HomeMy WebLinkAbout12 Newfield Lane Proposed Septic DesignELEV.
ELEV.=
ELEV. = 89_00
SLEVEL
VV ELEV. 87.30 6" UMP
OA ELEV. 9-13
BAFFLE DISTRIBUTION
ELEV. e
BOX ELM_J
(TO BE PLACED ON FIRM BASE) TO BE WATER TESTED
1500 GALLON IF MORE THAN ONE OUTLET
SEPTIC TANK 3/4-
BE PLACED ON FIRM BASE)
3/4' TO 1 1/2' CLEAN
DOUBLE WASHED STONE
FREE OF FINES & SILT
SEWAGE DISPOSAL SYSTEM PROFILE
NOT TO SCALE
O'Otl ELEV. = _88,17
B HIGH CAPACITY INFILTRATORS WITH
STONE IN AN
/1' X 48' X 10' TRENCH FORMATION
i
•17
WELL N A
- 20 FT. MINIMUM FROM CELLAR
CLEAN SAND
TOP OF FOUNDATION
ELEV. = 1�•�
10 FT, MINIMUM
10 FT. MINIMUM FROM SLAB OR CRAWL SPACE
LOAMY SANDt0YR3/2
ADJUST
(ASSUMED)
CONCRETE
COVERS
4' SCHEDULE 40 PVC PIPE
LOAM AND SEED
B
LOAMY SAND
10YR5/6
MIN. PITCH 1/8" PER FT.
2" LAYER OF
18-32
x 89.1
COARSE SAND
10YR6/8
1/8' TO 1/2"
GRAVEL
9.00
C2
MEDIUM SAND
90.50 MAX. WASHED STONE VENT
Ed.25 MIN. NOT REQUIRED
4" CAST IRON PIPE
REV.
SLAB ELEV. 92.5:
--
(OR EQUAL) MINIMUM
PITCH 1/4" PER FT.
E
z 1 CU. FT. OF
CONCRETE
ANCHOR
87.50
FLOW LINE
X
ELEV.
ELEV.=
ELEV. = 89_00
SLEVEL
VV ELEV. 87.30 6" UMP
OA ELEV. 9-13
BAFFLE DISTRIBUTION
ELEV. e
BOX ELM_J
(TO BE PLACED ON FIRM BASE) TO BE WATER TESTED
1500 GALLON IF MORE THAN ONE OUTLET
SEPTIC TANK 3/4-
BE PLACED ON FIRM BASE)
3/4' TO 1 1/2' CLEAN
DOUBLE WASHED STONE
FREE OF FINES & SILT
SEWAGE DISPOSAL SYSTEM PROFILE
NOT TO SCALE
O'Otl ELEV. = _88,17
B HIGH CAPACITY INFILTRATORS WITH
STONE IN AN
/1' X 48' X 10' TRENCH FORMATION
i
•17
WELL N A
SOIL ABSORPTION
MOTT.
ZONE
SYSTEM (SAS)
INDEX
LOAMY SANDt0YR3/2
ADJUST
USGS PROBABLE WATER TABLE ELEV. - _
OBSERVED WATER TABLE ( / / ) ELEV. =
BOTTOM OF TEST HOLE ELEV. =
/ : b . 5 R
ODMS NC
_. 94
95 \ X
LOT 7 X 9�,
13,286 SO. FTS \
a A00,A NFa 97.2
r? vx�lJ
J. V
Chu
x
/ x 98-5 /
X 9
tea. j o� x 9 E.. 4
93.6 / 01.2
X
AGO I X 10 2. i
a-
7
X 02 9 X
6 \ \Zc tuZ2
I
LEGEND:
EXISTING SPOT ELEVATION 00„0
EXISTING CONTOUR----00----
FINAL SPOT ELEVATION
FINAL CONTOUR
SOIL TEST LOCATION IS
UTILITY POLE -_-
TOWN WATER -WSW
CATCH BASIN l®j
GAS LINE
CLEAN OUT
CESSPOOL C.P. Q
SOIL TEST
DATE OF SOIL TEST QCT 4. 2001 _�
SOIL TEST DONE BY $!1'EEISFR ECLf:1CIEE[31d.G
WITNESSED BY _ VON HOGS
OBSERVATION HOLE 1 ELEV.= 90.00
PERCOLATION RATE <-_ MIN./INCH AT 65 INCHES
DEPTH
X 'E6`\
TEXTURE
COLOR
MOTT.
OTHER
0-4
Ap
LOAMY SANDt0YR3/2
NO
ROOTS
4-18
B
LOAMY SAND
10YR5/6
20% COBBLES
18-32
x 89.1
COARSE SAND
10YR6/8
GRAVEL
32-130
C2
MEDIUM SAND
2.5Y7/4
REV.
X
X
SOIL
\
1
TEST
v
v d"
X
-
v
\�.CS
OX
1500 GALLON
9 ��
SEPTIC TANK
p
/ : b . 5 R
ODMS NC
_. 94
95 \ X
LOT 7 X 9�,
13,286 SO. FTS \
a A00,A NFa 97.2
r? vx�lJ
J. V
Chu
x
/ x 98-5 /
X 9
tea. j o� x 9 E.. 4
93.6 / 01.2
X
AGO I X 10 2. i
a-
7
X 02 9 X
6 \ \Zc tuZ2
I
LEGEND:
EXISTING SPOT ELEVATION 00„0
EXISTING CONTOUR----00----
FINAL SPOT ELEVATION
FINAL CONTOUR
SOIL TEST LOCATION IS
UTILITY POLE -_-
TOWN WATER -WSW
CATCH BASIN l®j
GAS LINE
CLEAN OUT
CESSPOOL C.P. Q
SOIL TEST
DATE OF SOIL TEST QCT 4. 2001 _�
SOIL TEST DONE BY $!1'EEISFR ECLf:1CIEE[31d.G
WITNESSED BY _ VON HOGS
OBSERVATION HOLE 1 ELEV.= 90.00
PERCOLATION RATE <-_ MIN./INCH AT 65 INCHES
DEPTH
HORIZ
TEXTURE
COLOR
MOTT.
OTHER
0-4
Ap
LOAMY SANDt0YR3/2
NO
ROOTS
4-18
B
LOAMY SAND
10YR5/6
20% COBBLES
18-32
Cl
COARSE SAND
10YR6/8
GRAVEL
32-130
C2
MEDIUM SAND
2.5Y7/4
REV.
NO WATER ENCOUNTERED AT 120' ELEV. - _moll
DESIGN CALCULATIONS 4
NUMBER OF BEDROOMS
GARBAGE DISPOSAL UNIT _ NO
TOTAL ESTIMATED FLOW _
REQUIRED SEC TANK CAPIYBR) -0_ GAL./DAY
150
ACTUAL SIZE OF SEPTIC TANK 0 GAL
SOIL CLASSIFICATION _I_
DESIGN PERCOLATION RATE Ste- MIN./IN.
EFFLUENT LOADING RATE Q14- GAL/DAY/S.F.
LEACHING AREA _026A33 SQ. FT.
(11X48)+(59X2X10/12)
LEACHING CAPACITY (AREA X RATE) -443,4$ GAL/DAY
828.33 X 0.74
RESERVE LEACHING CAPACITY 44.3.4$ GAL./DAY
NOTES:
1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P.
TITLE 5 AND THE TOWN OF __YAWQ0L_ RULES AND
REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE.
2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO
WITHIN 6' OF FINISHED GRADE.
3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF
WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN
10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE
USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS.
4. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE SHALL
BE MORTARED IN PLACE.
5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH
DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO
OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY.
6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR
IS TO CALL "DIG -SAFE' AT 1-886-344-7233 AT LEAST 72 HOURS
PRIOR TO COMMENCING WORK ON SITE.
7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS
SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION
IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER
IMMEDIATELY.
8. PARCEL IS IN FLOOD ZONE _ O
3. LOT IS SHOWN ON ASSESSORS MAP 105 AS PARCEL _ 21
10. EXISTING CESSPOOLS ARE TO BE PUMPED AND REMOVED.
EY1N OF Q
DUMAS
No 619QAPPROVED: BOARD OF HEALTH
0
o a�
ITAM
DATE
AGENT
LOCUS
2
ROUTE 6
0
PROPOSED SEPTIC DESIGN
FOR
DEAN TALLMAN
G
PROJECT LOCATION IDT
LN.
12 NETNM \T JV.,l Yi OU"IR 11ASS
SV= ENGLM1TEMWG
235 GREAT WESTERN ROAD
508- P. 0. BOX 713
398-3922 SOUTH DENNIS, MASS. 02660
DAA MAY 6, 2002
SCALE 1' = 20'
REV. AUG. 19, 2003
JOB NQ. 5248-00
SHEET 1 OF 1
w nnnn cuicrxco ru CiuccDu
LOCATION MAP
REV.