HomeMy WebLinkAbout59.192 - Drawing A7-7 Nailing Schedule and Details 2RAFTER ® 16" O.C.
RIDGE VENT
N
ROLL VENT 4�
SIDING SEE ELEVATION U o
o H2.5 ® EA. RAFTER (TYP.)
00
"TYVEK" HOUSEWRAP RIDGE BOARD " U
(STRUCTURAL SIZES a o
MAY VARY)
fl" CDX PLYWOOD �o ° TOP PLATE U
2x6 ® 16" O.C. W U N
15// FELT PAPER O
FIBERGLASS INSULATION Q U (j�
T� J 5/8" COX PLYWOOD LL
RAFTER TO PLATE CONNECTION N
6 MIL. POLY VAPOR BARRIER RAFTER VENT SCALE: N.T.S. O m
WHERE INSUL
O" G.W.B. INSULATION (< O
2x10 RAFTERS v z — >
D
BEAM &STRAP (D
H
LSTA ® EA. RAFTER vi }
21" Z m
011C
ICAL RIDGE VENT DETAIL DSDTANCE og
(D!)�—ps
ICAL WALL DETAIL ALE ,-,/2" _ ,'-a" o LU o
CALE 1-1/2" = 1'-0" / /
/ J/L
RIDGE BEAM
NOTE:
RIDGE STRAPS ARE NOT REQUIRED
WHEN COLLAR TIES OF NOMINAL 1x6 _J
OR 2x4 LUMBER ARE LOCATED IN THE
UPPER THIRD OF THE ATTIC SPACE
AND ATTACHED TO RAFTERS USING
D RIDGE BAND STRAP 5)10d NAILS EACH END a
SCALE: N.T.S. 1—
w
O =
O ~
n 06
o
2x6 DBL TOP PLATE /� w
ror J
IZ
SIMPSON SP6/SP4 (20 GA.) z }
'�' 1
W
J W
z U cc
J
HEADER `` nn
FULL HGT. STUD L6 Z V
HDR UPLIFT STRAP a z
ACK STUD REFER TO TABLE 9 � ^Z
SIMPSON �
PHD (14 GA.) WINDOW SILL J
PLATE O J
Q
5/8" ANCHOR BOLTS \ /�
W/ 3'1 PLATE WASHERS \ V z
\ U
w
�\ oLij
\ 12 GA. ANCHORS TYP. 0 {—
\ \ a I=
�\ \
i DATE: 04112/2011.
SCALE: AS NOTED
H STUDS & HEADERS DRAWING #:
SCALE: N.T.S.
JOINT DESCRIPTION
NUMBER Off NUMBER OF NAIL SPACING
COMMON NAILS BOX (JAILS
ROOF FRAMING
BLOCKING TO RAFTER (TOE NAILED) 2-8d 2- I Od EACH EIJD
RIM BAORD TO RAFTER (END (JAILED) 2- 16d 3-1 6d EACH END
WALL FRAMING
TOP PLATES AT INTERSECTIONS (FACE NAILED) 4- I Gd 5- 16d AT JOINTS
STUD TO STUD (FACE NAILED) 2- 16d 2- I Gd 24" O.C.
HEADER TO HEADER (FACE NAILED) 16d 16d 24" O.C. ALONG EDGES
FLOOR FRAMING
JOIST TO SILL, TOP PLATE OR GIRDER (TOENAILED) 4-8d 4- I Od PER JOIST
BLOCKING TO JOIST (TOE NAILED) 2-8d 2- I Od EACH END
BLOCKING TO SILL OR TOP PLATE (TOE NAILED) 3-1 6d 4- 16d EACH BLOCK
LEDGER STRIP TO BEAM OR GIRDER (TOE NAILED) 3- 16d 4- 16d EACH JOIST
JOIST ON LEDGER TO BEAM (TOE NAILED) 3-8d 3- I Od PER JOIST
BAND JOIST TO JOIST (END NAILED) 3-I 6d 4-1 6d PER JOIST
BAND JOIST TO SILL OR TOP PLATE (TOE NAILED) 2- I Gd 3- 16d PFR FOOT
ROOF SHEATHING
WOO ';"'-FULL S�RUCiURAL PANELS
RAFTERS OR TRUSSES SPACED UP TO 16" O.C. 8d I Od 6" EDGE / 6" FIELD
RAFTERSOR TRUSSES SPACED OVER 16" O.C. 8d I Od 4" EDGE / 6" FIELD
GABLE ENDWALL RAKE OR RAKE TRUSS w!o GABLE OVERHANG 8d I Od 6" EDGE / 6" FIELD
GABLE ENI D'JVALL RAKE OR RAKE TRUSS w! STRUCTURAL OUTLOOKERS 8d I Od 6" EDGE / 6" FIELD
GABLE ENDWALL RAKE OR RAKE TRUSS w/ LOOKOUT BLOCKS 8d I Od 4" EDGE / 4" FIELD
CEILING SNEATf11NG
GYPSUM J�ALLBOARD Sd COOLERS - 7" EDGE / I O" FIELD
WALL SHEATHING
MOOD STRUCTURAL PANELS
STUDS 5 ACED UP TO 24" O.G. 8d I Od 6" EDGE / 12" FIELD
I/2" AND 25!32" FIBERBOARD PANELS 8d - 3" EDGE / G" FIELD
I/2" GYP UM WALLBOARD 5d COOLERS - 7" EDGE/ 10" FIELD
FLOOR SNEATt11NG
WOOD 5 RUCTURAL PANELS
I " OR LE 5 8d I Od 6" EDGE / I " FIELD
GREATER
THAN I"
I Od
16d
6" EDGE / 6" FIELD