Loading...
HomeMy WebLinkAbout37 Moss Road Title 5 Site Plan1ST FLOOR AT EL. 11.0' SYSTEM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) � ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER S ' RUN PIPE LEVEL 2 DOUBLE WASHED P ^ 7.00' _ /FOR FIRST 2' r PROP'CRAWLSP PROPOSED 1500 0 Fl - 6.56' GALLON SEPTIC 6.31 TEE TANK. (H- 10 ) GAS °- 8.62' •,.:.. BAFFLE 8.79' �� 0.58' (-z-7 SLOPE) �__6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) PROVIDE INSPECTION PORT WITHIN 6" OF FINISH GRADE - --, NOTE:DAFLZONETIOODREOUIREO DEPTH. OF FLOW = `1' ( Z SLOPE) ( 9. SLOPE) 3/4" TO 1 1/2" DOUBLE WASHED STONE (DESIGN BY OTHERS) TEE SIZES: INLET DEPTH = 10" `-' OUTLET DEPTH = 14" FOUNDATION- 22' ST s' PUMP 38• D' BOX s' LEACHING CHAMBER FACILITY ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON 40 MIL POLY VINYL AND SEPARATE CIRCUIT FROM PUMP MASTIC ON INSIDE OF - EL. 9.0' 10" I RETAINING WALL INV. IN 6.26' LINE 5' 1000 GAL. H-10 S/ 2 PRESSURE_. (6)3.BARS CONT. FOR 500 GAL.+ SLOPE TO DRAIN BACK TO PC I HORIZONTAL REINFORCEMENT USE ADJ. WATER AT EL. 3.0' ALARM ON RESERVE WEEP HOLE 2'• (TIDALLY INFLUENCED) FLOAT SWITCH SETTINGS: PUMP ON 8' CHECK VALVE S.0' 4'0'•r EL.6.5' (PROPOSED) WORKING RANGE UVCDRM4 $4 BARS 12" O.C. FOR VERTICAL 5.3SUBMERSIBLE 4/10 HP PUMP .. REINFORCEMENT PUMP OFF B' SYSTEM (OR EQUAL) 6. op00000 CHAMBER �u'p PUMP E I I A M D E R 5' REMOVAL OF UNSUITABLE SOIL - 4.0' BASE. EL (NOT TO SCALE) REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO WATERPROOF/WATERTIGHT SUITABLE SOIL LAYER. REPLACE M - - - - WITH CLEAN MED. SAND. NATURAL SOIL PROVIDE VENT SCREEN TH CHARCOCEME`TR•-_ - CONC. RET. WALL (NTS) AND BUCSCREEN (FINAL PLACEMENT NTH - - - T OMEOWNER CONSULTATION) - + 7.5. _ RADIO ,[JANE OVER HEAD ,UTILITIES - - -I- 5.8 - - - - ® - - PROP. 6' HIGH CEDAR FENCE 6 - -1- 6.2 TEST HOLE LOSS ENGINEER: D.A. OJALA, SE WITNESS: LYNN MULKEEN DATE: 10/27/04 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# Q ELEV. Q p" 6_5' p" 6.4' � 0 2„ 2" A LS 6" 1OYR 3/2 A LS 6" 1OYR 3/2 B LS 1OYR 5/8 30" C MS 48" OBS WATER 2.5Y 6/6 B LS 1OYR 5/8 LOCUS oRADIO UNE COVE ROgp MOSS pop s e LOCATION MAP NTS ASSESSORS MAP 14 PARCEL 113 ZONING DISTRICT: R-25 YARD SETBACKS FRONT = 30' SIDE = 15' REAR = 20' PLAN REF. - LCP 14426 G FLOOD ZONE. Al2 EL 10 36" 3.4' REQUIRED INSPECTIONS AND CERTIFICATIONS 1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS C 2. ENGINEER SHALL STAKE FOOTING PRIOR TO POURING 3. ENGINEER SHALL INSPECT FOOTING AND REBAR PRIOR TO POURING MS OF WALL 4. ENGINEER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY SO" OBS WATER Q,Q' DEPOSITED' _ 5. ENGINEER SHALL INSPECT AND CERTIFY SEPTIC COMPONENTS AND PUMP MECHANISMS AFTER INSTALLATION 2.5Y 6/6 ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT / - THE RETAINING WALL. SEPTIC SYSTEM AND PUMP MECHANISMS HAVE 96 I -1.5 108" L_ SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) o 206.00' - - 440 GPD USE A 440 GPD DESIGN FLOW 7,0 ) 0 USE A 1500 GALLON SEPTIC TANK m 8.0 .0 SIDES: N/A r _ 90 , TOTAL: 607 S.F. 449 GPD _ 0 00 H-10 STANDARD INFILTRATORS EACH, WITH 3' STONE +6. TH 1 PG LOT 58 ST + 5.5 23,621± SQ. + 6.3 I + .2 (0 6. CAR AT EL 9 W 5.3 0 Ed Lj I •� IT'r(2 ' f 9O + 7,2 0, --" J \`\® PROP. DECK + 5.8%%s9 PROP. 4 BR - 9.8' / DWELUNG PROPOSED 40 MIL /OR ' FIRST FLOOR AT + 5.7 LINER, AT 5' OFF SAS, ABOVE ELEV. 11.00'' OO TOP AT ELEVATION 9.0' , ,� '0 .(CONTINUE FROM ' _N INSIDE OF WALL) PROP. - PERVIOUS 6 '0 / DRNEWAY Q �RCh 6.1 % _ PROP. UNER AT EDGE OF / ROCK WALL 5,5 + o. 4 .z -K5.8 MOSS ROAD t 1 0 i + 5,9 5.5 i 4 COBBLE 4.8 132.30' GRR SEL SRI VE LINED [ATENCHMARK: USE MAG NAIL d ELEVATION 5.9' BUOYANCY CALCS: + 3.5 1500 GAL H-10 (SHOREY) ST WGT. 11480 UBS 1.19' x 10.5 x 5.67 x 62.4 - 4420 (OKAY) - 1000 GAL H-10 (SHOREY) PC WGT 8240 UBS BOARD OF HEALTH 1.24' x 8.5 x 4.8 x 62.4=3157 LBS (OKAY) O4-'290 , MA APPROVED DATE TEST HOLE LOSS ENGINEER: D.A. OJALA, SE WITNESS: LYNN MULKEEN DATE: 10/27/04 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# Q ELEV. Q p" 6_5' p" 6.4' � 0 2„ 2" A LS 6" 1OYR 3/2 A LS 6" 1OYR 3/2 B LS 1OYR 5/8 30" C MS 48" OBS WATER 2.5Y 6/6 B LS 1OYR 5/8 LOCUS oRADIO UNE COVE ROgp MOSS pop s e LOCATION MAP NTS ASSESSORS MAP 14 PARCEL 113 ZONING DISTRICT: R-25 YARD SETBACKS FRONT = 30' SIDE = 15' REAR = 20' PLAN REF. - LCP 14426 G FLOOD ZONE. Al2 EL 10 36" 3.4' REQUIRED INSPECTIONS AND CERTIFICATIONS 1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS C 2. ENGINEER SHALL STAKE FOOTING PRIOR TO POURING 3. ENGINEER SHALL INSPECT FOOTING AND REBAR PRIOR TO POURING MS OF WALL 4. ENGINEER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY SO" OBS WATER Q,Q' DEPOSITED' _ 5. ENGINEER SHALL INSPECT AND CERTIFY SEPTIC COMPONENTS AND PUMP MECHANISMS AFTER INSTALLATION 2.5Y 6/6 ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT / - THE RETAINING WALL. SEPTIC SYSTEM AND PUMP MECHANISMS HAVE 96 I -1.5 108" L_ SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) DESIGN FLOW: °_ BEDROOMS (110 GPD) = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2 ) = 880 USE A 1500 GALLON SEPTIC TANK LEACHING: SIDES: N/A BOTTOM: 40.5 x 15 (.74) = 449 TOTAL: 607 S.F. 449 GPD USE 40.5' x 15' LEACH FIELD OF 2 ROWS OF 6 H-10 STANDARD INFILTRATORS EACH, WITH 3' STONE AT SIDES, 3.3' BETWEEEN ROWS AND 1.5' AT ENDS + 5.9 LEGEND 100.0 PROPOSED SPOT ELEVATION 100+0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - 100- EXISTING CONTOUR I= NO xz-seao down cape engineering, Inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouth, ma 02675 BEEN INSTALLED IN SUBSTANTIAL COMPLIANCE WITH THE APPROVED -2.6' PLAN. NOTES: 1. DATUM IS NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. TITLE 5 SITE PLAN OF 36 MOSS ROAD IN THE TOWN OF: YARMOUTH PREPARED FOR: SAM TRAYWICK 20 0 20 40 80 SCALE: 1 = 20' DATE: DECEMBER 7, 2004 REV. 3/9/05 N r2ooy >. DATE