Loading...
HomeMy WebLinkAbout59.192 - Drawing A7-7 Nailing Schedule and Details 2RAFTER ® 16" O.C. RIDGE VENT N ROLL VENT 4� SIDING SEE ELEVATION U o o H2.5 ® EA. RAFTER (TYP.) 00 "TYVEK" HOUSEWRAP RIDGE BOARD " U (STRUCTURAL SIZES a o MAY VARY) fl" CDX PLYWOOD �o ° TOP PLATE U 2x6 ® 16" O.C. W U N 15// FELT PAPER O FIBERGLASS INSULATION Q U (j� T� J 5/8" COX PLYWOOD LL RAFTER TO PLATE CONNECTION N 6 MIL. POLY VAPOR BARRIER RAFTER VENT SCALE: N.T.S. O m WHERE INSUL O" G.W.B. INSULATION (< O 2x10 RAFTERS v z — > D BEAM &STRAP (D H LSTA ® EA. RAFTER vi } 21" Z m 011C ICAL RIDGE VENT DETAIL DSDTANCE og (D!)�—ps ICAL WALL DETAIL ALE ,-,/2" _ ,'-a" o LU o CALE 1-1/2" = 1'-0" / / / J/L RIDGE BEAM NOTE: RIDGE STRAPS ARE NOT REQUIRED WHEN COLLAR TIES OF NOMINAL 1x6 _J OR 2x4 LUMBER ARE LOCATED IN THE UPPER THIRD OF THE ATTIC SPACE AND ATTACHED TO RAFTERS USING D RIDGE BAND STRAP 5)10d NAILS EACH END a SCALE: N.T.S. 1— w O = O ~ n 06 o 2x6 DBL TOP PLATE /� w ror J IZ SIMPSON SP6/SP4 (20 GA.) z } '�' 1 W J W z U cc J HEADER `` nn FULL HGT. STUD L6 Z V HDR UPLIFT STRAP a z ACK STUD REFER TO TABLE 9 � ^Z SIMPSON � PHD (14 GA.) WINDOW SILL J PLATE O J Q 5/8" ANCHOR BOLTS \ /� W/ 3'1 PLATE WASHERS \ V z \ U w �\ oLij \ 12 GA. ANCHORS TYP. 0 {— \ \ a I= �\ \ i DATE: 04112/2011. SCALE: AS NOTED H STUDS & HEADERS DRAWING #: SCALE: N.T.S. JOINT DESCRIPTION NUMBER Off NUMBER OF NAIL SPACING COMMON NAILS BOX (JAILS ROOF FRAMING BLOCKING TO RAFTER (TOE NAILED) 2-8d 2- I Od EACH EIJD RIM BAORD TO RAFTER (END (JAILED) 2- 16d 3-1 6d EACH END WALL FRAMING TOP PLATES AT INTERSECTIONS (FACE NAILED) 4- I Gd 5- 16d AT JOINTS STUD TO STUD (FACE NAILED) 2- 16d 2- I Gd 24" O.C. HEADER TO HEADER (FACE NAILED) 16d 16d 24" O.C. ALONG EDGES FLOOR FRAMING JOIST TO SILL, TOP PLATE OR GIRDER (TOENAILED) 4-8d 4- I Od PER JOIST BLOCKING TO JOIST (TOE NAILED) 2-8d 2- I Od EACH END BLOCKING TO SILL OR TOP PLATE (TOE NAILED) 3-1 6d 4- 16d EACH BLOCK LEDGER STRIP TO BEAM OR GIRDER (TOE NAILED) 3- 16d 4- 16d EACH JOIST JOIST ON LEDGER TO BEAM (TOE NAILED) 3-8d 3- I Od PER JOIST BAND JOIST TO JOIST (END NAILED) 3-I 6d 4-1 6d PER JOIST BAND JOIST TO SILL OR TOP PLATE (TOE NAILED) 2- I Gd 3- 16d PFR FOOT ROOF SHEATHING WOO ';"'-FULL S�RUCiURAL PANELS RAFTERS OR TRUSSES SPACED UP TO 16" O.C. 8d I Od 6" EDGE / 6" FIELD RAFTERSOR TRUSSES SPACED OVER 16" O.C. 8d I Od 4" EDGE / 6" FIELD GABLE ENDWALL RAKE OR RAKE TRUSS w!o GABLE OVERHANG 8d I Od 6" EDGE / 6" FIELD GABLE ENI D'JVALL RAKE OR RAKE TRUSS w! STRUCTURAL OUTLOOKERS 8d I Od 6" EDGE / 6" FIELD GABLE ENDWALL RAKE OR RAKE TRUSS w/ LOOKOUT BLOCKS 8d I Od 4" EDGE / 4" FIELD CEILING SNEATf11NG GYPSUM J�ALLBOARD Sd COOLERS - 7" EDGE / I O" FIELD WALL SHEATHING MOOD STRUCTURAL PANELS STUDS 5 ACED UP TO 24" O.G. 8d I Od 6" EDGE / 12" FIELD I/2" AND 25!32" FIBERBOARD PANELS 8d - 3" EDGE / G" FIELD I/2" GYP UM WALLBOARD 5d COOLERS - 7" EDGE/ 10" FIELD FLOOR SNEATt11NG WOOD 5 RUCTURAL PANELS I " OR LE 5 8d I Od 6" EDGE / I " FIELD GREATER THAN I" I Od 16d 6" EDGE / 6" FIELD