HomeMy WebLinkAbout31 Moss Road Perc Rite and Fast NotesGeneral Construction Notes "Pere -Rite" Drip Dispersal Systems 1. The system shall not be installed In wet or frozen soils. 2. Do not park, drive large equipment, or store materials on the dispersal area. No activity should occur on dispersal area other than the minimum required to install the system. 3. All installation and construction techniques shall conform to state and local codes pertaining to on-site sewage systems and the permit for the site. 4, The installation shall be in accordance with specifications and procedures as supplied by the Manufacturer of the equipment. 5. The contractor shall be certified to install this type of system and should hold a pre -construction meeting with the individuals responsible for the site design and inspections. The meeting should be held prior to the beginning of the site work to ensure protection of the site conditions and to ensure that the system is installed_ according to design. 6. If site conditions are determined to require the installation of the system to deviate from the design plans, all work shall stop Immediately and the DesignerandHealth Agent shall be notified. Any ongoing work shall be the sole responsibility of the contractor. 7. Drip tubing may be installed with a vibratory plow, a static plow, a narrow trencher (<6" width), by hand trenching, or by scarifying the surface and bedding the drip tubing in clean sand meeting the requirements for Hill material in Title 5 at 310 CMR 15.255(3) with cover consisting of sand and topsoil meeting the 6" to 12" depth requirement. The designer may indicate for the tubing to be installed up to 24" below grade. All drip tubing is to be installed parallel with the contour. Vegetative cover must be replaced .for installations where it Is removed or buried during installation. 8. All cutting of rigid PVC pipe, flexible PVC and drip tubing of size 1 1h" or smaller shall be accomplished with pipe cutters approved by Manufacturer.. No sawing of PVC, flexible PVC or drip tubing of size 1 112" or smaller is allowed. All rigid PVC pipe, flexible PVC and drip tubing in the work area shall have the ends covered with duct tape after cutting to prevent construction debris from entering the pipe. Prior to ggluing, all joints shall be inspected for and cleared of any debris. All PVC pipe and fittings In the field shall be SCH 40 All glued joints shall be cleaned and primed with PVC primer prior to being glued. All force mains shall be tested for leaks prior to being backfilled by pressurizing the system and observing for leakage. 9. The Hydraulic Unit is to be placed on a bed of 4"- 6" thick of Y4"- 1'fj" gravel for drainage. If standing groundwater is a problem In the vicinity of the Hydraulic Unit, o screened drain to daylight is - required. Cold Climate Construction Standards "Pere -Rite Drip Dispersal Systems 1. "Top feed" manifolds are to be used to allow for proper manifold drainage. Top feed manifolds are to be located slightly higher than the drip tubing. 2. All attempts should be made to place the Hydraulic Unit with an open southern exposure for warming purposes. 3. The supply and return lines shall be Installed below the frost line. The vertical sections of pipe that connect to the supply and return lines shall be insulated SCH 40 PVC pipe. Insulation shall be minimum 1/2" thick foam (or equivalent). �" Rigid Foam Insulation may be Installed under the Hydraulic Unit to protect the supply and return lines in extreme conditions. Sufficient ground cover around the hydraulic unit 1s required for insulation. All pipes entering and leaving the hydraulic unit shall elbow vertically down 90 degrees to a depth below the frost line prior to extending away from the unit horizontally. Additional insulation inside the hydraulic unit is encouraged. Insulation to consist of blue board, bagged Styrofoam, peanuts or equivalent. If fiberglass Insulation is used it must be sealed to prevent It from becoming saturated. 4. Dense vegetative cover is to be established over the supply trench, return trench and drip tubing prior to the first exposure to freezing temperatures. If vegetation cannot be established, then trenches and tubing are to be covered with a thick layer (minimum 6") of mulch, straw/hay, etc. until such turf cover is established. Established vegetation height over the dispersal area should be a minimum 4'-6" throughout winter months. 5. Contractor shall insulate all "air release valves." Insulation to consist of blue board, bagged Styrofoam peanuts, or equivalent. If fiberglass insulation is used, it must be sealed to prevent it from becoming saturated release valves shall be placed below the ground surface Inside a valve box but at an elevation above the highest drip line in that particular zone. 6. All loops connecting drip runs shall be slightly elevated (minimum 1"- 2") so that they drain into the drip tubing after the pump shuts off. It Is the contractor's responsibility to ensure these loops stay elevated during and after the loops are backfilled. 7. All conduit entering into the control panel shall be sealed to prevent condensation inside the panel. AIR RELEASE VALVE WITH SUPPLY MANIFOLD 112" PIPING TO BE LOCATED ABOVE DRIP TUBING TO ALLOW THE MANIFOLD TO DRAIN AIR RELEASE VALVE STANDARD DRIP SYSTEM DETAILS (TOP FEED MANIFOLD) PRESSURIZED PRESSURIZED DRIP TUBING DRIP TUBING AIR RELEASE VALVE RETURN MANIFOLD TO BE LOCATED ABOVE GRIP TUBING TOA LLON THE MANIFOLD TO DRAIN 4 / _ \ FINISHED GRADE T VERTICAL INSULATED 112" PVC DRIP TUBING 1/2" PVC VERTICAL INSULATED SUPPLY PIPE7 RIGID INSTALLATION DEPTH 172" PVC RIGID RETURN PIPE 1/2" PVC 6"-12" AS FLEX (PER COLD CLIMATE (PER COLD E ) MATE FLEX PER DESIGN NOTES) FORCE MAIN - INSTALLATION DEPTH TO BE BELOW THE FROST LINE MAIN SUPPLY PIPE COMMON BELOW FROST LINE RETURN PIPE BELOW FROST LINE NOTE: THE DRIP TUBING SHALL BE THE LOWEST POINT TO ALLOW FOR DRAINAGE FROM BOTH THE VERTICAL INSULATED SUPPLY AND RETURN PIPES PERC-RITE -15 GPM HYDRAULIC UNIT D-ETAIL Supply Valve Flowmeter Disc Filters Field Flush Valve 9 i 0 a 11/tee Return To Septic Tank (Gravity 0.5% MIN.) r, 1 Common Return Backflush Valve ' 11/" Supply From Pump Tank -1 one Supplies AIR RELEASE VA' TYPICAL PUMP TANK & HYDRAULIC UNIT DETAIL NTS INSTALLATION INSTRUCTIONS,, D=rnE DARY DES,GN Flow Poe THE srrE 1. Measure the distance from the bottom of the tank to 6" down from the top of the riser. (NOTE: IF TH15 VOLUME 15 NOT AVAILABLE Cut the extension pile (by others) to the length necessary to reach this height. Cut 1/2 StiAYIMIZE 5TORAGE VOLUME H TANK BY PLACING THE Of the pipe down 12 t0 18" away from the top Of the pipe for pump discharge pipe. DetaA A ALARM FLOAT A5 CL05E TO THE OUTLET ELEVATION CONTROL UNIT PANEL I A.5 P0551BLE THEN PLACE PEAK ENABLE rLOAT HALF IN AN EXTERNALLY ACI 12" to 18" away from the top of the pipe for pump discharge pipe and attach to riser (see detail A). a;AY BETWEEN THE ALARM AND DRi= ENABLE PLOAT5 LOCATION 2. Glue the extension coupling (by otherto the extension pipe and to the COOT Guide. RIGID FOAM INSULATION HYDRAULIC 3. For re -use of existing concrete pump chambers: glue on the Cool Guide flat cap and place CH 80 UNION UNIT NDPAN BY CONTRA the Cool Guide firmly in the bottom of the tank. Attach the extension to the riser, with FLOAT TREE ATE VALVE CONTRACTOR WEEP the extension to the riser, with the anchors as shown. NOE10 4. For use in new concrete pump chambers: Anchor the flat cap to the bottom of the tank FICTION eox HOLE TO B= In the proper location to hold Cool Guide and extension. The cap may or may not be Hu 11' glued to the device, Attach the extension with the anchors as shown. 5UPPLYUNE FLUSH RETURN To 5. Place the pipe dope on the Cool Guide adapter threads and thread them Into ADAPTER 5ELOw FROST SEPTIC TANK. pump discharge. OR wsuLATEO _ Al- -,r;i,cTU M 6. Attach cooling collar to adapter with set screw provided. COOLING COLLAR ATTACH I. IUNOISTURBE¢ 31NDI6TURBm'/ VERTICAL PIPE \�1�R3� 6, �A-�FERLW�Il�// TO BE INSULATED 8' OF GRAVEL 7. Glue pipe into flow collar and with pump attached, lower Into the guide tube. AS PER I! YDRAUUC \ 15V5% -5k 1 l -lel l S. Attach to discharge pipe, valves, and connect electrical as. specified. 1-1/2" SCH 40 NOTE 1 ! UNIT , 'Pl(K-�!_�I_I( 8' OF STATIC UR TO HU (MAX) COUPLING LARM 1 =1=t\' %-01%0rj?l!!! FLUSH RETURN IXTENSION COLLAR D%2 WATERTIGHT 1-1 �1\' L_ - (BY OTHERS) sEAL ah\ �I=11�! ZONE 1 SUPPLY PVC COUPLING #PEAK EN LL I�\-,% ZONE 2 SUPPLY INS RT (BY OTHERS D/2 ,1= PUMP DISCHARGE TO HU INLETS .: - P ENA E ,y \595115V N0.0. OFF U�1'11� , DRIP ENABLE FLOAT ELEVATION 000 0 0 ° SEE INSER 18' 1=1\=1\'��(1?t� FLOW >�' =R '4M FLOW 0 0 o CH 40 PVC ... 1C 1,SIt COOL GUIDE q-ncllc 51%11=\I� - AND PUMP I =A51h=11gr 2 - ANCHOR BOLT I� 30' MAXIMUM DISTANCE FLIT CAP THROUGH END CAP Cool Guide Patent No. 6,262,689 TYPICAL SYSTEM HYDRAULIC PROFILE NTS nHOUSE ^, HYDRAULIC FLUSH RETURN FROM HU ........... PUMP CHAMBER SEPTIC TANK/ TREATMENT UNIT Y TO HYDRAULIC UNIT COMMON RETURN ZONE 2 Treaded Connection 1/2" SUPPLY COVERS TO with Tape AR RELEASE VALVE WITH�- MANIFOLD GRADE cOVER5 To GRADE }" PERC-P.STE �- ZVItting -Drip Tubing PROPOSED FINlir:ED GRADE=9.S (MIN) - 11.5 (MAX) DRIP TUBING 1J2" RETURN Ram insert Adap PVC FIP Connecting Drip MANIFOLD rOA'FcT SLD„ LINES TO BE PLACED IN NANML FILL APPROX. TITLE 5 SAND HEIGHT OF SAND TO IMPORT I G (APPROX.) TITLESI P 0 PPLY LINE (INSUULATED PER DRIP INVERT SAND FIN.R L3 whkh meets I Fw COLD CU EL=7.0 (MIN) sPe:erMW at I -9LL 310 C IR I5z55 I TO ASSURE PROPER GROUND IXISTING GRADE (MIN.) WATER OFFSET: I REMOVE UNSUETABLE FILL, FILL & A HOR[ZON NE I INSTALL 0 MAIN SUPPLY & TO BE REMOVED (INSULATED PER EL = 7 HIN), THEN INSTALL ((MINSPERSAAL COMMON RETURN COLD CLIMATE NOTES) DRIP DI TUBING LINES LOCATED ESHaey�a.=Z,JS BELOW FROST LINE - - 40 mil HDPE BARRIER DRIP FIELD SAND BED INSTALLATION D AIL Backflush Valve ' 11/" Supply From Pump Tank -1 one Supplies AIR RELEASE VA' TYPICAL PUMP TANK & HYDRAULIC UNIT DETAIL NTS INSTALLATION INSTRUCTIONS,, D=rnE DARY DES,GN Flow Poe THE srrE 1. Measure the distance from the bottom of the tank to 6" down from the top of the riser. (NOTE: IF TH15 VOLUME 15 NOT AVAILABLE Cut the extension pile (by others) to the length necessary to reach this height. Cut 1/2 StiAYIMIZE 5TORAGE VOLUME H TANK BY PLACING THE Of the pipe down 12 t0 18" away from the top Of the pipe for pump discharge pipe. DetaA A ALARM FLOAT A5 CL05E TO THE OUTLET ELEVATION CONTROL UNIT PANEL I A.5 P0551BLE THEN PLACE PEAK ENABLE rLOAT HALF IN AN EXTERNALLY ACI 12" to 18" away from the top of the pipe for pump discharge pipe and attach to riser (see detail A). a;AY BETWEEN THE ALARM AND DRi= ENABLE PLOAT5 LOCATION 2. Glue the extension coupling (by otherto the extension pipe and to the COOT Guide. RIGID FOAM INSULATION HYDRAULIC 3. For re -use of existing concrete pump chambers: glue on the Cool Guide flat cap and place CH 80 UNION UNIT NDPAN BY CONTRA the Cool Guide firmly in the bottom of the tank. Attach the extension to the riser, with FLOAT TREE ATE VALVE CONTRACTOR WEEP the extension to the riser, with the anchors as shown. NOE10 4. For use in new concrete pump chambers: Anchor the flat cap to the bottom of the tank FICTION eox HOLE TO B= In the proper location to hold Cool Guide and extension. The cap may or may not be Hu 11' glued to the device, Attach the extension with the anchors as shown. 5UPPLYUNE FLUSH RETURN To 5. Place the pipe dope on the Cool Guide adapter threads and thread them Into ADAPTER 5ELOw FROST SEPTIC TANK. pump discharge. OR wsuLATEO _ Al- -,r;i,cTU M 6. Attach cooling collar to adapter with set screw provided. COOLING COLLAR ATTACH I. IUNOISTURBE¢ 31NDI6TURBm'/ VERTICAL PIPE \�1�R3� 6, �A-�FERLW�Il�// TO BE INSULATED 8' OF GRAVEL 7. Glue pipe into flow collar and with pump attached, lower Into the guide tube. AS PER I! YDRAUUC \ 15V5% -5k 1 l -lel l S. Attach to discharge pipe, valves, and connect electrical as. specified. 1-1/2" SCH 40 NOTE 1 ! UNIT , 'Pl(K-�!_�I_I( 8' OF STATIC UR TO HU (MAX) COUPLING LARM 1 =1=t\' %-01%0rj?l!!! FLUSH RETURN IXTENSION COLLAR D%2 WATERTIGHT 1-1 �1\' L_ - (BY OTHERS) sEAL ah\ �I=11�! ZONE 1 SUPPLY PVC COUPLING #PEAK EN LL I�\-,% ZONE 2 SUPPLY INS RT (BY OTHERS D/2 ,1= PUMP DISCHARGE TO HU INLETS .: - P ENA E ,y \595115V N0.0. OFF U�1'11� , DRIP ENABLE FLOAT ELEVATION 000 0 0 ° SEE INSER 18' 1=1\=1\'��(1?t� FLOW >�' =R '4M FLOW 0 0 o CH 40 PVC ... 1C 1,SIt COOL GUIDE q-ncllc 51%11=\I� - AND PUMP I =A51h=11gr 2 - ANCHOR BOLT I� 30' MAXIMUM DISTANCE FLIT CAP THROUGH END CAP Cool Guide Patent No. 6,262,689 TYPICAL SYSTEM HYDRAULIC PROFILE NTS nHOUSE ^, HYDRAULIC FLUSH RETURN FROM HU ........... PUMP CHAMBER SEPTIC TANK/ TREATMENT UNIT Y TO HYDRAULIC UNIT COMMON RETURN ZONE 2 Treaded Connection PVC Primed and Glued with Tape LTTee-floonn ��,p ZVItting -Drip Tubing Flexarbed Ram insert Adap PVC FIP Connecting Drip Fitting Tubing to Flexible PVC Pipe Ma iiiofd �/ Return CI Return rUUp ly /2" Field Manifold (TYP� 1/2" Supply Return TYPICAL MANIFOLD CONNECTIOi4 WA NOTE; ALL RIGID AND FLEXIBLE PVC ARE TO BE LpCATED ABOVE THE DRIP LINE TO ALLOW " FOR THE PIPES TO DRAIN PVC RP ADAPTER j- -'l 1/2" FILEI (TR.) I PVC 4' TYP. DRIP DRIP LOOP TUBING NOTE, ALL DRIP LOOPS ARE TO BE LOCATED 2" ABOVE THE DRIP LINE TO ALLOW FOR THE LOOPS TO DRAIN NOTE: 1. THE AIR RELEASE VALVES 2. EACH ZONE TO HAVE SHALL BE PLACED AT THE TWO AIR RELEASE VALVES, HIGHEST POINT ON THE RETURN LINES TO BE SUPPLY AND RETURN LINE CONNECTED A COMMON FOR EACH ZONE RETURN UNE. VALVE 5 "TH& MM. RIGID FOAM ®IN51JTATION IN5ERTED UNMR6 ER L FROM orsP RELhR R SE VALVE CHEa( VALVE AST Lt IT a'L ZONE 1 �> COMMONTo FIRST LATERAL RETURN L CONN 2ON AIR RELEASE & CHECK VALVE DETAIL fA5T 5Y5TEM NOTES: 1. GENERAL The contractor shall furnish and Install ( I ) MlcroFAST 0.5 treatment system as manufactured by Bio -Microbes, Inc. The treatment system shall be complete with all needed equipment as shown on the drawings and specified herein. The principal Items of equipment shall Include FA51-5y5tem Insert, Insert lid (or leg extensions If that option is chosen), blower assembly; blower controls and alarms. The MlcroFAST 0.5 unit shall be situated within a 450 gallon minimum compartment In a two compartment tank as shown on the plans, or In a 800 gallon one- compartment necompartment tank. Tanks) must conform to local, state, and all other applicable codes. The contractor shall provide coordination between the FAST system and tank supplier with regard to fabrication of the tank, Installation of the PA5T unit and delivery to the fob site. 2. OPERATING CONDITIONS The MlcroFAST 0.5 treatment system shall be capable of treating the wastewater produced by typical family activltles (b;ath, laundry, kitchen, etc.) ranging from ( I ) one to (8) eight persons and not to exceed 500 U5 Gallons per day (1893 LPD). 3. MEDIA The FAST media shall be manufactured of rigid PVC, polyethylene or polypropylene and It shall be supported by the polyethylene Insert. The media shall be fixed In position and contain no moving or wearing parts and shall not corrode. The media shall be deslgned and installed to ensure that sloughed solids Immediately descend through the: media to the bottom of the septic tank. 4. BLOWER', The MlcroF,A5T 0.5 unit shall come equipped with a regenerative type blower capable of delivering 1 1-25 CFM. The blower assembly shall Include an Inlet filter with metal filter element. BLOWER HOUSING SHALL BE INSULATED WITH SOUND DEADING MATERIAL. 5. REMOTE: MOUNTED BLOWER The blower may be mounted remote with no more than 100 ft (30.5 M) of piping and no more than four elbows, from the MlcroFAST unit on a contractor supplied concrete base. The blower mint not set In standing water and Its elevation must be higher than the normal flood level. A two-piece, rectangular housing shall be provided with tamper -proof screws. The dlscharge air line- from the blower to the MlcroFAST shall be provided and Installed by the 7. ALARMS The alarm system shall consist of a visual and audlble- alarm to Indicate loss of power to the blower andlor high water level. A manual silence switch is Included. 8. INSTALLATION AND OPERATING INSTRUCTIONS All work must be done In accordance with local codes and regulations. Installation of the MlcroFAST 0.5 shall be done In accordance with the written instructions provided by the manufacturer. No more than four foot of fill may be placed over the FAST 0 lid. Operation manuals shall be furnished which will Include a description of Installation, operation, and system maintenance procedures. There shall be a separate manual for the Installer, service provider, and owner, tailored to each. Si. WARRANTY The manufacturer of the MlcroFAST 0.5 treatment system shall warrant for three years from the date of shipment or two years form the date of start-up, whichever occurs first, that the equipment they provide will be free from defects In material and workmanship. In the event a mechanical component falls to perform as specified or Is proven defective In service during the warranty period, the manufacturer shall repair or replace such defective parts. (Cost of labor on repair/replacement is not covered under this warranty.) The replacement or repair of those Items normally consumed In service such as air filter, etc., shall be considered as part of routine maintenance and upkeep. It is not intended that the manufacturer assume responsibility for contingent Ilabliltles or consecluentlal damages of any nature resulting from defects in design, material or workmanship, or delays in delivery, replacement, or otherwise. 10. FLOW AND DOSING Wastewater treatment systems work best when influent flow Is delivered as conslstently as possible. FAST systems have been successfully designed, tested and certified receiving gravlty. demand -based Influent flow. However when Influent flow Is controlled (either by pump or other means) to the FAST system to help with highly variable flow conditions, then multiple feeding events should be used to help assure even flow, optimum performance, and reliability. 10. BLOWER AND VENT Owner shall confirm locations of blower and vent. JOHAl M. O'REILLY CIVIL NO. 35200 contractor. G. ELECTRI CAL PAGE AGE 2 Of 2 The electrical source should be within 150 feet of the blower. Consult local code for longe- wiring distances. All wiring must conform to code. The Input b5clottl Residence power required for the blower Is 1 15/230 Volts, c/o Gregg Ll5ciottl, 83 Orchard HILI Park Drive, Leominster, MA OI 453 5ingle Phase, GO/50 Hertz, 3.8/1 .9 Full Load Amps, FERC RITE t- FAST NOTES minimum wire size Is I G A.W.G. (Locked eotor Amps 31 Moss Road, West Yarmouth, MA are 18.G/9.3). All conduit and wiring between the electrical control panel (optional), the power supply, J.M. O'REILLY SC ASSOCIATES, INC. and the blower shall be furnished and In=,talled by the Professional Engineering &Lana surveying services 0 contractor. 1573 Main Street -Route BA P.O. Boz 1773 (508)896-6601 Office Brevrster, MA 02631 .(508)896-8802 Fax DATE: SCALE: DY: CHECK: I JOB NUMBER: GAAAJot sIL,5oott, Develovment\Mo55Road 127GA\c(wg\I 27GA.5D5.revG-30- I O.dwg 04/21/10 - As Noted MTF/f JMO JMO- 127GA