Loading...
HomeMy WebLinkAbout31 Moss Road Site & Sewage Disposal SystemGENERAL NOTES: A.) NEITHER DRIVEWAYS NOR PARKING AREAS ARE ALLOWED OVER SEPTIC SYSTEM UNLE55 H-20 COMPONENTS ARE USED. B.) THE DESIGNER WILL NOT BE PESPON51BLF FOR THE SYSTEM AS DESIGNED UN - j LE55 CONSTRUCTED AS SHOWN. ANY CHANGES SHALL BE APPROVED IN WRITING. C.) CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. CONSTRUCTION NOTES: 1.) ALL CONSTRUCTION SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5, AND THE REQUIREMENTS OF THE LOCAL BOARD OF HEALTH. 2.) SEPTIC TANK(5), GREASE TRAP(5), DOSING CHAMBER(5) AND DISTRIBUTION BOX(E5) SHALL BE SET ON A LEVEL STABLE BASE WHICH HAS BEEN MECHANICALLY COMPACTED, OR ON A G INCH CRUSHED STONE BA5E. 3.) SEPTIC TANKS) SHALL MEET A5TM STANDARD C 1 127-93 AND SHALL HAVE AT LEAST THREE 20" DIAMETER MANHOLES. THE MINIMUM DEPTH FROM THE BOT- TOM OF THE SEPTIC TANK TO THE FLOW LINE SHALL BE 48". 4.) SCHEDULE 40 PVC INLET AND OUTLET TEF5 SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE OF THE 5EFTIC TANK AND SHALL BE INSTALLED ON THE CENTERLINE OF THE TANK DIRECTLY UNDER THE CLEANOUT MANHOLE. 5.) PAI5E COVERS OF THE SEPTIC TANK AND DISTRIBUTION BOX WITH PRECAST CONCRETE WATER TIGHT RISERS OVER INLET AND OUTLET TEES TO WITHIN G" OF FIN 15H GRADE, OR AS APPROVED BY THE LOCAL BOARD OF HEALTH AGENT. 6.) PIPING SHALL CON515T OF 4" SCHEDULE 40 PVC OR EQUIVALENT. PIPE SHALL BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LESS THAN I %. 7.) DISTRIBUTION LINES FOR 501L AB50PPTION SYSTEM (AS REQUIRED) SHALL BE 4" DIAMETER SCHEDULE 40 FVC LAID AT 0.005 FTJFT. LINE SHALL BE CAPPED AT END OR AS NOTED. 8.) OUTLET PIPES FROM DISTRIBUTION BOX SHALL REMAIN LEVEL FOR AT LEAST 2' BEFORE PITCHING TO 501L ABSORPTION SYSTEM. WATER TEST DISTRIBUTION BOX TO ASSURE EVEN DISTRIBUTION. 9.) DISTRIBUTION BOX SHALL HAVE A MINIMUM SUMP OF G" MEASURED BELOW THE OUTLET INVERT. 10.) BASE AGGREGATE FOR THE LEACHING FACILITY SHALL CON515T OF 314" TO 1- 112" DOUBLE WASHED STONE FREE OF (RON, FINES AND DUST AND SHALL BE INSTALLED BELOW THE CROWN OF THE DISTRIBUTION LINE TO THE BOTTOM OF THE SOIL ABSORPTION SYSTEM. BASE AGGREGATE SHALL BE COVERED WITH A 2" LAYER OF I /8" TO 1/2" DOUBLE WASHED STONE FREE OF IRON, FINES AND DUST. 1 1.) VENT SOIL ABSORPTION SYSTEM WHEN DISTRIBUTION LINES EXCEED 50 FEET; WHEN LOCATED EITHER IN WHOLE OR IN PART UNDER DRIVEWAYS, PARKING AREAS, TURNING AREAS OR OTHER IMPERVIOUS MATERIAL; OR WHEN PRESSURE DOSED. 12.) SOIL ABSORPTION SYSTEM SHALL BE COVERED WITH A MINIMUM OF 9' OF CLEAN MEDIUM SAND (EXCLUDING TOP501U. 13.) FINISH GRADE SHALL BE A MAXIMUM OF 36" OVER THE TOP OF ALL SYSTEM COMPONENTS, INCLUDING THE SEPTIC TANK, DISTRIBUTION BOX, DOSING CHAMBER AND 501L ABSORPTION SYSTEM. SEPTIC TANK5 SHALL HAVE A MINIMUM COVER OF 9". 14.) FROM THE DATE OF INSTALLATION OF THE SOIL ABSORPTION SYSTEM UNTIL RECEIPT OF A CERTIFICATE OF COMPLIANCE, THE PERIMETER OF THE SOIL ABSORP- TION SYSTEM SHALL BE STAKED AND FLAGGED TO PREVENT THE USE OF SUCH AREA FOR ALL ACTIVITIES THAT MIGHT DAMAGE THE SYSTEM. 15.) THE BOARD OF HEALTH SHALL REQUIRE INSPECTION OF ALL CONSTRUCTION BY AN AGENT OF THE BOARD OF HEALTH (OR THE DESIGNER IF TH15 SYSTEM RE- QUIRES A VARIANCE) AND MAY REQUIRE SUCH PERSON TO CERTIFY IN WRITING THAT ALL WORK HAS BEEN COMPLETED IN ACCORDANCE WITH THE TERMS OF THE PERMIT AND APPROVED PLANS. 48 HOURS ADVANCE NOTICE 15 REQUESTED. I G.) ALL TOPSOIL 4 SUBSOIL (A 4 B) ENCOUNTERED WITHIN 5' AROUND THE 5.A.5. SHALL BE REMOVED DOWN TO THE CLEAN SAND AND REPLACED WITH CLEAN SAND, COMPACTED TO MINIMIZE SETTLEMENT. 17.) ALL FILL USED ON PROJECT SHALL BE CLEAN AND FREE OF DEBRIS. FILL SHALL BE PLACED IN G-8" UrT5 AND BE COMPACTED TO 95% OF MAXIMUM DRY DENSITY AS PER AA5HO T 180, METHOD D. FILL TO BE USED SHALL CONFORM TO 31 O CMR 15.255 (3). CONSERVATION NOTES: 1.) LIMIT OF WORK SHALL BE AS SHOWN ON PLAN VIEW. THE LIMIT OF WORK SHALL CONSIST OF DOUBLE STAKED HAYBALE5 OR SILT BARRIER AS CONDITIONED BY CON5tRVATION COMMISSION AND SHALL BE CON5TRUCTED PRIOR TO ANY WORK ON THE PROJECT. 2.) ROOF RUN-OFF SHALL BE CONTROLLED THROUGH GUTTER, DOWNSPOUTS, 4 DRY -WELLS OR BY STONE TRENCHES (2'x I') LOCATED UNDER ALL DRIP LINES. 3.) ALL DISTURBED AREAS SHALL BE REVEGETATED UPON THE COMPLETION OF THE PROJECT. 4.) ALL FILL REQUIRED FOR THE PROJECT SHALL BE CLEAN SAND, FREE OF DEBRIS AND GARBAGE. UN -USED MATERIAL SHALL BE REMOVED FROM PROPERTY. FINISH WITH BLACK BARK MULCH , ° < O e prGek4i . O 13EARBEPPY 2 GAL. MIN SHORE JUNIPER 2 GAL MIN n1 (� 3} • PLANTING DETAIL: SCALE I "=20' FLOW PROFI LE: NOT TO SCALE 24" DIAMETER CONCRETE COVERS RAISED TO WITHIN G" OF FINISH FINISH FLOOR GRADE (OR A5 NOTED) EL= I G.O± (SEE NOTE #5) Prono5ed EL= 1 1.5± 7 I O" iii 410" 14" T GAS BAFFLE - 1 500 GALLON SEPTIC TANK SOIL TEST LOGS: TEST PIT 1: EL=5.3± DEPTH FROM SURFACE (INCHES) SOIL HORIZON SOIL TEXTURE (USDA) SOIL COLOR (MUN5EW SOIL MOTTLING OTHER 0-10 A Loamy Fine Sand I OYR 313 NONE NONE 10-24 B Loamy Fine Sand I OYR 8 NONE Fine Sand 24-84 CI Loamy Sand I OYR 7/5 NONE Perc 24' Groundwater R EL=49" C2 Fine Sand I OYP 612 NONE Groundwater 0 EL=40" TEST PIT 2: EL=6.2± DEPTH FROM SOIL SURFACE HORIZON (INCHES) SOIL TEXTURE (USDA) SOIL COLOR (MUN5EW SOIL OTHER MOTTLING O- Loam Fine Sand I OYR 3/3 NONE 7-26 B Loam Fine Sand I OYR 5/8 NONE 2G-81 I Fine San I OYR 6/4 NONE Perc 58" CI Fine Sand I OYR G14 Groundwater EL=58" TFST PIT 3: EI_=58± DEPTH FROM SURFACE (INCHES) 501L HORIZON 50L T URE (U DA) 501L COLOR (MUN5EW SOIL OTHER MOTTLING 0-9 A LoAmy Fine Sand I OYR 313 NONE 9-2G B Loamy Fine Sand I OYR 5/8 NONE 2G-82 CI Fine Sand I OYR G14 NONE Medium Loamy Sand I OYR GIG NONE Loose Weepmq H2O R 42" Groundwater R EL=49" TEST PIT 4: EL=5.3± DEPTH FROM SURFACE (INCHES) 501L HORIZON SOIL TEXTURE (USDA) SOIL COLOR (MON- EW SOIL OTHER MOTTIJNG 0-8 A Loam Fine Sand I OYR 313 NONE 8-2 B Loam Fine Sand I OYK 5/8 NONE 25-83 C I Loamy Sand I OYR 7/8 NONE Medium Loamy Sand I OYR GIG NONE Loose Weepmq H2O R 42" Groundwater P EL -44" DATE OF TESTING: 04122/10 PERCOLATION RATE: LE55 THAN 2 MINANCH IN "C" LAYERS. WITNESSED BY: KEITH E. FERNANDES, FIT, J.M. OREILLY C ASSOCIATES, INC. AMY VON HONE, AGENT, YARMOUTH HEALTH DEPARTMENT STANDING GROUNDWATER ENCOUNTERED AS NOTED USE A LOADING RATE OF 0.74 GPD/5F FOR SIZING OF SOIL ABSORPTION SYSTEM. I 1 DRIP LINE 1 1 1 2" OF I/8"-1/2" STONE 1 T 2' 3/4"- 1 112" STONE WRAPPED �I IN FILTER FABRIC NOTE: STONE TRENCH SHALL BE CENTERED UNDER ALL DRIP EDGE5 AND ALONG THE EDGE OF THE STONE POOL DECK. TYPICAL STONE DRIP LINE TRENCH DETAIL: NOT TO SCALE SOIL TEST LOGS: HAND BORING I: EL -5.1± DEPTH FROM SURFACE (INCHES) 501L HORIZON SOIL TEXTURE (USDA) 501L COLOR (MUN5EW SOIL MOTTLING OTHER 0-11 A Fine Sand I OYP 1 NONE Loose 11-17 B Fine Loamy Sand I OYR 414 NONE Friable 17-83 CI Medium Loamy Sand I OYR GIG NONE Loose Weepmq H2O R 42" 83-108 C2 Fine Sand I OYP 612 NONE Verj Friable N ui J w J w HAND BORING 2: EL=4.9± DEPTH FROM SURFACE (INCHES) 501L HORIZON 501L TEXTURE (USDA) 501L COLOR (MUN5EW SOIL MOTTLING OTHER 0-7 A Fine Sand I OYR 5/1 NONE Loose 7-19 B Fine Loamy Sand I OYR 4J4 NONE Friable 19-52 CI Medmm Loamy Sand IOYR 6J6 NONE Loose Wee m H20ED 0" 52-109 C2 Fine Sand I OYR G)2 NONE Very Friable N ui J w J w DATE OF TESTING: 09/04/96 PERCOLATION RATE: LE55 THAN 2 MIN/INCH IN "C' LAYERS. WITNESSED BY: MATTHEW T. FARREL, EIT, J.M. O'REILLY 4 ASSOCIATES, INC. AMY VON HONE, AGENT, YARMOUTH HEALTH DEPARTMENT NO WATER ENCOUNTERED USE A LOADING RATE OF 0.74 GPD/5F FOR SIZING OF 501L ABSORPTION SYSTEM. BUILDING COVERAGE: DWELLING 1,577.2 SF WOOD DECK 607.7 SF POOL 738.8 5F POOL DECK 607.4 51' POOL TROUGH 81.8 5F ENTRY 193.2 5F SHOWER 40.0 5F WALI5 70.0 5F TOTAL 4, 189. 1 5F r ----Utility Pole #4 4, 189.1 X86 18.731 x100=22.4% PETER F. 5ARTHOU 4 - EL=5.55 MIMI I. 5ARTHOU CALCU .ATI ONrJ : LAND COURT DOCUMENT #1 15351 PARCEL IIG INFILTRATION RATE: 0.9 GAL/5F/MIN (SAND) BACKWASH BED: 32'x 12'x 18" 22' SURFACE AREA: [2(I 2 x 1.5) + 2(32 x 1.5) + (32 x 1.5))=516 5F \ INFILTRATION CAPACITY: 516 5F x (0.9 GAL/SF/MIN) (I 8" Effedve %� Depth) =464 GAUMIN BACKWASH FILTER TO BE LIMITED TO 100 GAUMIN VOLUME: 32 x 12 x 1 .5=576 CF -EL=3.75 57G x 45%=259 CF - 1930 GAL. EL=2.75 (GROUND WATER) NOTE: CONSTRUCT BY PLACING THREE (3) - 8' x 4' FLOW DIFFUSERS NSE FD 4'x 8'- D FLOW DIFFUSER UNITS BY 5HOREY PRECAST, INC.) WITH 4' OF STONE AROUND AND G" OF STONE BELOW BACKWASH BED DETAIL: NOT TO SCALE INSPECTION NOTE: - PRIOR TO FINAL INSPECTION BY THE ENGINEER, SYSTEM NEEDS TO BE COMPLETE INCLUDING BUILDUP FOR COVERS. Proposed EL= I I .O± ProO5ed EL=9.8± Min. INSPECTION PORT 9" Cover Min. 1: 10.0 DB -3 D -BOX H-20 Longest Run = 8'± LEACHING FIELD 45.0'x 15.0'x G.O" O PROP05ED GAS LINE (APPROXI'MATE) PROPOSED f\AI ING WALL T.O.W. EL= 9. ± VARIES TO EL=6.0± \ PROPOSED SWALE BOTTOM OF SWALE EL=4.)5± SYSTEM DESIGN CALCULATIONS: SEWAGE DESIGN FLOW: 4 BEDROOM DWELLING @ I 10 GPD = 440 GPD LEACHING CAPACITY REQUIRED: 4 BEDRO M5 (MAX.) @ 1 IQ GPD = 440 GPD REQUIRED SEPTIC TANK CAPACITY REQUIRED: DAILY FLOW = 440 GPD @ 200% = 880 GAL. REQUIRED SEPTIC TANK CAPACITY PROVIDED: 1 500 GALLON SEPTIC TANK (MIN. ALLOWED) LEACHING CAPACITY PROVIDED: ONE (1) 45.0'X 15.0'X G" LEACH FIELD CAN LEACH: Vt = (45.0 X 15.0) X 0.74 GPD/5F=499.5 GPD 499 GPD>440 GPD REQUIRED NOTE: A GARBAGE DISPOSAL 15 NOT PERMITTED WITH THI5 DESIGN. INSTALL: NE (1) - 1500 GALLON SEPTIC TANK ONE (1) - 3 OUTLET DISTRIBUTION BOX (H-20 Rated) ONE (1) - 45.0'x 15.0'x 6" LEACH FIELD MOSS ROAD 5LATERAL SOIL REMOVAL (SEE NOTE # I G) _- INSPECTION PORT c--� s I+ e -c 6 -0 -a -4,Q g2.22, L a e c- 48.24' -+..... _ -� Sx '. 40MILHDPEUNER LOG I I -05-9G EL=2.61 TOP @ EL=4. I + I I- I I_96 EL=2.49 BOTTO>.; @ L',=3.0± a' I n B ✓; PROPOSED LANL6CAPE WALL x 7.5 ' I 1-25-9G EL=2.25 TOP Of WALL VAR5 5 04-10-10 EL=2.40 5x9 i EL=2."5 HISTORIC HIGH GROUNDWATER O i., OO G b IS N ui J w J w 3 3 w N j 40MILHDPEUNER LOG I I -05-9G EL=2.61 TOP @ EL=4. I + I I- I I_96 EL=2.49 BOTTO>.; @ L',=3.0± I I -14-9G EL=2.25 PROPOSED LANL6CAPE WALL x 7.5 ' I 1-25-9G EL=2.25 TOP Of WALL VAR5 5 04-10-10 EL=2.40 5x9 EL=2."5 HISTORIC HIGH GROUNDWATER O o O N ui J w J w 3 3 w N j Q,�,e1\in9 PJd9eCI,_h X22'} , Bvddm0�e�9 I�PROFOSED 4 DeEJ 1 6.9 I x 7.0 POOL (EL= 13.0±) 10 PROPO GRADE 5 Existing Grade O 0 A 3/ MONITOR WELL LOG I I -05-9G EL=2.61 I I- I I_96 EL=2.49 I I -14-9G EL=2.25 I 1-25-9G EL=2.25 04-10-10 EL=2.40 EL=2."5 HISTORIC HIGH GROUNDWATER o O N ui J w J w 3 3 w N N U_ 0 O O M w w w d N <F G. 1' _ iED�. � I L EL=4.5± U 6' DEEP 5TONEN BED @ BOTTOM OF SWALE - 3/4"- 1 112" STONE; �- BOTTOM OF BED EL=4.0± 10 20 30 40 IN CROSS SECTION A -W: hORIZONTAL SCALE I "= 10' VERTICAL SCALE I "= 10' LENCHMARK: Tor of Water Gate E'.-5.6± (MSL 1929 NGVD Datum) 100 YR FLOOD PLAIN ZONE: Al2 ELEVATION= 10 FROM FEMA MAPS COMMUNITY PANEL #250015 0005D JULY 2, 1992 __TFTAT5N6 A PROPOSED SWALE BOTTOM EL=4.8± VELOCITY ZONE S - ALL AREAS OF THE FRONT PORTION OF THE DWELLING THAT ARE LOCATED WITHIN 20' OF PRIMARY* RESERVE 5.;.5. SHALL BE CONSTRUCTED U51 NG SLAB ON GRADE WITH A MINIMUM 5LA6 EL= 10.0 - PROPOSED 6" STONE BED @ BOTTOM OFSWALE 314" - I 1/2' STONE - PROPOSED 2' WIDE DRIP LINE TRENCH ON 3:1 SLOPE - COlI5TRUCT 3 CHECK DAMS TO SLOW RUN-OFF T -A PROPOSED WATERLINE 1(APPROXIMATE) 4.6 �lFer PAULETTE J. FINNERTY REVOCABLE TRUST PAULETTE J. FINNERTY, TRUSTEE CERTIFICATE OF TITLE # 177554 PARCEL 114 z !2 PROPOSED 2' WIDE DRIP LINE k •'"� ) TRENCH (f W.) ir 4 i PROPOSED OUTDOOR SHOWER TO 51T ON P CEEP 3/4" TO 1 1/2" GRAVEL n'=0 FOR DKAINAGE x ,9 � \ \ f O O ED ! 50 BuFfer Zone 5 K 6.3 ' r b" Bikar Zone PPOP05FD SWALE BOTTOM OF SWALE EL -4.5± PROPOSED LIMIT OF WORK (SEE CONSERVATION NOTE # 1) \ \ x 7.3 I to O O \ o i \ Over x 71 PR 5ED + 9S, PROPOSED POOL BACKWASH B -_D (SEE DU xx ET _ % r� S �- \` / rt -r O / 3.4/x\ SOP \I / /f.✓ SOP#2 \30�� DEP OBSERVATION 9 / s Vill 9.4 I _ _ �J 1 - /t/` / ', DEP OB5ERVATION PLOT #2 PROPOSED 5':✓ALE`- ' . •-•• / //}' 3.1 / BOTTOM EL='3.Om 7 ~� / / 4yy'aC� 1 1 x5.4 8 tills I � x62/ �i O WPROPORK LIAIT er ' / 3.4 '` l / 4 �. 3.6 �h Td", \ / / X4.4 x 5.5 / 5 / 4.0 t L� 4 � / LJ �� Revised 05/13110: Re' „ „ - „ JOSEPH N. PETROWSKI 4 � i Vegetated - 2 LAYER OF 1 /8 1 /2 STONE DEBRA T. PETROW5KI 3,9 wetland PLAN CAP LAND COURT DOCUMENT #543091 4111 3/4" - 1-1 /2" STONE PARCEL 121 ®-_ SCALE 1"=29 do Gregg L15ciot THIS AREA IS SERVED E SEV� 8.35 6 / BY TOWN WATER. SIT A:-. \ � 3.4 31 1 T J.M i,� Prol �- EL=2.75 HIGH GROUNDWATER LI - O 20 40 60 111 SCALE 1"=29 (508)898-8801 ib DATE: G:WA)obs\LI5eXoM Developmen!AMo 5Road127GAWwg\l 27GA.SD5.rev5-13-IO.dwg 04/21/10 FILE COPY . ii/F-�i�x 7.4 Ewsti Ridg e 2)ng Bwldrng zt N92e1ght_2 f.9'* VARIANCE REQUEST: SECTION 3.7 DISTANCE LOCATION OF DISPOSAL FACILITIES • SPECIFICALLY: THE REQUIREMENT OF "NO FILL SHALL BE DEPOSITED WHEN THE WATER TABLE 15 WITHIN FOUR (4) FEET OF THE ORIGINAL GRADE" • PROJECT 15 PROPOSING TO MOUND THE SEWAGE SYSTEM 50 AS TO MAINTAIN THE FIVE (5) FEET OF SEPARATION ABOVE GROUNDWATER TO THE BOTTOM OF THE 5.A.S. SEP 0 8 2010 HEALTH DEPT.