIN PIPE COURSE GRAVEL ��5 �;,�y . FOOTING W/KEYWAY (see 3604.3/table3604,3.1) 4"P C SLAB 300 in "A (see table 3604 2 2) 4 00 0R 00 0 000�0Q0 0 Foundation Wall Detail Scale: 1/2"=1'0" 86 -0 — ---------------------��I -----� ---------- II i -- III ------I I-----�H III typ. 12" dio.CONCRETE FILLED I IL ____ IIS O Ill SONOTUBES min. 3500# CONCRETE 15'-0° N o III min. 48" BELOW GRADE. III I n 13'-4" DL -----I II Ili - - - - - - - - - - - - - - - - ----------- III I III I III ----I III typ. 24"x 12" DEEP CONTIUOUS FOOTING ! 0 ill I I r------------------ t I III - -' I III -------"�--! I I - - - -- ---IIS------------------------------------I�--------------------------- - - - - -- -- I I L-- -- —------------� r--------- -------------------------- ----------------- --------- ----- -------- r___— ----- 6068 SLIDER I I I I I I I 25'-8" 1 I I I I 2" x 6" KNEE—WALL I I I o 14., � QI , � I typ.10" CONCRETE FOUNDATION I, I NE S CRETLAB 3000 min I--- WALL min. 3000# CONCRETE W/ I typ. 4 CO # o BEAM F OCKET -------- r------------ I I 4),2"x10" HEM—FIR or SOILD I _ I 6'x10" HEM—FIR GRIDER. of I L — — — — — — — — — — — — ---- —J _ O - 1 I N 1 5'-6" 5'-4" 5'-4" 7'-0" 7'-O" 7'-0" 6'-8" 5'-4" 5'-4" 5 -10 r - - I — — — — — — — — — — T-- I — — — — — — — — — — — — I I I I I I - — — — ----- ----------BEAM POCKET I I I I 0 I I typ. 3 1/2" dia. CONCRETE `O FILLED LALLY COLUMNS. I I I F--- -----------------� I I typ. 24% 12 DEEP CONTIUOUS FOOTING "olI I F-------------------- — ,— I I I I I typ. 4" CONCRETE SLAB 3500# min. 0 I I h SLOPE FLOOR TO DRAIN TO I L_ GRAD a I Ln I typ.10" CONCRETE FOUNDATION WALL min. 3000# CONCRETE W/ I I -- -----I—__ _____ ___ ANCHOR BOLTS Q 60 O.C. AND I ----------- -- — — — — — —— --� o ! 12" FROM ALL CORNERS. I L-------- -- -------------------------- — I I I L---------------------------------------- typ. 24"x 12" DEEP CONTIUOUS FOOTING 4 - 4,. 16'-0" 3604.2,2 CONCRETE: CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE S i MLIVG I H AS SHOWN IN I ABLE 3604.2.2 AND SHALL BE AIR ENTRAINED WHEN SUBJECT TO FREEZING AND THAWING DURING CONSTRUCTION. TOTAL AIR CONTENT(PERCENT BY VOLUME OF CONCRETE)SHALL NOT BE LESS THAN 5% OR MORE THAN 7%. 16'-0" :� 0 I O N ANCHOR BOLTS Q 6'0' O.C. AND 12" FROM ALL. CORNERS. typ. 4" CONCRETE SLAB 3500# min. SLOPE FLOOR TO DRAIN TO OVERHEAD GARAGE DOORS. I I I I FROST -WALL min. 48" BELOW GRADE I I I L- ------------------------------ 3'-0" EXCEPTION: CONCRETE MIXTURES USED FOR EXTERIOR PORCHES,CARPORT SLABS, AND STEPS THAT WILL BE EXPOSED TO FREEZING AND THAWING IN THE PRESENCE OF DEICING CHEMICALS SHALL CONSIST OF 520 POUNDS(236 kg) OF CEMENT PER CUBIC YARD OF CONCRETE WHICH MEETS ASTM C 150 OR C 595 AS LISTED IN APPENDIX A OF THE MASSACHUSETTS STATE BUILDING CODE. ALL CONCRETE FOOTINGS TO BEAR ON UNDISTURBED SOIL. DEPRESS FOUNDATION TO ALLOW FOR 2-9'0"X7'0" OVERHEAD GARAGE DOORS 20'-0" . 3' 0„ . 26'-0" 6,�z5lso 6 A-112 0 0 ELEVATIONS SCALE: 0 2' 4 6' 1/4"= 1'-0" PLAN #. Q 1.10.003 o � N U oho E O O N 0 E o N o o° o \a C o O U ` m 0 yo o _ ui m o c o ET m o 0 � E � 0 00,0- O Q a N t Q N a C Ot O �U'ON OO�.a E O0 a L N O C >— 0 a N aam Dov w3 o � 3•o'ai°�-� >E Nv' as N Ca -aEoo 00 � v u a� N O N O O C 0, O C C S0_ooa°mo d a c U V, y O N Q c 0.n o a� .- E o u oN a O N zow v�aom C O. G Q U 0 O d> L O O O Ow. n U m v 0 0 a m o = L au) O U 0 O 0 0 a T Q � Y 1= � (/) 0> m � m O U C w p ¢ o cj� Q o CD o � N m CCS J W Dj Q) L- N r� O LLJw _, DOa U-) I— o U O z O E- Q O m ,U M O � o Q lsD � x O C 04 C/) J z r-+ O Q.i z CC3 �D Ln N 00 00 LO