HomeMy WebLinkAbout37 Moss Road Title 5 Site Plan 41ST FLOOR AT EL. 1 1.OI I' S E I I PROFILE PROVIDE INSPECTION PORT WITHIN (NOT TO SCALE) 6" OF FINISH GRADE ACCESS COVER TO WITHIN 6" OF FIN. GRADE //-- ACCESS COVER (WATERTIGHT) TO O MINIMUM .75' OF COVER OVER PRECAST / WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM 9.75' 2" DOUBLE WASHED jEA TONE" m RUN PIPE LEVEL / 9 0' FOR FIRST 2' 7.00' PROPOSEDr500 .. PROP CRAWLSP GALLON S 6.31' a TEE o 8.58' 6.56'. TANK (H- GAS o �•62' 0.58' o BAFFLE Q 8.79' 80$ oa 8.0'. TEST HOLE LOGS ENGINEER: D.A. OJALA, SE LYNN MULKEEN WITNESS: DATE: 10/27/04 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# C� ELEV. Q ' (? SLOPE) �6" CRUSHED STONE OR MECHANICAL 66-5, 0" 6.4 COMPACTION. (15.221 [2]) O' t 3/4" TO 1 1/2" DOUBLE WASI,'ED STONE sr NOTE: FLOODZONE DEPTH OF FLOW = 4 (_I-_% SLOPE) (--L% SLOPE) O 0 FOUNDATION REQUIRED TEE SIZES: 2" LOCATION MAP NTS (DESIGN BY OTHERS) 10' 2" INLET DEPTH = A A - OUTLET DEPTH 14" PUMP LEACHING 5. ASSESSORS MAP 14 PARCEL 113 36' D' BOX 6' FACILITY LS LS ZONING DISTRICT: R-25 FOUNDATION- 22', ST 5 CHAMBER 1OYR 3/2 1OYR 3/2 YARD SETBACKS: ALARM AND CONTROL PANEL 40 MIL POLY VINYL AND 6" 6" FRONT = 3' TL.BE=INSTALLED.INSIDE MASTIC ON INSIDE OF SIDE = 15' BUILDING.: ALARM IN BE ON - .10"_4 RETAINING WALL B B REAR = 20' EL 9.0' PLAN REF. - LCP 14426 G SEPARATE CIRCUIT FROM PUMP FLOOD ZONE: Al2 EL 10 - 9.0' LS LS (6) #3 BARS CONT. FOR USE ADI. WATER AT EL. 3.0' 10YR 5/8 t OYR 5/8 REQUIRED INSPECTIONS AND CERTIFICATIONS INV, IN 6.26' 2' PRESSURE UNE 3.4' 1000 GAL. S/ 2. ' HORIZONTAL REINFORCEMENT (TIDALLY INFLUENCED) 3O" 4.0' 36" 500 GAL,+ SLOPE TO DRAIN BACK TO PC 1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS ALARM ON RESERVE WE HOLE 4.0`. EL.6.5' (PROPOSED) O O COMPLETE. 2. ENGINEER SHALL STAKE FOOTING PRIOR TO POURING FLOAT SWITCH CHECK VALVE 5.0' P. 3. ENGINEER SHALL INSPECT FOOTING AND REBAR PRIOR TO POURING SETTINGS PUMP ON - #4 BARS 12" O.C. FOR VERTICAL B, MS OF WALL WORKING RANGE MY RS SRM4 •:.. REINFORCEMENT MS 4. ENGINEER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY 5.3' SUBMERSIBLE 4/1D HP PUMP DEPOSITED 1. PUMP OFF 8' SYSTEM (OR EQUAL) ^6% "12• 48" OBS WATER 2.5' 50" ODS WATER 2.2' S. ENGINEER SHAII INSPECT AND CERTIFY SEPTIC COMPONENTS AND PUMP MECHANISMS AFTER INSTALLATION + o�000 00 o000 0000 - r1" CHAMBER. - � �4,0' BASE EL I ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT PUMP 5' REMOVAL OF UNSUITABLE SOIL - j 2.5Y 6/6 2.5Y 6/6 THE RETAINING WALL. SEPTIC SYSTEM AND PUMP MECHANISMS HAVE REQUIRED AROUND PERIMETER OF '`•-D`,',: ( BEEN INSTALLED IN SUBSTANTIAL COMPLIANCE WITH THE APPROVED _. _....: ... 108" -2.6' PLAN. (NOT To SCALE) �> 96" -1.5 LEACHING FACILITY. DOWN TO � m �.. 7-2- WATERPROOF/WATERTIGHT SUITABLE SOIL LAYER. REPLACE NATURAL SOIL - _ WITH CLEAN MED. SAND. ARCOAL�rI PROMDE VENT w; CHLrm - 'CONC. RET. WALL NTS) '`I SEPTIC DESIGN: (GARBAGE DISPOSER IS NInT AI I nWFD ) NOTES:. AND BUGSCREEN (FINAL PLACEMENT VATH - - - „� racy - _ RADIO LANE ; ) - 440 GPD ; V G E J : _ OMEOWNER CONSULTATION) DESIGid FLO'v'r: 4 BE^vRGOivIS (110 GPD - - - - _ _ -I USE A 440 GPD DESIGN FLOW 1. DATUM IS NGVD _ --h ZQ - - I 2 2. MUNICIPAL WATER IS AVAILABLE �5 - OVER Ni IJTIL1TlES - - - SEPTIC TANK: 440 GPD (_) = 880 ® - - PROP. 6' HIGH CEDAR FENCE - + 6.2 -- USE A 1500 GALLON SEPTIC TANK 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 6.0 ��' 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 LEACHING• E WATERTIGHT 7.0 5. PIPE JOINTS TO BE MAD IN ACCORDANCE WITH MASS. 0 SIDES: 6. CONSTRUCTION DETAILS TO BE 40 5 x 15 (74) = 449 ENVIRONMENTAL CODE TITLE V. SYSTEM ONLY AND IS NOT BOTTOM: I+ TH1 7. THIS PLAN IS FOR PROPOSED SEPTIC I i 6. I TO BE USED FOR ANY OTHER PURPOSE. +5.5 23,621± S0. USE 40.5' x 15' LEACH FIELD OF 2 16. 8. GAR AT EL•+ M WITH 3' STONE 9. 5.3 I . \ INSPECTION BY BOARD OF HEALTH AND (o LLu Of I TT�2 / FROM BOARD OF HEALTH. 0. ' +-7.2 + 5.8 a , PROPOSED 40 MIL ' LINER, AT 5' OFF SAS. TOP AT ELEVATION 9.0' r (CONTINUE FROM INSIDE OF WALL) - / PROP. O , / .p % DRIVEWAY R / L=83.77' / , 3� 8.0 � 9,0 X00 PC 0 ST + .2 PROP. 4 SR DWELLING FIRST FLOOR 1108 ABOVE ELEV. 5• , / � q '2 _K5.8 MOSS ROAD � 1 5.5 + 5.9 BENCHMARK: USE MAG NAIL AT ELEVATION 5.9' BUOYANCY CALCS: _. 18' x05 x5.67x 62.4 4420 A1007 W1 480 LBS 1(OKAY) 1000 GAL H-10 (SHOREY) PCWGT 8240 LBS 1.24' x 8.5 x 4.8 x 62.4 Q 3157 LBS (OKAY) 04-290' PROP. DECK _ N/A -7 5. PIPE JOINTS TO BE MAD IN ACCORDANCE WITH MASS. 0 SIDES: 6. CONSTRUCTION DETAILS TO BE 40 5 x 15 (74) = 449 ENVIRONMENTAL CODE TITLE V. SYSTEM ONLY AND IS NOT BOTTOM: 7. THIS PLAN IS FOR PROPOSED SEPTIC LOT 58 TOTAL: 607 S.F. 449 GPD TO BE USED FOR ANY OTHER PURPOSE. +5.5 23,621± S0. USE 40.5' x 15' LEACH FIELD OF 2 ROWS OF 6 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. + 6.3 H-10 STANDARD INFILTRATORS EACH, WITH 3' STONE 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT PERMISSION OBTAINED AT SIDES, 3.3' BETWEEEN ROWS AND 1.5' AT ENDS INSPECTION BY BOARD OF HEALTH AND FROM BOARD OF HEALTH. PROP. LINER AT EDGE OF ROCK WALL + 51ST COBBLES ° 4.8 132.30' GRGR=�-"E L/NEp APPROVED DATE +5.7 + 3.5 BOARD OF HEALTH , MA LEGEND + 5,5 100.0 PROPOSED SPOT ELEVATION O 0 nj 100+0 EXISTING SPOT ELEVATION F1 001 PROPOSED CONTOUR 100- EXISTING CONTOUR �R ��= m. 509 393-9990 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 morin St. yarmouth, ma 02675 TITLE 5 SITE PLAN OF 36 MOSS ROAD IN THE TOWN OF: (WEST) YARMOUTH PREPARED FOR: SAM TRAYWICK 20 0 20 40 80 -1 SCALE: 1 = 20 DATE: DECEMBER 7, 2004 REV. 3/9/05 ® .Of fdA5s9 4i\�H OF I,,y��4 I`•di Fri( i (i 2��5 OJAv{ Yarr^Duth Water Dept. CIV No E H. OJ P.L.S. DATE