HomeMy WebLinkAboutEngineered Plan - 2014NOTE: BLDG SEWER'
TO BE RE-ROUTED
FROM REAR OF
DWELL. TO EXIT AT
ELEV. SHOWN
ACCESS COVERS TO WITHIN 6" OF FIN. GRADE
11.7'
SYSTEM PROFILE
(NOT TO SCALE)
PRECAST H-10
RISERS (TYP.)
I 2'0 4"OSCH40 PVC
PIPES LEVEL 1 ST 2'
).45'* 10" 1500 GAL H-10 14"
9 1 TEE SEPTIC TANK TEE $ 9'
GAS BAFFLE:.: °o°o°o°o°o°o
°oo�o�000000
4' LIQ. LEVEL (ACME OR EQUAL) ."
::..:•...... , , . 8.78'
;.;0;0;0;0;0o°o°o°o
°oR °�
WATER-TEST D'BOX
ALL SYSTEM COMPONENTS SHALL BE
NOTES
MARKED WITH MAGNETIC TAPE OR
COMPARABLE MEANS FOR FUTURE LOCATION. 1. DATUM IS NAVD'88
PROVIDE INSPECTION PORTS TO 2. MUNICIPAL WATER IS AVAILABLE
WITHIN 3" OF FINISH GRADE
2% SLOPE REQUIRED OVER SYSTEM ./
FOR LEVELNESS
6" CRUSHED STONE OR MECHANICAL
COMPACTION. (15.221 [21)
(_2_% SLOPE) ( % SLOPE) (1 % SLOPE)
MIN.
FOUNDATION- 15' SEPTIC TANK 12' D' BOX 6' -
*THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL
UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS
PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM
LEGEND-
EGEND99-
--99-
EXISTING CONTOUR
X 99.1
EXIST. SPOT ELEV.
DESIGN FLOW: EXISTING 3 BEDROOM PROPOSED 4
PROPOSED CONTOUR
1993
PROPOSED SPOT EL.
TH1
a5'f
SEPTIC TANK: 440 GPD (2) = 880
TEST HOLE
274�_
SLOPE OF GROUND
o�nPs
UTILITY POLE
4.72 SF/LF x 4' LENGTH = 18.88 SF PER STD.
-FIRE HYDRANT
NOTE: NO ALL SYMBOLS MAY APPEAR IN DRAWING
TEST HOLE LOGS
ENGINEER: DANIEL E. GONSALVES, SE #13587
WITNESS: AMY VON HONE, RS
DATE: 5/28/14
PERC. RATE _ < 2 MIN/INCH
CLASS I SOILS
ELEV. ELEV.
0f$ 49.0' 0„ 4 9.0'
- q A
LS LS
1OYR 3/2
7„ 7., 1OYR 3/2
B B
LS LS
27" 1 OYR 5/8 6 8, 27„ 1 OYR 5/8 6.8'
C
C
PERC MS MS
2.5Y 6/6 2.5Y 6/6
WATER 1,2' WATER 1.2'
126" -1.5' 126" I I -1.5'
GROUNDWATER ENCOUNTERED 94" DOWN
DCE #00-208
EXIST. DWELLING �\
TOP FNDN. = 11.7'
FIRST FL. ELEV. 12.5'
32 QUICK4 UNITS
(NO STONE PROPOSED)
LEACHING
FACILITY
GROUNDWATER ADJ. DATA:
WELL: MIW 29
ZONE: A
ADJUSTMENT: 1.7' (MAY)
NOTE: HOMEOWNER
DESIRES TO RETAIN
TREES (ONE P. PINE
WILL NEED
REMOVING IN AREA
OF SOIL REMOVAL)
5'
ADJUSTED GW EL. 2.9'
Scale: 1"= 20'
0 10 20 30 40 50 FEET
x(7.38
3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT.
4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO
H- 10
5. PIPE JOINTS TO BE MADE WATERTIGHT.
6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH
MASS. ENVIRONMENTAL CODE TITLE V.
7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO
BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE.
8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC.
9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED
WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION
OBTAINED FROM BOARD OF HEALTH.
10 CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING
DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION
OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO LOCUS MAP
COMMENCEMENT OF WORK.
11. EXISTING LEACHING FACILITY SHALL BE PUMPED AND NOT TO SCALE
REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. ASSESSORS MAP 22 PARCEL 34
12. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE LOCUS IS WITHIN FEMA FLOOD ZONE X AS
REMOVED 5' BENEATH AND AROUND THE PROPOSED
LEACHING FACILITY. SHOWN ON COMMUNITY PANEL
#25001 C0569J DATED 7/16/2014
SYSTEM DESIGN:
5' REMOVAL OF UNSUITABLE SOIL REQUIRED
�p UANItL �
A.
Route
GARBAGE DISPOSER IS NOT ALLOWED
�o.
P
DESIGN FLOW: EXISTING 3 BEDROOM PROPOSED 4
c 00
4 BEDROOMS @ 110 GPD = 440 GPD
�z
B
USE A 440 GPD DESIGN FLOW
a5'f
SEPTIC TANK: 440 GPD (2) = 880
Locus
USE A 1500 GAL. SEPTIC TANK
o °fie .�o/ 0e o'�e
o�nPs
4.72 SF/LF x 4' LENGTH = 18.88 SF PER STD.
`\ _
Q
-tit-
0
Lewis
01
Bay
595 SF/18.88 SF/UNIT = 31.5 UNITS
\
Dodo
X�P 51
STANDARD QUICK4 UNITS IN FIELD CONFIGURATION
DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION
OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO LOCUS MAP
COMMENCEMENT OF WORK.
11. EXISTING LEACHING FACILITY SHALL BE PUMPED AND NOT TO SCALE
REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. ASSESSORS MAP 22 PARCEL 34
12. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE LOCUS IS WITHIN FEMA FLOOD ZONE X AS
REMOVED 5' BENEATH AND AROUND THE PROPOSED
LEACHING FACILITY. SHOWN ON COMMUNITY PANEL
#25001 C0569J DATED 7/16/2014
SYSTEM DESIGN:
5' REMOVAL OF UNSUITABLE SOIL REQUIRED
�p UANItL �
A.
AROUND PERIMETER OF LEACHING FACILITY,
DOWN TO SUITABLE SOIL LAYER. REPLACE
GARBAGE DISPOSER IS NOT ALLOWED
WITH CLEAN MED. SAND, TO MEET
SPECIFICATIONS OF 310 CMR 15.255(3)
DESIGN FLOW: EXISTING 3 BEDROOM PROPOSED 4
4 BEDROOMS @ 110 GPD = 440 GPD
USE A 440 GPD DESIGN FLOW
CAUTION: GASLINE IN AREA of
SEPTIC TANK: 440 GPD (2) = 880
76 EXCAVATION
USE A 1500 GAL. SEPTIC TANK
LEACHING:
4.72 SF/LF x 4' LENGTH = 18.88 SF PER STD.
`\ _
-.QUICK _4 UNIT u
-tit-
_
440 GPD/0.`74 GPC /SF = -595 SF LEACHING
C 9.64
REQ'D
;sem 0.2 10k
595 SF/18.88 SF/UNIT = 31.5 UNITS
\
THEREFORE, USE GRAVELLESS SYSTEM OF (32)
X�P 51
STANDARD QUICK4 UNITS IN FIELD CONFIGURATION
ANIEL
SHOWN
10%8
00-208 BRITA.DWG
32 UNITS x 18.88 SF/UNIT = 604 SF > 446 SF
Z. 00
604 SF (0.74 GPD/SF) = 447 GPD (OK)
PROP. SECOND STORY OVER PORTION OF
DWELLING (HATCHED AREA)
- PROP. ADDITIONS
'51zT,/j \A
DATE
APPROVED
MA IDATE BOARD OF HEALTH
TITLE 5 SITE PLAN
OF
19 WEST ROAD
WEST YARMOUTH
PREPARED FOR
SUSAN BRITA
DATE: MAY 28, 2014
off 508-362-4541
fax 508-362-9880
downcope.com
oqC
y�
�p UANItL �
A.
WLS��� V ��
• • •
down cape engineering, idc.
`�,
OJALA
IL N
No. 40980
JAN 3 0 2015
civil engineers
°'cESS\o
land surveyors
E NG\��
ND URIEy
HEALTH DEPT.
939 Main Street ( Rte 6A)
YARMOUTHPORT MA 02675
ANIEL
A. OJALA, P.E., P.L.S.
00-208 BRITA.DWG