HomeMy WebLinkAbout43 Nickerson Farm Way - Attic Loads_S
1
L-26 M;4 i
0
M
' 8
PR
' 3 1/2"
A complete TJ-Xpert framing plan requires the Trus Joist Framer's Pocket Guide
See Trus Joist Framer's Pocket Guide for Product Tradeeark Information
u
36'
HANGER LIST - Simpson Strong -Tie Company, Inc.®
Plot ID Qty Product Label Top Nails Face Nails Member Nails Notes
H1 1 U410 14-16d 6-10d
H2 1 HU410 14-16d 6-10d -
Joists By Others
CREATED BY
Mid -Cape Home Centers
PO BOX 1418
465 ROUTE 134
SOUTH DENNIS, MA 02660
5083986071
FAX: 5083984559
n TJ•Xperte
~,W
SYMBOL LEGEND
Point Load
.._._ Line Load
Area Load
HBO Beam By Others
Q Detail Callout Label
(See Framer's Pocket Guide)
Required Bearing Length in inches
(Adequate bearing has been provided if
bearing length is not indicated.)
LEVEL NOTES
File Name: METER RES.12.20.JOB
Level Name: ATTIC LOADS
Plotted: 12/20/2004 16:04
Design Status:
FIRST FLOOR .... 12/20/2004 13:25
SECOND FLOOR ... 12/20/2004 13:25
ATTIC LOADS .... 12/20/2004 13:23
ROOF LOADS ..... 12/20/2004 13:23
NOTE: Level design times indicated above provide
assurance for proper level stacking.
Design Methodology: ASD
Floor Area Loads Vary:
25 to 30psf Live Load and 12 to 12psf Dead Load
Maximum Joist Deflection:
L/480 Live Load
L/240 Total Load
TJ -Pro Rating Information:
Weighted Average: NA
Lowest Rating: NA
Highest Rating: NA
Glued 5 Nailed Decking is Required
Direct Applied Ceiling of 1/2" Gypsum is Required
1 X 4 Strapping is Required
Floor Decking: 23/32" Panels (24" Span Rating)
Layout Scale: 3/16" = 1'
JOIST AND BEAM LIST
Plot ID
Length
Product
Plies
Qty
MI
12'
1 3/4" x 9 1/2" 1.9E Microllam LVL
2
2
M2
8'
1 3/4" x 9 1/2" 1.9E Microllam LVL
2
2
M3
16'
1 3/4" x it 7/8" 1.9E Microllam LVL
3
3
HANGER LIST - Simpson Strong -Tie Company, Inc.®
Plot ID Qty Product Label Top Nails Face Nails Member Nails Notes
H1 1 U410 14-16d 6-10d
H2 1 HU410 14-16d 6-10d -
Joists By Others
CREATED BY
Mid -Cape Home Centers
PO BOX 1418
465 ROUTE 134
SOUTH DENNIS, MA 02660
5083986071
FAX: 5083984559
n TJ•Xperte
~,W
SYMBOL LEGEND
Point Load
.._._ Line Load
Area Load
HBO Beam By Others
Q Detail Callout Label
(See Framer's Pocket Guide)
Required Bearing Length in inches
(Adequate bearing has been provided if
bearing length is not indicated.)
LEVEL NOTES
File Name: METER RES.12.20.JOB
Level Name: ATTIC LOADS
Plotted: 12/20/2004 16:04
Design Status:
FIRST FLOOR .... 12/20/2004 13:25
SECOND FLOOR ... 12/20/2004 13:25
ATTIC LOADS .... 12/20/2004 13:23
ROOF LOADS ..... 12/20/2004 13:23
NOTE: Level design times indicated above provide
assurance for proper level stacking.
Design Methodology: ASD
Floor Area Loads Vary:
25 to 30psf Live Load and 12 to 12psf Dead Load
Maximum Joist Deflection:
L/480 Live Load
L/240 Total Load
TJ -Pro Rating Information:
Weighted Average: NA
Lowest Rating: NA
Highest Rating: NA
Glued 5 Nailed Decking is Required
Direct Applied Ceiling of 1/2" Gypsum is Required
1 X 4 Strapping is Required
Floor Decking: 23/32" Panels (24" Span Rating)
Layout Scale: 3/16" = 1'