Loading...
HomeMy WebLinkAbout59.192 - Drawing A7-7 Nailing Schedule and Details 4I'. SIDING SE "TYVEK" H fl" CDX PL 2x6 ® 16" FIBERGLAS' 6 -MIL POL D" G.W.B. D='C AL WALL DETAIL SCALE 1-1/2" = 1'-0" RIDGE VENT ROLL VENT RIDGE BOARD MATRUCATU>AL SIZES 15# FELT PAPER 5/8" COX PLYWOOD — RAFTER VENT -. WHERE INSUL. INSULATION 2x10 RAFTERS TYPICAL RIDGE VENT E SCALE 1-1/2" ETAI DESCRIPTION NUMBER OF NUMBER OF NAIL SPACING ,JOINT COMMON NAILS BOX NAILS Q ROOF FRAMING BLOCKING TO RAFTER (TOE NAILED) 2-8d 2-1 Oct EACH END RIM BAORD TO RAFTER (END NA!LED) 2-' --; 3- I Gd EACH END WALL FRAMING TOP PLATES AT INTERSECTIONS (FACE NAILED) 4-1 Gd 5-1 Gd AT JOINTS STUD TO STUD (FACE NAILED) 2-1 6d 2-1 Gd 24" O.C. HEADER TO HEADER (FACE NAILED) I Gd I Gd 24" O.C. ALONG EDGES FLOOR FRAMING JOIST TO 51LL. TOP PLATE OR GIRDER (TOE NAILED) 4-8d 4-1 Od PER JOIST BLOCKING TO J015T (TOE NAILED) 2-8d 2-1 Od EACH END BLOCKING TO SILL OR TOP PLATE (TOE NAILED) 3-1 Gd 4- I Gd EACH BLOCK LEDGER STRIP TO BEAM OR GIRDER (TOE NAILED) 3- I Gd 4-1 Gd EACH JOIST J015T ON LEDGER TO BEAM (TOE NAILED) 3-8d 3-1Od PER JOIST BAND J015T TO J015T (END NAILED) 3-1 Gd 4-1 Gd PER J015T BAND J015T TO SILL OR TOP PLATE (T OE NAILED) 2-1 Gd 3- I Gd PER FOOT ROOF SHEATHING WOOD STRUCTURAL PANELS _ RAFTERS OR TRUSSES SPACED UP TO I G" O.C. 8d 1011 G" EDGE / G' FIELD RAFTERS OR TRUSSES SPACED OVER I G" O.C. 8d I Od 4' EDGE / G" FIELD GABLE ENDV,/ALL RAKE OR RAKE TRU55 w/o GABLE OVERHANG 8d I Oct a H o N G" EDGE / G" FIELD GABLE ENDWALL RAKE OR RAKE TRUSS w,l STRUCTURAL OUTLOOKERS 8d I Od G" EDGE/ G" FIELD GABLE ENDWALL RAKE OR RAKE TRU55 w/ LOOKOUT BLOCKS - 8d 1 Od 4" EDGE / 4" FIELD CEILING SHEATHING GYPSUM WALLBOARD 5d COOLERS - 7" EDGE/ 10" FIELD WALL SHEATHING WOOD STRUCTURAL PANELS STUDS SPACED UP TO 24'0-C. 8d I Od G" EDGE/ 12" FIELD I/2" AND 25/32" FIBERBOARDPANEL5 Sd 3" EDGE/ G" FIELD I/2" GYPSUM WALLBOARD 5d COOLERS 7" EDGE/ 10" FIELD FLOOR SHEATHING WOOD STRUCTURAL PANELS J' OR LESS 8d I Od G" EDGE / I " FI 'ILD GREATER THAN 1 " I Od I Gd 6" EDGE/ 6" FIELD 21" END DISTAI :R TO PLA1 N.T.S. BEAM & STRAP LSTA @ EA. RAFTER -TER 0 16 O.C. i @ EA. RAFTER (TYP.) TOP PLATE RIDGE BEAM NOTE: RIDGE STRAPS ARE NOT REQUIRED WHEN COLLAR TIES OF NOMINAL 14 OR 2x4 LUMBER ARE LOCATED IN THE UPPER THIRD OF THE ATTIC SPACE AND TO D RIDGE BAND STRAP 5)10d NAAILS CHED EACH END RAFTERS USING SCALE: N.T.S. SIMPSON PHD (14 GA.) 5/8" ANCHOR BOLTS W/ 3"x3" PLATE WASHERS 4 2x6 DBL TOP PLATE SP6/SP4 (20 GA.) HEADER FULL HJSTUD� HDR UPLIFT STRAP —JACK REFER TO TABLE 9 WINDO\ LAT H SIUUS & H ADERS SCALE: N.T.S. GA. ANCHORS TYP. U) N J Q Q 0) � W s w 0 �x W _J U E W CV O D 0 W W -� � Cil Q — L' �Zi L6 Z - c� z - O J J z . L a � DATE: 04/12/2011 SCALE: AS NOTED a H o N z L � p U) J Q Q � W 0 �x W E W D 0 W W -� U r^ v f �Zi L6 Z - V um Z s J J z . L a � DATE: 04/12/2011 SCALE: AS NOTED DRAWING #: