Loading...
HomeMy WebLinkAbout59.192 - Drawing A7-7 Nailing Schedule and Details—RAFTER ® 16" O.C. RIDGE VENT ROLL VENT +� SIDING SEE ELEVATION0 a o :r, H2.5 ® EA. RAFTER (TYP.) "TYVEK" HOUSEWRAP RIDGE BOARD U (STRUCTURAL SIZES 0 —1 MAY VARY)(� °0 TOP PLATE D" COX PLYWOOD 0 U \,1 J2! N 2x6 ®16" O.C. I W 0 N co 15# FELT PAPER/ l' 4+ FIBERGLASS INSULATION 5/8" COX PLYWOOD U RAFTER VENT R RAFTER TO PLATE CONNECTION s 6MIL. POLY VAPOR BARRIER WHERE INSUL. ` LJ SCALE: N.T.S. m i D"G.W.B. INSULATION 2x10 RAFTERS U z _ >-- Ln D BEAM &STRAP � LSTA O EA. RAFTER cn 21" Z m END 0 Z RIDGE VENT DETAIL DISTANCE o > Q 1 TYPICAL WALL DETAIL @)!��Pl�SC/2" = 1'-0" o w o SCALE 1-1/2" = 1'-0" 0 / I RIDGE BEAM NOTE: (f) RIDGE STRAPS ARE NOT REQUIRED WHEN COLLAR TIES OF NOMINAL 1x6 .J OR 2x4 LUMBER ARE LOCATED IN THE _ UPPER THIRD OF THE AMC SPACE D AND ATTACHED TO RAFTERS USING Q RIDGE BAND STRAP 5)10d NAILS EACH END Q SCALE: N.T.S. �/ 1'— �y � w o = 0 F.. ® m W C 2x6 DBL TOP PLATE w J ui SIMPSON SP6/SP4 (20 GA.) Lu T z U J 0 HEADER rr nn FULL HGT. STUD L6 Z V HDR UPLIFT STRAP a Z ACK SND REFER TO TABLE 9 LL SIMPSON PHD (14 GA.) WNDOW SILL J PLATE J Lu v Q 5/8" ANCHOR BOLTS {n w/ 3"x3" PLATE WASHERS \ z \ U \I LU �` \ \ 12 GA. ANCHORS TYP. � H \ 0 - DATE: 04112/2011 SCALE: AS NOTED H STUDS & HEADERS DRAWING #: SCALE: N.T.S. a JOINT DESCRIPTION NUMBER. Off HUMBER or MAIL sPAc'NG cor�tMON NAILS Box NAILS ROOF FRAMING BLOCKING TO RAFTER (TOE NAILED) 2-Sd 2-10,1 EACH END RIM BAORD TO RAFTER (END NAILED) 2- 16d 3- 16d EACH END WALL FRAMING TOP PLATES AT INTERSECTIONS (FACE NAILED) 4- 16d 5-1 6d AT JOINTS STUD TO STUD (FACE NAILED) 2- 16d 2- 16d 24" O.C. HEADER TO HEADER (FACE NAILED) 16d I Gd 24" O.C. ALONG EDGES FLOOR FRAMING JOIST TO SILL, TOP PLATE OK GIRDER (TOE NAILED) 4-8d 4-10J PER JOIST BLOCYJfJG TO JOIST (TOE GIAILED) 2-8d 2- I Od EACH END BLOCKIfJG TO SILL OR TOP P'.ATE (TOE NAILED) 3- 16d 4-1 6d EACH BLOCK LEDGER STRIP TO BEAM OR GIRDER (TOE HAILED) 3- 16d 4-1 6d EACH JOIST JOIST ON LEDGER TO BEAM (TOE NAILED) 3-8d 3-10d PER JOIST BAND JOIST TO JOIST (END NAILED) 3- 16d 4- I Cd PER JOIST BAND JOIST TO SILL OR TOP PLATE (TOE NAILED) 2- 16d 3- 16d PER FOOT ROOF 5f1EATHING WOOD STRUCTURAL PANELS RAFTERS OR TRUSSES SPACED UP TO 16" O.C. 8d I Od 6" EDGE / 6" FIELD RAFTERS OR TRUSSES SPACED OVER 16" O.C. 8d I Od 4" EDGE / 6" FIELD GABLE END WALL RAKE OR RAY.E TRUSS v✓/o GABLE OVERHANG 8d i Od 6" EDGE / 6" FIELD GABLE END'JdALL RAKE OF. RAKE TRUSS v./ STRUCTURAL OUTLOOKFRS 8d I Od 6" EDGE/ 6" FIELD GABLE ENDINALL RAKE OR RAKE TRUSS w/ LOCKOUT BLOCKS 8d i Cd 4" EDGE 14 " FIELD CEILING SHEATHING GYPSUM WALLBOARD 5d COOLERS - 7" EDGE / I O" FIELD WALL SHEATHING WOOD STRUCTURAL PANELS STUDS SPACED UP TO 24" O.C. 8d IOd 6" EDGE / 12" FIELD I/2" AND 25/32" FIBERBOARD PANELS 8d - 3" EDGE / C" FIELD I/2" GYPSUM �f✓ALLBOARD Sd COOLERS - 7" EDGE / I O" FIELD FLOOR St1EATNING WOOD STRUCTURAL PANELS I" OR LESS 8d IOd 6" EDGE/ I" FIELD GREATER THAN I 16d 6" EDGE / 6" FIELD