HomeMy WebLinkAbout43 Nickerson Farm Way - Attic Loads_S 1 L-26 M;4 i 0 M ' 8 PR ' 3 1/2" A complete TJ-Xpert framing plan requires the Trus Joist Framer's Pocket Guide See Trus Joist Framer's Pocket Guide for Product Tradeeark Information u 36' HANGER LIST - Simpson Strong -Tie Company, Inc.® Plot ID Qty Product Label Top Nails Face Nails Member Nails Notes H1 1 U410 14-16d 6-10d H2 1 HU410 14-16d 6-10d - Joists By Others CREATED BY Mid -Cape Home Centers PO BOX 1418 465 ROUTE 134 SOUTH DENNIS, MA 02660 5083986071 FAX: 5083984559 n TJ•Xperte ~,W SYMBOL LEGEND Point Load .._._ Line Load Area Load HBO Beam By Others Q Detail Callout Label (See Framer's Pocket Guide) Required Bearing Length in inches (Adequate bearing has been provided if bearing length is not indicated.) LEVEL NOTES File Name: METER RES.12.20.JOB Level Name: ATTIC LOADS Plotted: 12/20/2004 16:04 Design Status: FIRST FLOOR .... 12/20/2004 13:25 SECOND FLOOR ... 12/20/2004 13:25 ATTIC LOADS .... 12/20/2004 13:23 ROOF LOADS ..... 12/20/2004 13:23 NOTE: Level design times indicated above provide assurance for proper level stacking. Design Methodology: ASD Floor Area Loads Vary: 25 to 30psf Live Load and 12 to 12psf Dead Load Maximum Joist Deflection: L/480 Live Load L/240 Total Load TJ -Pro Rating Information: Weighted Average: NA Lowest Rating: NA Highest Rating: NA Glued 5 Nailed Decking is Required Direct Applied Ceiling of 1/2" Gypsum is Required 1 X 4 Strapping is Required Floor Decking: 23/32" Panels (24" Span Rating) Layout Scale: 3/16" = 1' JOIST AND BEAM LIST Plot ID Length Product Plies Qty MI 12' 1 3/4" x 9 1/2" 1.9E Microllam LVL 2 2 M2 8' 1 3/4" x 9 1/2" 1.9E Microllam LVL 2 2 M3 16' 1 3/4" x it 7/8" 1.9E Microllam LVL 3 3 HANGER LIST - Simpson Strong -Tie Company, Inc.® Plot ID Qty Product Label Top Nails Face Nails Member Nails Notes H1 1 U410 14-16d 6-10d H2 1 HU410 14-16d 6-10d - Joists By Others CREATED BY Mid -Cape Home Centers PO BOX 1418 465 ROUTE 134 SOUTH DENNIS, MA 02660 5083986071 FAX: 5083984559 n TJ•Xperte ~,W SYMBOL LEGEND Point Load .._._ Line Load Area Load HBO Beam By Others Q Detail Callout Label (See Framer's Pocket Guide) Required Bearing Length in inches (Adequate bearing has been provided if bearing length is not indicated.) LEVEL NOTES File Name: METER RES.12.20.JOB Level Name: ATTIC LOADS Plotted: 12/20/2004 16:04 Design Status: FIRST FLOOR .... 12/20/2004 13:25 SECOND FLOOR ... 12/20/2004 13:25 ATTIC LOADS .... 12/20/2004 13:23 ROOF LOADS ..... 12/20/2004 13:23 NOTE: Level design times indicated above provide assurance for proper level stacking. Design Methodology: ASD Floor Area Loads Vary: 25 to 30psf Live Load and 12 to 12psf Dead Load Maximum Joist Deflection: L/480 Live Load L/240 Total Load TJ -Pro Rating Information: Weighted Average: NA Lowest Rating: NA Highest Rating: NA Glued 5 Nailed Decking is Required Direct Applied Ceiling of 1/2" Gypsum is Required 1 X 4 Strapping is Required Floor Decking: 23/32" Panels (24" Span Rating) Layout Scale: 3/16" = 1'