Loading...
HomeMy WebLinkAbout22.431 - Site and Sewage Plan (2)FILL .SYSTEM -PROFILE: LOAMY SAND _ 3/2 B MEDIUM SAND NOT TO SCALE FIRST FLOOR TOP OF OF"FOUNDATION 2.85 RAISE COVERS TO WITHIN 6' OF FINISH GRADE MEDIUM 2.5Y ECFV. 13:5 ELEV. 125 -A FINISH GRADE FINISH GRADE SILVER LEAF LANE ELEV, 11,8 ELEV. 12.16 FINISH GRADE SYSTEM DESIGN ELEV. 11.0 GROUND ELEVATION 10.75 TOP = 11 1 ///�� \ h� ��///�� 0/ DESIGN FLOW m "ENGLEWOOD" `' 10'® 2% SLOPE 1 MIN. TOP STONE ELEV 9.92 -3' MAX. COVER 4 BEDROOMS AT 110 GPB/D i,! GPD BROADWAY .. 4" PV 14'® 1,5% SLOPE 2"..MIN 1/8"-1/4" DOUBLE WASHED PEA STOt1E ". 4" PVC SCH 40 O O O O 0 00 O 00 00T�15' ,. SCH 40 INV.= 10.34 INV.= INV.= 2 MI�MAX 10"TEE 14"TEE INV.=9.89 0 00 00 0 00 �0 0 00 X000 00 o I REQUIRED SEPTIC TANK LOCUS Q N O O O O O O O O O O O3/4" DOUBLE WASHED STONE <. 5'-7,• 6„ �00.0000�0000�00000440 x 2 = -----880 GAL. ----------- Sy QRF 4'_61 " /2 GAS BAFFLE 5 OUTLET 20`x30' LEACHING FIELD/3 LATERST IPOUT AROUND SYSTEM TO °C" HORIZON MIN DEPTH SEPTIC TANK PROVIDED = _1500 _GAL. R Q � r: 4'-1" LIQUID LEVEL 4,_4„ / D -BOX INV.=9.69 INV.=9:42 STRIPOUT (30'x40')9.27, BOTTOM OF END OF PIPE SIZE OF LEACHING FACILITY. REQUIRED tiFgs LEWIS <f` `.f: INV.=9.52 77 BOTTOM OF STONE TFR 5 56ELEV DESIGN PERC RATE ___<_2 __MIN./INCH ST BAY , o e " o, o o LONG TERM APPL. RATE-2-2A-GPD/S.F. 6" BASE OF CRUSHED STONE OR MECHANICALLY COMPACTED TEST PIT #1 ADJ. GW. ELEV 3,77 SIZE OF LEACHING SYSTEM PROVIDED: 1,500 GALLON PRECAST TIDAL WATER ELEV. 2.5 CONCRETE SEPTIC TANK 440 _ 0.74 SF/GPD = 895_S.F. MIN. REQUIRED LOCUS MAP NOT TO SCALE: . 1 #18 COLUMBUS AVENUE #14 COLUMBUS AVENUE' USING 20' x 30' LEACHING FIELD ASSESSORS MAP 22 ASSESSORS MAP 22 PARCEL 443 PARCEL 442 BOTTOM 20.0' x 30.0' = 600 S.F. D.T.H. #1 \ DATE: OCTOBER 19, 2005 \ 600 S.F x 0.74 = 444 GPD GROUND ELEV 8.1 \ J G• NO GROUNDWATER ". - - `" N ° CONCRETE BOUND444 GPD PROVIDED > 440 GPD REQUIRED = 4 GPD RESERVE \ I I I 90.00' FOUND & HELD 10.00' FILL A LOAMY SAND 10YR 3/2 B MEDIUM SAND 7,5YR 5/8 ELEV =. 2.85 C MEDIUM SAND 2.5Y 6/2 N47'25'00"E 100.00' B.O.H. NO GARBAGE DISPOSAL / GRINDER ALLOWED 42'' A. VON HONE SOIL EVALUATOR, \ \ \ \ ) \ \ D. MEYERDRAINAGE DEPRESSION \ \\ RO OS PO L F NC 9.5 \1 i/ BACKHOE OPERATOR. \ 9.2 ? /� 48° A & B CANCO " (PER YARMOUTH CONSERVATION OFFICER) / \ \ O� \ PROPOSED _ - LOCUS INFORMATION 52„ SOIL TYPE: 1 _ - - - -, G 10 x14 PERC RATE: <2 MIN. PER INCH / \ SHED / \ \ BUILDING LOADING RATE: 0_74 GAL/SF/MIN CURRENT OWNER M.A. REALTY TRUST 63" j WELL: MIW-29 ZONE: A /-° - - - / -, - - - - - - i NOTES: ADDRESS 4 JANNOR WAY LEVEL: 8.2 / / 0. & FLOOD VENTS TO BE INSTALLED ADJ: 1.7 / ° c ° ° :\•...•; • I - PER ARCHITECTURAL PLANS" WEST YARMOUTH 10. I MA 02673 USE BOH ALLOWED ADJ. OF 1.0' - " w ° ° ° I PLAN REFERENCE PLAN BOOK 25, PAGE 49 PERC. TEST WAIVED _ - 4 - - - - -- - I I ° ELEV (-1.9) 120 BY BOH DUE TO G, W. I EXISTING SEPTIC COMPONENTS TO BE PUMPED, CRUSHED &" REMOVED :FROM DEED REFERENCE DEED BOOK 10468, PAGE 268 I ° ° ; / I SITE IN ACCORDANCE WITH TITLIE 5. - r' PROPOSED ZONING DISTRICT R-25 pip INDICATES DEEP - ° 16'x32' ° I EXISTING IMPROVEMENTS DEPICTED DTH #1 eta TEST HOLE 52" INDICATES ADJUSTED 5 ` / / o POOL: ° HEREON AS DOTTED LINES AR= TO SIDE 15' ° SETBACKS FRONT 30' �® / / o ° ° .......•.•..... ° I BE REMOVED FROM SITE: REAR 20' GROUNDWATER ............. QS i I KS N/F o / ° a i ° I __FLOOD ZONE "A-12"._DATED _7/2/92 INDICATES MICHAEL & JUDITH McKAY- _ / ° 64' INDICATES GROUNDWATER ---- / ° I ............, I I e PANEL X1250015 -5C, ELEV 12.0 P -1A 44 DTES PERC TEST #8 SHORE RD. \� � , ° 1 ASSESSORS MAP 16 / / ;' , PARCEL` 10 / ° a i / / ° ° ,60p. ASSESSORS MAP 22 I - - / I PROPOSED \ I PARCEL 431 ------------ o ° / ° ° 4 BEDROOM \ °,PROPOSED 4 ° ° + DWELLING \ 'I LOT AREA 14,000± S.F. ^ A I TOP FND EL 12.5 o DATUM . APRON ° ; ° ° I I EXISTING BLD/DECK COVERAGE 2,835± S.F. (20%) VERTICAL DATUM: 'NGVD 1929 I \\ 10.0 01- I I PROPOSED BLD/SHED/POOL COVERAGE 2,942± S.F..(21%) 25% ALLOWED I \ I.o BENCH MARK SET: TOP OF D HYDRANT TAG BOLT I \\ 1.1.0 w ELEVATION 9.48 o GENERAL NOTES: I \ PROPbSED RASS AREA I ( t r*i :PROPOS--D 1500 ?. ' DTH #1I 1 1. ALL WORKMANSHIP AND MATERIALS SHALL "CONFORM TO D.E.P. : GALLOi SEPTIC II TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS W I ; i I ;TANK De FOR SUBSURFACE DISPOSAL OF SEWERAGE, 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE o I I S SO I II ACCESSIBLE WITHIN 6" OF FINISH GRADE, WITH ANY REMAINING g I Of ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. \ I l f = ................... ........ PROPOSED I I o 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE N/F \ I I / I; CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY. ARE LILA TYE REV. TRUST \ r 12.0 I GARAGE UNDER OR WITHIN 10' OF DRIVES OR PARKING AREAS THEY #91 MASSACHUSETTS AVENUE \ / I I I; SLAB ELEV 8.5 / o MUST WITHSTAND H-20 LOADING, ASSESSORS MAP 16 \ ( 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION PARCEL 12 I I I N/F OF ALL UTILITIES PRIOR TO ANY EXCAVATION. I12 0 \ _ JON &JACQUELINE SIDOROVICH 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE \ z C/ #81 MASSACHUSETTS AVENUE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. I I E ii I ASSESSORS MAP 22 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER �� I. �i I PARCEL 432 FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. \ I P I 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND - _ _ LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. PROPOSED 20' I \ - - - �� I - _ - - - 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN x 30' S.A.S I 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT (- I' ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES I I 00• o II 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS SOIL REMOVAL 1 I I: z BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC T0. ELEV 2.85 \ 1 4' 6' 6' 4' S �< I. 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE ANDOR TOP OF "C" 5' Io I: (n / SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE I w / LAYER \ I� � JI j FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL A F / BE LEVEL 40ML POLY LINER �w : v 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION ON ALL SIDES \ OS i� 0 TO YARMOUTH B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL WITH RETAINING 13. LAND SURVEY AND TOPOGRAPHIC DATE BY EAS SURVEY. WALL. EL 6 10 TO PRO OSED IN ERL9 KING - CONSTRUCTION NOTES: CONCRETE BOUND CONCRETE BOUNq 5' BL O K RETAIN,�C- WALL �WG- FOUND & HELD FOUND & HELD 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND 71.62' // ( S 7'25'00"W 100:00' ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING �/ I I HYDRANT4y%l. �u 7`� v WORK ON THE SITE. / I WATER MAIN 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE _�.- �.................. I.............,....... L ...:..:.. .. WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3. VEHICULAR TRAFFIC, PARKING OF VEHICLES AND PLACING - - -� - - - 1 L MATERIALS OVER THE SEPTIC TANK, DISTRIBUTION BOX AND S.A.S. AREA IS PROHIBITED MASSACHUSETTS AVENUE 0 10 15 20 30 GRAPHIC SCALE: 1 INCH 10 FEET 50 south Health Department APPROVED X61