HomeMy WebLinkAbout154 Mayflower Terrace - New Construction Plans 2MODEL: CAPE, #03353 PROJECT SITE: 154 YAR UTTi' MAR TERRACE BUILDER/PURCHASER: SANDWICH, MA TURNKEY: YARMo TH, MARBARA LYMAN USE GROUP: R4 CONSTRUCTION TYPE: WOOD FRAME(513 AREA: 1144 SQ_ FT. VOLUME: 28,278 C U. F T *Meets MA Code ensu ion 2 5,115 (1&2 Fomily) for construction control BUILDING HEIGHT: 221-7=3/4" NUMBER OF --STORIES: 1 DESIGN OCCUPANCY LOAD: 6 SPECIAL SYSTEMS FIRE ALARM PHOTO ELECTRIC SYSTEM TYPE: SMOKE & CO DETECTORS FIRE SUPPRESSION NA SYSTEM TYPE: OTHER: NA DESIGN LIVE LOADS (PSF) 1NALL: 21 FLOOR: A O R 0 0 F: 4,0 CORRIDORS: I\\IA STAIRS: 100 BALCONIES NA OTHER: NA BUILDING INFORMATION SPECIAL USE PROVISIONS, CONDITIONS OR LIMITATIONS BUILDING MAY NOT BE LOCATED WITHIN FIRE LIMITS 6'-0" MINIMUM CODE REQUIRED SETBACK FROM LOT. LINES WITH 0 HOUR EXTERIOR WALL — B/P SHALL BE .RESPONSIBLE FOR HOUSE LOCATION O LOT .HEATING' SYSTE 0 HEAT IN. TLC HEATING SSYS SHALL BE 'HE OF BUILDER F \A TYPE: D ON SITE BY B/P \A., fU EL: f `J SP,ONSIBILITY URCHASER HEATING SYSTEM CHIMNEY OR VENT TYPE:* SHALL BE THE RESPONSIBILITY OF BUILDER/PURCHASER THIRD PARTY INFORMATION PFS Corp. 2877Ska to gown Road Bloomsburg, PA, 1781 TPIA #27 04/30/04 APPLICABLE BUII )ING_ CODES: —MASSACHUSETTS STATE BUILDING CODE 6th EDITION MASSACHUSETTS FUEL/GAS/PLUMBING CODE —2002 NEC W/MASSACHUSETTS AMENDMENTS —1993 BOCA NATIONAL MECHANICAL CODE W/AMENDMENTS EXTERIOR ENVELOPE THERMAL PERFORMANCE (U VALUESi SEE ATTACHED RESCHECK COMPLIANCE REPORT TABLE OF CONTENTS 1. ELEVATIONS 2. FOUNDATION PLAN 3 FLOOR PLAN 4. CROSS SECTION 5 PLUMBING PLAN-.: 6 ELECTP.ICAL PLAN 8. STANDARD NOTES-* D)=TA(L5 7 TOTAL PAGE i- Catrr�i °aj�=i FIRE DEPT. PHOTO -ELECTRIC TYPE SMOKE DETECTORSARE REQUIRED BY MASS. STATE BLDG. CODE INSIDE AND OUTSIDE OF ALL BEDROOMS WITHIN 20' OF A KITCHEN OR BATH ALL DETECTORS MUST HAVE BATTERY BACK-UP. TOWN OF YARMOUTH REVIEWED FOR BUILDING AND ZONING CODE COM ANCE. ERRORS OR OMMISSIONS DO NOT RELIEVE APPLICANT FROM THE RESPONSIBILITY OF 'AS BUI COMPLIANCE. DATE: � � 7 - �<_ MASSACHUSETTS COVER SHEET Westchester Modular Hones Inc Offices and Manufactz.crer Plant 30 P.eagmns Vill P.oad, iFingda,te, NY, 12594 Tel (845)832-9400 Far (845)832-6698 Manufacturer No. MCI 16 Expiration Date: 04/30104 STATE LABEOCATIONS L L l . „(' �. APPRO`� AL L.°.`.1T=D TO +�.; e ' FACTORYU11. POFMi 1st FLR DRY BOX— 1; ate: ;��r_ " ,� to �y " iR — { 92OD�F ENTRY CLOSET , 1 st FLR WET BOX— ❑Ifl7/,/ . (� UNDER KITCHEN SINK i A,pllilf '` URT A. Sta 7a: R TE -. G mGrnr A7orDvalu = i ltio. 1731 to f Fe•'favi!;;•u 3t,ih ca.,� v � - � KA ti�G ��2,``� * Inspection Agency Lobel_ * Data Plote is under kitchen sink on right side ` A (one per unit) - A N N Y PHOTO -ELECTRIC TYPE SMOKE DETECTORSARE REQUIRED BY MASS. STATE BLDG. CODE INSIDE AND OUTSIDE OF ALL BEDROOMS WITHIN 20' OF A KITCHEN OR BATH ALL DETECTORS MUST HAVE BATTERY BACK-UP. TOWN OF YARMOUTH REVIEWED FOR BUILDING AND ZONING CODE COM ANCE. ERRORS OR OMMISSIONS DO NOT RELIEVE APPLICANT FROM THE RESPONSIBILITY OF 'AS BUI COMPLIANCE. DATE: � � 7 - �<_ MASSACHUSETTS COVER SHEET Westchester Modular Hones Inc Offices and Manufactz.crer Plant 30 P.eagmns Vill P.oad, iFingda,te, NY, 12594 Tel (845)832-9400 Far (845)832-6698 Manufacturer No. MCI 16 Expiration Date: 04/30104 OVERHANG DIMENSION (*) ROOF PITCH O HOUSE WIDTH 24'-0" 26'-0-/30'-0- 27'-8" 31'-8" 5/12 16" 11" 16" 7/12 16' 11" 16" 9/12 12' 11" 12" 12/12 8 3/4' 8 3/4' 8 3/4" PLUMBING VENT STACK *DELETE SIDING* II I LEFT ELEVATION SCALE: 1/8"=1'-0" M v I ALL EXT.STAIRS, STEPS, RAILS & GUARDS TO BE I DESIGNED, SUPPLIED AND INSTALLED BY B/P FRONT ELEVATION SCALE: 1/4"-1 1111111111 d I I I KL I DI E1±1 � REAR ELEVATION I� SCALE: L WIM BY B 12 4.25 r� i z O G G Ur wCL d D O 0 +— CL to Z w� � s g -K 5 _o _ ujo N OSE - �- a N'-• E ¢a J Q �O z q W Qm !1 WIM BY B 12 4.25 r� i CL010 c to �to Col.) i z G YN a >-co m Lo = z 'i co 00 R i m �Q �ox CD m� Wz �rn3 D ~ n C:) Ir uJ !/3 — N 1./ Its M co LJ Lo p pry V' C 'o Co Lr) s v N LJ ® I ' I Ld O O �® O I z �_ UOU 0 -' ffA p ZO- �� � -�- Q p � � Q Z OfNM RIGHT ELEVATION Q n� �. "' w SCALE: 1/8"=1'-0„'— Wh alvl Z :.,,,,,,,,,,,,,,,,,,,, ,` vs < _o _ ujo N OSE �F- J a� Ii W z q W Qm !1 ¢ Q 1 V I 111 W CL010 c to �to Col.) i z G YN a >-co m Lo = z 'i co 00 R i m �Q �ox CD m� Wz �rn3 D ~ n C:) Ir uJ !/3 — N 1./ Its M co LJ Lo p pry V' C 'o Co Lr) s v N LJ ® I ' I Ld O O �® O I z �_ UOU 0 -' ffA p ZO- �� � -�- Q p � � Q Z OfNM RIGHT ELEVATION Q n� �. "' w SCALE: 1/8"=1'-0„'— Wh alvl A I of VIA CTC2T A41T CAPELLA 44'-O" U Z w Z Z 24327 24327 CN235 VOF M _ 3-3046 LuO VA V OS N ~ L CW2430 F 123 3012 - - - d O V "� z J C14CADET O �� BY IP PRWEP els os1S Z du- - >>- 1 i SB36 0 NOa°- o� / IA 11:1010 N 1-- r1 V48 DP 11'-8" x 12'-6" -. - Q - _ QQ m -DELETE SOMTS" D.. KITCHEN to EjF-PD26 13'-0" x 12'-2-1/2" o ct°v N I 1 1 oM a_ a .Z m 00 i aXo a j [2] 1 1/2" x 9 1/4" MICROLAM - 2ND FL [4] 1 1/2' x 9 1/4" MICROLAM - 2ND Rwmw i?N DECK BY B/P WO -� ,Auttlurrry�rhi D30 - - - CL 010. U 20 < `.� z g .-j G3 .�� m GTOP lraD .N �mm Ld a SS3" PIN RAFTERS CATHEDRAL °; Q- wp co Is� CADET [2] 1 1/2" x 9 1/4" MICROLAM ELU 'y���✓ QO���• _ _ II Q 1:11 lit p VLu ¢O O < MSTR BEDROOM DN ` I LINING ROOM I C) I 13'-9" x 11'-6" o 1 T-11 1/2" x 12'-2 1/2" m j ?-3046 L I - z ;..• , 3-3046 1.1 12'-7 1/2" 61-9 1/2" 7'-4" J NOTE: INSTALL SASE Tp iM IN CARPET AREAS S/L BASE TRIM FOR LINO AREAS IN FULL LENGTHS PAINTED LIGHT & VENTILATION SCHEDULE (SF) R 0 0 M AREA LIGHT SUPPLIED I VENT SUPPLIED MST? FEDROOM 219 I 39.5 19.79 LIVING ROOM I 158 29.2 14.06 NOOK 146 30.9 17.19 KITCHEN 159 8.0 7.20 14'-8" J V -_co ' �Q'rn C'AuA to to to _ 1 Z � QJYN m c to Q Z ' 09 < rw � � W- a ax m CD o ? ry o o V)o ma0 C14 LyJ c Lr) 0 M LL- r o� 46 Lc) (3;) N o F- M 0Li �, `�' �® r zOf0 � oQ � o - MAo �Q Z of " v) AW �-q r7 0 V) a� ~� w!V ca cz V) 0 c()= L) I � I 44'-0" SHED DORMER 10 2-3046 2432 O M I N CHASE 24'x24�:, 2' BEDROOM 2 LOFT � a°' so 16'-5" x 12'-0"Lo W Q aU 15'-8" x 12'-6" cn� o �- ¢eQa. DECK O . -- _- ao I. -J.- BY B/P 0 cc wcc d UJQ N �Q pa :� M0 r, � _0 BEDROOM 2 LOFT � a°' so 16'-5" x 12'-0"Lo W Q aU 15'-8" x 12'-6" cn� o �- ¢eQa. DECK O . z jj o 3 BY B/P BEDROOM 196 41.2 22.92 UJ I 30.9 17.19 I D30 .' a�7 z Oo [2] 1 1/2" x 1 4" M -ROOF tno 00' S S� S/L POST [1] 1-1/2' x 14" MICROLAM - ROOF ¢ w O 3F PDST POST - - It 4 o a b :E . JJ..� o S/L —Po5L— d X0 _ -� BF40 I , v r----- Q o _ i N, SITTING ROOM °" 15'-3 1/2" x 8'-4" --------------------- -�I 24'-0" SHED DORMER ` 12'-5 1/2" 6'-9 1/2" 10'-1 " 14'-8" SUGGESTED 2nd.FLOOR LAYOUT ONLY All design and construction of 2nd.floor is the -on site responsability of the builder and must be completed in accordance with local building code and inspection procedures. State approval of this project only pertoins to the modular units as provided by Westchester Modular Homes Inc. LIGHT & VENTILATION SCHEDULE (SF) ROOMP,EA (LIGHT SUPPLIED VENT SUPPLIED BEDROOM 196 41.2 22.92 SITTING RO127 EJEA I 30.9 17.19 I H Q O - 1 Cn z � NYN Erm n =Z d Q CO 00a i m `-� Z* T it a 5 X m 0 I 0 0� opo t� a ®c (%) o ,n vim, a 0 i 0')w J -> - N N Q L QJ y CO LJ c� rn ® N o 00 �S tr) a> v N F- 1 o LLJ_ ��' v A® (>0U �1 �® Q o M o�Q Ar Z m G✓N(n Q i o cn �I � (LLJn �"� zO c� ° n O fY RR ` ^— (SUPPLIED & INSTALLcU by /rJ. R-19 FIBERGLASS INSULATION W/ KRAFT BACK VAPOR BARRIER TO COIAPLY W/ENERGY CODE INSTALLED & SUPPLIED BY B/P SEE STD. NOTES DWG � 19 = i,15/16�/ cD i SUPPORTS STAIRS B/P MICROLAM ROOF PRCH MAY VARY—>SEE SZ PIN RAFTER ELEV. DWG f CROSS SECTION SCALE: 1/4'=1•-0" /. AIR E BY ANCLE BRAIET O EACH ME OF RAFTER W/ 1/2" DIAMETER BOLT THRU (2) a'x 3/6" BOLTS TO TDP PLA 1x6 SUB FACIA VINYL SOMT 20 IN/SO LF VENT R3DC INSULATION W/ VAPOR BARRIER �-R-19 FIBERGLASS INSULATION TO COMPLY W/ENERCY CODE (INSTALLED BY B/P W/VAPOR BARRf-R TO WARM SIDE) LOU Q� I j I I WASHEZ \/ z I > O 1 I , 2'D 1 1/2.V DECK BY B /P l= _ow 0� o U WQ SHO It1 p0 .� a_ Q = BUILDER/PURCHASER �� wCL --- — — i O LAV Z z} YDRO TO S"V 2 �i KIT SINK & DW NO 0� a F- %�y �4 n U �,, i - M 2"D H R 2-Dd 1 1/2-V 2.D 1 1/2'v Q Q �i�frra amnu `t',, LL 0 1/2"V o FRWM DFL n KITCHEN Q� I j I I WASHEZ \/ o `A' — NTS > 0 1 I , 2'D 1 1/2.V DECK BY B /P (V _ow 0� o WR WQ SHO z p0 .� =oJ Q = BUILDER/PURCHASER �� as LAV 20 a F- %�y �4 n U �,, 1 1/2-D 1 1/2"V Q Q �i�frra amnu `t',, LL WC YD "V Q� cy)V I j I I WASHEZ \/ o `A' — NTS > 0 1 I , 2'D 1 1/2.V DECK BY B /P (V _ow �O wo SP = Z DW = SHO z WATER CLOSET � Q B/P = BUILDER/PURCHASER CL cc O s 6, r� z �V LAV a F- %�y �4 n U �,, 1 1/2-D 1 1/2"V Q Q �i�frra amnu `t',, LL WC YD "V cy)V a 1 1/2/2 c► 0 ./ 0cl- 0 LIVING ROOMcyD 0 MSTR BEDROOM 2"D N WASHER 1 HYDRO TUB o LAV \/ o `A' — NTS > 0 V = (V FV = FUTURE VENT SP = Z DW = SHO z WATER CLOSET � o B/P = BUILDER/PURCHASER DWV DIAGRAM VIEW `A' — NTS D = DRAIN V = VENT FV = FUTURE VENT SP = STAND PIPE DW = DISH WASHER WC = WATER CLOSET FIELD CONNECTIONB/P B/P = BUILDER/PURCHASER WC � �♦ DW 30 KIT SINK J rFC "D W a 41- C -0- 0 Q Q)y [V �J �rco M Q_ C> a Do oo < KIT ma Z & v HYDRO SINK DW a p TUB WC LAV SH L WASHER WC LAV 1hv .moi �~ G OHO I a= O 1 I I 1T/y2p' I I 1 I I I I J Q. N�rn y� FL I I I I. I I Ld Q� v r7 IC/)M� MAS rR BATH HALF BATH KITCHEN fr) © � rr _ N _I E�= O m Lo o p r7 r-- LLJ nLLJ � SUPPLY DIAGRAM o VIEW `A' NTS z Of 3-- �® DRAIN BY BP FL = FLOOR LINE C) Q z DRAIN BOf m Q -- Y WMH � ¢ = 1/2" SHUT OFF VALVE z m. Dc " N cn VENT BY BPCOLD Q w J o o VENT BY WMH (n o• ' 0 W�C, - ------ HOT w� `pO Nu a V) a� i � a ul i • •. 9ywpp/P UNDER CAB ELEcTRicAL PANEL LIGHT E. —� ---� W011l 111 -♦ Ilt III TO FLOODS L P� NOOK FAN I r F MSTR BEDROOM 11 LID LID Z CIRCUIT DIRECTORY 00 U Z wo ,,,,,,.,,,. LLJ t=COL-% CIRCUIT WIRE �w NO • •. 9ywpp/P UNDER CAB ELEcTRicAL PANEL LIGHT E. —� ---� W011l 111 -♦ Ilt III TO FLOODS L P� NOOK FAN I r F MSTR BEDROOM 11 LID LID 1Q III LIVING ROOM co 10 p=c MAR 1 8 ?; APPROVAL umffEJ TC'; ACTORY BUILT POP"' Z Z CIRCUIT DIRECTORY 00 LEGEND wo ,,,,,,.,,,. 4 t=COL-% CIRCUIT WIRE AMP NO NO. AMP WIRE CIRCUIT KITCHEN COUNT. 12-2 20 2 o PANEL BOX VDV DUPLEX RECEP11cAL 1 4 8-4 RANGE KIT CTR, KIT,NOOK 12-2 20 4 .ter 11DV DUPLEX RECEPTICAL - SPLIT WIRED 3 j GL-KIT,NOOK 14-2 15. 5 <_ zzDVRE-.ncAL 5 1 20 112-21 REFRIGERATOR I SD AFI WIC 1 GL-MBED, 114-2 15 8 � WALL UCHT 7 15 114-2I GL -KIT, Ivi ATH, GL -LIVING ROOM 14-2 15 1 10 ^ ti- �IJNG UVT SURFACE MOUN-1 1) a 1 15 114-21 GL -ENTRY. HB ATH WASHER 12-2 20 12 p Rr=S:D UGH-. AT "'LING 11 20 12-2 GAS DRYER BATH GFI'S 12-2 20 14 Sv1TCH, SINGLE PO.E 13 20 12-2 DISHWASHER 16 ..r SM1T:H. THRE WAY SWITCH. FOUR WAY 15 20 12-2 HYDRO TUB GFI - 18 FANAUG4T FIXTURE 9 RANGEjHDOO FIXTURE 17 I 20 .—�(,� FAN/JG"T b• ,'!EAT CEIJNG UNIT 19 ( 1 I 1 22 2 1 I 1 24 1 1 ( 1 I 26 JUNCnON BOX 25 1 1 I 28 ; '::TOP. A:/D: SMOKE DcT= TDR 1 30 ^_ ^. 27 1 1 I E DOD.-. BurON 1 29 I 1 1 32 Q i'-.lEPHONE OUTLET 31 I I 34 'IBJ= TELV:SIDN CABLE OUTLET 33 35 ® THERMOSTAT 38 VACUUM SYSTEM OUTLET 35 -CF CEIJNG FAN h LIGHT /� 37 40 n CEILING FAN 8 FLOOO UMTS 39 1Q III LIVING ROOM co 10 p=c MAR 1 8 ?; APPROVAL umffEJ TC'; ACTORY BUILT POP"' Z i 151 I 1 1 1 f i � W W c 'to co co I QJ�N < C Z CO < r GO << 30 Q -a = LD 0 U o30 �/ 3 . � � c L1_ y— o rn U) I J ui r E— _� _ N Q ��U �'�Do }- U LLJ -c _ co � CD � _J " D,co cn L� LLJ C.3 c N � O m 0 0 r"4t_ rn oLLJ _1 F-- I � � Li O L1J Z L) = U ZO- F� Q_ Q CJ z it N (n Q � - (n pV I WLL 0ti IIf Z 00 wo ,,,,,,.,,,. 4 t=COL-% `%�'�SEitS w >>-_ c a 0 w 'a RO 6 N J' Lal U <Qr�+JJ U.. •J,......... i 151 I 1 1 1 f i � W W c 'to co co I QJ�N < C Z CO < r GO << 30 Q -a = LD 0 U o30 �/ 3 . � � c L1_ y— o rn U) I J ui r E— _� _ N Q ��U �'�Do }- U LLJ -c _ co � CD � _J " D,co cn L� LLJ C.3 c N � O m 0 0 r"4t_ rn oLLJ _1 F-- I � � Li O L1J Z L) = U ZO- F� Q_ Q CJ z it N (n Q � - (n pV I WLL 0ti IIf 0 WINDOW 4� EXTERIOR DOOR .SCHEDULE 0 WINDOW SCI SCHEDULE 14p_ w NO. --- iv1f-G'fR -- ANDEIT5EN AIJUCRSLN T'r'I�E UI ITU_ `UC IILT QLASS VENTILATION E6 ESS OPEN-FN G 7 8" x 24 1 4" = 3.01 SF DOORNO. DOOR SI OR TYPE i - _ i' f' Ifi;->t' 2`T, 1 5.0 3.02 OX28 2'-8" x 6'-8" INSULATED, METAL, 9 LIGHT 6.2 __17 3.02 17 7/8" x 21 I/h" = 3.01 SF DX30 3'-0" x 6'-8" INSULATED, METAL, 6 PANEL DC IILT 5.1 2.94 7.5 7/8" x 16 1/4" = 2.92 SF DX301 3'-0" X 6'-8" INSULATED,METAL,6PANEL+ISLIGHT 2846 _ANULRSEN_ ANDERSEN UC IILT 9.0 5.05 29 7/8" x 24 1/4" = 5.03 SF DX302 3'-0" x 6'-8" INSULATED,METAL,6PANEL+2SL.IGHT 2856 ANDERSEN UC IILT 11.2 5.05 29 7/8" x 24 1/4" = 5.03 SF DX50 2 3'-0" x 6'-8" INSULATED,METAL,DOUBLE,l5LIGHT �2 ANDERSEN DC 11LT 6.9 3.85 7/B" x 16 1/4" = 3.82 SF PS-6 3'-O" x 6'-9" WOOD, SLIDING GLASS DOOR 304-6 ANDERSEN DC llLT 10.3 5.73 _33 33 7/B" x 24 1/4" = 5.70 SF WRS--6 3'-O" x 6'-7" WOOD, SLIDING GLASS DOOR ANDERSEN UC IILT 12.9 5.73 " 33 7 8 x 21 1 4= 5.70 SF ANDERSEN UC IILT 11.7 6.41 37 7/8" x 24 1/4" = 6.3B SF 456 ANDERSEN OC IILT 14.6 6.41 37 7 8" x 24 1/4" = 6.38 SF =3h�6-11i_ ANDERSEN DC 111_1_- DAY 21.7 12.45 31 7/8" x 24 1/4" = 6.38 SF - 246 11S t%r`�-3•�- _ANDERSEN ANDL-RSEN UC ilLI 1'ICIURE CASLMENi 25.9 8.0 6.04 7.40 17 7/8" x 24 1/4" = 3,01 _SF 10 3/16" x 35 15/16" 8.0 SF FLOOR PLAN NOTES 1. Label locations are designated by: 7: All interior and exterior Handrails and/or s-L State Labels 5. Attic Access(es) on Cape Models are to be Guardrails are installed by Builder/Purchaser In Third Party Inspection Agency done on site by Builder Purchaser. E Data Plate 2. Maximum height of egress window sills 6. If applied, any part to be finished by builder is 3'-6" Above Finished Floor on site, shall be in compliance with all 3. Refer to order selection form for specific applicable building code requirements and appliances supplied with this house. under jurisdiction of the local building 4. Bath room fans are rated at 50 CFM. inspector. ( garage, additions, porch, etc ) SUPPLY NOTES DWV NOTES 1. Materials are type L copper and lead free solder. 2. Water supply shall be securely attached to the buildingg at no 1. Materials ore PVC schedule 40. greater dlslonces between support Intervals than specilla 2. Drainage and Vent piping shall be securely attached to the building Horizontal pipe at 6'-0" at no greater support intervals than specified. - Vertical pipe at each story. Horizontal pipe at 4'-0" for 02" or larger 3. Water healer to be supplied and installed by B/P. Horizontal pipe at S-0" for 01 1/2" or smaller 4. All supply lines are stubbed through the first floor. Vertical pipe at 4'-0". Supply lines below first floor supplied and installed by B/P. 5. All hal water lines in unhealed spaces shall be insulated by B/P. 3. All drainage connections horizontal to horizontal and vertical to 6. All tubs and/or showers to be supplied with anti-scald valves horizontal ore long sweep or double 45 fittings. - 7. All devices installed with self closing valves (i.e. washer,dishwasher) 4. Horizontal vent reconnections to vertical vent branch or stock shall have a water homrner orrestinal device on the supply line pipe supplied and installed by B/P on site, in accordance with all shall occur at least 6" above the floor rim of the highest fixture Slate and local applicable codes. served by the horizontal vent. 6. All fixture supply lines 1/2" diameter shall have individual shut off valves. ELECTRICAL- NOTES 1. Electrical panel is rated 200 amps. 2. Non-metallic sheathed cable is type NM-B. 3. Wires are installed with insulated staples. 4. Electric service shall be grounded by B/P in compliance with NEC, state and local codes. 5. All electrical components shall be listed and/or labeled by a nationally recognized testing lab and shall be installed in accordance with manufacturer instructions and locations/use instructions. 10. Door bell button at split entry front doors shall be Installed by B/P 11. One [1] GFI circuit shall be Installed In basement by B/P. 12. A clothes washer circuit shall be installed in basement by B/P it washer location is not incorporated into house. 13. Receptacles shall not be Installed directly over electric baseboard healers. 14. circuit breakers for electric baseboard healers are only Installed In panels of houses with electric 6. Electric panel shall be located and mounted In basement by B/P, unless noted otherwise, 7. A service disconnect shall be Installer) of a readily accessible location nearest the point of entrance of the service conductors. 8. Telephone and television cable options run to the electric panel location. 9. Door bell wires shall be connected in basement by B/P. baseboard systems. 15. Smoke detectors are interconnected and installed on a lighting circuit with no Intervening switches on that circuit. 16. Smoke detectors shall have a battery back-up power source. 17. Basement smoke detectors are supplied by WMH and Installed by B/P. FHW - HEATING NOTES EBB - HEATING NOTES 1. Electric baseboard heating circuits are 20 Amp, 220 Volts with 12-2 non-metallic sheathed cable type NM-B. 2. Maximum wattage per circuit shall be 3750 wails. 3. Baseboards are rated at 250 walls per linear foot. 4. Minimum thermostat range Is 45' to 75' F. 5. General lighting receptacles shall not be located above electric baseboard healing units. 1. Baseboard ratings are based on 190' F water temperature of 1 GPM now rate with 65' entering air. 2. First Boor baseboard units are Installed with heating pipes stubged thru floor. Second noor heating pipes between baseboard units are installed In noor and/or wall panels. B/P Is responsible for interconnection between modules and floors. Balance of heating system Is to be designed, supplied and installed by B/P. 3. All healing pipes In unheated spaces shall be Insulated by B/P. 4. Minimum thermostat range is 45' to 75' F. 5. Access panels are for the Builder/Purchaser to use In the interconnection of the healing system. These panels may be permanently attached and finished over by B/P after heating system is completed FOUNDATION NOTES PERIMETER BEAM r [2] 2x10 SPF #2 Tap ar Fa1N wALL V EACH MODULE - "r 2x6 SILL PLATE A V CL -4 O 1 V) V Q FD TN WALL w rz LALLY COLUMN-� r± COLUMN FTG lop or esuT sue 01/2" BOLT & NUT & WASHER ©32"OC STEEL PLATE & LAG FDTN FTG 1. The foundation plan is provided for foundation design parameters only. Complete foundation enylneering based on specific site conditions, applicable tocol and stale codes, to be reviewed and approved by a registered architect or engineer In the stale of house designation. Z. The Builder/Purchaser shall be responsible for design, construction and code compliance of all foundation elements including (but not limited to) structural, plumbing, electrical, healing, energy conservation and fire separation. 3. Minimum column fooling size shall be 2'-6" x 2'-6" x 10" deep. 4. Concrete strength shall be 3000 Psi or greater. 5. Lolly column shall be minimum 03 1/2' sleet pipe. 6. Foundation sill shall be preservative treated lumber (supplied and installed by B/P prior to house delivery and set). There shall be no protrusion above lop of sill plates. ' BOLTS BY B/P LALLY COLUMN 115E GRQIL� Rd- ES11100 RDA INC HOMEOWNER: EDWARD & BARBARA LYMAN (J PE RA THIRD PARTY INSPEC110N AGENCY APPROVAL LIMITED TO 298 ROUTE 130 SANDWICH, MA 02563 NTE' 154 MATFLOWER TERR. YARMOUTH, MA FACTORY BUILT PORTION MITT 1 2004 CONST. DEL WOOD p� J ',,���>>�'urrA, A. r+ ; STEN' 1131G -� f;�\HAN�C�r`Qc~^ APPROVED PFS CORP MAR 1 1 2004 APPROVAL LIMITED TO FACTORY BUILT PORTION QUI-00L LDA E�ACEI- STANDARD NOTES .L l IJ BMS N DATE �- - - -� - SC1il E, -,►....- PAGE• L8J°- V Westchester Modular Homes Inc 30 Rho ons Mill Road, Wln dale, New York, 12594 Tel (914)832-9400 Fax (914)832-6698 -- f .f. DAi o5-oa-t33 - L CHE9 THaM-AS Ei< 0