HomeMy WebLinkAbout44 Maine Avenue Proposed Septic DesignTOP OF FOUNDATION ELEV. = 101•20 i fl 4" CAST IRON PIPE (OR EQUAL) MINIMUM PITCH 1/4" PER FT. ELEV.= 9_ S 0 ELEV. _ 97.45 FT. MINIMUM FROM SLAB OR CRAWL SPACE CONCRETE COVERS 4" SCHEDULE 40 PVC PIPE MIN. PITCH 1/8" PER FT. TEE ELEV. 17.21LEE S E VV ELEV. = 98 T1 6" SUMP ELEV. DISTRIBUTION ELEV. (TO BE PLACED ON FIRM BASE) Box -BUO TO BE WATER TESTED 1500t GALLON IF MORE THAN ONE OUTLET SEP11C TANK (TO BE PLACED ON FIRM BASE) 3/4" TO 1 1/2' CLEAN J DOUBLE WASHED STONE FREE OF FINES k SILT SEWAGE DISPOSAL SYSTEM PROFILE NOT TO SCALE - 1\x¢9 r? 00 100 L � 9 \"\ coy. ema,a ue,p✓ 1-1�-/ A ai �98y `._ O J too W, � 9.6 � �, _ 100.00 100.1 i E� Spool ``� z 100.2 w1100.5 (I'D 54000.0 TEST%/ o. / i Qtw 0.7 ` 99'e", / E I CLEAN SAND INSPECTION PORT LOAM AND SEED 2" LAYER OF 1 /8' TO 1/2 MAX. WAS STONE 97.05 MIN, NOTTREQUIRED 0 0 4.5. o ° J 95.77ELEV. oo0a0oa°0 "0" °14 0ELEV. x.94.60 HIGH CAPAL7TY/NFILTRA TORS W7H STONE Z WELL N/A IN AN _11' X 40' X 24 ' TRENCH FORMA7JON m 5.50 ZONE INDEX SOIL ABSORPTION U-) ADJUST SYSTEM (SAS) USGS PROBABLE WATER TABLE ELEV. OBSERVED WATER TABLE ( / / ) ELEV. BOTTOM OF TEST HOLE ELEV. • 100.6 10' 1506 -GALLON, -SEPPC TATTK .0 LEGEND: EXISTING SPOT ELEVATION 00„0 EXISTING CONTOUR----00---- FINAL SPOT ELEVATION 00. FINAL CONTOUR SOIL TEST LOCATION UTILITY POLE -O TOWN WATER -Ww CATCH BASIN 0111) GAS LINE G - CESSPOOLO C.P. CLEANOUT 0. Yarmouth Health Department /APPROVED I • - , SOIL TEST DATE OF SOIL TEST QCKKE 5.' 20m_ SOIL TEST DONE BY aAEETSER EN ltjf l inlG ' WITNESSED BY _A, YQ-q HONE OBSERVATION HOLE 1 ELEV.- 99.60 PERCOLATION RATE _<�2 MIN./INCH AT 68 INCHES DEPTH f 98.2 TEXTURE COLOR MOTT. 00.7 0-10 A 1198.7 10YR4/2. NO 99+ 10-32 LOIS 191 & 193 \ 10,000 f S.F. ?. \99.5 \100.2 32-126 \ v'100.6 FINE SAND 2.5Y7/4 ACTUAL SIZE OF SEPTIC TANK 1500 GAL j OF ,100 I CLEAN SAND INSPECTION PORT LOAM AND SEED 2" LAYER OF 1 /8' TO 1/2 MAX. WAS STONE 97.05 MIN, NOTTREQUIRED 0 0 4.5. o ° J 95.77ELEV. oo0a0oa°0 "0" °14 0ELEV. x.94.60 HIGH CAPAL7TY/NFILTRA TORS W7H STONE Z WELL N/A IN AN _11' X 40' X 24 ' TRENCH FORMA7JON m 5.50 ZONE INDEX SOIL ABSORPTION U-) ADJUST SYSTEM (SAS) USGS PROBABLE WATER TABLE ELEV. OBSERVED WATER TABLE ( / / ) ELEV. BOTTOM OF TEST HOLE ELEV. • 100.6 10' 1506 -GALLON, -SEPPC TATTK .0 LEGEND: EXISTING SPOT ELEVATION 00„0 EXISTING CONTOUR----00---- FINAL SPOT ELEVATION 00. FINAL CONTOUR SOIL TEST LOCATION UTILITY POLE -O TOWN WATER -Ww CATCH BASIN 0111) GAS LINE G - CESSPOOLO C.P. CLEANOUT 0. Yarmouth Health Department /APPROVED I • - , SOIL TEST DATE OF SOIL TEST QCKKE 5.' 20m_ SOIL TEST DONE BY aAEETSER EN ltjf l inlG ' WITNESSED BY _A, YQ-q HONE OBSERVATION HOLE 1 ELEV.- 99.60 PERCOLATION RATE _<�2 MIN./INCH AT 68 INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-10 A LOAMY SAND 10YR4/2. NO ; 10-32 B LOAMY SAND 10YR5/8 R, 40- SE C i 32-126 C FINE SAND 2.5Y7/4 ACTUAL SIZE OF SEPTIC TANK 1500 GAL j APPROVED: BOARD OF HEALTH DATE AGENT NO WATER ENCOUNTERED AT 196" ELEV. Ag 1n r PIN[ sTRfET PANKLIN �M1,,MSR sr. �, WATER yccvs PEARL 0 BROADWAY x ^ 2 i H a DESIGN CALCULATIONS PROPOSED SEPTIC DESIGN FOR "DREW BERNARD NUMBER OF BEDROOMS 4 GARBAGE DISPOSAL UNIT ; TOTAL ESTIMATED FLOW R, 40- SE C i REQ1RED NK CAPACITY _850- GAL ACTUAL SIZE OF SEPTIC TANK 1500 GAL j SCALE 1 " = 20'� I SOIL CLASSIFICATION DESIGN PERCOLATION RATE S 5 MIN./IN. I EFFLUENT LOADING RATE --0.7-4- GAL./DAY/S.F. LEACHING AREA 844.00 SQ. FT. REv. ISHEET 1 OF 1 CAPACITY LEACHING (AREA X RATE) -41MI GAL./DAY x44.00 X 0.74 RESERVE LEACHING CAPACITY AZOM GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE SHALL . _ BE MORTARED IN PLACE. _ 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION- CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO -COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. - 8. PARCEL IS IN FLOOD ZONE C 9. LOT IS SHOWN ON ASSESSORS MAP 22 AS PARCEL 377 10, EXISTING DWELLJNG AND SEPTICS ARE TO BE REMOVED. 11. ,ALL UTILITIES ARE TO BE REMOVED AND REPLACED WITH NEW SERVICES. APPROVED: BOARD OF HEALTH DATE AGENT C.• jS8�PROJ`6278-00�dwg`6278-sos1.OWG 02007 SWEETSER ENGINEERING� I IC at �►4 i PIN[ sTRfET PANKLIN �M1,,MSR sr. �, WATER yccvs PEARL 0 BROADWAY x ^ 2 i H a PROPOSED SEPTIC DESIGN FOR "DREW BERNARD LOG. � .MAINE AVE. 44 NEST YARMOUTH, MASS. Sr=ER M"TGLNEERING 235 GREAT WESTERN ROAD 508- P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 DATE DEC. 11, 200 SCALE 1 " = 20'� I REV. DEC. 14, 2007 JOB No. 6278-00 LOCATION MAP REv. ISHEET 1 OF 1 C.• jS8�PROJ`6278-00�dwg`6278-sos1.OWG 02007 SWEETSER ENGINEERING� I IC at �►4 i