HomeMy WebLinkAbout7 Makepeace Lane Site Plan25.9' ACCESS COVERS TO WITHIN 6" OF FIN. GRADE OF SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE PRECAST H-10 RISERS (TYP.)4"OSCH40 PVC z'm PIPES LEVEL 1ST 2' EXISTING *22.05 t 10" 1000 GAL H-10 14" FT t*21.39' T SEPTIC TANK TEE f*21.14' (RE -USE)*' o°o°o°oo°"Oo 0. ,0°° o ° 4' - ENDS ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM L I BLOCKS OR PRECAST RISERS MORTAR ALL H-10 COMPONENTS INV'` (TYP.) DES 121.6' **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON H-10 SEPTIC TANK IF NOT SUITABLE. LEGEND- EGEND99- 99- EXISTING CONTOUR X 99.1 GAS BAFFLE _. - °_°- "I ;o gogaL�LJLJLJLJIJLJL`�u�Iuuur�ul�ul��l-I�, PROPOSED SPOT EL. TH1 °000°0 18.75 TEST HOLE 27 SLOPE OF GROUND CO-) UTILITY POLE 21.02' FIRE HYDRANT 20.85' C1 OA S PERC MS 10YR 6/4 X, C2 FS TH I 74" 2.5Y 6/4 X' LH PRECAST OR EQUAL. -10 500 GAL. LEACHING CHAMBER BY ACME p 36' EXIST. 1000\ 3/4"-1-1/2" DOUBLE WASHED STONE 4' 1 (3) UNITS REQUIRED GAL ST ALL AROUND PRECAST STRUCTURES (RE -USE)** \ *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL (ALTERNATE BENCHMARK = 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.5' X 12.8T UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS t COMPACTION. (15.221 [21) PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM (CONFIRM SEPTIC TANK INVERT ELEVATIONS NO LOWER THAN THAT SHOWN) ( X SLOPE) (-L-% SLOPE) LEACHING EXIST.- FOUNDATION- SEPTIC TANK 12' D' BOX 12' FACILITY 13.75' BOTTOM TH-1 **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON H-10 SEPTIC TANK IF NOT SUITABLE. LEGEND- EGEND99- 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 198.4] PROPOSED SPOT EL. TH1 MCS TEST HOLE 27 SLOPE OF GROUND CO-) UTILITY POLE 4. FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER. ARNE H. OJALA, PE, SE WITNESS: PHIL RENAUD DATE: NOVEMBER 24, 2009 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 4 0" 24.0' A LS 10YR 2/1 6 B MCS S ' 00 10YR 5/6 21.0' 36" 4. 7 \ C1 OA S PERC MS 10YR 6/4 X, C2 FS TH I 74" 2.5Y 6/4 X' C3 MS 123" J 13.75' NO GROUNDWATER ENCOUNTERED 98-357 Liz \ CAUTION: LOT 5 12,390± S.F. NO GROUNDWATER FOUND NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. \ 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN 4 SAND. \ �/D� 13. WETLAND FLAGGED BY HAMLYN CONSULTING X77 / 14. DIRECT ROOF RUN-OFF TO DRYWELLS OR DRIP ` TRENCHES T C o Bassett A�8 \ � n V S ' 00 �� \ 4. 7 \ R OA S ;3 TH I p 36' EXIST. 1000\ BENCH MARK - CORNER GAL ST CONC. PAD AT EL 23.3' (RE -USE)** \ PAVED DRI (ALTERNATE BENCHMARK = i TOP FNDN. AT EL 25.9') PROP. Z �\ EXISTING DWELLING TOP FNDN. = 25.9' EXIST. \ DECK ` \ \ \J 0 PROP. KITCHEN #5 , \ SHED EXPANSION / 140 9� �C,_ ISOLATED VEGETATED WETLAND #3 Scale: 1 "= 20' 0 10 20 30 40 50 FEET 1, #1 PROPOSED ADDITION FILE OPe�'_ LOCUS MAP NOT TO SCALE ASSESSORS MAP 41 PARCEL 55 LOCUS IS WITHIN FEMA FLOOD ZONE "C" ZONING: R-25 F: 30' S: 15' R: 20' PROPOSED LOT COVERA0227P. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BE ® 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 **RE -USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SIDES2 (33.5 + 12.83) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.83 (.74) = 318 GPD TOTAL: 614 S.F. 455 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 7 MAKEPEACE LANE PROP. WORK LIMIT UNE OF WEST YARMOUTH STAKED SILT FENCE °4 °^^•'�" H: ':h D., ?prtment 1.r.^^ 1 lz/ 1%/o°\ DATE DANIEL A. OJALA, P.E., P.L.S. PREPARED FOR H. TABACHNICK NOVEMBER 25, 2009 REV. 12/15/09 (CALCS) I off508-362-4541 fax 508-362-9880 downcape.com down cope engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 98-357.DWG(SBO) o Bassett s POOo� o E �O n V V Locus R LOCUS MAP NOT TO SCALE ASSESSORS MAP 41 PARCEL 55 LOCUS IS WITHIN FEMA FLOOD ZONE "C" ZONING: R-25 F: 30' S: 15' R: 20' PROPOSED LOT COVERA0227P. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BE ® 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 **RE -USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SIDES2 (33.5 + 12.83) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.83 (.74) = 318 GPD TOTAL: 614 S.F. 455 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 7 MAKEPEACE LANE PROP. WORK LIMIT UNE OF WEST YARMOUTH STAKED SILT FENCE °4 °^^•'�" H: ':h D., ?prtment 1.r.^^ 1 lz/ 1%/o°\ DATE DANIEL A. OJALA, P.E., P.L.S. PREPARED FOR H. TABACHNICK NOVEMBER 25, 2009 REV. 12/15/09 (CALCS) I off508-362-4541 fax 508-362-9880 downcape.com down cope engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 98-357.DWG(SBO)