HomeMy WebLinkAbout25 Nicholas Drive PlansTYPICAL LVL/GLULAM BOLTING/NAILING MULTI 1 3/4" BEAMS 2 PIECES 3 PIECES 4 PIECES 2 PIECES 2" 2 ROWS OF IGD NAILS • 12" O.C. 2 ROWS OF 1/2" DIAM BOLTS • 12" O.C. J-4' 2 ROWS OF 1/2" DIAM BOLTS • 12" O.C. ilw MULTI 3 1/2" BEAMS 4' 2 ROWS OF 1/2" DIAM BOLTS • 12. O.C. BASEMENT NOTES: I 1 I EO j OC) -- a Em : O zlu oo I O Uiv c WN I On F- I I 1 I ' I I I O I 1 36" DIAM. CORRUGATED n GALVANIZED STEEL AREAWAY W/ GRAVEL BED, TYPICAL. I 'I I 1 I m I V A N 18'-O" 12 W/EXISTING 8'-1" 8'-0" 8'-1" - - -- - - - - - --- ---- - r ' I ' . . _ . —. — . _ . _ . — — I 382x10 PT GIRT OUTLINE OF DECK ABOVE 10" DIAMETER SONO -TUB_ ON BIGFOOT FOOTING. TTP. I 2XIO ° 14" O.C. P T FRArr —moi ------------------------- A -------- d"----------------- --------------------------------- -----------------------— --------------------- 1 I 1 O Jr DRILL It GROUT a5 BARS I ° 12" O.C. VERT IN TO n EXISTING FOUNDATION WALL oU TO TIE IN TO NEW WALL, TYP DOUBLE JOISTS UNDER i i tL - SLAB ELEVATION IN -- PORTION OF BASEMENT F-' n TO BE 12" HIGHER THAN ALL PARALLEL PARTITIONS m FULL BASEMENT TO MAINTAIN SEPTIC SETBACK. i \ EL. NOT TO GO BELOW 15.2' I � I I 1 1 1 I I 1 I I —BP O --;--------BP ---- ----ILL 30I 3/4rX4 1/2" LVL GIRT ii ' O , I I r I I I I I I I I --------------------- - - - - - - - - - --- r ---------------- T ---__________—_ LINE OF ELEVATED SLAB SEPARATING FULL BASEMENT FROM WE SHORTENED SHORTENED BASEMENT I UNFINISHED " Jr STOf�AGE I I I N O DOUBLE JOISTS UNDER i - n ALL PARALLEL PARTITIONS �U CONTRACTOR SHALL ENSURE I ,I ' QL ' STRUCTURAL INTEGRITY OF - EXISTING WALL AND TAKE I t -d CARE NOT TO UNDERMINE EXISTING FOOTING. I ° REMOVE EXISTING WINDOW - i DRILL t GROUT Its BARS 1 ° 12" O.C. VERT IN TO I' EXISTING FOUNDATION WALL I TO TIE IN TO NEW WALL, TYP. r I_______________________ ----------------------- --------------------------------------------------------------- " Jr 1 I I I N I i I I. MAIN FOUNDATION WALLS TO BE 8" POURED CONC. W/ 2°u5 TOP t BOTTOM BARS, REST FOUNDATION ON 10"X20" STRIP FOOTING. PROVIDE 38It5 HORIZ. BARS CONTINUOUS IN STRIP FOOTING W/ KEYWAY. PROVIDE Its VERT. DOWELS ° 24" O.C. HORIZ. EXTENDED V—L" MIN. ABOVE TOP OF FOOTING. PROVIDE 5/8"X12" ANCHOR BOLTS ° 4'-0" O.C. MAX. 2. ALL STRUCTURAL STEEL COLUMNS TO BE 3 1/2" CONC. FILLED STEEL COLUMNS TO EXTEND TO FOOTING BELOW. FOOTINGS TO BE 34'XS4"XI2" SQUARE CONCRETE W/ 3945 BARS EACH WAY 3. DOUBLE FLOOR JOISTS UNDER ALL PARALLEL PARTITIONS. 4. DUST CAP TO BE 4" POURED CONC. ON COMPACTED FILL. CUT JOINTS ALONG WALLS AND BEAM COLUMN LINES. S. CONTRACTOR TO PROVIDE BASEMENT VENTILATION AS REQUIRED BY CODE (WINDOWS OR MECHANICAL) G. CONTRACTOR SHALL INSURE THAT ALL FOUNDATION WALLS MAINTAIN 4'-0" MINIMUM COVER. 1. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. ANY MISSU INCORRECT. OR QUESTIONABLE DIMENSIONS NOT BROUGHT TO THE ATTENT OF THE DESIGNER BECOME THE RESPONSIBILITY OF THE CONTRACTOR. I3 TYPICAL NOTES: STRUCTIRAL ENGINEER/DESIGNER TO PERFORM FRAMING INSPSECTION WHEN FRAMING 15 COMPLETE AND PRIOR TO ENCLOSURE BY INTERIOR WALL PLASTER BOARD/FINISH. CONTRACTOR SHALL SCHEDULE AND PROTECT FORM WEATHER ALL EXISTING HOUSE COMPONENTS AND INTERIORS DURING CONSTRUCTION AND C04STRUCT TEMPORARY STRUCTURES/ENCLOSURES AS MAY BE NECESSARY TO INSURE SUCH PROTECTION. CONTRACTOR SHALL SITE INSPECT ALL EXISTING VS. PROPOSED CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND NOTIFY DESIGNER OF ANY DESCREPANCIES AND/OR CHANGES THAT MAY BE ENCOUNTERED. CONTRACTOR SHALL CONSTRUCT AND MAINTAIN TEMPORARY WALLS/ SHORING ETC. TO MAINTAIN/PROTECT EXISTING HOUSE AND STRUCTURAL INTEGRIPY OF EXISTING HOUSE. CONTRACTOR SHALL SITE INSPECT/VERIFY ALL EXISTING VS, PROPOSED CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND MAKE ADJU5TMENT5 AS NECESSARY TO INSURE COMPLIANCE WITH DESIGN PARAMETERS AS WORK FROGRESSES. INTENT OF DESIGN IS TO ALIGN NEW FIRST FLOOR SPACES W/ EXISTING. CONTRACTOR SHALL ADJUST TOP OF FOUNDATION HEIGHT AS NECESSARY TO ACHIEVE DESIGN INTENT. HATCHED AREAS INDICATE EXISTING CONDITIONS ERTARcHffECTS, INC. 141 MAIN STREET, UNIT C YARMO*PORT, MA 02675 TEL (5O"f79802 FAX (508) 392-5289 CLIENT'.. iM do )I F& DAN CAVANAUGH 25 NICHOLAS DRIVE YARMOUTHPORT, MA CONTRACTOR: HODSDON CONSTRUCTI YARMOUTPORT, MA DATE ISSUED: REVISIONS: DECK 5/21/02 PERMIT SET PROGRE S SET PRICINET PROGR�A SET REGISTRATION SCALE: 0 1 2 4 8 SHEET NO. A�\RCHITECTURAL // \-0.0 FOUNDATION PLAN TOTAL NUMBER OF SHI IN SET: THIS SHEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF WORKING DRAWINGS 8'-0" ---------------------------------- - ----------- ---------------------- . — . _ . _ . — . _ . i 392x10 PT GIRT OUTLINE OF DECK ABOVE 10" DIAMETER SONO-LUBE ON BIGFOOT FOOTING, TYP. it OAA 1 2X10 16. O.C. F/14444/" W/EXISTING TYPICAL LVL/GLULAM BOLTING/NAILING v—. MULTI 13/4" BEAMS ----------------------- ------------------------- O DRILL t GROUT tis BARS 2 IV '^ 1IN O.C. VERT IN TO —�` EO m EXISTING FOUNDATION WALL Ew v i i wU TO TIE IN TO NEW WALL. TYP. u OL, j 3 PIECES 10-41 2 ROWS OF ILD NAILS 12" O.C. 0] i I a0 SLAB ELEVATION IN / PORTION OF BASEMENT TO 8E 12" HIGHER THAN / Wm I I m FULL BASEMENT TO x/ --- -- �o n MAINTAIN SEPTIC SETBACK. � Om - i i \ £L. NOT TO GO BELOW 15.2' F 1 I 1 == cc --- gP---'------i--------BP ---- ----'4 4K 1 3 PIECES D,4" 2 ROWS OF 1/2' DIAM BOLTS 12" O.C. i i 301 3/4,X9 1/2" LVL GIRT I 1 i- 1 I I LINE OF ELEVATED BSEPARATING FULL BASEMENT FROM - 34" DIAM. CORRUGATED i i SHORTENED BASEMENT - n GALVANIZED STEEL 1 I 2' AREAWAY W/ GRAVEL- -- --- -- ABED, -TYPICAL. I I UNFINISHED , STORAGE 4 PIECES 0-4' 2 ROWS OF 1/2' DIAM BOLTS • 12' O.C. 1 1 O DOUBLE JOISTS UNDER ' 1° ALL PARALLEL PARTITIONS n �U CONTRACTOR SHALL ENSURE r IL STRUCTURAL INTEGRITY OF 1 1 EXISTING WALL AND TAKE -► ~® CARE NOT TO UNDERMINE EXISTING FOOTING. MULTI 3 1/2" BEAMS 1 I fV i I ii n 2 i i 6 REMOVE EXISTING WINDOW DRILL t GROUT 05 BARS 1 ' ' 0 12" O.C. VERT IN TO d EXISTING FOUNDATION WALL 2 PIECES 0-4' 2 ROWS OF 1/2' DIAM BOLT5 • 12' O.C. 1 1 TO TIE IN TO NEW WALL. TYP. 1 1 I / L______________________ ________________________ I - - I ---------------------------------------------------- o ' I n I ------ BASEMENT NOTES: I. MAIN FOUNDATION WALLS TO BE 8" POURED CONC. W/ 2005 TOP t BOTTOM BARS. REST FOUNDATION ON I0"X20' STRIP FOOTING. PROVIDE 3005 HORIZ. BARS CONTINUOUS IN STRIP FOOTING W/ KEYWAY. PROVIDE 05 VERT. DOWELS 9 24" O.C. HORIZ. EXTENDED 3'-4" MIN. ABOVE TOP OF FOOTING. PROVIDE 5/8"42" ANCHOR BOLTS 0 4'-0" O.C. MAX. 2. ALL STRUCTURAL STEEL COLUMNS TO BE 3 1/2" CONC. FILLED STEEL COLUMNS TO EXTEND TO FOOTING BELOW, FOOTINGS TO BE 34"X34"X12" SQUARE CONCRETE W/ 30U5 BARS EACH WAY. 3. DOUBLE FLOOR JOISTS UNDER ALL PARALLEL PARTITIONS. 4. DUST CAP TO BE 4" POURED CONC. ON COMPACTED FILL. CUT JOINTS ALONG WALLS AND BEAM COLUMN LINES. 5. CONTRACTOR TO PROVIDE BASEMENT VENTILATION AS REQUIRED BY CODE (WINDOWS OR MECHANICAL) 4. CONTRACTOR SHALL INSURE THAT ALL FOUNDATION WALLS MAINTAIN 4'-0" MINIMUM COVER. 1. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. ANY MISSING. INCORRECT, OR QUESTIONABLE DIMENSIONS NOT BROUGHT TO THE ATTENTION OF THE DESIGNER BECOME THE RESPONSIBILITY OF THE CONTRACTOR. Im TYPICAL NOTES: STRUC-URAL ENGINEER/DESIGNER TO PERFORM FRAMING INSPSECTION WHEN FRAMING IS COMPLETE AND PRIOR TO ENCLOSURE BY INTERIOR WALL PLASTER BOARD/FINISH. CONTR4CTOR SHALL SCHEDULE AND PROTECT FORM WEATHER ALL EXISTING HOUSE COMPONENTS AND INTERIORS DURING CONSTRUCTION AND CONSTRUCT TEMPORARY STRUCTURES/ENCLOSURES AS MAY BE NECESSARY TO INSURE SUCH PROTECTION. CONTR4CTOR SHALL SITE INSPECT ALL EXISTING VS. PROPOSED CONDI110NS PRIOR TO AND DURING CONSTRUCTION AND NOTIFY DESIGNER OF AN' DESCREPANCIES AND/OR CHANGES THAT MAY BE ENCOUNTERED. CONTRACTOR SHALL CONSTRUCT AND MAINTAIN TEMPORARY WALLS/ SHORIW4 ETC. TO MAINTAIN/PROTECT EXISTING HOUSE AND STRUCTURAL INTEGRTY OF EXISTING HOUSE. CONTRACTOR SHALL SITE INSPECT/VERIFY ALL EXISTING VS. PROPOSED COND1110NS PRIOR TO AND DURING CONSTRUCTION AND MAKE ADJUSTMENTS AS NECESSARY TO INSURE COMPLIANCE WITH DESIGN PARAMETERS AS WORK PROGRESSES. INTENT OF DESIGN IS TO ALIGN NEW FIRST FLOOR SPACES W/ EXISTING. CONTRACTOR SHALL ADJUST TOP OF FOUNDATION HEIGHT AS NECESSARY TO ACHIEVE DESIGN INTENT. HATCI-ED AREAS INDICATE EXISTING CONDITIONS. I -- ------------�--------- -- ----- ---------------- v----------------------------------------------- IIV (IIII I I� IIII 10101 11111111 pIIIVII00IIV I� I °uuo1� � uu/ IIII uuo lil�l!II i9I//, Ii1uu�IliiIIV11 I WEIill�luW IIII 0 �I I IIIII III I I I E RTWHrr M, INC. 141 MAIN STREET, UNIT C YARMO&PORT, MA 02675 TEL (50 ,69802 PAX (500) 382-5289 CLIENT: YR do M DAN CAVANAUGH 25 NICHOLAS DRIVE YARMOUTHPORT, MA CONTRACTOR: HODSDON CONSTRUCTION YARMOUTPORT, MA DATE ISSUED: REVISIONS: DECK 5/21/02 PERMIT SET PROGR ', S SET PRICIN ET PROGR�S�; SET REGISTRATION SCALE: 1/4"-1'-0- 0 1 2 4 8 SHEET NO. ARCHITECTURAL A-O"O FOUNDATION PLAN TOTAL NUMBER OF SHI IN SET: THIS SHEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF WORKING DRAWINGS z TYPICAL LVL/GLULAM BOLTING/NAILING MULTI 1 3/4" BEAMS Y 2 PIECES D-4' 2 ROWS OF IGD NAILS 12" O.C. 2" 3 PIECES 0-4' 2 ROWS OF 1/2' DIAM BOLTS • 12" O.C. 2' 4 PIECES 2 PIECES 2' )-4' 2 ROWS OF 1/2' DIAM BOLTS • 12" O.C. Y MULTI 3 1/2" BEAMS .4' 2 ROWS OF 1/2' DIAM BOLTS • 12' O.C. BASEMENT NOTES: m I V O I 34" DIAM. CORRtGATED STEEL - AREAWAY W/DG AVEL BED. TYPICAL- C4 YPICAL r 1. MAIN FOUNDATION WALL5 TO BE 8" POURED CONC. W/ 2845 TOP It BOTTOM BARS. REST FOUNDATION ON 10"X20" STRIP FOOTING. PROVIDE 3845 HORIZ. BARS CONTINUOUS IN STRIP FOOTING W/ KEYWAY. PROVIDE 05 VERT. DOWELS a 24" O.C. HORIZ. EXTENDED V-0 MIN. ABOVE TOP OF FOOTING. PROVIDE 5/8"XI2" ANCHOR BOLTS 8 4'-0" O.C. MAX. 2. ALL STRUCTURAL STEEL COLUMNS TO BE 3 1/2" CONC. FILLED STEEL COLUMNS TO EXTEND TO FOOTING BELOW. FOOTINGS TO BE 36"X36"XI2" SQUARE CONCRETE W/ 3845 BARS EACH WAY. 3. DOUBLE FLOOR JOISTS UNDER ALL PARALLEL PARTITIONS. 4. DUST CAP TO BE 4" POURED CONC. ON COMPACTED FILL. CUT JOINTS ALONG WALLS AND BEAM CJLUMN LINES. S. CONTRACTOR TO PROVIDE BASEMENT VENTILATION AS REQUIRED BY CODE (WINDOWS OR MECHANICAL) 4. CONTRACTOR SHALL INSURE THAT ALL FOUNDATION WALLS MAINTAIN 4'-0" MINIMUM COVER. 1. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. ANY MISSING, INCORRECT. OR QUESTIONABLE DIMENSIONS NOT BROUGHT TO THE ATTENTION OF THE DESIGNER BECOME THE RESPONSIBILITY OF THE CONTRACTOR. 8'-0" ---------- ------ ---------- 4 ----------------------------------- -, I .L._._ _._._ .L._._. -. -. -.Y - 1 382x10 PT GIRT OUTLINE OF DECK ABOVE I I 10' DIAMETER SONO TUBE 18'-O" ON 51GFOOT FOOTING, TYP. I O 2X10 a 14" D.C. F IP A m;r= I P I O A n A.5 I I I I ALIGN W/EXISTING- 0 TYFICAL DOTES: STRUCTURAL ENGINEER/DESIGNER TO PERFORM FRAMING INSP5ECTION WHEN FRAMING IS COMPLETE AND PRIOR TO ENCLOSURE BY INTERIOR WALL PLASTER BOARD/FINISH. CONTRACTOR SHALL SCHEDULE AND PROTECT FORM WEATHER ALL EXISTING HOUSE COMPONENTS AND INTERIORS DURING CONSTRUCTION AND CONSTRUCT TEMPORARY STRUCTURES/ENCLOSURES AS MAY BE NECESSARY TO INSURE SUCH PROTECTION. CONTRACTOR SHALL SITE INSPECT ALL EXISTING VS. PROPOSED CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND NOTIFY DESIGNER OF ANY CESCREPANCIES AND/OR CHANGES THAT MAY BE ENCOUNTERED. CONTRACTOR SHALL CONSTRUCT AND MAINTAIN TEMPORARY WALLS/ SHORING ETC. TO MAINTAIN/PROTECT EXISTING HOUSE AND STRUCTURAL INTEGRITY OF EXISTING HOUSE. CONTRACTOR SHALL SITE INSPECT/VERIFY ALL EXISTING VS. PROPOSED CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND MAKE ADJUSTMENTS AS NECES5ARY TO INSURE COMPLIANCE WITH DESIGN PARAMETERS AS WORK PROGRESSES. INTENT OF DESIGN IS TO ALIGN NEW FIRST FLOOR SPACES W/ EXISTING. CONTRACTOR SHALL ADJUST TOP OF FOUNDATION HEIGHT AS NECESSARY TO ACHIEVE DESIGN INTENT. HATCHED AREAS INDICATE EXISTING CONDITIONS. ERTAW=73, INC. 141 MAIN STREET, UNIT C YARMO&PORT, MA 02675 TEL (50"69802 FAX (508) 382-5289 CLIENT: MR do 10. DAN CAVANAUGH 25 NICHOLAS DRIVE YARMOUTHPORT, MA CONTRACTOR: HODSDON CONSTRUCT] YARMOUTPORT, MA DATE ISSUED: REVISIONS: DECK 5/21/02 PERMIT SET PROGRExSS SET PRICIN ET PROGR�A SET REGISTRATION SCALE- 1le-f-0' eu. 0 1 2 4 8 SHEET NO. ARCHITECTURAL A-0,0 FOUNDATION PLAN TOTAL NUMBER OF SHEETS IN SET - THIS SHEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF WORKING DRAWINGS I F -------------- ------- - -----------------------`--------- --------------- r--- ------- - ---------------- - I ---------------------------------- — ' 1 --------- --------------------- ---- -------------- I I ' I I I I 1 I I DRILL t GROUT 4S BARS 12" O.C. VERT IN TO c'4 EXISTING FOUNDATION WALL aa'O TO TIE IN TO NEW WALL. TYP. i I I a0 SLAB ELEVATION IN PORTION OF BASEMENT ~J TO BE 12" HIGHER THAN I m FULL BASEMENT TO MAINTAIN SEPTIC SETBACK. I r � EL. NOT TO GO BELOW 15.2' / i I - -------- r , I , I i 0 BP 381 3/4X9 1/2" LViL GIRT I r " 1 LINE OF ELEVATED SLAB SEPARATING FULL BASEMENT FROM ' I I SHORTENED BASEMENT ' I r r I I 1 I I UNFINISHED STORAGE I r— II I i O DOUBLE JOISTS UNDER I ALL PARALLEL PARTITIONS N CONTRACTOR SHALL ENSURE I I 0-6 STRUCTURAL INTEGRITY OF I EXISTING WALL AND TAKE Hv CARE NOT TO UNDERMINE I I I EXISTING FOOTING. I , I aLII , REMOVE EXISTING WINDOW , �I " I I I DRILL It GROUT 45 BARS I I 8 12' O.C. VERT IN TO I EXISTING FOUNDATION WALL I I TO TIE IN TO NEW WALL, TYP. I II----------------------- ------------------------ I I I I ' ' I L________________________________________________________________________________ 0 TYFICAL DOTES: STRUCTURAL ENGINEER/DESIGNER TO PERFORM FRAMING INSP5ECTION WHEN FRAMING IS COMPLETE AND PRIOR TO ENCLOSURE BY INTERIOR WALL PLASTER BOARD/FINISH. CONTRACTOR SHALL SCHEDULE AND PROTECT FORM WEATHER ALL EXISTING HOUSE COMPONENTS AND INTERIORS DURING CONSTRUCTION AND CONSTRUCT TEMPORARY STRUCTURES/ENCLOSURES AS MAY BE NECESSARY TO INSURE SUCH PROTECTION. CONTRACTOR SHALL SITE INSPECT ALL EXISTING VS. PROPOSED CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND NOTIFY DESIGNER OF ANY CESCREPANCIES AND/OR CHANGES THAT MAY BE ENCOUNTERED. CONTRACTOR SHALL CONSTRUCT AND MAINTAIN TEMPORARY WALLS/ SHORING ETC. TO MAINTAIN/PROTECT EXISTING HOUSE AND STRUCTURAL INTEGRITY OF EXISTING HOUSE. CONTRACTOR SHALL SITE INSPECT/VERIFY ALL EXISTING VS. PROPOSED CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND MAKE ADJUSTMENTS AS NECES5ARY TO INSURE COMPLIANCE WITH DESIGN PARAMETERS AS WORK PROGRESSES. INTENT OF DESIGN IS TO ALIGN NEW FIRST FLOOR SPACES W/ EXISTING. CONTRACTOR SHALL ADJUST TOP OF FOUNDATION HEIGHT AS NECESSARY TO ACHIEVE DESIGN INTENT. HATCHED AREAS INDICATE EXISTING CONDITIONS. ERTAW=73, INC. 141 MAIN STREET, UNIT C YARMO&PORT, MA 02675 TEL (50"69802 FAX (508) 382-5289 CLIENT: MR do 10. DAN CAVANAUGH 25 NICHOLAS DRIVE YARMOUTHPORT, MA CONTRACTOR: HODSDON CONSTRUCT] YARMOUTPORT, MA DATE ISSUED: REVISIONS: DECK 5/21/02 PERMIT SET PROGRExSS SET PRICIN ET PROGR�A SET REGISTRATION SCALE- 1le-f-0' eu. 0 1 2 4 8 SHEET NO. ARCHITECTURAL A-0,0 FOUNDATION PLAN TOTAL NUMBER OF SHEETS IN SET - THIS SHEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF WORKING DRAWINGS I;H 1 i 4 ET:7 IIB,N 21 h?; I� l �I RECENED SECOND FLOOR FIRST FLOOR FRONT ELEVATION ALL EXTERIOR SIDING. TRIM DETAILS. AND COLORS TO MATCH EXISTING. ERTAMWECTS, VC. 141 MAIN STREET, UNIT C YARMOUTHPORT, YA .02675 m (sm) 3z-spr VAX (gym) 3"-5m wJVOUTH MWIN 7 0KH, CLIENT: Ifit & M. D01 CAMNAUGH 25 NICHOLAS DRIVE YARMOUTHPORT, MA NO FLOOR /1 CONTRACTOR HO' 0€I CO MMON YARMOUTPORT, MA ?ST.FLOOR DATE ISSUED: REMSIONS: PERMIT SET PROGRESS SET PRICING SET PROGRESS SET SECOND FLOORjp'a REGISTRATION ' P-. I�'�I�- FIRST FLOO 1 2 4 E SHEET NO. ARMTECTURAL -3.0 ELEVATIONS TOTAL NUMBER 07 SHEETS IN SET: TH'S SHEET INVALID II;�I ESS ACCO`!PAPI)E D BY A WAPLETE SET OF �#°0RKIN5 DI AWNGS SECOND -FLOOR__ ._ FIRST FLOOR.- SECOND FLOOR FIRST FLOOR FFONT ELEVATION ALL EXTERIOR SIDING. TRIM DETAILS. AND COLORS TO MATCH EXISTING. LEFT ELEVATION ALL EXTERIOR SIDING, TRIM DETAILS, AND - COLORS TO MATCI4 EXI57ING. . Ifo 4x.113 141 IfAIN STRE'E'T'; U"SIT C 2 °8",R 21 k' d 14 YARYOUTHPORT, RSA 02675 M (509) 342-£&32 FAX ) 342-5m* RECL-11 EL r-- A" r VA V)j'y1 'jV' CUEIa'T: 25 NICHOIAS DRIVE YAR:HOUTHPORT, VA - -- -- - SECOND FLOOR Lj 1. "! CONTRACTOR: II YARMOUTPORT, MA I _ FIRST FLOOR DATE ISSUED: REVISIONS: — PERMIT SET PROGRESS SET PRICING SET PROGRESS SET - - - - - -- - - - - - SECOND FLOOR REGISTRATION SCALE: 1/40+•1'-C FIRST FLOOR --- --- - - - --- ---- - -- - --- - ---- - - 0 1 2 4 8 SHEET NO. /ARCHITECTURAL A-3.0 ELEVATIONS TOTAL NUMBER OF SHEETS IN ET THIS SKEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF 4'd0!?I{1TSG -E T7 TYPICAL LVL/GLULAM BOLTING/NAILING MULTI 1 3/4" BEAMS 2 PIECES 3 PIECES I PIECES 2 PIECES ICD NAILS n 12' O.C. I/2" DIAM BOLTS 0 12' O.C. 1/2" DIAM BOLTS 9 12' O.C. 1/2" DIAM BOLTS 9 12' O.C. f 1 , CPO ERTARCHI: 141 MAIN STREE'- 1011 111T, M TEL (50¢36gj9802 FAX I 8'-I" LI 8'-O" 81-1" il r--'------------- -------1----'--`---A —---------- ----------------------- � I 1 1 I I ' OUTLINE OF DECK A.50VE 1 I - 10" DIAMETER SONO -TUBE 1 ON BIGFOOT FOOTING, TYP. 1 � 1 I 2X10 0 IC O.C. P.T. FRAME - 1 I , , A1 1 A.5 ALIGN W/EXISTING - - I i I ------------------r----------- ---- -- — ------------------------------ --------------- -'---------- I '------------------------------------------------ - I I I ' O DRILL t GROUT US BARS wa' 1 1 n 0 12" O.C. VERT IN TO , I Fp l i i p EXISTING FOUNDATION WALL i TO TIE IN TO NEW WALL, TYP- a0': I O _ SLAB ELEVATION IN � I p> PORTION OF BASEMENT _ U� i ~ =° TO BE 12" HIGHER THAN / WN I 1 �m FULL BASEMENT TO I tl7r a— MAINTAIN SEPTIC SETBACK. EL. NOT TO GQ BELOW 15.2' 1 I I j t I ---301 3/4.X9 1/2" LVL GIRT A---- LINE OF ELEVATED SLAB SEPARATING / j /% p I I FULL BASEMENT FROM I 1 ' ' SHORTENED BASEMENT 34 DIAM. CORRUGATED L n GVANIZED STEEL '` - - / ' A.EAWAY W/ GRAVEL BED. TYPICAL. i UNFINISHED I a STORAGE 1 i 1 O DOUBLE JOISTS UNDER 1 t ALL PARALLEL PARTITIONS I , I n p I t wo CONTRACTOR SHALL ENSURE (L -p STRUCTURAL INTEGRITY OF q EXISTING WALL AND TAKE N v CARE NOT TO UNDERMINE 1 \W EXISTING FOOTING. / / / I w REMOVE EXISTING WINDOW— co DRILL l GROUT tt5 BARS 0 12" O.C. VERT IN TO ;✓/ /� / 1 EXISTING FOUNDATION WALL- I t I TO TIE IN TO NEW WALL, TYR ' I --------------_________ ___________________,____ /---------------- ----- - ----- --------- ---J I ' I of (V I A U CLIENT: MR k MRS. DAN CAVANAUGH 25 NICHOLAS DRIVE YARMOUTHPORT, MA CONTRACTOR: HODSDON CONSfRUCTI YARMOUTPORT, MA DATE ISSUED: REVISIONS: APR 6 2002 PERMIT SET APR 6 2002 PROGRESS SET PRICING SET PROGR�S% SET REGISTRA SCALE: 1/4"m1'-0' _ 0 1 2 4 S SHEET NO. ARCHITECTURAL 14-0-0 FOUNDATION PLAN TOTAL NUMBER OF SHI IN SET: THIS SHEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF WORKING DRAWINGS TOWN OF YARMOUTH REVIEWED FOR BUILDING AND ZONING CODE CONIPLI- ANCE, ERRORS OR OMMISSIONS DO NOT RELIEVE THE APPLICANT FROM THE RESPONSIBILITY OF 'AS BUILT" COMPLIANCE• DATE; - BASE1"1ENT NOTES: M NOTES: I TYPICAL OTES: BUILDING OFFICIAL STRUCTURAL ENGINEER/DESIGNER TO PERFORM FRAMING INSPSECTION I. MAIN FOUNDATION WALLS TO BE 8" POURED CONC. W/ 25tt5 TOP WHEN FRAMING IS COMPLETE AND PRIOR TO ENCLOSURE BY INTERIOR t BOTTOM BARS. REST FOUNDATION ON 10"X20" STRIP FOOTING. WALL PLASTER BOARD/FINISH. - PROVIDE 30sS HORIZ. BARS CONTINUOUS IN STRIP FOOTING W/ KEYWAY- PROVIDE tt5 VERT. DOWELS 0 24" O.C. HORIZ. EXTENDED 3'-6" MIN. ABOVE TOP OF FOOTING. PROVIDE 5/8"X12" ANCHOR EXISTING HOUSE COMPONENTS AND INTERIORS DURING CONSTRUCTION CONTRACTOR SHALL SCHEDULE AND PROTECT FORM WEATHER ALLFILE ('� 'i �COPT BOLTS a 4'-0" O.C. MAX. AND CONSTRUCT TEMPORARY STRUCTURES/ENCLOSURES AS MAY BE 4 �9 NECESSARY TO INSURE SUCH PROTECTION. 2- ALL STRUCTURAL STEEL COLUMNS TO BE 3 1/2" CONC. FILLED STEEL CONTRACTOR SHALL SITE INSPECT ALL EXISTING VS. PROPOSED - COLUMNS TO EXTEND TO FOOTING BELOW. CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND NOTIFY DESIGNER FOOTINGS TO BE 3CX3V'X12" SQUARE CONCRETE W/ 3005 BARS EACH WAY. OF ANY OESCREPANCIES AND/OR CHANGES THAT MAY BE ENCOUNTERED. 3. DOUBLE FLOOR JOISTS UNDER ALL PARALLEL PARTITIONS. CONTRACTOR SHALL CONSTRUCT AND MAINTAIN TEMPORARY WALLS/ SHORING ETC. TO MAINTAIN/PROTECT EXISTING HOUSE AND STRUCTURAL 4. DUST CAP TO BE 4" POURED CONC. ON COMPACTED FILL, INTEGRITY OF EXISTING HOUSE. CUT JOINTS ALONG WALLS AND BEAM COLUMN LINES. - CONTRACTOR SHALL SITE INSPECT/VERIFY ALL EXISTING VS. PROPOSED 5. CONTRACTOR TO PROVIDE BASEMENT VENTILATION AS CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND MAKE ADJUSTMENTS REQUIRED BY CODE !WINDOWS OR MECHANICAL) AS NECESSARY TO INSURE COMPLIANCE WITH DESIGN PARAMETERS AS WORK PROGRESSES. L. CONTRAC70R SHALL INSURE THAT ALL FOUNDATION WALLS MAINTAIN INTENT OF DESIGN IS TO ALIGN NEW FIRST FLOOR SPACES 4'-0" MINIMUM COVER. W/ EXISTING. CONTRACTOR SHALL ADJUST TOP OF '1. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. ANY MISSING. FOUNDATION HEIGHT AS NECESSARY TO ACHIEVE DESIGN INTENT. INCORRECT. OR QUESTIONABLE DIMENSIONS NOT BROUGHT TO THE ATTENTION HATCHED AREAS INDICATE EXISTING CONDITIONS. OF THE DESIGNER BECOME THE RESPONSIBILITY OF THE CONTRACTOR. U CLIENT: MR k MRS. DAN CAVANAUGH 25 NICHOLAS DRIVE YARMOUTHPORT, MA CONTRACTOR: HODSDON CONSfRUCTI YARMOUTPORT, MA DATE ISSUED: REVISIONS: APR 6 2002 PERMIT SET APR 6 2002 PROGRESS SET PRICING SET PROGR�S% SET REGISTRA SCALE: 1/4"m1'-0' _ 0 1 2 4 S SHEET NO. ARCHITECTURAL 14-0-0 FOUNDATION PLAN TOTAL NUMBER OF SHI IN SET: THIS SHEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF WORKING DRAWINGS • ,/ TOV, G , IN MAIN STREET, UNIT C YARMOUTHPORT, VA 02675 207 r, AR 21 F I MW Cm) w -sect FAx (sm) ars-vee RELI~{v =l) CLIENT. } > DAt CA9A21AUGH �- -- — - ;------- -- - - - -- - --- — ----- .�----- — 25 NICHOLAS DRIVE r ! FIRST FLOOR t --t m YARMOUTHPORT, MA --- SECOND FLOOR -- — --- - - - CONTRACTOR ROD2014 COirS'i?UCT'ION -- -- - - - - - YARMOUTPORT, MA -- - - - -- - - ; FIRST FLOOP. ja .,a, -erase --- erw�eew. DATE ISSUED: REVISIONS: PERMIT SET PROGRESS SET PRICING SET PROGRESS SET _ SECOND FLOOR REGISTRATION SCALE: 1/$-1'-O" 4 ;s SHEET NO. ARCHITECTURAL ELEVATIONS TOTAL NUMBER O)• SHEETS IN 5.;:�AV V� THIS SHEET INVALID UNLESS ACCO"1,^G?'€£D BY A COMPLETE SET O;= WORKING D'R,AWN"GS � I SECOND _FLOOR FIPST FLOOR_ -- REAR ELEVATION ALL EXTEIZIOP S'D'NG, TRIM DETAILS. AND COLCaS TO MACH EXISTING. j Nl.L!'Lt1u7s, J. 701 NAR 21 gi 141 MAIN STREET, (IMT C YARMOUTITTORT, MA 02675 EC i.. I �;9G2-St'7v Pd% om w -52"8 7v CLIENT: 01 Mr., DAN C011R IG 25 NICEOLAS DFJVE YARM'OUTHpon, im SECOND FLOOR --� - - CONTRACTOR: YARMOM PORT, MA -_ _ --- F:P,ST FL00%' " 1, i DATE ISSUED: REVISIONS: PERMIT SET PROGRESS SET PRICING SET PROGRESS SET - — — — — — -- -- — - — -SECOND FLOOR REGISTRATION SCALE; 1/4`-1'-0' FIRST FLOOR- - — -- - - - — - -- — 0 1 2 4 8 SHEET NO. /ARCHITECTURAL A -A4.0 ELEVATIONS TOTAL NULL48ER OF SHEETS IN r-�A03 q'� THIS SHEET 'INVALID _ - - UNLESS ACCOMPANIED BY A COMPLETE SE7 O'. FIRST FLOOR RIGHT ELEVA I ION ALL EXTERIOR SIDING. TRIM DETA!LS, AND COLORS TO MATCH EXISTING. I I Nl.L!'Lt1u7s, J. 701 NAR 21 gi 141 MAIN STREET, (IMT C YARMOUTITTORT, MA 02675 EC i.. I �;9G2-St'7v Pd% om w -52"8 7v CLIENT: 01 Mr., DAN C011R IG 25 NICEOLAS DFJVE YARM'OUTHpon, im SECOND FLOOR --� - - CONTRACTOR: YARMOM PORT, MA -_ _ --- F:P,ST FL00%' " 1, i DATE ISSUED: REVISIONS: PERMIT SET PROGRESS SET PRICING SET PROGRESS SET - — — — — — -- -- — - — -SECOND FLOOR REGISTRATION SCALE; 1/4`-1'-0' FIRST FLOOR- - — -- - - - — - -- — 0 1 2 4 8 SHEET NO. /ARCHITECTURAL A -A4.0 ELEVATIONS TOTAL NULL48ER OF SHEETS IN r-�A03 q'� THIS SHEET 'INVALID _ - - UNLESS ACCOMPANIED BY A COMPLETE SE7 O'. FIRST FLOOR RIGHT ELEVA I ION ALL EXTERIOR SIDING. TRIM DETA!LS, AND COLORS TO MATCH EXISTING. *r v.•..s..+z, "�'���.�',.. , ,. _"Z!`. �'i'SR"9T. ri:..r.-..,ww.,x+�m.ra .vm�.>..�.•.w..•�.,..-.: ,,�`��. V 'fig t 3 p > t tr � t 'fig t � t 2,0 , REF. 4fi%ob"�k t ZONE , Ls AS—BU1 PER SE WILUAM TOP FNDN EL. 82.1' <—% SLOPE) SYSTEM PROFILE ACCESS COVER TO WITHIN 6' OF FIN. GRADE (NOT TO SCALE) /�— ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST ! WITHIN 6' OF FIN, GRADE EXISTING 1500 GALLON SEPTIC TANK (H- 10 ) DEPTH OF FLOW = 4 TEE SIZES - INLET DEPTH = 10 OUTLET DEPTH = 14' FOUNDATION— 77.5' 6' CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) MIN ( 1 % SLOPE) --- SEPTIC TANK 9' 2% SLOPE REQUIRED OVER SYSTEM PIPE LEVEL/ 2' DOUBLE WASHED FIRST 2' D' BOX 2' J 3/4' TO 1 1/2' DOUBLE WASHED STONE 2' LEACHING FACILITY 1 V l u 1 l V LLi a_3 1J l I, 1 Y l.i �NOTE: BASEMENT FLOOR ELEVATION OF PROPOSED ADDITION TO BE ABOVE ELEVATION 75.2' (WHICH IS INVERT INTO LEACHING FACILITY) * APPROX. WATERLINE LOCATION ONLY. CALL WATER DEPT. PRIOR TO EXCAVATION FOR MARK OUT 97-265 75.5' 7.5' ELEV. 68.0' (BOT. TH) TEST HOLE LOGS ENGINEER: LOW AND WELLER WITNESS: P. BRYANTON DATE: 4/25/96 PERC. RATE = < 2 MIN/INCH CLASS SOILS P# ELEV. n• 8010' ASSESSORS MAP 143 PARCEL 1221 ZONING DISTRICT: R-40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF. - 460/100 FLOOD ZONE: C _.a NO WATER 0 SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED 3" DATUM IS APPROXIMATED FROM DENNIS QUAD DESIGNI FLOW: 4 BETIR071MS ( 110 GPD) = 440 GPTI a E/A USE A 440 GPD DESIGN FLOW 9„ LS SEPTIC TANK: 440 GPD ( 2 > = 880 4. B �— 5. LS USE A 1500 GALLON SEPTIC TANK(EXIST) 47" 10YR 5/8 76.1' C 2(40.5 + 9.83) 2 (.74) = 149 7. MS SIDES: r-- 2.5Y 6/8 BOTTOM: 40.5 x 9.83 (.74) = 294 44" PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC, 68.0' ASSESSORS MAP 143 PARCEL 1221 ZONING DISTRICT: R-40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF. - 460/100 FLOOD ZONE: C _.a NO WATER ENCOUNTERED NOTES: SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) i. DATUM IS APPROXIMATED FROM DENNIS QUAD DESIGNI FLOW: 4 BETIR071MS ( 110 GPD) = 440 GPTI a pgl_r. tr*?nI_ 1,iATcR IS EXISTING USE A 440 GPD DESIGN FLOW 3. MINIMUM PIPE PITCH TO BE 1/8' PER FOOT. SEPTIC TANK: 440 GPD ( 2 > = 880 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-10 �— 5. PIPE JOINTS TO BE MADE VATERTIGHT. USE A 1500 GALLON SEPTIC TANK(EXIST) 6, CONSTRUCTION kTATLS TO BE IN ACCORDANCE WITH MASS. LEACHING: ENVIRONMENTAL CODE TITLE V. 2(40.5 + 9.83) 2 (.74) = 149 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE'. SIDES: r-- USED FOR LOT LINE STAKING. BOTTOM: 40.5 x 9.83 (.74) = 294 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC, TOTAL: S99 S.F. 443 GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT USE (6) HIGH CAPACITY INFILTRATORS WITH 3.5' INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. STOt E AT SIDES, 1.5' AT ENDS AND 14" UNDER LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION FoolPROPOSED CONTOUR - — 100 —EXISTING CONTOUR BOARD OF HEALTH APPROVED DATE off 508-362-4541 fn. $08 362-9880 down cape engineering, inc, CIVIL ENGINEERS LAND SURVEYORS 939 main St. yarmouth, ma 02675 TITLE 5 SITE PLAN OF 25 NICHOLAS DRIVE IN THE TOV.,N OF: a { YARMOUTH PORT o JJ PREPARED FOR: DAN CAVANAUGH C = N r— r-- 30 0 30 60 90` .tJ MA SCALE: 1" = 30' DATE: APRIL 18, 2001 REV. MARCH 1, 2002 i ARNE P.E., P.L.S. DATE 01-dto3� AS -BUIL PER SEF WILLIAM; TOP FNDN EL. 82.1' SYSTEM PROFILE r ACCESS COVER TO WITHIN 6' OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST WITHIN 6' OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM l_ I�— EXISTING 1500 GALLON SEPTIC --, TANK (H- 10 ) <—% SLOPE) DEPTH OF FLOW = 4 TEE SIZES, INLET DEPTH = 10' OUTLET DEPTH = 14' FOUNDATION -- 19.4' RUN PIPE LEVEL t7 / -FOR FIRST 2' 8.0'1 GA /I�7. ////j4,� 7 BFL 6' CRUSHED STONE OR'MECHANICAL - COMPACTION. (15.221 121) MIN (-'-/ SLOPE) 2' DOUBLE WASHED TEST HOLE LOGS ENGINEER: LOW AND WELLER 81.0t WITNESS: P. BRYANTON DATE: 4/25/96 78.0PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# 2' :' ELEV. c2i$ c0' 80.0' 75.5 _ 3/4' TO 1 1/2' DOUBLE WASHED STONE 0 3„ ---- SEPTIC TANK 9' D' BOX 2' LEACHING FACILITY 1f A Vll WLn 1-1 ll L 1,.L vJ- NOTE: BASEMENT FLOOR ELEVATION OF PROPOSED ADDITION TO BE ABOVE ELEVATION 75.2' (WHICH IS INVERT INTO LEACHING FACILITY) * APPROX. WATERLINE LOCATION ONLY. CALL WATER DEPT. PRIOR TO EXCAVATION FOR MARK OUT E/A 7.5' 9„ LS B LS ELEV. 68.0' (BOT. TH) 47„ 10YR 5/8 76 i ra C 0 5� p r� MS o Q 2.5Y 6/8 " 144 68.0' NO WATER ENCOUNTERED SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS (110 GPD) = 440 GPD J E A 44C -P : : ETF; FLOW ;EPTIC TANK: 440 GPD ( 2 ) = 880 OSE A 1500 GALLON SEPTIC TANK(EXIST) _EACHING: SIDES: 2(40.5 + 9.83) 2 (.74) = 149 BOTTOM: 40.5 x 9.83 (74) = 294 TOTAL: 599 S.F. 443 GPD USE (6) HIGH CAPACITY INFILTRATORS WITH 3.5' STONE AT SIDES, 1.5' AT ENDS AND 14" UNDER LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 00 PROPOSED CONTOUR 100 — EXISTING CONTOUR BOARD OF HEALTH 'APPROVED DATE off 508-362-4541 fax 508 362-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouth, mot 02675 ASSESSORS MAP 143 PARCEL 122 ZONING DISTRICT: R-40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF, - 460/100 FLOOD ZONE: C NOTES. 1. DATUM IS APPROXIMATED FROM DENNIS QUAD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8' PER F'OOT, 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-10. 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. TITLE 5 SITE PLAN OF 25 NICHOLAS DRIVE IN THE TOWN OF: YARMOUTH PORT PREPARED FOR: DAN CAVANAUGH 30 0 30 60 90 MA SCALE: 1 = 30' DATE: APRIL 18, 2001 REV. MARCH 1, 2002 ARNE P.E., P.L.S. DATE AS -BU PER 51 WILLIAI TOP FNDN EL. 82.1' SYSTEM PROFILE ACCESS COVER TO WITHIN 6 OF FIN. GRADE (NOT TO SCALE) /-- ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST /` WITHIN 6' OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM 81.Ot n� RUN PIPE LEVEL 2' DOUBLE WASHED PEASTON6\ IL�_FOR FIRST 2' EXISTING �- 78.0 GALLON SEPTIC 78,0: TANK (H- 110 ) GAS %7. j' 0 77.5' 0 3.5' AT SIDES BAFFLE 71,67' o000 1.5 AT ENDS (_X SLOPE) 6' CRUSHED STONE OR MECHANICAL 2 5� COMPACTION. (15.221 121) 80 035$ o25`b oa$$ 75.5' DEPTH OF FLOW = '4 LAN $ o TEE SIZES- (� 10' SLOPE) 3/4' TO 1 1/2' DOUBLE WASHED ` TONE INLET DEPTH = - - OUTLET DEPTH = 14' FOUNDATION— — SEPTIC TANK 9' D' BOX 2' LEACHING 7.5' FACILITY lYlunVLAJ ijill YG NOTE: BASEMENT FLOOR ELEVATION OF PROPOSED ADDITION TO BE ABOVE ELEVATION 75.2' (WHICH IS INVERT INTO LEACHING FACILITY) * APPROX. WATERLINE LOCATION ONLY. CALL WATER DEPT. PRIOR TO EXCAVATION FOR MARK OUT 97-265 ELEV. 68.0' (BOT. TH) u7n � o 0 0 NO� - - TEST HOLE LOGS ENGINEER. LOW AND WELLER WITNESS: P. BRYANTON DATE• 4/25/96 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# ELEV. 0' 80.0' 3" 1 D E/A 9., LS B LS 47" 10YR 5/8 76.1- C MS 2.5Y 6/8 144" I 168.0' NOWATERENCOUNTERED SE.OTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS (110 GPD) = 440 GPD U::_ A 440 hr.] DLSIGIJ LOO SLE 'TIC TANK1440 GPD ( 2 ) = 880 U:�_ A 1500 GALLON SEPTIC TANK(EXIST) LEACHING: ' SIDES2(40.5 + 9.83) 2 (.74) = 149 — . 40.5 x 9.83 (.74) = 294 B'.]TTOM: T]TAL• 599 S.F. 443 GPD USE (6) HIGH CAPACITY INFILTRATORS WITH 3.5' SICNE AT SIDES, 1.5' AT ENDS AND 14" UNDER LL E 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION Fol PROPOSED CONTOUR — 100 — EXISTING CONTOUR BOARD OF HEALTH APPROVED DATE off 508-362-4511 fox 508 362-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 rain st. yarmouth, ma 02675 , MA ASSESSORS MAP 143 PARCEL 122 ZONING DISTRICT: R-40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF. — 460/100 FLOOD ZONE: C NOTES 1. DATUM IS APPROXIMATED FROM DENNIS QUAD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8' PEP. rPOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H -1U 5, PIPE JOINTS TO BE MADE WATERTIGHT. 6, CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. TITLE 5 SITE PLAN OF 25 NICHOLAS DRIVE IN THE TOWN OF: YARMOUTH PORT PREPARED FOR: DAN CAVANAUGH 30 0 30 60 90 SCALE: 1" = 30' DATE: APRIL 18, 2001 REV. MARCH 1, 2002 ARNE , P.E., P.L.S. 3�yA -�L - DATE SYSTEM PROFILE TOP FNDN EL. 82.1' (NDT TO STALE) ACCESS COVER TO WITHIN 6 OF FIN. GRADE = ACCESS COVER (WATERTIGHT) TO WITHIN 6' OF FIN. GRADE MINIMUM .75' OF COVER OVER PRECAST / 2% SLOPE REQUIRED OVER SYSTEM s 7 RUN PIPE LEVEL P' DOUBLE WASHED PEASTON6� ttt111111 FOR FIRST 2' EXISTING j,500 GALLON SEPTIC TANK (H- 10 > SLOPE) DEPTH OF FLOW = 4' TEE SIZES , INLET DEPTH = 10 OUTLET DEPTH a 14' FOUNDATION - LOT 20 40,952 s.f. 81.0± 78.0'± GAS /7.5' Q 77.5' BAFFL 77 67 t5 6' CRUSHED STONE OR MECHANICAL 2' COMPACTION. (15.221 (21) 8Q $ MIN( -1-Y SLOPE) 3/4' TO 1 1/2' DOUBLE WASHED S" ONE,/ 2, LEACHING SEPTIC TANK 9' D' BOX FACILITY +87.6 o 0 87 84.4 +85.6 - PAVED + DRIVEWAY @91.18 0.6 0.4 Ory +Ea.S i6 . / +83.9 '9TH GAR CONC.. FNDN. LOT 21 67.0 TEST HOLE LOGS ENGINEER+ LOW AND WELLER WITNESS: P. BRYANTON DATEI 4/25/96 PERC, RATE _ < 2 MIN/INCH CLASS SOILS P# f �' ELEV. p• 80.0' 75.5' 0 3" 7.5' t ELEV. 68.0' (BOT. TH) E/A 91, LS B LS 47" 1OYR 5/8 76.1' C MS 144" 68.0' ASSESSORS MAP 143 PARCLL I« ZONING DISTRICT. R-40 YARD SETBACKS, FRONT = 30' SIDE = 20' REAR = 20' PLAN REF. - 460/100 FLOOD ZONE, C NO WATER ENCOUNTERED N❑TES' SEPTIC DESIGN+ (GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW, 4 BEDROCMS (-GPD) = 440 GPD US A 440 GPD DESIGN FLOW SE)TIC.TANK: 440 GPD ( 2 ) = 880 US: A j500 GALLON SEPTIC TANK(EXIST) LE4CHING: 2(40.5 + 9.83) 2 (.74) = 149 SIDES: '06 40.5 x 9.83 (.74) = 294 BETTOM, 0 TI:TAL:. 599 S,F, 443 GPD % U';E (6) HIGH CAPACITY INFILTRATORS WITH 3.5' 9 - 853 545 F ST( NE AT SIDES, 1.5' AT ENDS AND 14" UNDER 1. DATUM IS APPROXIMATED FROM DENNIS QUAD EXISTING 2. r1UIVll : 'AL 'WATER � - 3. MINIMUM PIPE PITCH TO BE 1/8' PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT, 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7, THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9, COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. TITLE 5 SITE PLAN OF 25 NICHOLAS DRIVE IN THE TOWN OF: YARMOUTH PORT PREPARED FOR: DAN CAVANAUGH 30 0 30 60 90 MA SCALE: 1" = 30' DATE: APRIL 18, 2001 REV. MARCH 1, 2002 >, DATE U 6 e T.O.F. ^� 300 = 82.1 r' 0 0.8 i e 72,0 r 81.5 O ' W ^ r Q O L EAG E� t 85. •• PROP. 12 3 ADDN 2.1 AS -BUILT LOCATION OF SEPTIC SYSTEM AS 8 ss M 100.0. PROPOSED SPOT ELEVATION PER SEPTIC INSPECTION REPORT BY TROY WILLIAMS 546 l �� 100x0 EXISTING SPOT ELEVATION 79'5 0 1 11 _ 00 PROPOSED CONTOUR LOT 19 ,r w N 185.18 -- - 100 - EXISTING CONTOUR NICHOLAS DRIVE BOARD OF HEALTH �NOTE: BASEMENT FLOOR ELEVATION OF PROPOSED ADDITION TO BE ABOVE ELEVATION 75.2' (YMICH IS INVERT INTO LEACHING FACILITY) APPROVED DATE - off 508-362-4541 fox 508 362-9880 down cape engineering, inC. *APPROX. WATERLINE LOCATION ONLY. CALL WATER DEPT. PRIOR TO EXCAVATION FOR CIVIL ENGINEERS MARK OUT LAND SURVEYORS 919 main St. yarmouth, ma 02675 1. DATUM IS APPROXIMATED FROM DENNIS QUAD EXISTING 2. r1UIVll : 'AL 'WATER � - 3. MINIMUM PIPE PITCH TO BE 1/8' PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT, 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7, THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9, COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. TITLE 5 SITE PLAN OF 25 NICHOLAS DRIVE IN THE TOWN OF: YARMOUTH PORT PREPARED FOR: DAN CAVANAUGH 30 0 30 60 90 MA SCALE: 1" = 30' DATE: APRIL 18, 2001 REV. MARCH 1, 2002 >, DATE U AS-BUIL PER SEP WILLIAM TOP FNDN EL. 82.1' C__% SLOPE) SYSTEM PROFILE ACCESS COVER TO WITHIN 6' OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST WITHIN 6' OF FIN. GRADE _ 2% SLOPE RERUIRED OVER SYSTEM EXISTING 1500 GALLON SEPTIC TANK (H- 10 ) DEPTH OF FLOW = 4' TEE SIZES INLET DEPTH OUTLET DEPTH = 14' FOUNDATION— RUN PIPE LEVEL /-FOR FIRST 2' 78.0't I`/ GAS % 77.5' BAFFLE 77.s7'o0� 6' CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) MIN < 1 'L SLOPE) SEPTIC TANK 9' D' BOX 0 2' DOUBLE WASHED 01 nu TEST HOLE LOGS ENGINEER: LOW AND WELLER WITNESS: P. BRYANTON DATE: _ 4/25/96 PERC, RATE _ < 2 MIN/INCH CLASS I SOILS P# .%-.oi'� 000 0' ELEV. 80.0' 75.5' _ 3/4' TO 1 1/2' DOUBLE WASHED STONE"t" 3„ 0 LEACHINS 7.5' FACILI T" i I i v A 1 V L/!1 l_J lJ l b1 Y li NOTE: BASEMENT FLOOR ELEVATION OF PROPOSED ADDITION TO BE ABOVE ELEVATION 75.2' (WHICH IS INVERT INTO LEACHING FACILITY) * APPROX. WATERLINE LOCATION ONLY. CALL WATER DEPT. PRIOR TO EXCAVATION FOR MARK OUT 97-265 ELEV. 68.0' (BOT. TH) E/A 9„ LS B LS 47" 10YR 5/8 76.1' C MS 2.5Y 6/8 144" I 1680' NO WATER ENCGUNTERED SEPTIC DESIGN'- (GARBAGE DISPOSER IS NOT ALLOWED ^W- 4 BLD':pOMS ` 110 GOD) = A40 -PT) USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD ( 2 ) 880 USE A 1500 GALLON SEPTIC TANK(EXIST) LEACHING SIDES: 2(40.5 + 9.83) 2 (.74) = 149 BOTTOM: 40.5 x 9.83 (.74) = 294 TOTAL: 599 S,F, 443 GPA USE (6) HIGH CAPACITY INFILTRATORS WITH 3.5' STONE AT SIDES, 1.5' AT ENDS AND 14" UNDER LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 00 PROPOSED CONTOUR -- 100 —EXISTING CONTOUR BOARD OF HEALTH DATE APPROVED off 500-362-.1591 fnx 500 362-9090 down cape engineering, inc, CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouth, ma 02675 MA ASSESSORS MAP 143 PARCEL 122 ZONING DISTRICT: R-40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF, — 460/100 FLOOD ZONE: C i NATES; 1. DATUM IS APPROXIMATED FROM DENNIS QUAD ev In,IrTo�.a L-�'�TE!? .c EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8' PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-10. 5. PIPE JOINTS ' TO BE MADE WATERTIGHT. 6. CONSTRUCTION DEfP:ILS TO BE IN ACCORDANCE WITH MASS.' ENVIRONMENTAL CODE TITLE V, 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH, 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. i TITLE S SITE PLAN OF 25 NICHOLAS DRIVE IN THE TOWN OF: YARMOUTH PORT PREPARED FOR: DAN CAVANAUGH 30 0 30 60 90: M SCALE: 1„ = 30' DATE: APRIL 18, 2001, REV. MARCH 1, 2002 `T- i� r1 v�W t`A ARNEOJALA St`yH .263 I [ 4 zsa r F3,�� �13C ARNE , P.E., P.L.S. DATE 07 - 04 a AS -BUIL PER SEF WILLIAM: TOP FNDN EL. 82.1' SYSTEM PROFILE ACCESS COVER TO WITHIN 6' OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST 1 WITHIN 6' OF FIN. GRADE •,• EXISTING 1500 GALLON SEPTIC TANK (H- 10 ) SLOPE) DEPTH OF FLOW = 4 TEE SIZES - INLET DEPTH = 10 OUTLET DEPTH = 14' FOUNDATION - 79.4' rlF13R RUN PIPE LEVEL FIRST 2' 7B(Y GAS f77 5' BAFFL 77.s7'��ood 6' CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 121) MIN ( '/. SLOPE) — SEPTIC TANK 9' D' BOX 2% SLOPE REQUIRED OVER 2' DOUBLE WASHED 2' $ oda 3/4' TO 1 1/2' DOUBLE WAtHED STONE 2' A v A V i A kJ JJLl IJ "III l Y li 00 NOTE: BASEMENT FLOOR ELEVATION OF PROPOSED ADDITION TO BE ABOVE ELEVATION 75.2' (WHICH IS INVERT INTO LEACHING FACILITY) * APPROX. WATERLINE LOCATION ONLY. CALL WATER DEPT. PRIOR TO EXCAVATION FO" MARK OUT 6411 ���' ��� .• V :'- 97-265 LEACHING FACILITY 8LOt 75.5' 7.5' i ELEV. 68.0' (80T. TH) O TEST HOLE LOGS ENGINEER: LOW AND WELLER WITNESS: P. BRYANTON DATE: 4/75/96 PERC. RATE _ < 2 MIN/INCH I CLASS SOILS P# ELEV. o' 80.0' 3" [ 7 E/A 9, LS B LS 47" 10YR 5/8 76.1' C MS 2.5Y 6/8 144" L 68_0' NO WATER ENCOUNTERED ;_F_PTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED I ESIGN FLOW: lSEUF 7 MS (__LPD) = 44L GPD USE A 440 GPD DESIGd FLOW SEPTIC TANK: 440 GPD ( 2 ) = 880 USE A 1500 GALLON SEPTIC TANK(EXIST) LEACHING: SIDES: 200.5 + 9.83) 2 (.74) = 149 BOTTOM, 40.5 x 9.83 (.74) = 294 TOTAL: 599 S.F. 443 GPD USE (6) HIGH CAPACITY INFILTRATORS WITH 3.5' STONE AT SIDES, 1.5' AT ENDS AND 14" UNDER LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION F00­1PROPOSED CONTOUR — 100 —EXISTING CONTOUR BOARD OF HEALTH ASSESSORS MAP 143 PARCEL 122 ZONING DISTRICT: R-40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF. — 460/100 FLOOD ZONE: C NOTES: _) 1. DATUM IS APPROXIMATED FROM DENNIS QUAD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8' PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H -t0. 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS, ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING, 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. TITLE 5 SITE PLAN OF 25 NICHOLAS DRIVE IN THE TOWN OF: YARMOUTH PORT PREPARED FOR: DAN CAVANAUGH 30 0 30 60 90 APPROVED DATE , MA SCALE: 1 11 = 30' DATE: APRIL 18, 2001 REV, MARCH 1, 2002 off 508-362-4511 ff iox 508 362-9880 awn cape engineering, inc, tea" °F 4 ora` ARNE CIVIL '1=NGINEERS H.OJALAH LAND SURVEYORS yG 20 04; in st, yarmouth, ma 02675 ! _3�Y�% ARNE '' P.E., T.L.S. DATE