HomeMy WebLinkAbout154 Mayflower Terrace - New Construction PlansI IODEL: CAPE, #03353 154 PROJECT SITE: YARMOUTH, MAR TERRACE 'UILDER/PURCHASER: SANbWICH, MA U R N K E Y. E&BARBARA LYMAN . YARMOUTH. TH. MA ISE GROUP: R4 ;ONSTRUCTION TYPE: WOOD FRAME(513) ,REA: 1144 SQ. FT. *Meets MA Code exception ¢,'2 SJ16 I O L U M E: 2 8, 2 7 8 C U. F I (1&2 Family) for construction control BUILDING HEIGHT: 22'-7=3/4" IUMBER OF STORIES: 1 ►ESIGN OCCUPANCY LOAD: 6 ;PECIAL SYSTEMS FIRE ALARM PHOTO ELECTRIC SYSTEM TYPE: SMOKE & CO DETECTORS FIRE SUPPRESSION NA SYSTEM TYPE: OTHER: NA (ESIGN LIVE LOADS ("PSF ALL: 21 FLOOR: 40 ROOF: 40 CORRIDORS: N STAIRS: 100 BALCONIES NA OTHER: NA BUILDING INFORMATION SPECIAL USE PROVISI :CONDITIONS OR LIMITATIONS BUILDING MAY NOT BE LOCATED WITHIN FIRE LIMITS 6'-0" MINIMUM CODE REQUIRED SETBACK FROM LOT LINES WITH 0 HOUR EXTERIOR WALL — B/P SHALL BE .RESPONSIBLE FOR HOUSE LOCATION ON LOT HEATING SYSTEM TYPE: 55 o� HEAT IN A -D ON SITE BY B/P HEATING SYfi`M FUEL: SHALL BE T; E RESPONSIBILITY OF BUILDER URCHASER HEATING SYSTEM CHIMNEY OR VENT T YPE.- SHALL BE THE RESPONSIBILITY OF BUILDER/PURCHASER THIRD PARTY INFORM , T ION PFS Corp. APPLICABLE BU SIG CODES: —MASSACHUSETTS STATE BUILDING CODE 6th EDITION =MASSACHUSETTS FUEL/GAS/PLUMBING CODE -2002 NEC W/MASSACHUSETTS AMENDMENTS —1993 BOCA NATIONAL MECHANICAL CODE W/AMENDMENTS EXTERIOR ENVELOPE THERMAL PERFORMANCE (U. VALUES) SEE ATTACHED RESCHECK COMPLIANCE REPORT TABLE OF CONTENTS DATE 1. ELEVATIONS 11 /26/03 2. FOUNDATION PLAN 3 FLOOR PLAN 4. CROSS SECTION . 5 PLUMBING PLAN ----:- 6 L N 6 ELECTRICAL PLAN . 8. STANDARD NOTES -&-DETAILS­­-- 7 :& DETAILS `7 TOTAL PAGES`4=CO ER-SHEEI APPLICANT'S COPY 2877 Skatetown Road DETEC-ELECTRI TQUIYPE S S,?,!, OKE REQUIRED BY Bloomsburg P A 1781� MASS. STATE BLDG. CODE INSIDE , AND OUTSIDE O ALL BEDROOMS TP I A #27 04/30/04 WITHIN OF A ITCHEN OR BATH. ALL DETECTOR_ MUST HAVE BATTERY BACK -1P. REVI SI N/A This plan must be on site with TOWN OF the permit and the Licensed Construction REVIEWED FOR BUILDING p ANCE. ERRORS OR OMMI' supervisor must be present for all APPLICANT FROM THE RE inspections, 24 Hour notice Minimum, COMPLIANCE, with call back fee. DATE: TOWN OF YARMOUTH auiLDiNac MASSACHUSETTS COVER SHEET restchester Modular Homes Inc Offices and Manufa.eturer Plant ®® 30 P.eagans Afill Poad, iFingda.le, AT, 12594 Tel (845)832-9400 Fax (845)832-6698 Manufacturer No. MCI 16 aF-�nor,N maN m e Expiration Date: 04/30104 ZONING CODE COMPLI-.' NS DO NOT RELIEVE THE ISIBILITYOF "AS BUILT' -, - MAL - STATE LABEL LOCATIONS APP— i_L'.P..I,i=D TO PORT lo FACTO=Y 6U't T 1st FLR DRY BOX— =tea; `s`c %m�y *jM tM 9Jt ENTRY CLOSET c^r •_ 1 st FLR WET BOX— (n UNDER KITCHEN SINK D 3 �s Rr °- ng, GrR� :. ;3,v to F8c,D.v p�;.�. •a?- P • Inspection Agency Label„A -- Ewe * Data Plate is under ''” ••... " 'd kitchen sink on right sid-1 A N (one per unit) I A �►,[ N A N Y REVI SI N/A This plan must be on site with TOWN OF the permit and the Licensed Construction REVIEWED FOR BUILDING p ANCE. ERRORS OR OMMI' supervisor must be present for all APPLICANT FROM THE RE inspections, 24 Hour notice Minimum, COMPLIANCE, with call back fee. DATE: TOWN OF YARMOUTH auiLDiNac MASSACHUSETTS COVER SHEET restchester Modular Homes Inc Offices and Manufa.eturer Plant ®® 30 P.eagans Afill Poad, iFingda.le, AT, 12594 Tel (845)832-9400 Fax (845)832-6698 Manufacturer No. MCI 16 aF-�nor,N maN m e Expiration Date: 04/30104 ZONING CODE COMPLI-.' NS DO NOT RELIEVE THE ISIBILITYOF "AS BUILT' -, - MAL - =NSION (* JSE WIDTH 00 -0"/30'-0 27'-8'/31'-8" 0 Z am <w o -�- I- IK 11" 16" �t- N JJ 11" 16" C.9 Q coui lL >>- 11" 12" of 3 3/4" 8 3/4" OZ QU Q � M v U J rr �jj � LLI *DELETE SIDING* Qa Q g �O Q c� Lot SOFFIT BY ALL EXT.STAIRS, STEPS, RAILS & GUARDS TO BE DESIGNED, SUPPLIED AND INSTALLED BY B/P FRONT ELEVATION SCALE: 1/4"=l I-oll -LEVATION I I REAR ELEVATION SCALE: YWMH BY 1 _ w cnN to t/7 t Z QJ 'i N m E> -co o Lo < = m 00 a w i Zco m [�LP S rn B 4.25�® o J w m} �C rn I N F- co LJ -�Lo M U N� Q��v � O o �M� W Li Q 8 ~O 1 m N Z ~ —1 z O U 12 WN of �� z OfN(n RIGHT ELEVATION U oLLJ LLLL n SCALE: 1/8"=1'-0" o~ cf) Ll I� d� QI_� �v 9 00 �1-- am <w o -�- I- IK �t- N JJ -i-D TI. coui lL >>- of 2� QU Q � M v J � _ w cnN to t/7 t Z QJ 'i N m E> -co o Lo < = m 00 a w i Zco m [�LP S rn B 4.25�® o J w m} �C rn I N F- co LJ -�Lo M U N� Q��v � O o �M� W Li Q 8 ~O 1 m N Z ~ —1 z O U 12 WN of �� z OfN(n RIGHT ELEVATION U oLLJ LLLL n SCALE: 1/8"=1'-0" o~ cf) Ll I� d� QI_� �v 9 m5f Ni Q ril CTC2T A41 T 243 44VEN '—O" 2432T CN235 HOOD 3-3046 W 3072 - - T;OCHEN CAR m e7s ns7s NOOK SBW 11'-8" x 12'-6" M sOMTS"T n n I 13'-0" x 12'-2 1/2" 'o o_X >n Ll [2] 1 1/2" x 91 MICRoLAM - 2ND FL [4] 1 1/2" x 9 1/4' MICP.OLAM - 2ND FLL�_comow DECK BY B/P D30 - - - - e 0.4 0 �0 I �L) m GTOP m S83" pCADET 3 PIN RAFTERS CATHEDRAL " °' . AREA ILIGHT SUPPLIED CAPELLA 51 .2=DR00M II HYDRO TUB 19.79 ING R 0 0 M ° xoao V48 W 146 O 17.19 W C 159 8.0 <V PD26 C , cco II 0 a� SE I 44VEN '—O" 2432T CN235 HOOD 3-3046 W 3072 - - T;OCHEN CAR m e7s ns7s NOOK SBW 11'-8" x 12'-6" M sOMTS"T n n I 13'-0" x 12'-2 1/2" 'o o_X >n Ll [2] 1 1/2" x 91 MICRoLAM - 2ND FL [4] 1 1/2" x 9 1/4' MICP.OLAM - 2ND FLL�_comow DECK BY B/P D30 - - - - e 0.4 0 �0 I �L) m GTOP m S83" pCADET 3 PIN RAFTERS CATHEDRAL " °' . AREA ILIGHT SUPPLIED [2] 1 1/2" x 9 1/4" MICROLAM 51 .2=DR00M II - 19.79 ING R 0 0 M I 158 xoao 0 DK 146 30.9 17.19 W C 159 8.0 <V Q co cco II 0 a� I LIVING ROOM �v MSTR BEDROOM 0 i o ?3'-9" x 11'-6" 17'-11 1/2" x 12'-2 1/2" a I l m 1 2-3046 3-3046 12'-7 1/2" NOTE: INSTALL BASE TRIM IN CARPET AREAS S/L BASE TRIM FOR LINO AREAS IN FULL LENGTHS PAINTED ICHT & 6'-9 1 7' -4- z VENTILATION SCHEDULE (SF) R( 0M AREA ILIGHT SUPPLIED VENT SUPPLIED 51 .2=DR00M 219 I 39.5 19.79 ING R 0 0 M I 158 I 29.2 14.06 DK 146 30.9 17.19 CHEM 159 8.0 7.20 Q co 6'-9 1 7' -4- z Q z a. az O� 0 I -- °Z SY L 4L F- Luo ~(L om oN 00 U .� JJ J � as m Q co cco a� Q •. a...... ------- a. az °Z SY m F- <C �0 co 011111 -1110 z . 1 w C.1)--tco �u� cni I ZCD i N Q >- co Q m 1!') a =z� >r co D0 zitz: STx zQ aa m W a cp (n o N Lu -> ® I (V� C/) MCU Ld c Lr) U 0 "t � N o co N O M H 0 �' ®® z _ ®® z�� Q � � ooCNQAW z = N (n Q o LLI mo LLJ cf) z aE�" �� U� 44'-0" SHED 2-3046 2432 BEDROOM 2 15'-8" x 12'-6" > o I G M t7 , CHASE j KD30 24'x24" ! ; [2] 1 1/2" x 14" MISD- ROOF Nn OF4 P SO T POST — 6 1fl ----------- , I I 1 I ------------ I BE40 I o 0": SITTING ROOD,, ON 15-3 1/2" x 8'-4" r� 0 10,—l" 3— '-0" SHED DORMER 12'-5 1/2" LOFT 16'-5" x 12'-0" � Z N W � Z OST [1] 1 1/2' x 14" MICROLAM — ROOF ---------- 2'-8" 6'-9 1/2" , SUGGESTED 2nd.FLOOR LAYOUT ONLY All design and construction of 2nd.floor is the -on site responsobility of the builder and must be completed in accordance with local building code and inspection procedures. State approval of this project only pertains to the modular units as provided by Westchester Modular Homes Inc. IGHT & VENTILATION SCHEDULE (SF) ROOM AREA LIGHT SUPPLIED VENT SUPPLIED (ROOM 2 196 41.2 22.92 ING ROOIJ 127 30.9 17.19 : 00 J J cc I � I � ---------- 14'— tDc O �� DECK fa3 BY B/P 2R 00 wx w� N W ~a : 00 J J cc J� Qn". Lt1 � >r n O >r ft C) o_ QQ u_ 2R fail J V�Ca 0) to C41 i 2i N E 03 O ^ S m� �w z Co 00 Q rQ aax M 0 I� M a ��o�� o 5 0 D a� Dorn (3> � -}__N Fa �LL cr>_�CO WLD r c^ N � Cn OO O LLJ I-) Q 12 �U ®® ~_ z �� D ZOU �0 o C/ -)o � o�Q Z m ofNIn QLo 5. o LLJ LL, Elf in 0 ol� oV N �� 00 oa: w� N W ~a : 00 cc Qn". a occ Mo fail J V�Ca 0) to C41 i 2i N E 03 O ^ S m� �w z Co 00 Q rQ aax M 0 I� M a ��o�� o 5 0 D a� Dorn (3> � -}__N Fa �LL cr>_�CO WLD r c^ N � Cn OO O LLJ I-) Q 12 �U ®® ~_ z �� D ZOU �0 o C/ -)o � o�Q Z m ofNIn QLo 5. o LLJ LL, Elf in 0 ol� oV N �� CERTIFIED ROOF TRUSS DESIGN 12 - 425 - CONT RIDGE VENT TYP ROOF 18 SO IN/LF 30YR SELF–SEALING FIBERGLASS SHINGLES F : OVER 15# ROOFING FELT OVER 5/8" AGENCY RATED SHEATING BITUTHANE APPLIED CONTINUOUSLY 12 TO EAVES FOR ICE SHIELD 4.25 2x6 ep,/2 COLLAR E FASTEN M7TH (6) i6E AT EACH END ON TOP CHORD - 12 TYP INTERIOR WALL / 'q12 [2) 2x4 SPF #3 TOP PLATES 2x4 SPF #3 016" OC STUDS AIR BAFFLE BY WMH 2x4 SPF #3 SOLE PLATE Ns�k/nONCEBY w oNLr1/2" GWB BOTH SIDES INsv WIAH 1x6 SUB–FASCIA 12" FIBERGLASS BATT / KRAFT BACK R30 INSULATION , �ALUMN SOFFIT TYP EXTERIOR WALL 2x10 SPF/2 @,e o.c / [2] 2x6 SPF #3 IDP PLATES / SOFFIT .75 IN2 /FT VENT 2x6 SPF #3 ® 16" OC STUDS 2x6 SPF #2 SOLE PLATE N_ 1 /2" GWB SIDE 7YP MARRIAGE WALL [2] 2x3 SPF #3 TOP PLATES 6" FIBERGLASS INSULATION R19 KRAFT BACK 2x3 SPF #3 STUDS ® 16" O.C. 8>J'/16_� q (MA only –STAPLED TO STUDS (9 7" O.C.) 1 2" AGENCY RATED SHTG. AT MAT -SIDE x ° 1/2" AGENCY RATED SHEATHING AT EXT.SIDE / 1/2" GWB INTERIOR SIDEmj _ AIR INFILTRATION BARRIER 2x3 SPF #3 SOLE PLATE e : VINYL SIDING 3 TTP. SUB–FLOORING / r 3/4" T&G PLYWOOD /� m 2x6 PT SILL PLATE @ 15 OC FLR JST 2x10 SPF #2 g 16" OC FI JST t —� DBL 2x i 0 SP;_ n 1 (SUPPLIED & INSTALLED BY B/P). R-19 FIBERGLASS INSULATION W/ KRAFT BACK VAPOR BARRIER TO COMPLY W/ENERGY CODE INSTALLED & SUPPLIED BY B/P SEE STD. NOTES DVdG #&�, mi t9 c Ld s 745/16 m tl -- 'o ` SJPPORTS E & STAIRS owd MICROLAM BEAM. ROOF PITCH MAY VARY—>SEE 12 PIN RAFTER ELEV. DWG tt CROSS SEC110N SCA' `: 1/4.1•-0. 1 @2� AIR 13AFFLE ,Q aG ft BY WMH ANGLE BRAKET @ EACH SIDE OF RAFTER/ 1/2• R3DC INSULATION DIAMETER BOLT 7HRU R W/ VAPOR BARRIER (2) 4•x 3/8• BOLTS TO TOP PLA 1x8 SUB FACIA VINYL SOFFIT 2D IN/SO LF VENT = �\ \-R-19 FIBERGLASS INSULATION 70 COMPLY W/ENERCY CODE (INSTALLED BY B/P W/VAPOR BARRIER TO WARM SIDE) Q p O0 F wo U d(3 d o r= o� _ j CC cv J — Z cc to Qa p 0 IF - a. o V - 0 F OO nOf FW_- d ¢ � _ Im e Z Olt 3 xo a. IYO N Z 1tl^. DID o 0 04) Z Y O U N w W U V -4p co � cm N z QJ `0 M 0Of�-c) 3� K — = Z � A ■ _01 co QDO o� o <o W -CD -E / /� o (n ® U `o ¢ v J < C J w �r Q Q> O a> = In QJ � (n O O M Q t- LLJ 0 Ld Ld O ®® ®® z �� D � Q z O N LO Qtai �1 CDa In Lij CJ ( - c� ��h 4 v) a mCD L4 2"D HYDRO TUB o LAV N SHO r WASHER] 1 1/2" y0 DWU DIAGRAM VIEW `A' - NTS D = DRAIN V = VENT FV = FUTURE VENT SP = STAND PIPE DW = DISH WASHER WC = WATER CLOSET FC = FIELD CONNECTION BY B/P B/P = BUILDER/PURCHASER -4. C C'4 WC � �♦ DW > 30 Z w KIT SINK 4 V R oi rFC !"D 14' HYDRO TUB WC LAV I I I FL I I i I 1 MASTER BATH ._____• DRAIN BY BP KIT BY WMH >FI WASHER WC LAV SINK DW I oa o o ��•� I I I I I ! I I ! I I ! I TYp I I 1 I I HALF BATH i KITCHEN I ._____• DRAIN BY BP �...... DRAIN BY WMH VENT BY BP VENT BY WMH SUPPLY DIAGRAM VIEW `A' - NTS FL = FLOOR LINE = 1/2" SHUT OFF VALVE COLD ------- HOT z V 00 t_ F W elf uurr 0+ oa o o ��•� Q N co OO V o OC _ w O r -r CL as u oo - IL r - M O ,cc LL z V ao t_ F W elf uurr F- M o *`d„rrru SES o ��•� co o OC _ w O �� Z CL u rr'rrrrr rr•.ta V I M co o 0 I I O - M O ✓ 0 2 Y S v � '3. ro co Q cnZ Q7 y CV Q E }- �— 3 OLo = z v' co a� ¢ ¢ r L7 co m =Q ®� z v X rnO O c La n < o !`ft1 � V) n 2 < 71_1 i z °' Q L7 co H W � � o � n r7 ® v o L0 U) N 00 O P113 O ~®® r z Li UOU Q- Ag zcoo n ¢ooz` nava v AF Z m QfN( n Q O o LLJ W WLL_O� Ni �; L � al �' I 0 ui-X7 ------------ 44'-D" BY 6/P A`r200 A r UNDER CAB ELECTRICAL PANEL cFl ;" LIGHT PREP LOCATION - BSMT Room• ag 1!1 If��>•�o F MSTR BEDROOM pi Fl 4 LOCATE OUTLET TO FLOODS S:- TEL NOOK FAN F 6 4 _ — 4 DECK BY B/P 60 AFF 1 rel. e19 'SLl LIVING ROOM I 10 �— dA I 10 ecc ---- MAR - -_MAR 1 8 ?--A I APPROVAL uWI:TM_ TC ACTORY BUILT POS'"` v 41 . Q. U) }Z Q DIRECTORY 00 LEGENDCIRCUIT CIRCUIT WIRE AMP NO. » PANEL BOX NO. AMP WIRE CIRCUIT KITCHEN COUNT. 12-2 20 2 a� TIDv DUPLEX REcEPTtcAL 1 4 8-4 RANGE KIT CTR,KIT,NODK 12-2 20 4 IR 71DV DUPLEX RECEPTCAL - SPLIT WIRED 3 Q m GL-KIT,NOOK 14-2 15 6 Cc = v 22OV RECEPTICAL 5 1 20 I12 -2I REFRIGERATOR I AFI 114-21 15 8 KD WALL uGHT 7 1 15 114-2I GL—KIT, MBATH, WIC I GL—MBED, SD 15 110 LL Z^, C9LRrG UCHT SURFA".E MOUNTED I o 1 15 14_ I 2I GL -ENTRY, HBA -1H GL -LIVING ROOM 14-21 12 O R c s� ucNT AT MUNE 11 20 12-2 GAS DRYER WASHER 12-2 20 14 SNITCH. SIN= POLE WAY 13 20 12-2 DISHWASHER BATH GFI'S 12-2 20 16 ..r •+- SWITM THREE SW r;FL FOUR WAY 15 20 12-2 HYDRO TUB 6FI ,s � FAN/UCHT FIXTURE LTJ RAN.l-,tHDOD FIXTURE 17 I I 120 �� .',=(,t� FAN/'JOHi d' HEAT CFIJNG UNIT 19 I I I 22 U �' S�E�A! >UR�Qi CONNECTION 21 1 I I I I 24 a' PJNCION BOX 23 I I I 26 I:M) A=/DC SMOKE DETECTOR 1 25 I I I 26 e BE.., 127 I i 30 �' DO}. c BUTTON. 129 I I I 32 d TELEPHONE OUTLET 31 I 34 -j= T=V.SDN CABLE OUTLET I C) THERMOSTAT 33 36 0(0 VACUUM SYSTEM OUTLET 35 38 CEIUNC FAN A UCHT37 40 O CEIUNC FAN 10 ecc ---- MAR - -_MAR 1 8 ?--A I APPROVAL uWI:TM_ TC ACTORY BUILT POS'"` v 41 . Q. U) }Z Q tP " W < ET , to Q G') ! QJ YN z ¢ r0 _1 � C = Z Do C [fj ¢ DO I Q m Cn • i �� U 0300 <��. 001 N Q Do W Lo _ W o Lo U of Lo N 0 �y LC) I."LJ Q> N O O O I'll H Q —� 0 LJ L) (n AFA Q QDJZ o�Q LLI (n Z 00 Lu O < H a \���S�T1S bv;'', a� bvZ IR Q m '- w Cc = v ¢ CL wpIL a 4L) LL tP " W < ET , to Q G') ! QJ YN z ¢ r0 _1 � C = Z Do C [fj ¢ DO I Q m Cn • i �� U 0300 <��. 001 N Q Do W Lo _ W o Lo U of Lo N 0 �y LC) I."LJ Q> N O O O I'll H Q —� 0 LJ L) (n AFA Q QDJZ o�Q LLI (n WINDOW SCHEDUL Z�,:a J-- _ --------- ANULIJSEN --iic: Iiia- -..-...----- 01- IILi 5.0 --6-2 5.1 2F346 _ANDERSEN UC IILT 9.0 1856 ANDERSEN UC IILi 11.2 �C)�1 ANDERSEN UC LILT 6.9 Electric service shall be grounded by B/P In compliance with NEC, stale and local All ANDERSEN DC JILT 10.3 305G ANDERSEN UC IILT 12.9 4l e ANDERSEN UC IILT 11.7 13. ANDERSEN DC IILT 14.13 �D446 iFi ANDERSEN OC 11LT- DAY 21.7 ltd- 1146 115 ANDERSEN DC _11LI- PICTURE 25.9 8. ANDERSEN CASEMENT 8.0 1. Label locations are designated by: F-s'll Slate Labels IA I Third Party Inspection Agency f-L)-Pl Data Plate 2. Maximum height of egress window sills is S-6" Above Finished Floor 3. Refer to order selection form for specific appliances supplied with this house. 4. Bath room fans are rated at 50 CFM. 3.02 3.02 2.94 5.05 5.05 3.85 5.73 5.73 6.41 2.45 6.04 7.40 177/8"x2.41/4"=3.0I SF 1778"x241/4"=3,01 SF 25 7/8" x 16 1/4" = 2.92 SF 29 7/8" x 24 1/4" = 5.03 SF 29 7/8" x 24 1/4" = 5.03 SF 33 7/8" x 16 i/4" = 3.82 SF 33 7/8" x 24 1 /4" = 5.70 Sr 33 7/8" x 24 1/4" = 5.70 SF 37 7/8" x 24 1/4" = 6.38 SF 37 7/8" x 24 1 /4" = 6.38 SF 37 7/8" x 24 1/4" = 6.38 SF 17 7/8" x 24 1/4" = 3.01 SF 10 3/16" it 3S 15 /1 G" - a n cr FLOOR PLAN NOTES 5. Attic Access(es) on Cape Models are to be done on site by Builder Purchaser. 6. If applied, any part to be finished by builder on site, shall be in compliance with all applicable building code requirements and under jurisdiction of the local building inspector. ( garage, additions, porch, etc ) SUPPLY NOTES 1. Materials are type L copper and lead free solder. 2. Water supply shall be securely attached to the buildingg at no greater distances between support Intervals than specified Horizontal pipe at 6'-0" Vertical pipe at each story. 3. Water healer to be supplied and installed by B/P. 4. All supply lines are stubbed through the first floor. Supply lines below first floor supplied and installed by B/P. 5. All hot water lines in unhealed spoces shall be insulated by B/P. 6. All tubs and/or showers to be supplied will, anti -scald valves 7. All devices installed will self closing valves (i.e. washer,dishwasher) shall have a water hommer arresling device on the supply line supplied and installed by B/P on site, in accordance with if Slate and local applicable codes. 8. All fixture supply lines 1/2" diameter shall have individual shut off valves. - 7: All interior and exterior Handrails and/or Guardrails are installed by Builder/Purchaser DWV NOTES 1. Materials are PVC schedule 40. 2. Drainage and Vent piping shall be securely attached to the building at no greater support Intervals than specified. Horizontal pipe at 4'-0" for 02" or larger Horizontal pipe at 3'-0" for 01 1/2" or smaller Vertical pipe at 4'-0". 3. All drainage connections horizontal to horizontal and vertical to horizontal ore long sweep or double 45 fillings. 4. Horizontal vent pipe connections to vertical vent branch or stack shall occur at least 6" above the floor rim. of the highest fixture served by the horizontal vent. EXTERIOR DOOR .SCHEDULE DOOR NO _ DOOR Sl ZIE D OR TYPE 1)X26 DX30 OX301 DX302 DX60 PS -6 WE 5-6 2'-8" 3'-O" 3'-O" 3'-O" 2 3'-O" 3'-O" x x X x 3'-0" x x 6'-8" 6'-8" 6'-8" 6'-8" x 6--8" 6'-9" 6'-7" INSULATED, METAL, 9 LIGHT INSULATED, METAL, 6, PANEL INSULATED,METAL66PANEL+ISLIGHT INSULATED, METAL, 6PANEL+2SLIGHT INSULATED,METAL,DOUBLE,lSLIGHT WOOD, SLIDING GLASS DOOR WOOD, SLIDING GLASS DOOR 11. One (1) GFI circuit shall be installed In basement by B/P. 4. 5. Electric service shall be grounded by B/P In compliance with NEC, stale and local All codes. 12. A clothes washer circuit shall be installed in basement by B/P if washer location is not incorporated electrical components shall be listed and/or labeled by a nationally recognized be testin lab and into house. 6. shall installed in accordance with manufacturer instructions and locations/use Electric 9 instructions. 13. Receptacles shall not be installed directly over electric baseboard heaters. 7. In ba pone) shall be located and mounted In basement by B/P, unless noted otherwise. A 14. circuit breakers for electric baseboard heaters are only installed In panels of houses with electric service disconnect shall be Installed at a readily accessible location nearest the entrance the o P affil f 15. baseboard systems. Smoke 8. of service conductors. Telephone detectors are Interconnected and Installed on a lighting circuit with no intervening switches on 9. and television cable options run to the electric panel location.that Door bell circuit. wires shall be connected in basement by B/P. 16. 17 Smoke detectors shall have a battery back-up power source. B FLOOR PLAN NOTES 5. Attic Access(es) on Cape Models are to be done on site by Builder Purchaser. 6. If applied, any part to be finished by builder on site, shall be in compliance with all applicable building code requirements and under jurisdiction of the local building inspector. ( garage, additions, porch, etc ) SUPPLY NOTES 1. Materials are type L copper and lead free solder. 2. Water supply shall be securely attached to the buildingg at no greater distances between support Intervals than specified Horizontal pipe at 6'-0" Vertical pipe at each story. 3. Water healer to be supplied and installed by B/P. 4. All supply lines are stubbed through the first floor. Supply lines below first floor supplied and installed by B/P. 5. All hot water lines in unhealed spoces shall be insulated by B/P. 6. All tubs and/or showers to be supplied will, anti -scald valves 7. All devices installed will self closing valves (i.e. washer,dishwasher) shall have a water hommer arresling device on the supply line supplied and installed by B/P on site, in accordance with if Slate and local applicable codes. 8. All fixture supply lines 1/2" diameter shall have individual shut off valves. - 7: All interior and exterior Handrails and/or Guardrails are installed by Builder/Purchaser DWV NOTES 1. Materials are PVC schedule 40. 2. Drainage and Vent piping shall be securely attached to the building at no greater support Intervals than specified. Horizontal pipe at 4'-0" for 02" or larger Horizontal pipe at 3'-0" for 01 1/2" or smaller Vertical pipe at 4'-0". 3. All drainage connections horizontal to horizontal and vertical to horizontal ore long sweep or double 45 fillings. 4. Horizontal vent pipe connections to vertical vent branch or stack shall occur at least 6" above the floor rim. of the highest fixture served by the horizontal vent. EBB - HEATING NOTES I. Electric baseboard healing circuits are 20 Amp, 220 Volts with 12-2 non-metallic sheathed cable type NM -B. 2. Maximum wattage per circuit shall be 3750 walls. 3. Baseboards are rated at 250 watts per linear foot. 4. Minimum thermostat range Is 45' to 75' F. 5. General lighting receptacles shall not be located above electric baseboard healing units. FOUNDATION NOTES I. The foundation plan is provided for foundation design parameters onlconditions, applicableete foundation local andlstateneodes,,dtonbepeviewedsite and approved by a registered architect or engineer in the slate of house designation. 2. The Builder/Purchaser shall be responsible for design, construction and code compliance of all foundation elements Including (but not limited lo) structural, plumbing, electrical, heating, energy conservation and fire separation. 3. Minimum column fooling size shall be 2'-6" x 2'-6" x 10" deep. 4. Concrete strength shall be 300033pPsi or greater.5. PP G. vandal on sillcolumn ) shlall be preservative l leafed elumber supplied and installed by B/P prior to house delivery and set). here shall be no protrusion above top of sill plates. asemenl smoke detectors are supplied by WMH and Installed by B/P. FHW - HEATING NOTES 1. Baseboard ratings are based on 190' F water temperature at 1 GPM flow rate with 65' entering air. 2. First floor baseboard units are Installed with heating pipes slubged thru floor. Second floor heating pipes between baseboard units are Installed in floor and/or wall panels. B/P Is responsible for interconnection between modules and floors. Balance of heating system Is to be designed, supplied and Installed by B/P. 3. All heating pipes In unheated spaces shall be Insulated by B/P. 4. Minimum thermostat range is 45' to 75' F. S. Access panels are for the Builder/Purchaser to use In the Interconnection of the healing system. These panels may be permanently attached and finished over by B/P after heating system is completed PERIMETER BEAM (2) 2x10 SPF #2 x EACH MODULE for or rota wnu v � z 2x6 SILL PLATEA a o" a: 32 Z 0 O $ i z v 1 FDTN WALL V)co .r Q a K LALLY COLUMN--- � COLUMN FTG 01/2" BOLT & NUT ra' OF esut sl.Aa & WASHER 032"OC +,STEEL PLATE & LAG FDTN FTG BOLTS BY B/P LALLY COLUMN �� RDA INC I. " � U" PE RA EDWARD & BARBARA LYMAN �� Ys -T TYPE:tRO30 �1tE� APPROVAL LIMITED TO JVO11D A 02563 Qf� Ko= FACTORY BUILT PORTION 154 MATFLOWER TERR. YARMOUTH, MA 5�ND.A.RD 1��oo>rR�tC ,1 IAN DA1EILL NCSTES` ,,,,,i11, nury,vpF ''4„ ED-ET �L - `,aaURTA�9�: A. STEN G'? 1 31 Westchester Modular Homes Inc DATE ; Jpr� kANGPRa`4`�c'; 30 Reogons Mill Road, Wingdale, New York, 1259¢ Fss �w Tel (914)832-9400 Fox (914)832-6698 �-- rorinl - THOM b' tAJEIC 05-06-03 '''",rn,nnna,,•a, 3 PARTY APPROVED PFS CORP MAR 1 1 2004 APPROVAL LIMITED TO FACTORY BUILT PORTION i. , I ELECTRICAL NOTES 1. Electrical panel is rated 200 amps. 10. Door bell button at split entry front doors shall be Installed by B/P 2. Non-metallic sheathed cable Is type NM -e. 3. Wires ore installed with insulated staples. 11. One (1) GFI circuit shall be installed In basement by B/P. 4. 5. Electric service shall be grounded by B/P In compliance with NEC, stale and local All codes. 12. A clothes washer circuit shall be installed in basement by B/P if washer location is not incorporated electrical components shall be listed and/or labeled by a nationally recognized be testin lab and into house. 6. shall installed in accordance with manufacturer instructions and locations/use Electric 9 instructions. 13. Receptacles shall not be installed directly over electric baseboard heaters. 7. In ba pone) shall be located and mounted In basement by B/P, unless noted otherwise. A 14. circuit breakers for electric baseboard heaters are only installed In panels of houses with electric service disconnect shall be Installed at a readily accessible location nearest the entrance the o P affil f 15. baseboard systems. Smoke 8. of service conductors. Telephone detectors are Interconnected and Installed on a lighting circuit with no intervening switches on 9. and television cable options run to the electric panel location.that Door bell circuit. wires shall be connected in basement by B/P. 16. 17 Smoke detectors shall have a battery back-up power source. B EBB - HEATING NOTES I. Electric baseboard healing circuits are 20 Amp, 220 Volts with 12-2 non-metallic sheathed cable type NM -B. 2. Maximum wattage per circuit shall be 3750 walls. 3. Baseboards are rated at 250 watts per linear foot. 4. Minimum thermostat range Is 45' to 75' F. 5. General lighting receptacles shall not be located above electric baseboard healing units. FOUNDATION NOTES I. The foundation plan is provided for foundation design parameters onlconditions, applicableete foundation local andlstateneodes,,dtonbepeviewedsite and approved by a registered architect or engineer in the slate of house designation. 2. The Builder/Purchaser shall be responsible for design, construction and code compliance of all foundation elements Including (but not limited lo) structural, plumbing, electrical, heating, energy conservation and fire separation. 3. Minimum column fooling size shall be 2'-6" x 2'-6" x 10" deep. 4. Concrete strength shall be 300033pPsi or greater.5. PP G. vandal on sillcolumn ) shlall be preservative l leafed elumber supplied and installed by B/P prior to house delivery and set). here shall be no protrusion above top of sill plates. asemenl smoke detectors are supplied by WMH and Installed by B/P. FHW - HEATING NOTES 1. Baseboard ratings are based on 190' F water temperature at 1 GPM flow rate with 65' entering air. 2. First floor baseboard units are Installed with heating pipes slubged thru floor. Second floor heating pipes between baseboard units are Installed in floor and/or wall panels. B/P Is responsible for interconnection between modules and floors. Balance of heating system Is to be designed, supplied and Installed by B/P. 3. All heating pipes In unheated spaces shall be Insulated by B/P. 4. Minimum thermostat range is 45' to 75' F. S. Access panels are for the Builder/Purchaser to use In the Interconnection of the healing system. These panels may be permanently attached and finished over by B/P after heating system is completed PERIMETER BEAM (2) 2x10 SPF #2 x EACH MODULE for or rota wnu v � z 2x6 SILL PLATEA a o" a: 32 Z 0 O $ i z v 1 FDTN WALL V)co .r Q a K LALLY COLUMN--- � COLUMN FTG 01/2" BOLT & NUT ra' OF esut sl.Aa & WASHER 032"OC +,STEEL PLATE & LAG FDTN FTG BOLTS BY B/P LALLY COLUMN �� RDA INC I. " � U" PE RA EDWARD & BARBARA LYMAN �� Ys -T TYPE:tRO30 �1tE� APPROVAL LIMITED TO JVO11D A 02563 Qf� Ko= FACTORY BUILT PORTION 154 MATFLOWER TERR. YARMOUTH, MA 5�ND.A.RD 1��oo>rR�tC ,1 IAN DA1EILL NCSTES` ,,,,,i11, nury,vpF ''4„ ED-ET �L - `,aaURTA�9�: A. STEN G'? 1 31 Westchester Modular Homes Inc DATE ; Jpr� kANGPRa`4`�c'; 30 Reogons Mill Road, Wingdale, New York, 1259¢ Fss �w Tel (914)832-9400 Fox (914)832-6698 �-- rorinl - THOM b' tAJEIC 05-06-03 '''",rn,nnna,,•a, 3 PARTY APPROVED PFS CORP MAR 1 1 2004 APPROVAL LIMITED TO FACTORY BUILT PORTION i. , I