Loading...
HomeMy WebLinkAboutEngineered Plan - 2015N ACCESS COVERS MUST BE WITHIN _ INSPECTION 9" MINIMUM. 6" OF FINISH GRADE PDR T 3' MAXIMUM COVER 101.44 FIRST 2` TO F-1BE LEVELS I _lqJ 97.75 o � 97.5 , /j I Ill III I ( J GAS o I / BAFFLE -11 97.67 .9 ' .4 i 3 OUTLET 18 HIGH CAPACITY INFILTRATOR V6 -- D -BOX CHAMBERS IN BED FORMATION 1500GALH-20 SEPT1C TANKCRUSHED STONE OR COMPACTED BASE PROFILE : NOT TO SCALE u.nu nnn. ry nuwuece CLEAN SAND BACKF I L L AROUND AND 2" OVER CHAMBERS _ADJUSTED GROUNDWATER. EL -91.5 _ OBSERVED GROUNDWATER. EL -89.0 1- �roa------------ ���� N gi°0� 45'E T +98.5 Loo AD Ila ' SM. CORNER SLAB I EL -101:02 I 99.7 %Q 1500 GALLON I BEDROOM -SEP TI C TANK T BEDROOM l 0�/� 5_.7_ +98.3 � 9.500+ / BATH OROOM D -BOX .. • d 8E v� BATH 11 O I0 I o \� 1 SUN DINING o I '1' 101 m ROOM LIVING ROOM I � 1 KITCHEN 1 1 \ of M ,� :`• CSSPOOLS K I 1 1� 1 Z PA1 ED DRIVEWAY 1 o� 1 \ GARAGE 1 18 HIGH CAPACITY 1 INFILTRATOR CHAMBERS , 1 TP*1/-__ 1 1 Ido 1 I 99.4 G I ` sSFQ 99.4 99. _ / I \100 00 S 8l 45'W 1 LOCUS MAP 0 /0 20 �vT_. INVERT ELEVATIONS: INVERT AT BUILDING: 98.44 INVERT IN SEPTIC TANK: 98.0 INVERT OUT SEPTIC TANK: 97.75 INVERT IN DIST. BOX: 97.67 INVERT OUT DIST. BOX: 97.5 INVERT IN LEACH CHAMBER: 97.42 BOTTOM OF LEACH CHAMBER: 96.5 ldOJUSTED GROUND WATER: 91.5 OBSERVED GROUND WATER: 89.0 BOTTOM OF TEST HOLE #/ : 89.0 INDEX WELL Ml W 29. ZONE A NOVEMBER 20/4 READING -9.4'. ADJ-2.5' i DESIGN CRITERIA: DESIGN FLOW: 3 BEDROOMS AT 1/0 G.P.D. PER BEDROOM EQUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 200x - 660 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REOUI RED: DESIGN PERC RATE C 5 M1 NII NCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 330 GPD / 0.74 GPDISF - 446 S.F. REOUIRED PROVIDED: 18 HIGH CAPACITY INFILTRATOR CHAMBERS. 112.5 'x 4.73 SFIFT - 532 S.F. 532 S.F. x 0.74 - 393 GPD SOIL TEST PIT DA TA s INDICATES I NO I CA TES PERCOLATION OBSERVED TEST GROUNDWATER 40" -� 126 0 � � 89.0 DATE: NOVEMBER 25. 2014 TEST BY: STEPHEN HAAS WI TNESSED BY: AMY VONHONE PERC RATE: C 2 MI NII NCH 1 1117 El Ell) 1 _ t GENERA L NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULAT I ONS . 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN J' IN DEPTH SHALL BE CAPABLE OF WI TH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE,SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT, D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL "DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING CESSPOOLS TO BE PUMPED DRY. REMOVED AND BACKFILLED WITH SAND. 9. ALL UNSUITABLE MATERIAL (A & B HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. ;o[Y 7E-rRY OF hfSl V�i� � $P tihl,YRNH-ER �• No. 38721 -,)7 SEPTIC SYS TEM DES ION 43 WILSON ROAD . MAP S8. PARCEL 106 SOUTH YARMOUTH. MA . PREPARED FOR: .JOSEPH HE -LEN K VARACE I N ®CB CONCRETE `80UND 81 WOR TH l NGTON AVE-. SHREWSBURY. MA 01.5-4S -W WATER L I NE O HYDRANT SCALE: l s 20* FEBRUARY / 0 . 2015 t! I -G GAS LINE42I �f OHW- OVER HEAD WIRES' STEPHEN A. HAAS �Y! >> t 0- LIGHT POST ;.�y -E- UNDERGROUND ELECTRIC LINE N RINENGIEEGNC ) -T- UNDERGROUND TELEPHONE LINE Y/ \1 P . O . Box 1 6 l G - CTV- UNDERGROUND CABLEV I S I ON LINE ��j, �� T �1 ��� South D e n n i s M A 02660 Y SOB 362-8132 +40.4 SPOT ELEVATION (� � 6 .-__40 ....... EXISTING CONTOUR =9 40 PROPOSED CONTOUR JOB NO: 14-086 40 b TP #/ 0" HORIZON TEXTURE COLOR 99 5. A LOAMY IOYR SAND 4/1 8" -------------------- 98.8 B LOAMY IOYR SAND 314 22" ----------------- 97.7 C / MED I UM IOYR SAND 614 40" -� 126 0 � � 89.0 DATE: NOVEMBER 25. 2014 TEST BY: STEPHEN HAAS WI TNESSED BY: AMY VONHONE PERC RATE: C 2 MI NII NCH 1 1117 El Ell) 1 _ t GENERA L NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULAT I ONS . 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN J' IN DEPTH SHALL BE CAPABLE OF WI TH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE,SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT, D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL "DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING CESSPOOLS TO BE PUMPED DRY. REMOVED AND BACKFILLED WITH SAND. 9. ALL UNSUITABLE MATERIAL (A & B HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. ;o[Y 7E-rRY OF hfSl V�i� � $P tihl,YRNH-ER �• No. 38721 -,)7 SEPTIC SYS TEM DES ION 43 WILSON ROAD . MAP S8. PARCEL 106 SOUTH YARMOUTH. MA . PREPARED FOR: .JOSEPH HE -LEN K VARACE I N ®CB CONCRETE `80UND 81 WOR TH l NGTON AVE-. SHREWSBURY. MA 01.5-4S -W WATER L I NE O HYDRANT SCALE: l s 20* FEBRUARY / 0 . 2015 t! I -G GAS LINE42I �f OHW- OVER HEAD WIRES' STEPHEN A. HAAS �Y! >> t 0- LIGHT POST ;.�y -E- UNDERGROUND ELECTRIC LINE N RINENGIEEGNC ) -T- UNDERGROUND TELEPHONE LINE Y/ \1 P . O . Box 1 6 l G - CTV- UNDERGROUND CABLEV I S I ON LINE ��j, �� T �1 ��� South D e n n i s M A 02660 Y SOB 362-8132 +40.4 SPOT ELEVATION (� � 6 .-__40 ....... EXISTING CONTOUR =9 40 PROPOSED CONTOUR JOB NO: 14-086 40 b