Loading...
HomeMy WebLinkAbout150.14.1 - Title 5 Site Plan (3)TOP FNDN. AT EL. 40.0 SLAB AT 9 EL 31.0' \ [' 27.75' SYSTEM FELE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO 31.0' MINIMUM .75' OF COVER OVER PRECAST /- WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM PROPOSED 15QO GALLON SEPTIC TANK (H- 10 ) DEPTH OF FLOW = `I' TEE SIZES: INLET DEPTH m 10" OUTLET DEPTH a 14" FOUNDATION- 12' EGEND RUN PIPE LEVEL FOR FIRST 2' 27.50' Siz7F X26.35' LE 26.52' CRUSHED STONE OR MECHANICAL 4PACT10N. (15.221 [21) (-5-% SLOPE) SLOPE) 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 0 PROPOSED CONTOUR -- 100-- EXISTING CONTOUR oC�000 PROP. RETAINING WALL EST F!OLE LOGS SEPTIC TANK ENGINEER: A. H. OJALA, PE WITNESS: AMY VON HONE, RS DATE: 7/24/03 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. ELEV. 0" 29.0' 0" 33.0' A LS 4"10YR 4/2 E FS 6" 1OYR 5/2 LFS 37" 1OYR 5/6 125.9' C1 MED/COS W/GRAVEL 72" 2.5Y 6/6 120" 03-203 C2 MS 2.5Y 6/4 C2 MS 2.5Y 6/4 19_0 132" 1 NO GROUNDWATER ENCOUNTERED 20' D' BOX 2' DOUBLE WASHED PEASTONE A NOT11i 2. MUNICIPAL WATER IS AVAILABLE LS 4" 1OYR 4/2 E FS Dacus 6" 1OYR 5/2 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH B MASS. ENVIRONMENTAL CODE TITLE V. LFS 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO 30" 10YR 5/6 30.5- C1 S. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. MED/COS W/,GRAVEL A0. 2.5Y 6/6 WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION C2 MS 2.5Y 6/4 19_0 132" 1 NO GROUNDWATER ENCOUNTERED 20' D' BOX 2' DOUBLE WASHED PEASTONE 3/4" TO 1 1/2" DOUBLE WASHED STONE 20' LEACHING FACILITY 3' MAX. 5.17' BOTTOM TH 1 EL.19.0' 1. DATUM IS ASSUMED NOT11i 2. MUNICIPAL WATER IS AVAILABLE DRIVE mmuwl 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 Dacus 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. LOCUS MAF' S. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 3/4" TO 1 1/2" DOUBLE WASHED STONE 20' LEACHING FACILITY 3' MAX. 5.17' BOTTOM TH 1 EL.19.0' 1. DATUM IS ASSUMED NOT11i 2. MUNICIPAL WATER IS AVAILABLE DRIVE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 Dacus 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. LOCUS MAF' S. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. NOT TO SCALE 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION ASSESSORS MAP 150 PARCEL 14.1 OBTAINED FROM BOARD OF HEALTH. LOCUS IS WITHIN FEMA FLOOD ZONE C 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES TOWN OF YARMOUTH VARIANCE REQ'D: TOP FNDN TO PRIOR TO COMMENCEMENT OF WORK. BE 9' BELOW HIGH POINT IN ROAD (11' VARIANCE REQUESTED) 20 LOT 63 r I /41 �87t/ SQ l F1: ! 1 1 o` roo 30.5' ` DECK / D IVEY�AY // /, I 1� �� �/ � 28.5• / /' // /' / / PROP. DWELL 0 TOP FNDN = 40.0 /( 1.0 35.0 a49, 43-.: + 48.8 22.0, SCOTI n= 30' wfi 0 15 30 45 60 75 FEET �-PTIC DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 5 BEDROOMS ® 110 GPD = 550 GPD USE A 550 GPD DESIGN FLOW SEPTIC TANK: 550 GPD (2) = 1100 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES2 (47.5 + 10.83) 2 (.74) = 172 GPD BOTTOM 47.5 x 10.83 (J4) = 330 GPD TOTAL: 746 S.F. 552 GPD USE (5) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) ,M° WITH 2.5' STONE AT ENDS AND 3' AT SIDES APPROVED DATE 9 BOARD OF HEALTH MA PREPARED FOR Y PETER L O 1� SH y RIVE MARCH 25, 2005 off 508-362-4541 BENCH ENTER OF fm 508-362-9880 C. BASIN ELEV. = 48.7 a. down cape engineering, inc. tv ARNE q`yGNm o=` ARNE h CIVIL ENGINEERS Ay LAND SURVEYORS OJFLA 01 �u OIVI� ;�i. (I t ";3`B�'�� N° 92 1 %`p 939 main st. yarmouthport, ma 02675 a 03-203SP.DWG