HomeMy WebLinkAbout37 Moss Road Title 5 Site Plan 31 ST FLOOR AT EL. 11.0' SYSTEM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO { /;9 p' MINIMUM .75' OF COVER OVER PREC ST WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM RUN PIPE LEVEL 2 DOUBLE WASHED PEASTOI 7.00' _ FOR FIRST 2' r PROP CRAWLSP. PROPOSED 1500 U 6.56' GALLON SEPTIC 6.31 ITEE TANK (H- 10) GAS o 8.58' -. a 8.79 8.62' o (2 % SLOPE) NOTE: FLOODZONE DEPTH OF FLOW = '4, FOUNDATION REQUIRED TEE SIZES: (DESIGN BY OTHERS) INLET DEPTH 1O" OUTLET DEPTH = 14" FOUNDATION- 22' ST ALARM AND CONTROL PANEL 7D BE INSTALLED INSIDE BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP ALARM FLOAT SWITCH SETTINGS, PUMP WORKING RAI 1000 GAL. H-10 500 GAL.+ RESE�RVE 1 8' BAFFLE 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) (-!-% SLOPE) ( % SLOPE) _PUMP 5. CHAMBER 3s' F SLOPE TODRAIN BACK TO PC WEEP HOLE CHECK VALVE MYERS SRM4 SUBMERSIBLE 4/10 HP PUMP SYSTEM (OR EQUAL) 0.58' PROVIDE INSPECTION PORT WITHIN 6" OF FINISH GRADE --, 3/4" TO 1 1/2" DOUBLE WASHED STONE D' BOX 6' LEACHING FACILITY 40 MIL POLY VINYL AND MASTIC ON INSIDE OF -10"-a RETAINING WALL 5 (6) /3 BARS CONT. FOR USE ADJ. WATER AT EL. 3.0 2% V HORIZONTAL REINFORCEMENT (TIDALLY INFLUENCED) 4.0': EL.6.5' (PROPOSED) _ #4 BARS 12" O.C. FOR VER11CAL .. REINFORCEMENT ..fi ,,..12 .. PUMP CHAMBER `t 5' REMOVAL OF UNSUITABLE SOIL rpt4,0, BASE EL. (NOT TO SCALE) REQUIRED AROUND PERIMETER OF-�2g•;. LEACHING FACILITY, DOWN TO ... . WATERPROOF/WATERTIGHT SUITABLE SOIL LAYER. REPLACE c1 [[� qQ WITH CLEAN MED. SAND. NATURAL SOIL PROVIDE VENT PITH CHARCOAL i1LTER- _ AND BUGSCREEN (FlNAL PLACEMENT PATH -- "f' �.5--- ^�DZO� CONC. RET. WALL (NTS) OMEOKNER CONSULTATION) - X - TEST HOLE LOGS ENGINEER: D.A. OJALA, SE WITNESS: LYNN MULKEEN DATE: 10/27/04 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# ELEV. Q 6.5' 0" 6.4' 0 2" A u, e d I � � LOCUS RADIO LANE covF a,,." ti 4 0" - LS 0 2" DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 . A ZONING DISTRICT: R-25 LS 6" 1OYR 3/2 YARD SETBACKS: B 6. LS FRONT = 30' 1OYR 5/8 30" SIDE = 15' C B Ms 48" OBS WATER + 6.3 2.5Y 6/6 96" BOARD OF HEALTH LAND SURVEYORS ELEV. Q 6.5' 0" 6.4' 0 2" A u, e d I � � LOCUS RADIO LANE covF a,,." ti SEPTIC DESIGN: (GARBAGE DISPOSE IS NOT ALLOWED ) NOTES: / S OVER H""0 UDl - - _ - T as - - DESIGN FLOW: a BEDROOMS (1 10 GPD) = 440 GPD / CITIES _-__ USE A 440 GPD DESIGN FLOW 1. DATUM IS NGVD - PROP. 6' HIGH CEDAR FENCE 6.Q _ -+ 6,2 SEPTIC TANK: 440 GPD ( 2 ) = 880 2. MUNICIPAL WATER IS AVAILABLE 7,0 9• �- ^ 206.00' - - _ 3 MINIMUM PIPE PITCH TO BE 1 /8" PER FOOT 1 I + 6,5 1 � -�� Pc I I � I tp 1 f I i PERVIOUS 1 CL ITH2 DRIVEWAY I I 10. 1 17.2 / +5.X / O PROPOSED 40 MIL LINER, AT 5' OFF SAS, TOP AT ELEVATION 9.0' (CONTINUE FROM / / •0 INSIDE OF WALL) 6.1 L=p3. 77' 0C -K5.8 MOSS ROAD + 5.9 104-290 El/5.3 / GAR AT EL 9.25' BENCHMARK: USE MAG NAIL AT ELEVATION 5.9' 1 O 0 ST 4X 40-+ 5.5 + .2 2�0 oR'G� \ Q¢ 0 \ \ PROP. DECK / PROP. 4 BR DWELLING FIRST FLOOR AT OR ABOVE ELEV. 11.0' 6R\1I, C\ APPROVED USE A 1500 GALLON SEPTIC TANK - LS ASSESSORS MAP 14 PARCEL 113 DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 . 0 ZONING DISTRICT: R-25 6' IOYR 3/2 YARD SETBACKS: - 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. FRONT = 30' BOTTOM: 40.5 x 15 (.74) = 449 SIDE = 15' 23,6211 SQ. B REAR = 20' THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT + 6.3 TOTAL: 607 PLAN REF. - LCP 14426 G BOARD OF HEALTH LAND SURVEYORS LS FLOOD ZONE: Al2 EL. 10 8• 1OYR 5/8 H-10 STANDARD 4.0' 36" 9• 3.4' REQUIRED INSPECTIONS AND CERTIFICATIONS AT SIDES, 3.3' BETWEEEN ROWS AND 1.5' AT ENDS 1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS OJALA, C DATE - COMPLETE. FROM BOARD OF HEALTH. 6. 2. ENGINEER SHALL STAKE FOOTING PRIOR TO POURING MS 3. ENGINEER SHALL INSPECT FOOTING AND REBAR PRIOR TO POURING OF WALL + 5.9 100.0 PROPOSED SPOT ELEVATION OF 4. ENGINEER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY _5' 50" OBS WATER 2.2' DEPOSITED S. SHALL INSPECT AND CERTIFY SEPTIC COMPONENTS AND 36 MOSS ROAD - PUMP MECHANISMS AFTER INSTALLATION EXISTING SPOT ELEVATION 2.5Y 6/6 ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT 100 PROPosED coNrouR IN THE RETAINING WALL, SEPTIC SYSTEM AND PUMP MECHANISMS HAVE -1.5 1 OB" _2 6' BEEN INSTALLED IN SUBSTANTIAL COMPLIANCE WITH THE APPROVED (WEST) YARMOUTH 100 PLAN. SEPTIC DESIGN: (GARBAGE DISPOSE IS NOT ALLOWED ) NOTES: / S OVER H""0 UDl - - _ - T as - - DESIGN FLOW: a BEDROOMS (1 10 GPD) = 440 GPD / CITIES _-__ USE A 440 GPD DESIGN FLOW 1. DATUM IS NGVD - PROP. 6' HIGH CEDAR FENCE 6.Q _ -+ 6,2 SEPTIC TANK: 440 GPD ( 2 ) = 880 2. MUNICIPAL WATER IS AVAILABLE 7,0 9• �- ^ 206.00' - - _ 3 MINIMUM PIPE PITCH TO BE 1 /8" PER FOOT 1 I + 6,5 1 � -�� Pc I I � I tp 1 f I i PERVIOUS 1 CL ITH2 DRIVEWAY I I 10. 1 17.2 / +5.X / O PROPOSED 40 MIL LINER, AT 5' OFF SAS, TOP AT ELEVATION 9.0' (CONTINUE FROM / / •0 INSIDE OF WALL) 6.1 L=p3. 77' 0C -K5.8 MOSS ROAD + 5.9 104-290 El/5.3 / GAR AT EL 9.25' BENCHMARK: USE MAG NAIL AT ELEVATION 5.9' 1 O 0 ST 4X 40-+ 5.5 + .2 2�0 oR'G� \ Q¢ 0 \ \ PROP. DECK / PROP. 4 BR DWELLING FIRST FLOOR AT OR ABOVE ELEV. 11.0' 6R\1I, C\ APPROVED + 5.1/ 1500 GAL H-10 (SHOREY) ST WGT. 11480 LBS 20 0 20 40 80 / 1.19' x 10.5 x 5.67 x 62.4 = 4420 (OKAY) 1000 GAL H-10 (SHOREY) PC WGT 8240 LBS 1.24' x 8s x 4.8 z 62.4 3157 LBS (OKAY) SCALE: 1 " = 20' DATE: DECEMBER 7, 2004 132.30' DATE USE A 1500 GALLON SEPTIC TANK - LEACHING: 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 . 0 LSH OF /44 �� tiG 5. PIPE JOINTS TO BE MADE WATERTIGHT. SIDES: N/A 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. LOT 58 BOTTOM: 40.5 x 15 (.74) = 449 ENVIRONMENTAL CODE TITLE V. 23,6211 SQ. CIVIL ENGINEERS 7• THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT + 6.3 TOTAL: 607 S.F. 449 GPD BOARD OF HEALTH LAND SURVEYORS TO BE USED FOR ANY OTHER PURPOSE. USE 40.5' x 15' LEACH FIELD OF 2 ROWS OF 6 8• PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. H-10 STANDARD INFILTRATORS EACH, WITH 3' STONE 9• COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT AT SIDES, 3.3' BETWEEEN ROWS AND 1.5' AT ENDS INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED OJALA, , P.L.S. DATE FROM BOARD OF HEALTH. 6. LEGEND TITLE S SITE PLAN + 5.9 100.0 PROPOSED SPOT ELEVATION OF + 5.7 0 36 MOSS ROAD 100+0 EXISTING SPOT ELEVATION 100 PROPosED coNrouR IN THE TOWN OF: (WEST) YARMOUTH 100 EXISTING CONTOUR PREPARED FOR: SAM TRAYWICK BUOYANCY CALCS: + 5.1/ 1500 GAL H-10 (SHOREY) ST WGT. 11480 LBS 20 0 20 40 80 / 1.19' x 10.5 x 5.67 x 62.4 = 4420 (OKAY) 1000 GAL H-10 (SHOREY) PC WGT 8240 LBS 1.24' x 8s x 4.8 z 62.4 3157 LBS (OKAY) SCALE: 1 " = 20' DATE: DECEMBER 7, 2004 132.30' DATE off 508-362-4541 fox 508 362-9880 . down cdtDe engineering, inc, LSH OF /44 �� tiG SNC- �� AHE +3.5 �a oala ` CIVIL ENGINEERS CIVIL (1JAUA BOARD OF HEALTH LAND SURVEYORS �� No. 307 N0. �4a ��.. ". MA 939 main st, yarmouth, ma 02675 :r'' A OJALA, , P.L.S. DATE