Loading...
HomeMy WebLinkAbout154 Mayflower Terrace - Sewage Disposal Plan_ _�.�.. PROVIDE PRECAST CONCRETE EXTENSION 5 DIA. OUTLET(S) FiNISH GRADE OVER CHAMBERS GENERAL NOTES TOP OF FOUNDATION RISER WITH CONCRETE COVER TO WITHINREMOVABLE COVER �--- 100" ELEV:=�,D:7_ h_ 6" OF FINISH GRADE WHEN NECESSARY. FINISH GRADE OVER D-BOXs "- " 4" PVC FROM O 2" LAYER OF 1/8" r� 0 ®�®® ®®®® ' ` 0 ®®� 00o TO 1/2' DOUBLE FINISH GRADE 0 FND. EL:=_ ___;..r FINISH GRADE OVER TANK EL.= -_ D -BOX O ®®® ®�® ®�®®®0®® O 0p WASHED STONE 1. UNLESS OTHERWISE NOTED. ALL SYSTEM COMPONENTS AND CONSTRUCTION 20" MIN. ACCESS LR ®®®®®®�® METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE TYPICAL FOR 3MAx. O ®®®®®®®®®®�®®�®® ®®® - "'`" ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. J( ) 36"MAX. Oo ®®®®®®�®®®® ®�®®0® ®®® p o 3/4" TO 1 1/2" Co Oo pOp DOUBLE WASHED STONE 2. ANY CHANGES TO THIS `PLAN MUST BE APPROVED BY THE BOARD O 00 OF HEALTH AND THE DESIGN ENGINEER. 4" C.I. OR PROVIDE WATERTIGHT " A - 102 603 " 3` 3" DROP MIN. 3" 9" JOINTS (TYP.) it i 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL SCHEDULE 40 PVC 4" P tN FROM- BE USED IN DISPOSAL SYSTEM UNLESS OTHERWISE NOTED. 1o" 14" P��1 4 PVC OUT TO f PROFILE OF CHAMBERS - TYPICAL FOR CHAMBERS LEACHING FACILITY 1 4. 4" SCHEDULE 40 PVC PERFORATED PVC PIPE SHALL BE USED 12" MIN. INSIDE LEACHING TRENCHES OR 'LEACHING FIELDS. 36" MAX. �----- 62" -� dz1a 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. 48" GAS BAFFLE 6" CRUSHED STONE ® 0 00 6. THIS SYSTEM lS NOT DESIGNED FOR A GARBAGE DISPOSAL. 10' MIN." OVER MECHANICALLY 000 00� 6 CRUSHED STONE COMPACTED BASE 33"®®®®® 0 _�,.��� OVER MECHANICALLY ®®®®� l�.f/ "•u- _ 4. 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED COMPACT D BASE ---- 7 DISTRIBUTION BOX I O PRIOR TO BACKFILLING WHEN SYSTEM IS NEARLY COMPLETE AND TO E INSTALLED ON A LEVEL STABLE 1 ®®®®® 000 READY 'FOR INSPECTION. SYSTEM IS NOT TO BE BACKFILLED BASE. FIRST TWO FEET OF OUTLET iii 00 WITHOUT IRST OBTAINING APPROVAL FROM BOARD OF HEALTH PIPES TO BE LAID LEVEL _I, ' �— ----� f AND DESIGN ENGINEER. SEPTIC TANK NLyt -L-ALLDN_I�- Ch'1A CROSS SECTION VIEW GROUND WATER ELEVATION 1 MIN. 8. .ELEVATIONS BASED OiS- LENGTH — WIDTH — DEPTH — t%71f AI �} 0 fir; �O(N/J�►I�tEp __.._ f i •� TIO BOX /� CROSS SECTIOIN OF� CHAMBERS fk� )4 i�� �� �' 9. `CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO rKtai O : DiS RIBU TION p -V /t DETAI I �Ha BERJ` DE"�"A�L r i'j'LI� (nIAfTFii�COUNT PiI/G DiZ CONSTRUCTION THROUGH DIG -SAFE AND ANY OTHER APPLICABLE SEPTIC TANK PROFILE Ap fFKU4-rooW. NOT TO SCALE ������V, NOT TO'SCALE I�i� IIjam o- IAGENCIES. REPORT ANY DISCREPANCIES TO THE DESIGN ENGINEER. NOT TO SCALE 10. NON -SHRINK GROUT TO BE USED AT ALL POINTS WHERE PIPES ENTER OR � GST PIT DATA LEAVE ALL CONCRETE STRUCTURES IN ORDER TO PROVIDgel E WATER TIGHT SEALS. 1 - - ~� DATE: T. i%P'9 11. ALL TANKS SHALL BE WATERTIGHT TROUGH MANUFACTURERS SPECIFICATIONS INSPECTOR: W` OR APPLICATION OF ASPHALT OR SYNTHETIC POLYMER SEALER. "s SOIL EVALUATOR:'-_ - � 'CERT. : 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS AC U J a: ' TEST PIT : -1` 'TEST PIT ,i: TEST PIT III: LOCATED UNDER PAVEMENT, DRIVES OR TRAVELLED WAYS iN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. e _w +� xv ELEV TOP _ - ELEV TOP = ELEV TOP K AK isoc as �/ z; -.. - 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST" AND ELEV WATER' __ ELEV WATER ELEV WATER FINES. „aK PERC RATE - _. - = = WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND _ MIN/IN PERC RATE MIN/IN PERC RATE MINAN 14. /I -_- �l ,I.—._---^. 'UNSUITABLE MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES DEPTH OF PERC='w %i DEPTH Of PERC= DEPTH OF PERC= OF LEACHING FACILITY. REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, FINES OR OTHER UNSUITABLE MATERIAL IN TEXTURAL CLAS -s- TE'Xfif AL CLASS TEXTURAL CLASS ACCORDANCE WITH 310 CMR 15:255(3). 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN SiTE CONDITIONS FROM THOSE SHOWN PRIOR TO } . PC • I hM 9G1" WkZ44 .-- KOyA Ki O—Iolt eel ►gIC'lWtI,I. f?1K emo luT-fg-ICS CONTINUATION OF WORK. 16. PROPOSED PROJECT IS LOCATED WITHIN: ASSESSORS MAP -- LOT__ ZONING DiSTRICT� BUILDING SETBACKS F: t. S fjqft. R: ft FEMA FLOOD ZONE ELEVATION AS SHOWN ON COMMUNITY PANELlOt%jZI7 17.OWNER OF RECORD: ADDRESS: mu �— 4 a hi�f'I - A1G�tN - - _ r� - - MAIN - DESIGN DATA LEGEND f ROP'D,SED 2'6VERNkN4 0 05T PG q2 NUMBER OF BEDROOMS r ISN SIC 'J� —Too = -- EXISTING CONTOURS �i{APjJl 17:_�G�DIII�L.11Tf`ir�✓f"Z°� NUMBER OF PERSONS no PROPOSED CONTOURS — 1j47r1pCfH-'L11� G GAS LINE DESIGN FLOW Ila GAL/DAY/BEDROOM j� Ir LKljj �lW L r -- Q_L L C _:_1 .ia7�j, "f°IPQ�i117� i EW ELECTRIC/TELEPHONE LINE --D 4+i �t� � ATG -i K ; TOTAL DESIGN FLOW-- GAL/DAY w WATER LINE 4" SOLID RATE ECHE 0 PVC PIPE 1�KOf°Or�:A IOC-'� SEPTIC TANK: — -- �— — — 4" PERFORATED SCHEDULE 40 PVC PIPE --------- LIMITS OF OVERDIG IA 17y1T'Lt1NL{ o �[- -_j' Q GAL X 2007. = k49 GALS. DESIGN CAPACITY -- — LIMITS OF WETLANDS r� iZ USE GALLON SEPTIC TANK. (MIN. SIZE PER REGS) O WELL LOCATION 'C-iN�i ` -� ;j TEST PIT LOCATION 14 SEPTIC TANK — — 41Mop 1q I°KOj �d� LEACHING TRENCH:Ra DISTRIBUTION Box EROSION CONTROL NT \ Kpylt7� ?� 'i'Q Ira'f4II eo SIDEWALL' CAPACITY 2 x (LENGTH + WIDTH) X_/ (DEPTH)= I sQ.FT. - -IS SQ.FT. x 23:Z�E_�+GAL/SQ.FT.- I I GAL. LEACHING/DAY r` J � APR 0 2004 K— 77467 , BOTTOM CAPACITY LENGTH) X IZ T/ (WIDTH)=-SQ.FT. tv,� o r Xi-titsLikKKiN�i FSA _ --' / SQ.FT XGAL/SQ.FT.= GAL LEACHING/DAY ' • - aN 1-�iY TOTALS: -- — - -1 1�IA1 r 'I TOTAL NUMBER CHAMBERS %/ 3 2 $ TOTAL NUMBER OF ;TRENCHES TOTAL LEACHING AREA 471 SQ.FL r �f 0 I' N U E Cs Z _�)tI IN �� �r/r1'l-_ I�AU, j_1✓X�f%IGI�._ AlJr...Pr. 4' j�lr 1�E REV. DATE BY APp'D. DESCRIPTION i�Tifil 7•i�11I6I�-.-. TOTAL LEACHING CAPACITY GAL./DAY l�l�t'�►* � :-..yt A l'A.111� :irgm '11+�h�. /low �I!K . ALS F�A�VE - 4 -- nPPRovEoeBYro ��I SEWAGE DISPOSAL SYSTEM DESIGN r►�� '�'�" , PREPARED FOR III��y�, �Y/�`%'�/. ���jAU-rJ I�Gr��h. �� AfA RESERVED FOR BOARD OF HEALTH USE �/�^ts �'Ps'• 1'%WP�F�D L� MiAr{-J r!/f� (/NII 4HAM 05 -Ko r`F'�' WILLIAM MAE) CIVIL N LOCATED AT �JA7�Rii�yL7-�- q�,�.����q 4- tyA�/�ww.yr� At�MaUTi� .,..� ry=�rrh�tl u7� �_ : �ki, _ NA. T1ZJN�_ �" iy�-- �'UIK�V.,y;�h-- �, "TiXI i�Jril Gi�{iII�IvI� -WILL 65 6'.rGv.1 _-ra I'�i'cI%rye?�. APPROVED BY: Lf/ _�SCALEI'1 QDATE: l ioo ow YPUNl"7Qp�IM'C.i17 rEaUIK C. G rra m Irw roily �w '-OPAW G.A.F. ENGINEERING, INC. �F)�n� ,KIG�f ON HMI fl LIL '� t1✓ I7hl�U-iN '1'0 ' f -114PROFESSIONAL ENGINEERS dc' LAND SURVEYORS 266 MAIN STREET, WAREHAM, MA 02571 SITE PLAN w?Ora 1jG�' ��-I-� �y �+�i� 05 1 t (508)-295-6600 PLAN SCALE: 1" __ " I I i� �J�J � , oRw ev: KKM cmx " W m Me '1r7Mim No.