Loading...
HomeMy WebLinkAbout150.14.1 - Title 5 Site PlanTOP FNDN. AT EL. 46.0' SLAB ON 32.1' 31.75' SYSTEM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO Sc" ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE o� ci ni 33.0' PROPOSED 1500 GALLON SEPTIC TANK (H- 1O ) TEE RUN PIPE LEVEL /-FOR FIRST 2' I 11 BAFFLE 26.52' ppOp�O �LV.JJ �_6" CRUSHED STONE OR MECHANICAL - c COMPACTION. (15.221 [2]) E (2--5-%SLOPE) SLOPE) (-!-% SLOPE) DEPTH OF FLOW = '4 TEE SIZES: INLET DEPTH =, OUTLET DEPTH = 14" FOUNDATION- 12' - SEPTIC TANK LEGEND [100] PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100]- PROPOSED CONTOUR - - 100-- EXISTING CONTOUR LJ PROP. RETAINING WALL TEST HOLE LOGS ENGINEER: A. H. OJALA, PE WITNESS: AMY VON HONE, RS DATE: 7/24/03 PERC. RATE < 22 MIN/INCH CLASS I SOILS LOCKS OR ELEV. Q 0" 29.0' 0" A A LS LS 4" 1OYR 4/2 4" 1OYR 4/2 E E FS FS 6" 10YR 5/2 6" 10YR 5/2 LFS 37" 1OYR 5/6 25.9' C1 MED/COS W/GRAVEL 72" 2.5Y 6/6 C2 MS 2.5Y 6/4 WATER-TEST.D'BOX FOR LEVELNESS 37' D' BOX ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. - CONCRETE COVER TO WITHIN 3" GRADE GEC XTILE 2" DOUBLE WASHED PEASTONE LOCKS OR MORTAR PRECAST RISERS" ISERS COMPON( H-10 _ ) 00I= O F-1 E3 2x•17' o aM OOOO OOD M0=ED =ME7.= 11' 3/4" TO 1 1/2" DOUBLE WASHED STONE LEACHING FACILITY 3' MAX. 5.17' BOTTOM TH 1 EL.19.0' NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE 5. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED' WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND k OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE -MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. ENGINEER TO INSPECT FINAL GRADE Nca 204 g�4. M M n n n /V LOT 1 r r "41,287,& \ i? tv3N 1 I OR 0.45 AC. b \ 1� II rn I / �/ / 5' REMOVAL OF UNSUITABLE SOIL REQUIRED1 I N 28 AROUND PERIMETER OF LEACHING FACILITY, DONT! TO SUITABLE SOIL LAYER. REPLACE CM� 1 / \ � WITH CLEAN MED. SAND, TO MEET t''� I I I I / / �;/ X00,, / 1 / DRICVAIAY SPECIFICATIONS OF 310 R 15.255(3) / / I I `i t. � 1 DECK 9koP. (SWELL *J G'� /1" I A\./ g 3 T P FNDN = 46.0' /'6? �/ // LAB =/ 37' Is L/' r / '/ i?N1'k t / ' �X\ Co 33_0' 2 (43) i 14'X6'�i ' [42 ROC /DRAttJAGE EAgEMEN� ( f I � s - -40'' EMERGENCY ACCESS EASEMENT i r. J` 50' DRAINAGE EASEMENT LFS 30" 10YR 5/6 30.5' C1 MED/COS Wy/GRAVEL 48„ 2.5Y 6/6 C2 MS 2.5Y 6/4 120" I 119_0 132" DCE#11-026 NO GROUNDWATER ENCOUNTERED 22.0' Scale:1 "= 30' 0 15 30 45 60 75 FEET LOCUS MAP NOT TO SCALE ASSESSORS MAP 150 PARCEL 14.1 LOCUS IS WITHIN FEMA FLOOD ZONE C TOWN OF YARMOUTH VARIANCE REQ'D: TOP FNDN TO BE 3.4' BELOW HIGH POINT IN ROAD (5.4' VARIANCE REQUESTED) SEPTIC DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 5 BEDROOMS ® 110 GPD = 550 GPD USE A 550 GPD DESIGN FLOW SEPTIC TANK: 550 GPD (2) = 1100 \ USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES2 (47.5 + 10.83) 2 (.74) = 172 GPD i BOTTOM 47.5 x 10.83 (.74) = 330 GPD 0 o TOTAL: 746 S.F. 552 GPD USE (5) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 2.5' STONE AT ENDS AND 3' AT SIDES P pppjjOVED OCT 25 2011 1 APPROVED DATE MA IBOARD OF HEALTH TITLE 5 SITE PLAN OF Permit valid for REPAIR OF SEPTIC SYSTEM 67 MARSHSID.E DRIVE ' ONLY, due to State and Local septic variances. 7 Board of Health review and approval is required for any future addi/or structurei/dwalterations to YARMOUTH (PORT) sewage facilities and/or structures/dwelling. �O Yarmouth Flealth Department PREPARED FOR APPROVED 1L,511[( M/M GERALD BRINES Mame Date + 4y." MARSHSIDE DRIVE 11 -\0-'Zo1\ DATE APRIL 7, 2011 REV. OCTOBER 1, 2011 REV. NOVEMBER 10, 2011 (NOTES) off 508-362-4541 fax 508-362-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouthport, ma 02675 11-026 McPHEE-BRINES.DWG