HomeMy WebLinkAbout154 Mayflower Terrace - New Construction PlansI
IODEL:
CAPE, #03353
154
PROJECT SITE: YARMOUTH, MAR TERRACE
'UILDER/PURCHASER: SANbWICH, MA
U R N K E Y. E&BARBARA LYMAN .
YARMOUTH.
TH. MA
ISE GROUP: R4
;ONSTRUCTION TYPE: WOOD FRAME(513)
,REA: 1144 SQ. FT.
*Meets MA Code exception ¢,'2 SJ16
I O L U M E: 2 8, 2 7 8 C U. F I (1&2 Family) for construction control
BUILDING HEIGHT: 22'-7=3/4"
IUMBER OF STORIES: 1
►ESIGN OCCUPANCY LOAD: 6
;PECIAL SYSTEMS
FIRE ALARM PHOTO ELECTRIC
SYSTEM TYPE: SMOKE & CO DETECTORS
FIRE SUPPRESSION NA
SYSTEM TYPE:
OTHER: NA
(ESIGN LIVE
LOADS ("PSF
ALL:
21
FLOOR:
40
ROOF:
40
CORRIDORS:
N
STAIRS:
100
BALCONIES
NA
OTHER:
NA
BUILDING INFORMATION
SPECIAL USE PROVISI
:CONDITIONS OR LIMITATIONS
BUILDING MAY NOT BE LOCATED
WITHIN FIRE LIMITS
6'-0" MINIMUM CODE REQUIRED
SETBACK FROM LOT LINES WITH
0 HOUR EXTERIOR WALL — B/P
SHALL BE .RESPONSIBLE FOR
HOUSE LOCATION ON LOT
HEATING SYSTEM TYPE:
55 o�
HEAT IN A -D ON SITE BY B/P
HEATING SYfi`M FUEL:
SHALL BE T; E RESPONSIBILITY
OF BUILDER URCHASER
HEATING SYSTEM CHIMNEY
OR VENT T YPE.-
SHALL BE THE RESPONSIBILITY
OF BUILDER/PURCHASER
THIRD PARTY INFORM , T ION
PFS Corp.
APPLICABLE BU
SIG CODES:
—MASSACHUSETTS STATE BUILDING
CODE 6th EDITION
=MASSACHUSETTS
FUEL/GAS/PLUMBING CODE
-2002 NEC W/MASSACHUSETTS
AMENDMENTS
—1993 BOCA NATIONAL MECHANICAL
CODE W/AMENDMENTS
EXTERIOR ENVELOPE THERMAL
PERFORMANCE (U. VALUES)
SEE ATTACHED RESCHECK
COMPLIANCE REPORT
TABLE OF CONTENTS DATE
1. ELEVATIONS 11 /26/03
2. FOUNDATION PLAN
3 FLOOR PLAN
4. CROSS SECTION .
5 PLUMBING PLAN ----:-
6
L N 6 ELECTRICAL PLAN .
8. STANDARD NOTES -&-DETAILS--
7
:& DETAILS `7 TOTAL PAGES`4=CO ER-SHEEI
APPLICANT'S COPY
2877 Skatetown Road DETEC-ELECTRI TQUIYPE S S,?,!,
OKE
REQUIRED BY
Bloomsburg P A 1781� MASS. STATE BLDG. CODE INSIDE
, AND OUTSIDE O ALL BEDROOMS
TP I A #27 04/30/04 WITHIN OF A ITCHEN OR BATH.
ALL DETECTOR_ MUST HAVE
BATTERY BACK -1P.
REVI SI
N/A
This plan must be on site with TOWN OF
the permit and the Licensed Construction REVIEWED FOR BUILDING
p ANCE. ERRORS OR OMMI'
supervisor must be present for all APPLICANT FROM THE RE
inspections, 24 Hour notice Minimum, COMPLIANCE,
with call back fee. DATE:
TOWN OF YARMOUTH auiLDiNac
MASSACHUSETTS
COVER SHEET
restchester Modular Homes Inc
Offices and Manufa.eturer Plant
®® 30 P.eagans Afill Poad, iFingda.le, AT, 12594
Tel (845)832-9400 Fax (845)832-6698
Manufacturer No. MCI 16
aF-�nor,N maN m e
Expiration Date: 04/30104
ZONING CODE COMPLI-.'
NS DO NOT RELIEVE THE
ISIBILITYOF "AS BUILT'
-, -
MAL -
STATE LABEL LOCATIONS
APP— i_L'.P..I,i=D TO
PORT lo
FACTO=Y 6U't T
1st FLR DRY BOX—
=tea; `s`c %m�y *jM
tM 9Jt
ENTRY CLOSET
c^r •_
1 st FLR WET BOX—
(n
UNDER KITCHEN SINK
D
3 �s
Rr °-
ng,
GrR�
:. ;3,v
to F8c,D.v p�;.�.
•a?- P
• Inspection Agency Label„A
-- Ewe
* Data Plate is under
''” ••... " 'd
kitchen sink on right sid-1
A N
(one per unit)
I A �►,[ N A N Y
REVI SI
N/A
This plan must be on site with TOWN OF
the permit and the Licensed Construction REVIEWED FOR BUILDING
p ANCE. ERRORS OR OMMI'
supervisor must be present for all APPLICANT FROM THE RE
inspections, 24 Hour notice Minimum, COMPLIANCE,
with call back fee. DATE:
TOWN OF YARMOUTH auiLDiNac
MASSACHUSETTS
COVER SHEET
restchester Modular Homes Inc
Offices and Manufa.eturer Plant
®® 30 P.eagans Afill Poad, iFingda.le, AT, 12594
Tel (845)832-9400 Fax (845)832-6698
Manufacturer No. MCI 16
aF-�nor,N maN m e
Expiration Date: 04/30104
ZONING CODE COMPLI-.'
NS DO NOT RELIEVE THE
ISIBILITYOF "AS BUILT'
-, -
MAL -
=NSION (*
JSE WIDTH
00
-0"/30'-0 27'-8'/31'-8"
0
Z
am
<w
o -�-
I- IK
11" 16"
�t- N
JJ
11" 16"
C.9
Q
coui
lL
>>-
11" 12"
of
3 3/4" 8 3/4"
OZ
QU
Q
�
M
v
U
J
rr
�jj
�
LLI
*DELETE SIDING*
Qa
Q
g
�O
Q
c�
Lot
SOFFIT BY
ALL EXT.STAIRS, STEPS, RAILS & GUARDS TO BE
DESIGNED, SUPPLIED AND INSTALLED BY B/P
FRONT ELEVATION
SCALE: 1/4"=l I-oll
-LEVATION I I REAR ELEVATION
SCALE:
YWMH BY
1
_ w
cnN
to
t/7 t
Z QJ 'i N
m E> -co
o Lo
< = m
00 a w i Zco
m [�LP
S rn B
4.25�® o
J w m} �C
rn I
N
F- co
LJ -�Lo
M
U
N� Q��v
� O
o �M�
W Li Q
8 ~O 1 m N
Z ~
—1
z O U
12 WN of ��
z OfN(n
RIGHT ELEVATION U oLLJ
LLLL
n
SCALE: 1/8"=1'-0" o~
cf) Ll
I� d� QI_� �v 9
00
�1--
am
<w
o -�-
I- IK
�t- N
JJ
-i-D TI.
coui
lL
>>-
of
2�
QU
Q
�
M
v
J
�
_ w
cnN
to
t/7 t
Z QJ 'i N
m E> -co
o Lo
< = m
00 a w i Zco
m [�LP
S rn B
4.25�® o
J w m} �C
rn I
N
F- co
LJ -�Lo
M
U
N� Q��v
� O
o �M�
W Li Q
8 ~O 1 m N
Z ~
—1
z O U
12 WN of ��
z OfN(n
RIGHT ELEVATION U oLLJ
LLLL
n
SCALE: 1/8"=1'-0" o~
cf) Ll
I� d� QI_� �v 9
m5f
Ni
Q
ril
CTC2T
A41 T
243
44VEN
'—O"
2432T CN235 HOOD 3-3046
W 3072 - -
T;OCHEN CAR m e7s ns7s
NOOK
SBW
11'-8" x 12'-6"
M sOMTS"T
n
n I 13'-0" x 12'-2 1/2"
'o
o_X
>n
Ll
[2] 1 1/2" x 91 MICRoLAM - 2ND FL [4] 1 1/2" x 9 1/4' MICP.OLAM - 2ND FLL�_comow DECK BY B/P
D30 - - - - e 0.4 0 �0
I
�L)
m GTOP
m
S83"
pCADET
3
PIN RAFTERS CATHEDRAL
"
°' .
AREA
ILIGHT SUPPLIED
CAPELLA
51 .2=DR00M
II
HYDRO TUB
19.79
ING R 0 0 M
°
xoao
V48
W
146
O
17.19
W
C
159
8.0
<V
PD26
C
,
cco
II 0
a�
SE
I
44VEN
'—O"
2432T CN235 HOOD 3-3046
W 3072 - -
T;OCHEN CAR m e7s ns7s
NOOK
SBW
11'-8" x 12'-6"
M sOMTS"T
n
n I 13'-0" x 12'-2 1/2"
'o
o_X
>n
Ll
[2] 1 1/2" x 91 MICRoLAM - 2ND FL [4] 1 1/2" x 9 1/4' MICP.OLAM - 2ND FLL�_comow DECK BY B/P
D30 - - - - e 0.4 0 �0
I
�L)
m GTOP
m
S83"
pCADET
3
PIN RAFTERS CATHEDRAL
"
°' .
AREA
ILIGHT SUPPLIED
[2] 1 1/2" x 9 1/4" MICROLAM
51 .2=DR00M
II
-
19.79
ING R 0 0 M
I 158
xoao
0
DK
146
30.9
17.19
W
C
159
8.0
<V
Q co
cco
II 0
a�
I
LIVING ROOM
�v MSTR BEDROOM
0
i
o
?3'-9" x 11'-6"
17'-11 1/2" x 12'-2 1/2"
a I
l m 1
2-3046
3-3046
12'-7 1/2"
NOTE:
INSTALL BASE TRIM IN CARPET AREAS
S/L BASE TRIM FOR LINO AREAS IN FULL LENGTHS PAINTED
ICHT &
6'-9 1
7'
-4-
z
VENTILATION
SCHEDULE (SF)
R( 0M
AREA
ILIGHT SUPPLIED
VENT SUPPLIED
51 .2=DR00M
219
I 39.5
19.79
ING R 0 0 M
I 158
I 29.2
14.06
DK
146
30.9
17.19
CHEM
159
8.0
7.20
Q co
6'-9 1
7'
-4-
z
Q
z
a.
az
O� 0
I --
°Z SY
L 4L
F-
Luo
~(L
om
oN
00
U
.�
JJ
J �
as
m
Q co
cco
a�
Q
•.
a...... -------
a.
az
°Z SY
m
F-
<C
�0
co 011111 -1110
z .
1
w C.1)--tco
�u�
cni I
ZCD i N
Q >- co
Q m 1!')
a =z�
>r co
D0
zitz: STx
zQ aa
m W a
cp
(n o N
Lu -> ® I
(V�
C/) MCU
Ld c Lr)
U 0 "t
� N o co
N
O M H
0
�' ®®
z _ ®®
z��
Q � �
ooCNQAW
z = N (n
Q o
LLI
mo
LLJ
cf) z aE�" �� U�
44'-0" SHED
2-3046 2432
BEDROOM 2
15'-8" x 12'-6" >
o
I G
M t7
,
CHASE j KD30
24'x24" !
;
[2] 1 1/2" x 14" MISD- ROOF Nn
OF4 P SO T POST
— 6
1fl
-----------
, I I
1 I
------------ I BE40 I
o
0":
SITTING ROOD,, ON
15-3 1/2" x 8'-4"
r�
0
10,—l"
3—
'-0" SHED DORMER
12'-5 1/2"
LOFT
16'-5" x 12'-0"
� Z
N W
� Z
OST [1] 1 1/2' x 14" MICROLAM — ROOF
----------
2'-8"
6'-9 1/2" ,
SUGGESTED 2nd.FLOOR LAYOUT ONLY
All design and construction of 2nd.floor is
the -on site responsobility of the builder and
must be completed in accordance with local
building code and inspection procedures.
State approval of this project only pertains
to the modular units as provided by
Westchester Modular Homes Inc.
IGHT &
VENTILATION
SCHEDULE (SF)
ROOM
AREA
LIGHT SUPPLIED
VENT SUPPLIED
(ROOM 2
196
41.2
22.92
ING ROOIJ
127
30.9
17.19
:
00
J J
cc
I �
I �
----------
14'—
tDc O
�� DECK
fa3 BY B/P
2R
00
wx
w�
N
W
~a
:
00
J J
cc
J�
Qn".
Lt1
�
>r
n
O >r
ft C)
o_
QQ
u_
2R
fail
J
V�Ca
0)
to
C41 i
2i N
E 03
O ^
S m�
�w z Co
00 Q
rQ aax
M 0 I� M a
��o��
o 5 0 D
a� Dorn
(3> �
-}__N
Fa �LL cr>_�CO
WLD r
c^
N �
Cn OO O
LLJ I-) Q
12 �U ®®
~_
z ��
D ZOU
�0 o C/ -)o � o�Q
Z m ofNIn
QLo
5. o
LLJ
LL, Elf in 0
ol� oV
N ��
00
oa:
w�
N
W
~a
:
00
cc
Qn".
a
occ
Mo
fail
J
V�Ca
0)
to
C41 i
2i N
E 03
O ^
S m�
�w z Co
00 Q
rQ aax
M 0 I� M a
��o��
o 5 0 D
a� Dorn
(3> �
-}__N
Fa �LL cr>_�CO
WLD r
c^
N �
Cn OO O
LLJ I-) Q
12 �U ®®
~_
z ��
D ZOU
�0 o C/ -)o � o�Q
Z m ofNIn
QLo
5. o
LLJ
LL, Elf in 0
ol� oV
N ��
CERTIFIED ROOF TRUSS DESIGN
12
- 425 -
CONT RIDGE VENT TYP ROOF
18 SO IN/LF 30YR SELF–SEALING FIBERGLASS SHINGLES
F : OVER 15# ROOFING FELT
OVER 5/8" AGENCY RATED SHEATING
BITUTHANE APPLIED CONTINUOUSLY
12 TO EAVES FOR ICE SHIELD
4.25
2x6 ep,/2 COLLAR E
FASTEN M7TH (6) i6E AT EACH END ON TOP CHORD -
12
TYP INTERIOR WALL / 'q12
[2) 2x4 SPF #3 TOP PLATES
2x4 SPF #3 016" OC STUDS
AIR BAFFLE BY WMH 2x4 SPF #3 SOLE PLATE Ns�k/nONCEBY w oNLr1/2" GWB BOTH SIDES INsv WIAH 1x6 SUB–FASCIA
12" FIBERGLASS BATT /
KRAFT BACK R30 INSULATION , �ALUMN SOFFIT
TYP EXTERIOR WALL 2x10 SPF/2 @,e o.c /
[2] 2x6 SPF #3 IDP PLATES / SOFFIT .75 IN2 /FT VENT
2x6 SPF #3 ® 16" OC STUDS
2x6 SPF #2 SOLE PLATE
N_
1 /2" GWB SIDE 7YP MARRIAGE WALL
[2] 2x3 SPF #3 TOP PLATES
6" FIBERGLASS INSULATION R19 KRAFT BACK 2x3 SPF #3 STUDS ® 16" O.C. 8>J'/16_� q
(MA only –STAPLED TO STUDS (9 7" O.C.) 1 2" AGENCY RATED SHTG. AT MAT -SIDE x °
1/2" AGENCY RATED SHEATHING AT EXT.SIDE / 1/2" GWB INTERIOR SIDEmj _
AIR INFILTRATION BARRIER 2x3 SPF #3 SOLE PLATE e :
VINYL SIDING 3
TTP. SUB–FLOORING / r
3/4" T&G PLYWOOD /� m
2x6 PT SILL PLATE @ 15 OC FLR JST 2x10 SPF #2 g 16" OC FI JST t
—� DBL 2x i 0 SP;_ n 1
(SUPPLIED & INSTALLED BY B/P).
R-19 FIBERGLASS INSULATION
W/ KRAFT BACK VAPOR BARRIER
TO COMPLY W/ENERGY CODE
INSTALLED & SUPPLIED BY B/P
SEE STD. NOTES DVdG #&�,
mi t9
c
Ld
s 745/16
m tl --
'o ` SJPPORTS
E & STAIRS
owd
MICROLAM BEAM.
ROOF PITCH MAY
VARY—>SEE 12
PIN RAFTER ELEV. DWG tt
CROSS SEC110N
SCA' `: 1/4.1•-0. 1 @2�
AIR 13AFFLE ,Q aG ft
BY WMH
ANGLE BRAKET @ EACH
SIDE OF RAFTER/ 1/2• R3DC INSULATION
DIAMETER BOLT 7HRU R W/ VAPOR BARRIER
(2) 4•x 3/8• BOLTS TO TOP PLA
1x8 SUB
FACIA
VINYL SOFFIT
2D IN/SO LF VENT =
�\
\-R-19 FIBERGLASS INSULATION
70 COMPLY W/ENERCY CODE
(INSTALLED BY B/P W/VAPOR
BARRIER TO WARM SIDE)
Q
p O0
F wo
U
d(3
d o r= o�
_ j CC cv
J —
Z cc to
Qa p 0
IF -
a.
o V
-
0
F
OO
nOf
FW_- d
¢ � _ Im e Z
Olt 3 xo
a. IYO N Z
1tl^.
DID
o 0
04)
Z Y
O U
N w
W U
V -4p co
� cm
N
z QJ `0 M
0Of�-c)
3�
K
— = Z �
A ■ _01
co QDO
o�
o <o W -CD
-E / /� o
(n ® U `o ¢ v J < C
J w �r
Q Q>
O
a> =
In QJ �
(n O O M Q
t-
LLJ
0 Ld
Ld O ®®
®®
z
�� D � Q
z O N LO
Qtai �1
CDa
In
Lij
CJ
( -
c�
��h 4
v) a mCD L4
2"D
HYDRO TUB o
LAV
N
SHO
r
WASHER] 1 1/2" y0
DWU DIAGRAM
VIEW `A' - NTS
D = DRAIN
V = VENT
FV = FUTURE VENT
SP = STAND PIPE
DW = DISH WASHER
WC = WATER CLOSET
FC = FIELD CONNECTION BY B/P
B/P = BUILDER/PURCHASER
-4.
C
C'4 WC �
�♦ DW
> 30
Z w KIT SINK
4 V R
oi rFC
!"D
14'
HYDRO
TUB WC LAV
I
I I
FL I I
i I
1
MASTER BATH
._____• DRAIN
BY BP
KIT
BY WMH
>FI WASHER
WC LAV
SINK
DW
I
oa
o
o ��•�
I I
I I
I !
I
I
!
I
I
!
I TYp
I
I
1 I
I
HALF BATH
i
KITCHEN
I
._____• DRAIN
BY BP
�...... DRAIN
BY WMH
VENT
BY BP
VENT
BY WMH
SUPPLY DIAGRAM
VIEW `A' - NTS
FL = FLOOR LINE
= 1/2" SHUT OFF VALVE
COLD
------- HOT
z
V
00
t_ F
W elf
uurr
0+
oa
o
o ��•�
Q
N
co
OO
V
o
OC _
w O
r -r
CL
as
u
oo
-
IL r -
M
O
,cc LL
z
V
ao
t_ F
W elf
uurr
F- M
o *`d„rrru
SES
o ��•�
co
o
OC _
w O
�� Z
CL
u
rr'rrrrr rr•.ta
V
I
M
co
o
0
I
I
O
-
M
O
✓
0
2
Y
S
v
�
'3.
ro
co
Q
cnZ
Q7 y CV
Q
E }-
�—
3
OLo
= z v'
co
a�
¢
¢ r
L7
co
m =Q
®�
z
v X
rnO
O
c La
n
< o
!`ft1
�
V)
n 2 <
71_1
i z °'
Q
L7 co
H
W
�
� o
�
n
r7
®
v o
L0
U)
N
00
O
P113
O
~®®
r
z
Li
UOU
Q-
Ag
zcoo
n
¢ooz`
nava
v
AF
Z
m QfN( n
Q
O
o
LLJ
W
WLL_O�
Ni
�;
L
�
al �'
I
0
ui-X7
------------
44'-D"
BY 6/P A`r200 A
r UNDER CAB ELECTRICAL PANEL
cFl ;" LIGHT PREP LOCATION - BSMT
Room•
ag
1!1 If��>•�o
F
MSTR BEDROOM
pi
Fl
4
LOCATE OUTLET TO FLOODS
S:- TEL
NOOK
FAN
F
6
4 _ — 4 DECK BY B/P
60 AFF 1
rel.
e19 'SLl
LIVING ROOM
I
10 �—
dA I
10
ecc ----
MAR
- -_MAR 1 8 ?--A
I
APPROVAL uWI:TM_ TC
ACTORY BUILT POS'"`
v
41 .
Q.
U)
}Z
Q
DIRECTORY
00
LEGENDCIRCUIT
CIRCUIT
WIRE
AMP
NO.
»
PANEL BOX
NO.
AMP
WIRE
CIRCUIT
KITCHEN COUNT.
12-2
20
2
a�
TIDv DUPLEX REcEPTtcAL
1
4
8-4
RANGE
KIT CTR,KIT,NODK
12-2
20
4
IR
71DV DUPLEX RECEPTCAL - SPLIT WIRED
3
Q m
GL-KIT,NOOK
14-2
15
6
Cc
=
v
22OV RECEPTICAL
5
1 20
I12 -2I
REFRIGERATOR
I
AFI
114-21
15
8
KD
WALL uGHT
7
1 15
114-2I
GL—KIT, MBATH, WIC I GL—MBED, SD
15 110
LL
Z^,
C9LRrG UCHT SURFA".E MOUNTED
I o
1 15
14_
I 2I
GL -ENTRY, HBA -1H
GL -LIVING ROOM
14-21
12
O
R c s� ucNT AT MUNE
11
20
12-2
GAS DRYER
WASHER
12-2
20
14
SNITCH. SIN= POLE
WAY
13
20
12-2
DISHWASHER
BATH GFI'S
12-2
20
16
..r
•+-
SWITM THREE
SW r;FL FOUR WAY
15
20
12-2
HYDRO TUB 6FI
,s
�
FAN/UCHT FIXTURE LTJ RAN.l-,tHDOD FIXTURE
17
I
I
120
��
.',=(,t�
FAN/'JOHi d' HEAT CFIJNG UNIT
19
I
I
I
22
U
�'
S�E�A! >UR�Qi CONNECTION
21
1 I
I
I
I
24
a'
PJNCION BOX
23
I
I I
26
I:M)
A=/DC SMOKE DETECTOR
1 25
I
I
I
26
e
BE..,
127
I i
30
�'
DO}. c BUTTON.
129
I
I I
32
d
TELEPHONE OUTLET
31
I
34
-j=
T=V.SDN CABLE OUTLET
I
C)
THERMOSTAT
33
36
0(0
VACUUM SYSTEM OUTLET
35
38
CEIUNC FAN A UCHT37
40
O
CEIUNC FAN
10
ecc ----
MAR
- -_MAR 1 8 ?--A
I
APPROVAL uWI:TM_ TC
ACTORY BUILT POS'"`
v
41 .
Q.
U)
}Z
Q
tP " W <
ET ,
to
Q G') !
QJ YN
z
¢ r0
_1
�
C = Z Do
C [fj
¢
DO I Q
m Cn
•
i
�� U 0300 <��. 001
N
Q Do
W Lo _
W o
Lo U of
Lo
N 0
�y LC) I."LJ Q>
N
O O O I'll
H Q —�
0
LJ
L) (n
AFA
Q QDJZ
o�Q
LLI
(n
Z
00
Lu O
<
H a
\���S�T1S
bv;'',
a�
bvZ
IR
Q m
'-
w
Cc
=
v
¢
CL
wpIL
a 4L)
LL
tP " W <
ET ,
to
Q G') !
QJ YN
z
¢ r0
_1
�
C = Z Do
C [fj
¢
DO I Q
m Cn
•
i
�� U 0300 <��. 001
N
Q Do
W Lo _
W o
Lo U of
Lo
N 0
�y LC) I."LJ Q>
N
O O O I'll
H Q —�
0
LJ
L) (n
AFA
Q QDJZ
o�Q
LLI
(n
WINDOW SCHEDUL
Z�,:a J--
_
---------
ANULIJSEN
--iic: Iiia-
-..-...-----
01- IILi
5.0
--6-2
5.1
2F346
_ANDERSEN
UC IILT
9.0
1856
ANDERSEN
UC IILi
11.2
�C)�1
ANDERSEN
UC LILT
6.9
Electric service shall be grounded by B/P In compliance with NEC, stale and local
All
ANDERSEN
DC JILT
10.3
305G
ANDERSEN
UC IILT
12.9
4l e
ANDERSEN
UC IILT
11.7
13.
ANDERSEN
DC IILT
14.13
�D446 iFi
ANDERSEN
OC 11LT- DAY
21.7
ltd- 1146 115
ANDERSEN
DC _11LI- PICTURE
25.9
8.
ANDERSEN
CASEMENT
8.0
1. Label locations are designated by:
F-s'll Slate Labels
IA I Third Party Inspection Agency
f-L)-Pl Data Plate
2. Maximum height of egress window sills
is S-6" Above Finished Floor
3. Refer to order selection form for specific
appliances supplied with this house.
4. Bath room fans are rated at 50 CFM.
3.02
3.02
2.94
5.05
5.05
3.85
5.73
5.73
6.41
2.45
6.04
7.40
177/8"x2.41/4"=3.0I SF
1778"x241/4"=3,01 SF
25 7/8" x 16 1/4" = 2.92 SF
29 7/8" x 24 1/4" = 5.03 SF
29 7/8" x 24 1/4" = 5.03 SF
33 7/8" x 16 i/4" = 3.82 SF
33 7/8" x 24 1 /4" = 5.70 Sr
33 7/8" x 24 1/4" = 5.70 SF
37 7/8" x 24 1/4" = 6.38 SF
37 7/8" x 24 1 /4" = 6.38 SF
37 7/8" x 24 1/4" = 6.38 SF
17 7/8" x 24 1/4" = 3.01 SF
10 3/16" it 3S 15 /1 G" - a n cr
FLOOR PLAN NOTES
5. Attic Access(es) on Cape Models are to be
done on site by Builder Purchaser.
6. If applied, any part to be finished by builder
on site, shall be in compliance with all
applicable building code requirements and
under jurisdiction of the local building
inspector. ( garage, additions, porch, etc )
SUPPLY NOTES
1. Materials are type L copper and lead free solder.
2. Water supply shall be securely attached to the buildingg at no
greater distances between support Intervals than specified
Horizontal pipe at 6'-0"
Vertical pipe at each story.
3. Water healer to be supplied and installed by B/P.
4. All supply lines are stubbed through the first floor.
Supply lines below first floor supplied and installed by B/P.
5. All hot water lines in unhealed spoces shall be insulated by B/P.
6. All tubs and/or showers to be supplied will, anti -scald valves
7. All devices installed will self closing valves (i.e. washer,dishwasher)
shall have a water hommer arresling device on the supply line
supplied and installed by B/P on site, in accordance with if
Slate and local applicable codes.
8. All fixture supply lines 1/2" diameter shall have individual
shut off valves. -
7: All interior and exterior Handrails and/or
Guardrails are installed by Builder/Purchaser
DWV NOTES
1. Materials are PVC schedule 40.
2. Drainage and Vent piping shall be securely attached to the building
at no greater support Intervals than specified.
Horizontal pipe at 4'-0" for 02" or larger
Horizontal pipe at 3'-0" for 01 1/2" or smaller
Vertical pipe at 4'-0".
3. All drainage connections horizontal to horizontal and vertical to
horizontal ore long sweep or double 45 fillings.
4. Horizontal vent pipe connections to vertical vent branch or stack
shall occur at least 6" above the floor rim. of the highest fixture
served by the horizontal vent.
EXTERIOR
DOOR .SCHEDULE
DOOR NO
_
DOOR
Sl ZIE
D OR TYPE
1)X26
DX30
OX301
DX302
DX60
PS -6
WE 5-6
2'-8"
3'-O"
3'-O"
3'-O"
2
3'-O"
3'-O"
x
x
X
x
3'-0"
x
x
6'-8"
6'-8"
6'-8"
6'-8"
x 6--8"
6'-9"
6'-7"
INSULATED, METAL, 9 LIGHT
INSULATED, METAL, 6, PANEL
INSULATED,METAL66PANEL+ISLIGHT
INSULATED, METAL, 6PANEL+2SLIGHT
INSULATED,METAL,DOUBLE,lSLIGHT
WOOD, SLIDING GLASS DOOR
WOOD, SLIDING GLASS DOOR
11.
One (1) GFI circuit shall be installed In basement by B/P.
4.
5.
Electric service shall be grounded by B/P In compliance with NEC, stale and local
All
codes.
12.
A clothes washer circuit shall be installed in basement by B/P if washer location is not incorporated
electrical components shall be listed and/or labeled by a nationally recognized
be
testin lab and
into house.
6.
shall installed in accordance with manufacturer instructions and locations/use
Electric
9
instructions.
13.
Receptacles shall not be installed directly over electric baseboard heaters.
7.
In ba
pone) shall be located and mounted In basement by B/P, unless noted otherwise.
A
14.
circuit breakers for electric baseboard heaters are only installed In panels of houses with electric
service disconnect shall be Installed at a readily accessible location nearest the
entrance the
o
P affil f
15.
baseboard systems.
Smoke
8.
of service conductors.
Telephone
detectors are Interconnected and Installed on a lighting circuit with no intervening switches on
9.
and television cable options run to the electric panel location.that
Door bell
circuit.
wires shall be connected in basement by B/P.
16.
17
Smoke detectors shall have a battery back-up power source.
B
FLOOR PLAN NOTES
5. Attic Access(es) on Cape Models are to be
done on site by Builder Purchaser.
6. If applied, any part to be finished by builder
on site, shall be in compliance with all
applicable building code requirements and
under jurisdiction of the local building
inspector. ( garage, additions, porch, etc )
SUPPLY NOTES
1. Materials are type L copper and lead free solder.
2. Water supply shall be securely attached to the buildingg at no
greater distances between support Intervals than specified
Horizontal pipe at 6'-0"
Vertical pipe at each story.
3. Water healer to be supplied and installed by B/P.
4. All supply lines are stubbed through the first floor.
Supply lines below first floor supplied and installed by B/P.
5. All hot water lines in unhealed spoces shall be insulated by B/P.
6. All tubs and/or showers to be supplied will, anti -scald valves
7. All devices installed will self closing valves (i.e. washer,dishwasher)
shall have a water hommer arresling device on the supply line
supplied and installed by B/P on site, in accordance with if
Slate and local applicable codes.
8. All fixture supply lines 1/2" diameter shall have individual
shut off valves. -
7: All interior and exterior Handrails and/or
Guardrails are installed by Builder/Purchaser
DWV NOTES
1. Materials are PVC schedule 40.
2. Drainage and Vent piping shall be securely attached to the building
at no greater support Intervals than specified.
Horizontal pipe at 4'-0" for 02" or larger
Horizontal pipe at 3'-0" for 01 1/2" or smaller
Vertical pipe at 4'-0".
3. All drainage connections horizontal to horizontal and vertical to
horizontal ore long sweep or double 45 fillings.
4. Horizontal vent pipe connections to vertical vent branch or stack
shall occur at least 6" above the floor rim. of the highest fixture
served by the horizontal vent.
EBB - HEATING NOTES
I. Electric baseboard healing circuits are 20 Amp, 220 Volts with 12-2 non-metallic sheathed cable
type NM -B.
2. Maximum wattage per circuit shall be 3750 walls.
3. Baseboards are rated at 250 watts per linear foot.
4. Minimum thermostat range Is 45' to 75' F.
5. General lighting receptacles shall not be located above electric baseboard healing units.
FOUNDATION NOTES
I. The foundation plan is provided for foundation design parameters
onlconditions, applicableete foundation
local andlstateneodes,,dtonbepeviewedsite
and
approved by a registered architect or engineer in the slate of
house designation.
2. The Builder/Purchaser shall be responsible for design, construction
and code compliance of all foundation elements Including (but not
limited lo) structural, plumbing, electrical, heating, energy
conservation and fire separation.
3. Minimum column fooling size shall be 2'-6" x 2'-6" x 10" deep.
4. Concrete strength shall be 300033pPsi or greater.5. PP
G. vandal on sillcolumn ) shlall be preservative l leafed elumber supplied
and installed by B/P prior to house delivery and set). here shall
be no protrusion above top of sill plates.
asemenl smoke detectors are supplied by WMH and Installed by B/P.
FHW - HEATING NOTES
1. Baseboard ratings are based on 190' F water temperature at 1 GPM flow rate with 65' entering air.
2. First floor baseboard units are Installed with heating pipes slubged thru floor. Second floor heating pipes
between baseboard units are Installed in floor and/or wall panels. B/P Is responsible for interconnection
between modules and floors. Balance of heating system Is to be designed, supplied and Installed by B/P.
3. All heating pipes In unheated spaces shall be Insulated by B/P.
4. Minimum thermostat range is 45' to 75' F.
S. Access panels are for the Builder/Purchaser to use In the Interconnection of the healing system. These
panels may be permanently attached and finished over by B/P after heating system is completed
PERIMETER BEAM
(2) 2x10 SPF #2 x
EACH MODULE for or rota wnu v
� z
2x6 SILL PLATEA a o" a:
32
Z 0 O
$ i z v 1
FDTN WALL V)co .r Q
a K
LALLY COLUMN--- �
COLUMN FTG
01/2" BOLT & NUT ra' OF esut sl.Aa
& WASHER 032"OC
+,STEEL PLATE & LAG FDTN FTG
BOLTS BY B/P
LALLY COLUMN
�� RDA INC I.
" � U" PE RA
EDWARD & BARBARA LYMAN ��
Ys -T TYPE:tRO30 �1tE� APPROVAL LIMITED TO
JVO11D A 02563 Qf� Ko= FACTORY BUILT PORTION
154 MATFLOWER TERR.
YARMOUTH, MA
5�ND.A.RD 1��oo>rR�tC ,1 IAN DA1EILL NCSTES` ,,,,,i11, nury,vpF ''4„
ED-ET �L - `,aaURTA�9�:
A.
STEN G'?
1 31
Westchester Modular Homes Inc DATE ; Jpr� kANGPRa`4`�c';
30 Reogons Mill Road, Wingdale, New York, 1259¢ Fss �w
Tel (914)832-9400 Fox (914)832-6698 �-- rorinl
- THOM b' tAJEIC 05-06-03 '''",rn,nnna,,•a,
3
PARTY
APPROVED
PFS CORP
MAR 1 1 2004
APPROVAL LIMITED TO
FACTORY BUILT PORTION
i. ,
I
ELECTRICAL
NOTES
1.
Electrical panel is rated 200 amps.
10.
Door bell button at split entry front doors shall be Installed by B/P
2. Non-metallic sheathed cable Is type NM -e.
3.
Wires ore installed with insulated staples.
11.
One (1) GFI circuit shall be installed In basement by B/P.
4.
5.
Electric service shall be grounded by B/P In compliance with NEC, stale and local
All
codes.
12.
A clothes washer circuit shall be installed in basement by B/P if washer location is not incorporated
electrical components shall be listed and/or labeled by a nationally recognized
be
testin lab and
into house.
6.
shall installed in accordance with manufacturer instructions and locations/use
Electric
9
instructions.
13.
Receptacles shall not be installed directly over electric baseboard heaters.
7.
In ba
pone) shall be located and mounted In basement by B/P, unless noted otherwise.
A
14.
circuit breakers for electric baseboard heaters are only installed In panels of houses with electric
service disconnect shall be Installed at a readily accessible location nearest the
entrance the
o
P affil f
15.
baseboard systems.
Smoke
8.
of service conductors.
Telephone
detectors are Interconnected and Installed on a lighting circuit with no intervening switches on
9.
and television cable options run to the electric panel location.that
Door bell
circuit.
wires shall be connected in basement by B/P.
16.
17
Smoke detectors shall have a battery back-up power source.
B
EBB - HEATING NOTES
I. Electric baseboard healing circuits are 20 Amp, 220 Volts with 12-2 non-metallic sheathed cable
type NM -B.
2. Maximum wattage per circuit shall be 3750 walls.
3. Baseboards are rated at 250 watts per linear foot.
4. Minimum thermostat range Is 45' to 75' F.
5. General lighting receptacles shall not be located above electric baseboard healing units.
FOUNDATION NOTES
I. The foundation plan is provided for foundation design parameters
onlconditions, applicableete foundation
local andlstateneodes,,dtonbepeviewedsite
and
approved by a registered architect or engineer in the slate of
house designation.
2. The Builder/Purchaser shall be responsible for design, construction
and code compliance of all foundation elements Including (but not
limited lo) structural, plumbing, electrical, heating, energy
conservation and fire separation.
3. Minimum column fooling size shall be 2'-6" x 2'-6" x 10" deep.
4. Concrete strength shall be 300033pPsi or greater.5. PP
G. vandal on sillcolumn ) shlall be preservative l leafed elumber supplied
and installed by B/P prior to house delivery and set). here shall
be no protrusion above top of sill plates.
asemenl smoke detectors are supplied by WMH and Installed by B/P.
FHW - HEATING NOTES
1. Baseboard ratings are based on 190' F water temperature at 1 GPM flow rate with 65' entering air.
2. First floor baseboard units are Installed with heating pipes slubged thru floor. Second floor heating pipes
between baseboard units are Installed in floor and/or wall panels. B/P Is responsible for interconnection
between modules and floors. Balance of heating system Is to be designed, supplied and Installed by B/P.
3. All heating pipes In unheated spaces shall be Insulated by B/P.
4. Minimum thermostat range is 45' to 75' F.
S. Access panels are for the Builder/Purchaser to use In the Interconnection of the healing system. These
panels may be permanently attached and finished over by B/P after heating system is completed
PERIMETER BEAM
(2) 2x10 SPF #2 x
EACH MODULE for or rota wnu v
� z
2x6 SILL PLATEA a o" a:
32
Z 0 O
$ i z v 1
FDTN WALL V)co .r Q
a K
LALLY COLUMN--- �
COLUMN FTG
01/2" BOLT & NUT ra' OF esut sl.Aa
& WASHER 032"OC
+,STEEL PLATE & LAG FDTN FTG
BOLTS BY B/P
LALLY COLUMN
�� RDA INC I.
" � U" PE RA
EDWARD & BARBARA LYMAN ��
Ys -T TYPE:tRO30 �1tE� APPROVAL LIMITED TO
JVO11D A 02563 Qf� Ko= FACTORY BUILT PORTION
154 MATFLOWER TERR.
YARMOUTH, MA
5�ND.A.RD 1��oo>rR�tC ,1 IAN DA1EILL NCSTES` ,,,,,i11, nury,vpF ''4„
ED-ET �L - `,aaURTA�9�:
A.
STEN G'?
1 31
Westchester Modular Homes Inc DATE ; Jpr� kANGPRa`4`�c';
30 Reogons Mill Road, Wingdale, New York, 1259¢ Fss �w
Tel (914)832-9400 Fox (914)832-6698 �-- rorinl
- THOM b' tAJEIC 05-06-03 '''",rn,nnna,,•a,
3
PARTY
APPROVED
PFS CORP
MAR 1 1 2004
APPROVAL LIMITED TO
FACTORY BUILT PORTION
i. ,
I