Loading...
HomeMy WebLinkAboutEngineered Plans - 2015TOP OF FOUNDATION BROUGHT TO WITHIN 6" OF FINAL GRADE EL. 100._0' EL. 94.0' _ SEPTIC SYSTEM PROFILE (not to scale) IN5P. PORT W I 3" OF GRADE ED EL. 92.4't .5' Flaherty Environmental Services :LEAN SAND P.O. BOX 81 Yarmouth Port, MA 02675 774.994.1 166 VENT IF REQUIRED EL. 89.5'f v -v -v- •a• .w '-06,0-0 SOIL ABSORPTION SYSTEM (2) 500 GALLON CHAMBERS WITH 4' STONE AROUND IN A 12.83'W X 25.0L X 2'D CONFIGURATION BOTTOM OF TEST HOLE EL. 81.5' USGS ADJUSTMENT: N/A GROUNDWATER ELEV:. N/A G M Yarmouth Health Department "PR VED C ame Date � O M SCALE: 1" = 30' PS 207 PG 55 G3zGLEJWMD JUL 2 U ?U15 HEALTH DEPT PAGE 1 OF2 21 ®ISTS�k �aaITAM C REQUIRED: IF SYSTEM IS LOWER C THAN PROPOSED, VERIFY AT TIME C" OF INSTALLATION BY BOH A MIN. ° EL. 86.5' OF 4' BELOW PROPOSED SAS, 4' MIN. 1 EL. 82.5' LOCATION MAP N TH Wh/te Rock Rd. LOCUS Rt. 6 NTS FDA SITE AND SEWAGE PLAN FOR B & B EXCAVATION, INC./ HOLLY HOWLAND 755 WEST YARMOUTH ROAD YARMOUTH PORT, MA DATE.' 711612015 1 REVISED: l� GENERAL NOTES 1. ALL PRECAST COMPONENTS TO BE H-10 RATED. ALL COMPONENTS WITH ANY ANTICIPATED VEHICULAR TRAFFIC TO BE H-20 RATED. 2. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OFA GARBAGE GRINDER. 3. MUNICIPAL WATER IS AVAILABLE. 4. ALL CONSTRUCTION TO CONFORM WITH 310 CMR 15.000 AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS. 5. INSTALLERICONTRACTOR TO REVIEW & VERIFY ALL ELEVATIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO DESIGNER PRIOR TO CONSTRUCTION OR ASSUME ALL RESPONSIBILITY. 6. INSTALLER/ CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SAFE WORK AREA, VERIFYING ALL UTILITIES AND NOTIFYING "DIG SAFE" (1-888-344-7233) 72 HOURS PRIOR TO CONSTRUCTION. Z ANY CHANGES TO OR DEVIATIONS FROM THIS PLAN MUST BE APPROVED IN WRITING BY FLAHERTY ENVIRONMENTAL SERVICES AND LOCAL BOARD OF HEALTH, 8. FINISH COVER OVER COMPONENTS IS NOT TO EXCEED X PER 310 CMR 15.000 UNLESS SHOWN PER PLAN. 9. ALL ABANDONED SEPTIC SYSTEM COMPONENTS TO BE PUMPED DRY AND FILLED WITH CLEAN SAND OR REMOVED AND REPLACED WITH CLEAN SAND. 10.ALL COMPONENTS TO BE PROVIDED WITH WATERTIGHT ACCESS PORTS WITHIN 6" OF FINISH GRADE. 11.ALL SEPTIC TANKS, DISTRIBUTION BOXES AND PIPING TO BE INSTALLED WATERTIGHT. 12, NO KNOWN WETLANDS OR WELLS WITHIN 100 FEET OF PROPOSED LEACHING. 13. THIS IS NOT A CERTIFIED PLOT PLAN AND UNDER NO CIRCUMSTANCES IS THIS PLAN TO BE USED FOR ZONING OR BUILDING PURPOSES, 14. LOT IS SHOWN AS ASSESSOR'S MAP 95 PARCEL 26. 15. LOCUS PROPERTY IS LOCATED WITHIN AN AQUIFER PROTECTION DISTRICT (ZONE II). DESIGN CALCULATIONS NUMBER OFACTUAL BEDROOMS GARBAGE DISPOSAL UNIT TOTAL ESTIMATED FLOW (110 GAUBR1VAYX 3 BR) REQUIRED SEPTIC TANK CAPACITY SIZE OF SEPTIC TANK SOIL CLASSIFICATION DESIGN PERCOLATION RATE 3 NO 330 GAL✓DAY i 660 GAL. 1000 GAL. (EXISTING) I < 2 MIN./INCH EFFLUENT LOADING RATE 0.74 GAL.IDA Y/FT2 LEACHING AREA (2)x(25.0'+12.839(29 = 151 SF 25.0'x 12.83' = 320 SF 471 SFx 0.74 = 348 GPD USE (2) 500 GALLON H-20 CHAMBERS WITH 4' STONE AS DIAGRAMMED INA 25.O'X 12.83'X 2' CONFIGURATION RESERVE LEACHING CAPACITY N/A SOIL EVALUATION TEST HOLE #1 Evaluator. David D. Flaherty Jr, RS, REHS SE#2755 BOH Witness: Amy Vonhone, RS, CHO Date: July 16, 2015 TH-1 ELEV. 91.0' 0"- 22- 22"- 2"22"- 27" 27" - 42" 5, 7 42"-114" G.W. ELEV. N/A BOTTOM TH-1 ELEV. 81.5' FILL A LS 10 YR 3/2 B LS 10YR616 C MCS 2.5Y5/6 PERC FL. 86.3' 24 GALS. <9"AT 327" SYSTEM DETAIL l certify that on November 12, 2002, /have passed the ekaminadon approved by the Department of Environmental Protection and that the above analysis has been performed by me consistant with the required training, expertise, and experience described in 310 CMR 15.018(2)." Flaherty Environmental Services P. 0. Box 89 Yarmouth Port, MA 02675 774.994.1966 I-�— 25' -- -T OF (NTS) SITE AND SEWAGE PLAN FOR B & B EXCAVATION, INC./ HOLLY HOWLAND 755 WEST YARMOUTH ROAD YARMOUTH PORT, MA 1 PAGE2 0F2