HomeMy WebLinkAbout53 Neptune Lane Sewage Disposal System Repair Design 4Specif ications For HighStrengthF-AST 1,0 1. GENERAL The contractor shall furnish and Install (1) HlghStrengthFAST 1.0 treatment system as manufactured by Bio-Microbics, Inc. The treatment system shall be complete with all needed equipment as shown on the drawings and specified herein. The principal Items of equipment shall Include FAST System Insert, Insert lid (or teg extensions If that option Is chosen), blower assembly, blower controls and alarms. The HlghStrengthFAST 1.0 unit shall be situated within a 500 gallon minimum compartment tank, as shown on the plans, or in a 1250 gallon one compartment tank. Tank(s) must conform to local, state, and all other applicable codes. The contractor shalt provide coordination between the FAST system and tank supplier with regard to fabrication of the tank, Installation of the FAST unit and delivery to the job site. 2. OPERATING CONDTIONS The HlghStrengthFAST 1.0 treatment system shall be capable of treating the wastewater from all facilities producing appropriate waste to develop and sustain a viable biomass. Waste containing inhibitory substances is not recommended for treatment in the FAST system. Consult factory for proper sizing and usage. 3. MEDIA The FAST media shall be manufactured of rigid PVC, polyethylene or polypropylene and it shall be supported by the polyethylene Insert. The media shall be fixed in position and contain no moving or wearing parts and shall not corrode. The media shall be designed and Installed to ensure that sloughed solids Immediately descend through the media to the bottom of the septic tank. 4. BLOWER The HlghStrengthFAST 1.0 unit shall come equipped with a regenerative type blower capable of delivering 32-36 CFM. The blower assembly shall Include an Inlet fitter with metal fitter element. 2' (5cm) 1.25' 9.25' 9' _ (3.2cm) r-(6.5cm) 1 (22.9cm) 17' (43.2cm) (22.9.9cm) 1.25' <3.2cm) TYP 22.75' (57.8cm) BLOWER H❑USING BASE DIMENSIONS (SECTION A -A) Aj_ 4' (10.2cm) IV .ai,- NFOI;JV4011111i N­ UA • 6' (15.2cm)-� VENTS W/FAST LID 14' (35.6cm> 5' (12.7cm) N BLOWER HOUSING DIMENSIONS Wastewater Treatment System 5. REMOTE MOUNTED BLOWER The blower may be mounted remote with no more than 100 ft (30.5 M) of piping and no more than four elbows, from the HlghStrengthFAST unit on a contractor supplied concrete base. The blower must not set in standing water and Its elevation must be higher than the normal flood level. A two-piece, rectangular housing shall be provided with tamper -proof screws. The discharge air line from the blower to the HlghStrengthFAST shall be provided and Installed by the contractor. 6. ELECTRICAL The electrical source should be within 150 feet of the blower. Consult local code for longer wiring distances. All wiring must conform to code. The Input power required for the blower is 115/230 Volts, Single Phase, 60/50 Hertz, 3.8/1.9 Full Load Amps, minimum wire size Is 14 A.W.G. (Locked Rotor Amps are 18.6/9.3). All conduit and wiring between the electrical control panel (optional), the power supply, and the blower shall be furnished and Installed by the contractor. 7. ALARMS The alarm system shalt consist of a visual and audible alarm to indicate toss of power to the blower and/or high water level. A manual silence switch is Included. 8. INSTALLATION AND OPERATI❑N INSTRUCTIONS Alt work must be done in accordance with local codes and regulations. Installation of the HlghStrengthFAST 1.0 shall be done in accordance with the written Instructions provided by the manufacturer. No more than four feet of fill may be placed over the FAST lid. Operation manuals shall be furnished which will Include a description of installation, operation, and system maintenance procedures. There shall be a separate manual for the Installer, service provider, and owner, tailored to each. 7.25 (18.acm) 8' (30.5cm) 20.3cm3-I TYP PLAN VIEV Ll LEG EXTENSI❑N SEE NOTE 3. 4. 4.212CRU 40 PVC PVE--*.,� 3.875' cur (9.8cm) NOTES 1. SECURE ORIGINAL 7' X 7' FOOT TO LEG EXTENSION BY PLACING TWO (2) SCREWS IN EACH SIDE OF THE LEG EXTENSION. EIGHT (8) SCREWS PER FOOT ARE INCLUDED AND SHOULD BE USED ON EACH OF THE FOUR (4) CORNER LEG EXTENSIONS. 2. ANCHOR THE LEG EXTENSIONS (4 CORNER LEGS ONLY) TO THE BASE OF THE TANK. PLACE BOLTS AT OPPOSITE CORNERS OF THE LEG EXTENSION BASE, 3. TO ELONGATE FOOT PAST THE PROVIDED 12', CUT THE 3.9' LEG EXTENSION IN THE CENTER INTO TWO SEPARATE PIECES. THEN CUT A SCH 40 PVC PIPE TO THE DESIRED LENGTH AND SLIP THE PIPE OVER THE TOP AND BOTTOM CUT SECTIONS OF THE LEG EXTENSIONS. 4. ATTACH PIPES WITH STAINLESS STEEL SCREWS. 5. VENT TO BE LOCATED ABOVE FINISH GRADE OR HIGHER TO AVOID INFILTRATION. CAP WITH 6' VENT GRATE W/AT LEAST 9.1 SQ. IN. OF OPEN SURFACE AREA. SECURE WITH STAINLESS STEEL SCREWS (SEE HSF 1.0 L DWG). OR RUN VENT TO DESIRED LOCATION AND COVER OPENING WITH 3' VENT GRATE. SECURE WITH STAINLESS STEEL SCREWS. VENT MUST NOT ALLOW EXCESS MOISTURE BUILDUP OR BACK PRESSURE. IN THE INTEREST OF TECHNOLOGICAL PROGRESS, ALL PRODUCTS ARE BIO- MI R BIC 6IHighStrengthFAST®1.0 X JTR o a 1-800-753-FAST(3278) 9. WARRANTY The manufacturer of the HlghStrengthFAST 1.0 treatment system shall warrant for eighteen months from the date of shipment or one year from the date of start-up, whichever occurs first, that the equipment they provide will be free from defects In material and workmanship. In the event a mechanical component falls to perform as specified or is proven defective in service during the warronty period, the manufacturer shalt repair or replace such defective parte (Cost of labor on repair/replacement Is not covered under this warranty. The replacement or repair of those Items normally consumed In service such as air fitter, etc., shalt be considered as part of routine maintenance and upkeep. It is not intended that th manufacturer assume r snnnsin1(tty_ for detects In design. material or workmanship. or delays in delivery. replacement, or otherwise 10. FLOW AND D❑SING Wastewater treatment systems work best when Influent flow Is delivered as consistently as possible. FAST systems have been successfully designed, tested and certified recieving gravity, demand -based Influent flow. When Influent flow Is controlled (either by pump or other means) to the FAST system to help with highly variable flow conditions, then multiple feeding events should be used to help assure even flow, optimum performance, and reliability. IN THE INTEREST OF TECHNOLOGICAL PROGRESS, ALL PRODUCTS ARE SUBJECT TO DESIGN AND/OR MATERIAL CHANGE WITHOUT NOTICE. BIO- MI R�BICS o HighStrengthFAST01.0 S 1-800-753-3278(FAS r- by BMI NOTES I.BLOWER PIPING TO FAST MAY NOT EXCEED 100 FT (2).5m) TOTAL LENGTH AND USE A MAXIMUM Or 4 ELBOWS IN THE PIPING SYSTEM (0 100 FT). FOR DISTANCES GREATER THAN 100 FT --CONSULT FACTORY. BLOWER MUST BE LOCATED ABOVE FLOOD LEVELS. 2. VENT TO BE LOCATED ABOVE FINISH GRADE OR HIGHER TO AVOID INFILTRATI❑N. CAP WITH 6' VENT GRATE W/AT LEAST 9.1 SQ. IN. OPEN SURFACE AREA. SECURE WITH STAINLESS STEEL SCREWS (SEE HSF 1.0 X DRAWING). ORt RUN VENT TO DESIRED LOCATION AND COVER OPENING WITH 4' VENT GRATE. SECURE WITH STAINLESS STEEL SCREWS, VENT MUST NOT ALLOW EXCESS MOISTURE BUILDUP OR BACK PRESSURE. 3, ALL APPURTENANCES TO FAST® (e.g. SEPTIC TANK, PUMP OUTS, ETC.) MUST CONFORM TO ALL COUNTRY, STATE, PROVINCE, AND LOCAL CODES, 4. BLOWER CONTROL SYSTEM BY BI❑- MICROBICS, INC. 5. COPYRIGHT (C) 2005, BI❑-MICROBICS, INC. 6. MUST INCREASE TANK SIZE BY 207 IF MINIMUM OF 10 INCHES IS USED BETWEEN THE UNIT AND THE BASE OF TANK. CONSULT FACTORY FOR APPROVAL. 7. THE PRIMARY COMPARTMENT MAY BE A SEPARATE TANK. 8. NO MORE THAN 4 FT OF FILLS MAY BE PLAC PLACED OVER FAST LID. UNIT MAY STAND INSIDE TANK. SEE DWG HSF 1.0 X & F AND REFER TO INSTALLATION MANUAL FOR MORE DETAILS. 9.THE INFLUENT PIPE TEE SHALL BE FITTED WITH A PIPE CAP, OR THE BAFFLE THAT SEPARATES THE TVEI ZONES NEEDS TO EXTEND ALL THE VAY TO THE TOP OF THE CONCRETE TANK. IF THE PIPE CAP OPTI❑N IS CHOSEN, THE BAFFLE MUST EXTEND PAST THE WATER LEVEL AT LEAST THREE INCHES AS SHOWN IN THE DRAWING. VnEREsr ff TIMMI LUQCAL I'MM SS. ALL PRImUCTS ARE SUBJECT M DESIGN R MATERIAL awix vm4xrr wnm 1.0 L 0. - rby BMI REVISIONS NO. DATE DESCRIPTION 1. 5/9/06 B.O.H. EDITS 2. 5/19/0 ADD I/A 3 8/04/06 PRESSURE DOSE GENERAL NOTES: 1. THE CONTRACTOR IS TO COORDINATE THE SEPTIC TANK REQUIREMENTS BETWEEN THE LOCAL 'FAST' REPRESENTATIVE (JOHN ROWLAND (508) 771-5570) AND THE TANK MANUFACTURER PRIOR TO ANY SEPTIC COMPONENT INSTALLATION. D."D r. CRISPIN CML No. 32112 .•oma _ BSC GROUP 657 Main Street, (RT. 28) Unit 6 W. Yarmouth Massachusetts 02673 508 778 8919 PROJECT TITLE: DESIGN FOR SEWAGE DISPOSAL SYSTEM REPAIR #53 NEPTUNE LANE SOUTH YARMOUTH MASSACHUSETTS PREPARED FOR: MIKHAIL YAKHKIND, TRUSTEE NEPTUNE NOMINEE TRUST 2 THOMPSON STREET WAYLAND MA 01778 (SSC (508) 778-8919 DATE: APRIL 24, 2006 COMP. DESIGN: K. HEALY CHECK: M. DIBB DRAWN: K. HEALY FiELD: D. GAZZOLO / J. McCAR^N FILE NO. 6172-SEP.DIHG DWG NO. 4"57-03JOB NO. 4- SHEET 3 OF 3