Loading...
HomeMy WebLinkAbout23 New Hampshire Ave - Site Plan 2WALL & REMOVAL DETAILS ADJACENT GRADE VARIES --MAX: WALL HEIGHT=10" SCALE: PROPOSED WALL 1' OFF 1 »-20' LINE UNILOCK CONCORD OR ROMAN WALL PROPOSED TOP WALL=8.1 ONE BLOCK COURSE BELOW GRADE LOCK CONCORD OR ROMAN WALL PROPOSED TOP WALL=8.1 ADJACENT GRADE VARIES --MAX. WALL HEIGHT=18" WALL SECTION SCALE: 1 "=2' 8" X 6" 14" INTERLOCKING BLOCKS COMPACTED GRANDULAR BASE 22" WIDE & B" DEEP REV. 7/15/08 --PROPOSED FOOTPRINT, LOT COVERAGE & OFFSETS REV. 6/18/08--2 SEPTIC SYSTEMS & NEW OWNER REV. 5/30/08 --WALL CROSS SECTION REV. 5/29/08--C-4 UNITS REV. 5/23/08 --PRESBY SYSTEM COPING WALL 1' OFF PROPERTY LINE REPLUMB SEWER OUT FRONT PROPOSED. INVERT 30" BELOW GRADE." DOUBLE SLEEVE BOTH SEWER AND WATER WITI-IIN 10' OF EACH OTHER. ALARM & PUMP NOTES 1. ALARM TO BE WIRED BY ELECTRICIAN ON SEPARATE CIRCUIT FROM PUMP. 2. ELECTRICAL WORK TO BE INSPECTED BY WIRING INSPECTOR. 3. ALARM TO BE LOCATED IN HOUSE. 5, USE 2 MEYER ME3H, 3/10 HP PUMPS, OR EQUIVALENT. 6, TO PROVIDE FOR EASY AND SAFE MAINTENANCE OF PUMP: WIDE UNION/DISCONNECT IN 2" PVC AT TOP PUMP CHAMBER SO PUMP BE REMOVED FROM TOP OF TANK. MONOLITHIC 1000 GALLON H-10 PUMP CHAMBER W/ WATERPROOFING 3/8" WEEP/VENT HOLES SYSTEM B --UNIT 25 Invert 5.75 71 S-1 /8"/ft Invert 5.55 I Proposed I Bottom 1.05 1 Proposed 6" Stone DESIGN DATA 4 CULTEC C-4 UNITS Invert 5.30 24' X 12' X 3" DEEP SAND BEDS Use Gas Baffle (See Detail) Existing Invert 6.80 Use 12" Cover Proposed with 7.21 see detail Flow Equilizers Top Ur P S=1 /8"/ft Sanitary Tee Invert 8.97/ invert 5.75 J (Proposed Proposed , 1 1 5' 1 1 1 4 t-5 ] 1421 I F- 4' CD I 4' t" Inspection Port 3" E 6.5 Level Bottom C-4 Units j 0.15' Adjustment Pro- vided --Locus is within -300'of.coast BEDROOMS: 2 GARBAGE GRINDER: No LEACH AREA REQUIRED CAPACITY. 220 GPD USE 2 C-4 UNITS WITH 4' OF STONE ALL AROUND SEPTIC TANK: 1500 GAL. FOR A 24` X 12' X 3" DEEP LEACH AREA, MINUS BOTTOM :LEACHING AREA: 287.3.SF A 1' X 17" TRIANGLE, AS SHOWN. RUN PERFOR- [(24' X 12')] - 1'/2 X 1.42 ATED PIPE DOWN CENTER OF C-4 UNITS BETWEEN SIDE LEACHING AREA: 17.8 .SF HUMPS. CAPE END. BRING STONE TO TOP OF C-4 [(71.3' PERIMETER) x 0.25] UNITS AND COVER WITH FILTER CLOTH. DESIGN CAPACITY. 225 GPD [(287.3 SF + 17.8 sf) X .74 GPD/SF] 2' MIN. REMOVAL WITH BARRIER PUMP CHAMBER STORAGE CAPACITY. 220 GAL DO ALL AROUND AND UNDER REMOVAL DOWN 37"f DOSES PER DAY: 2 TO LOAMY SAND, AS SHOWN. BUOYANCY CALC'S-MONOLITHIC PUMP CHAMBER WEIGHT OF EMPTY CHAMBER AND 24" OF COVER CHAMBER= 4.15 TON (PER SHOREY) 24" COVER= 2' X 5.42' X 8.25' X 0.055 TON/CU. FT. 24" COVER=4.92 TON TOTAL= 4.15 TON + 4.92 TON=9.07 TON WEIGHT OF WATER --HIGH GROUNDWATER DOWN (3.0 -0.75') X 5.42' X 8.25' X 0.0312 TON/CU. FT. WEIGHT WATER=3.14 TON TANK AND 24" COVER ARE HEAVIER BY 5.9 TON. 0.75 IMPERVIOUS BARRIER 40 MIL TITLE 5 SAND 2" PVC Alarm 34" On 28" Quick Disconnect/ Off 24" Unions P Check Valves 6" STONE tNDER MAKE FACTORY WATER -TIGHT tFA OF,U,y S. C5 R I _ CADILLA 41060 R�GISTER�O 'SANITARIP" 5 1 S HEALTH AGENT APPROVAL CADILLAC ,# 35779 BUOYANCY CAL'S MONOLITHIC 1500 GAL. H-10 WEIGHT OF EMPTY SEPTIC TANK AND 20" OF COVER TANK= 5.635 TON (PER SHOREY) 20" COVER=1.67' X 6.08' X 10.17' X 0.055 TON/CU. FT 20" COVER=5.68 TON TOTAL= 5.635 TON + 5.68 TON = 11.31 TON WEIGHT OF WATER ---HIGH GROUNDWATER DOWN (3.0 -1.05) X 6.08' X 10.17' X 0.0312 TON/CU. FT. WEIGHT WATER= 3.76 TON TANK AND 20" COVER ARE HEAVIER BY 7.5 TON. SITE PLAN FOR . JAMES G. MORRISON LOT 1061 23 & 25 NEW HAMPSHIRE AVE, W. YARMOUTH, MA NOVEMBER 28, 2003 SCALE: 1"=20' RONALD J. CADILLAC, PLS, RS, P.C. PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 DATE 2008 BY R.J. CADILLAC (508) 775-9700 PAGE 2 OF 2