1. GENERAL
The contractor shall furnish and
Install (1) HlghStrengthFAST 1.0
treatment system as manufactured by
Bio-Microbics, Inc. The treatment
system shall be complete with all
needed equipment as shown on the
drawings and specified herein.
The principal Items of equipment shall
Include FAST System Insert, Insert lid
(or teg extensions If that option Is
chosen), blower assembly, blower
controls and alarms. The
HlghStrengthFAST 1.0 unit shall be
situated within a 500 gallon minimum
compartment tank, as shown on the
plans, or in a 1250 gallon one
compartment tank. Tank(s) must
conform to local, state, and all other
applicable codes. The contractor shalt
provide coordination between the FAST
system and tank supplier with regard
to fabrication of the tank, Installation
of the FAST unit and delivery to the
job site.
2. OPERATING CONDTIONS
The HlghStrengthFAST 1.0 treatment
system shall be capable of treating
the wastewater from all facilities
producing appropriate waste to develop
and sustain a viable biomass. Waste
containing inhibitory substances is not
recommended for treatment in the
FAST system. Consult factory for
proper sizing and usage.
3. MEDIA
The FAST media shall be manufactured
of rigid PVC, polyethylene or
polypropylene and it shall be
supported by the polyethylene Insert.
The media shall be fixed in position and
contain no moving or wearing parts and
shall not corrode. The media shall be
designed and Installed to ensure that
sloughed solids Immediately descend
through the media to the bottom of
the septic tank.
4. BLOWER
The HlghStrengthFAST 1.0 unit shall
come equipped with a regenerative type
blower capable of delivering 32-36 CFM.
The blower assembly shall Include an
Inlet fitter with metal fitter element.
2' (5cm)
1.25' 9.25' 9' _
(3.2cm) r-(6.5cm) 1 (22.9cm)
17'
(43.2cm) (22.9.9cm)
1.25'
<3.2cm)
TYP 22.75' (57.8cm)
BLOWER H❑USING BASE
DIMENSIONS (SECTION A -A)
Aj_
4'
(10.2cm)
IV
.ai,- NFOI;JV4011111i N
UA
•
6' (15.2cm)-�
VENTS
W/FAST LID
14'
(35.6cm>
5'
(12.7cm)
N
BLOWER
HOUSING
DIMENSIONS
Wastewater Treatment System
5. REMOTE MOUNTED BLOWER
The blower may be mounted remote
with no more than 100 ft (30.5 M) of
piping and no more than four elbows,
from the HlghStrengthFAST unit on a
contractor supplied concrete base.
The blower must not set in standing
water and Its elevation must be higher
than the normal flood level. A
two-piece, rectangular housing shall
be provided with tamper -proof screws.
The discharge air line from the blower
to the HlghStrengthFAST shall be
provided and Installed by the
contractor.
6. ELECTRICAL
The electrical source should be within
150 feet of the blower. Consult local
code for longer wiring distances. All
wiring must conform to code. The Input
power required for the blower is
115/230 Volts, Single Phase, 60/50
Hertz, 3.8/1.9 Full Load Amps, minimum
wire size Is 14 A.W.G. (Locked Rotor
Amps are 18.6/9.3). All conduit and
wiring between the electrical control
panel (optional), the power supply, and
the blower shall be furnished and
Installed by the contractor.
7. ALARMS
The alarm system shalt consist of a
visual and audible alarm to indicate
toss of power to the blower and/or
high water level. A manual silence
switch is Included.
8. INSTALLATION AND OPERATI❑N
INSTRUCTIONS
Alt work must be done in accordance
with local codes and regulations.
Installation of the HlghStrengthFAST
1.0 shall be done in accordance with
the written Instructions provided by
the manufacturer. No more than four
feet of fill may be placed over the
FAST lid. Operation manuals shall be
furnished which will Include a
description of installation, operation,
and system maintenance procedures.
There shall be a separate manual for
the Installer, service provider, and
owner, tailored to each.
7.25
(18.acm)
8' (30.5cm)
20.3cm3-I
TYP
PLAN VIEV Ll
LEG EXTENSI❑N
SEE NOTE 3.
4.
4.212CRU 40
PVC PVE--*.,�
3.875' cur
(9.8cm)
NOTES
1. SECURE ORIGINAL 7' X 7' FOOT TO LEG EXTENSION
BY PLACING TWO (2) SCREWS IN EACH SIDE OF THE
LEG EXTENSION. EIGHT (8) SCREWS PER FOOT ARE
INCLUDED AND SHOULD BE USED ON EACH OF THE
FOUR (4) CORNER LEG EXTENSIONS.
2. ANCHOR THE LEG EXTENSIONS (4 CORNER LEGS
ONLY) TO THE BASE OF THE TANK. PLACE BOLTS
AT OPPOSITE CORNERS OF THE LEG EXTENSION
BASE,
3. TO ELONGATE FOOT PAST THE PROVIDED 12', CUT
THE 3.9' LEG EXTENSION IN THE CENTER INTO TWO
SEPARATE PIECES. THEN CUT A SCH 40 PVC PIPE
TO THE DESIRED LENGTH AND SLIP THE PIPE OVER
THE TOP AND BOTTOM CUT SECTIONS OF THE LEG
EXTENSIONS.
4. ATTACH PIPES WITH STAINLESS STEEL SCREWS.
5. VENT TO BE LOCATED ABOVE FINISH GRADE OR
HIGHER TO AVOID INFILTRATION. CAP WITH 6' VENT
GRATE W/AT LEAST 9.1 SQ. IN. OF OPEN SURFACE
AREA. SECURE WITH STAINLESS STEEL SCREWS (SEE
HSF 1.0 L DWG).
OR
RUN VENT TO DESIRED LOCATION AND COVER
OPENING WITH 3' VENT GRATE. SECURE WITH
STAINLESS STEEL SCREWS. VENT MUST NOT ALLOW
EXCESS MOISTURE BUILDUP OR BACK PRESSURE.
IN THE INTEREST OF TECHNOLOGICAL PROGRESS, ALL PRODUCTS ARE
BIO- MI R BIC 6IHighStrengthFAST®1.0 X
JTR o a
1-800-753-FAST(3278)
9. WARRANTY
The manufacturer of the HlghStrengthFAST 1.0
treatment system shall warrant for
eighteen months from the date of
shipment or one year from the date
of start-up, whichever occurs first,
that the equipment they provide will
be free from defects In material and
workmanship.
In the event a mechanical component falls to
perform as specified or is proven
defective in service during the
warronty period, the manufacturer
shalt repair or replace such defective
parte (Cost of labor on
repair/replacement Is not covered
under this warranty. The replacement
or repair of those Items normally
consumed In service such as air fitter,
etc., shalt be considered as part of
routine maintenance and upkeep.
It is not intended that th
manufacturer assume r snnnsin1(tty_ for
detects In design. material or
workmanship. or delays in delivery.
replacement, or otherwise
10. FLOW AND D❑SING
Wastewater treatment systems work
best when Influent flow Is delivered as
consistently as possible. FAST systems
have been successfully designed, tested
and certified recieving gravity,
demand -based Influent flow. When
Influent flow Is controlled (either by
pump or other means) to the FAST
system to help with highly variable flow
conditions, then multiple feeding events
should be used to help assure even
flow, optimum performance, and reliability.
IN THE INTEREST OF TECHNOLOGICAL PROGRESS, ALL PRODUCTS ARE
SUBJECT TO DESIGN AND/OR MATERIAL CHANGE WITHOUT NOTICE.
BIO- MI R�BICS o HighStrengthFAST01.0 S
1-800-753-3278(FAS
r- by BMI
NOTES
I.BLOWER PIPING TO FAST MAY NOT EXCEED 100
FT (2).5m) TOTAL LENGTH AND USE A MAXIMUM
Or 4 ELBOWS IN THE PIPING SYSTEM (0 100
FT). FOR DISTANCES GREATER THAN 100
FT --CONSULT FACTORY. BLOWER MUST BE
LOCATED ABOVE FLOOD LEVELS.
2. VENT TO BE LOCATED ABOVE FINISH GRADE OR
HIGHER TO AVOID INFILTRATI❑N. CAP WITH 6'
VENT GRATE W/AT LEAST 9.1 SQ. IN. OPEN
SURFACE AREA. SECURE WITH STAINLESS
STEEL SCREWS (SEE HSF 1.0 X DRAWING).
ORt
RUN VENT TO DESIRED LOCATION AND COVER
OPENING WITH 4' VENT GRATE. SECURE WITH
STAINLESS STEEL SCREWS, VENT MUST NOT
ALLOW EXCESS MOISTURE BUILDUP OR BACK
PRESSURE.
3, ALL APPURTENANCES TO FAST®
(e.g. SEPTIC TANK, PUMP OUTS, ETC.) MUST
CONFORM TO ALL COUNTRY, STATE,
PROVINCE, AND LOCAL CODES,
4. BLOWER CONTROL SYSTEM BY BI❑-
MICROBICS, INC.
5. COPYRIGHT (C) 2005, BI❑-MICROBICS, INC.
6. MUST INCREASE TANK SIZE BY 207 IF
MINIMUM OF 10 INCHES IS USED BETWEEN
THE UNIT AND THE BASE OF TANK.
CONSULT FACTORY FOR APPROVAL.
7. THE PRIMARY COMPARTMENT MAY BE A
SEPARATE TANK.
8. NO MORE THAN 4 FT OF FILLS MAY BE PLAC
PLACED OVER FAST LID. UNIT MAY STAND
INSIDE TANK. SEE DWG HSF 1.0 X & F AND
REFER TO INSTALLATION MANUAL FOR
MORE DETAILS.
9.THE INFLUENT PIPE TEE SHALL BE FITTED
WITH A PIPE CAP, OR THE BAFFLE THAT
SEPARATES THE TVEI ZONES NEEDS TO
EXTEND ALL THE VAY TO THE TOP OF THE
CONCRETE TANK. IF THE PIPE CAP OPTI❑N
IS CHOSEN, THE BAFFLE MUST EXTEND
PAST THE WATER LEVEL AT LEAST THREE
INCHES AS SHOWN IN THE DRAWING.
VnEREsr ff TIMMI LUQCAL I'MM SS. ALL PRImUCTS ARE SUBJECT M DESIGN
R MATERIAL awix vm4xrr wnm
1.0 L
0. - rby BMI
REVISIONS
NO. DATE DESCRIPTION
1. 5/9/06 B.O.H. EDITS
2. 5/19/0 ADD I/A
3 8/04/06 PRESSURE DOSE
GENERAL NOTES:
1. THE CONTRACTOR IS TO COORDINATE
THE SEPTIC TANK REQUIREMENTS BETWEEN
THE LOCAL 'FAST' REPRESENTATIVE
(JOHN ROWLAND (508) 771-5570) AND
THE TANK MANUFACTURER PRIOR TO
ANY SEPTIC COMPONENT INSTALLATION.
D."D r.
CRISPIN
CML
No. 32112
.•oma _
BSC GROUP
657 Main Street, (RT. 28) Unit 6
W. Yarmouth Massachusetts
02673
508 778 8919
PROJECT TITLE:
DESIGN FOR
SEWAGE DISPOSAL
SYSTEM REPAIR
#53
NEPTUNE LANE
SOUTH YARMOUTH
MASSACHUSETTS
PREPARED FOR:
MIKHAIL YAKHKIND, TRUSTEE
NEPTUNE NOMINEE TRUST
2 THOMPSON STREET
WAYLAND
MA 01778
(SSC (508) 778-8919
DATE: APRIL 24, 2006
COMP. DESIGN: K. HEALY
CHECK: M. DIBB
DRAWN: K. HEALY
FiELD: D. GAZZOLO / J. McCAR^N
FILE NO. 6172-SEP.DIHG
DWG NO. 4"57-03JOB NO. 4- SHEET 3 OF 3