Loading...
HomeMy WebLinkAbout7 Makepeace Lane Site Plan 2ACCESS COVERS TO WITHIN 6' OF FlN. GRADE 25.9' SYSTEM PROFILE (NOT TO SCALE 2" PEASTONE OR GEOTEXTILE 1 FILTER FABRIC OVER STONE PRECAST H-10 RISERS (TYP.) 2'0 4"0SCH40 PVC PIPES LEVEL IST 2' #22.D5't EXISTING 10" 1000 GAL H-10 14" f*2 TEE SEPTIC TANK IEE f*21.14' (RE—USE)*- .o.o° .00000 GAS BAFFLE o°�°apoonOo 21.02' 20.85' ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3' GRADE 2% SLOPE REQUIRED OVER SYSTEM2� 4.6•I in BLOCKS OR MORTAR ALL PRECAST RISERS 4 COMPONENTS H-10 ENDS (TMP) 5 SIDES 21.6' 8.75' LEGEND 99- EXISTING CONTOUR 3/4"-i-1/2" DOUBLE WASHED STONE 4' `-.H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL 6 ' CRUSHED STONE OR MECHANICAL (98.4] ALL AROUND PRECAST STRUCTURES OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.5' X 12.83' (3) UNITS REQUIRED UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS COMPACTION. (15.221 [2]) 2� SLOPE OF GROUND INSTALLING TO iNSTANG ANY PORTION OF SEPTIC SYSTEM (CONFlR� UTILITY POLE FIRE HYDRANT NOTE; NOT ALL SYYBOL_S MAY APPEAR N TAWING SEPTIC TANK INVERT ELEVATIONS NO LOWER THAN THAT SHOWN) ( _1X SLOPE) (—!—X SLOPS " FOUNDATION- EXIST. - SEPTIC TANK 12' D' BOX 12' LEACHING FACILITY 13.75' BOTTOM TH-1 **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT NO GROUNDWATER FOUND _ 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON H-10 SEPTIC TANK IF NOT SUITABLE. LEGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR (98.4] PROPOSED SPOT EL. TH1 TEST HOLE 2� SLOPE OF GROUND rQ� UTILITY POLE FIRE HYDRANT NOTE; NOT ALL SYYBOL_S MAY APPEAR N TAWING TEST HOLE LOGS ENGINEER: ARNE H. OJALA, PE, SE WITNESS: PHIL RENAUD DATE: NOVEMBi 24, 2009 PERC. RATE = �' 2 MIN/INCH CLASS I SOILS 0" 6" 36" PERC 74" 4 A LS 1OYR 2/1 B MCS 1OYR 5/6 C1 MS 1OYR 6/4 C2 FS 2.5Y 6/4 C3 MS ELEV. 24.0' 21.0' X' X. 123" I 113.75' NO GROUNDWATER ENCOUNTERED 98-357 0 I NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO 11i 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING Te1E LOCATION OF ALL UNDERGROUND do OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. PUMPED H CLEAN V i V GV JV `1V JV � 111 AT .TING )R DRIP LOCUS MAP 1 NOT TO SCALE ASSESSORS MAP 41 PARCEL 55 LOCUS IS WITHIN FEMA FLOOD ZONE 'C" ZONING: R-25 F: 30' S: 15' R: 20' PROPOSED LOT COVERAGE: 22.7% YSTEM DESIGN: RBAGE DISPOSER IS NOT ALLOWED SIGN FLOW. 4 BEDROOMS ® 110 GPD = 440 GPD E A 440 GPD DESIGN FLOW PTIC TANK: 440 GPD (2) = 880 -USE EXISTING 1000 GAL. SEPTIC TANK 4CHING: IES2 (33.5 + 12.83) 2 (.74) = 137 GPD TTOM 33.5 x 12.83 (.74) = 318 GPD TAL' 614 S.F. 455 GPD E (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) M 4' STONE ALL AROUND MA "ROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 7 MAKEPEACE LANE WEST YARMOUTH PREPARED FOR H. TABACHNICK REV. NOVEMBER 2/ 5/ 9 (CALCS SHED) I off 508-362-4541 fax 508-362-9880 downcope.com down cope engineering, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 98-357.D WG(SBO)