HomeMy WebLinkAbout59.192 - Drawing A7-7 Nailing Schedule and Details 4I'.
SIDING SE
"TYVEK" H
fl" CDX PL
2x6 ® 16"
FIBERGLAS'
6 -MIL POL
D" G.W.B.
D='C
AL WALL DETAIL
SCALE 1-1/2" = 1'-0"
RIDGE VENT
ROLL VENT
RIDGE BOARD
MATRUCATU>AL SIZES
15# FELT PAPER
5/8" COX PLYWOOD —
RAFTER VENT -.
WHERE INSUL.
INSULATION
2x10 RAFTERS
TYPICAL RIDGE VENT E
SCALE 1-1/2"
ETAI
DESCRIPTION
NUMBER OF
NUMBER OF
NAIL SPACING
,JOINT
COMMON NAILS
BOX NAILS
Q
ROOF FRAMING
BLOCKING TO RAFTER (TOE NAILED)
2-8d
2-1 Oct
EACH END
RIM BAORD TO RAFTER (END NA!LED)
2-' --;
3- I Gd
EACH END
WALL FRAMING
TOP PLATES AT INTERSECTIONS (FACE NAILED)
4-1 Gd
5-1 Gd
AT JOINTS
STUD TO STUD (FACE NAILED)
2-1 6d
2-1 Gd
24" O.C.
HEADER TO HEADER (FACE NAILED)
I Gd
I Gd
24" O.C. ALONG EDGES
FLOOR FRAMING
JOIST TO 51LL. TOP PLATE OR GIRDER (TOE NAILED)
4-8d
4-1 Od
PER JOIST
BLOCKING TO J015T (TOE NAILED)
2-8d
2-1 Od
EACH END
BLOCKING TO SILL OR TOP PLATE (TOE NAILED)
3-1 Gd
4- I Gd
EACH BLOCK
LEDGER STRIP TO BEAM OR GIRDER (TOE NAILED)
3- I Gd
4-1 Gd
EACH JOIST
J015T ON LEDGER TO BEAM (TOE NAILED)
3-8d
3-1Od
PER JOIST
BAND J015T TO J015T (END NAILED)
3-1 Gd
4-1 Gd
PER J015T
BAND J015T TO SILL OR TOP PLATE (T OE NAILED)
2-1 Gd
3- I Gd
PER FOOT
ROOF SHEATHING
WOOD STRUCTURAL PANELS
_
RAFTERS OR TRUSSES SPACED UP TO I G" O.C.
8d
1011
G" EDGE / G' FIELD
RAFTERS OR TRUSSES SPACED OVER I G" O.C.
8d
I Od
4' EDGE / G" FIELD
GABLE ENDV,/ALL RAKE OR RAKE TRU55 w/o GABLE OVERHANG
8d
I Oct
a
H
o
N
G" EDGE / G" FIELD
GABLE ENDWALL RAKE OR RAKE TRUSS w,l STRUCTURAL OUTLOOKERS
8d
I Od
G" EDGE/ G" FIELD
GABLE ENDWALL RAKE OR RAKE TRU55 w/ LOOKOUT BLOCKS
- 8d
1 Od
4" EDGE / 4" FIELD
CEILING SHEATHING
GYPSUM WALLBOARD 5d COOLERS
-
7" EDGE/ 10" FIELD
WALL SHEATHING
WOOD STRUCTURAL PANELS
STUDS SPACED UP TO 24'0-C.
8d
I
Od
G" EDGE/ 12" FIELD
I/2" AND 25/32" FIBERBOARDPANEL5
Sd
3" EDGE/ G" FIELD
I/2" GYPSUM WALLBOARD
5d COOLERS
7" EDGE/ 10" FIELD
FLOOR SHEATHING
WOOD STRUCTURAL PANELS
J' OR LESS
8d
I Od
G" EDGE / I " FI 'ILD
GREATER THAN 1 "
I Od
I Gd
6" EDGE/ 6" FIELD
21"
END
DISTAI
:R TO PLA1
N.T.S.
BEAM & STRAP
LSTA @ EA. RAFTER
-TER 0 16 O.C.
i @ EA. RAFTER (TYP.)
TOP PLATE
RIDGE BEAM
NOTE:
RIDGE STRAPS ARE NOT REQUIRED
WHEN COLLAR TIES OF NOMINAL 14
OR 2x4 LUMBER ARE LOCATED IN THE
UPPER THIRD OF THE ATTIC SPACE
AND TO
D RIDGE BAND STRAP 5)10d NAAILS CHED EACH END RAFTERS USING
SCALE: N.T.S.
SIMPSON
PHD (14 GA.)
5/8" ANCHOR BOLTS
W/ 3"x3" PLATE WASHERS
4
2x6 DBL TOP PLATE
SP6/SP4 (20 GA.)
HEADER
FULL HJSTUD�
HDR UPLIFT STRAP
—JACK REFER TO TABLE 9
WINDO\ LAT
H SIUUS & H ADERS
SCALE: N.T.S.
GA. ANCHORS TYP.
U)
N
J
Q
Q
0)
�
W
s
w
0
�x
W
_J
U
E
W
CV
O
D
0
W
W
-�
�
Cil
Q
—
L'
�Zi L6
Z -
c�
z
-
O
J
J
z .
L
a
�
DATE: 04/12/2011
SCALE: AS NOTED
a
H
o
N
z
L
�
p
U)
J
Q
Q
�
W
0
�x
W
E
W
D
0
W
W
-�
U
r^
v f
�Zi L6
Z -
V
um
Z
s
J
J
z .
L
a
�
DATE: 04/12/2011
SCALE: AS NOTED
DRAWING #: