Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
43 Nickerson Farm Way - Framing
aF' A complete TJ-Xpert framing plan requires the Trus Joist Framer's Poc -- - - See Trus Joist Framer's Packet Guide for Product Trademark Information i G11T LEVEL COMMENTS PLANS DATED 10.29.04 21 71 ' 6' _ 7' - 4 5, —► �15, 8" - -- 51 4" � 10, —� 12' a 36' 10, ACCESSORIES LIST Plot ID Length Product Plies Qty Rml 16' 1 1/4" x 11 7/8" 1.3E TimberStrand LSL 1 13 Bkl 1' 1 11/16" 11 7/8" TJI 230 Blocking Panels 1 26 Bkl* 9' 6 1/2" 11 7/8" TJI 230 Blocking Panels 1 1 Shl 4' x B' 23/32" Panels (24" Span Rating) 1 55 Bk*, Random length blocking panel cuts Bk, Blocking Panels; Rm, Rim Board HANGER LIST - Simpson Strong -Tie Company, Inc.® Plot ID Qty Product Label Top Nails Face Nails Member Nails Notes H1 15 IUT3512 10-N10 2-N10 H2 2 HU9 18-10d 6-N10 H3 4 IUT9 H -N10 2-N10 H4 1 U410 14-N10 6-N10 Hanger Notes: 1 5 10, ACCESSORIES LIST Plot ID Length Product Plies Qty Rml 16' 1 1/4" x 11 7/8" 1.3E TimberStrand LSL 1 13 Bkl 1' 1 11/16" 11 7/8" TJI 230 Blocking Panels 1 26 Bkl* 9' 6 1/2" 11 7/8" TJI 230 Blocking Panels 1 1 Shl 4' x B' 23/32" Panels (24" Span Rating) 1 55 Bk*, Random length blocking panel cuts Bk, Blocking Panels; Rm, Rim Board CREATED HY Mid -Cape Home Centers PO BOX 1418 465 ROUTE 134 SOUTH DENNIS, MA 02660 5083986071 FAX: 5083984559 n TA ert* T~Pw JOB COMMENTS DON MEYER MEYER RES. LOT 4 NICEERSON FARM NY S YARMOUTH MA I SYMBOL LEGEND I Point Load Line Load Area Load O Detail Callout Label (See Framer's Pocket Guide) L Required Bearing Length in inches u (Adequate bearing has been provided if bearing length is not indicated.) LEVEL NOTES File Name: MEYER RE5.12.20.JOB Level Name: FIRST FLOOR Plotted: 12/20/2004 13:41 Design Status: FIRST FLOOR .... 12/20/2004 13:25 SECOND FLOOR. -..12/20/2004 13:25 ATTIC LOADS .... 12/20/2004 13:23 ROOF LOADS ..... 12/20/2004 13:23 NOTE: Level design times indicated above provide assurance for proper level stacking. Design Methodology: ASD Floor Area Loading Is: 40psf Live Load and 12 psf Dead Load Maximum Joist Deflection: L/480 Live Load L/240 Total Load TJ -Pro Rating Information: Weighted Average: 51 Lowest Rating: 41 Highest Rating: 70 Glued 6 Nailed Decking is Required Direct Applied Ceiling of 1/2" Gypsum is Required 1 X 4 Strapping is Required Floor Decking: 23/32" Panels (24" Span Rating) Normal O.C. Spacing = 1611* Standard Blocking: Bki* *Unless noted otherwise Layout Scale: 3/16" = 1' JOIST AND BEAM LIST Plot ID Length Product Plies Qty Al 48' 11 7/8" TJI 230 joist 1 5 A2 46* 11 7/8" TJI 230 joist 1 3 A3 38' 11 7/8" TJI 230 joist 1 5 A4 36' 11 7/8" TJI 230 joist 1 2 A5 32' 11 7/8" TJI 230 joist 1 4 A6 26' 11 7/8" TJI 230 joist 1 12 A7 14' 11 7/8" TJI 230 joist 1 8 A8 12' 11 7/8" TJI 230 joist 1 3 A9 6' 11 7/8" TJI 230 joist 1 3 M1 32' 1 3/4" x 9 1/2" 1.9E Microllam LVL 3 3 M2 20' 1 3/4" x 9 1/2" 1.9E Microllam LVL 2 2 M3 14' 1 3/4" x 9 1/2" 1.9E Microllam LVL 2 2 M4 20' 1 3/4" x 11 7/8" 1.9E Microllam LVL 2 4 145 18' 1 3/4" x 11 7/8" 1.9E Microllam LVL 4 4 M6 16' 1 3/4" x 11 7/8" 1.9E Microllam LVL 1 2 M7 6' 1 3/4" x 11 7/8" 1.9E Microllam LVL 1 2 M8 4' 1 3/4" x it 7/8" 1.9E Microllam LVL 1 2 P1 14' 3 1/2" x 11 7/8" 2.0E Parallam PSL 1 1 P2 12' 3 1/2" x 11 7/8" 2.0E Parallam PSL 1 1 CREATED HY Mid -Cape Home Centers PO BOX 1418 465 ROUTE 134 SOUTH DENNIS, MA 02660 5083986071 FAX: 5083984559 n TA ert* T~Pw JOB COMMENTS DON MEYER MEYER RES. LOT 4 NICEERSON FARM NY S YARMOUTH MA I SYMBOL LEGEND I Point Load Line Load Area Load O Detail Callout Label (See Framer's Pocket Guide) L Required Bearing Length in inches u (Adequate bearing has been provided if bearing length is not indicated.) LEVEL NOTES File Name: MEYER RE5.12.20.JOB Level Name: FIRST FLOOR Plotted: 12/20/2004 13:41 Design Status: FIRST FLOOR .... 12/20/2004 13:25 SECOND FLOOR. -..12/20/2004 13:25 ATTIC LOADS .... 12/20/2004 13:23 ROOF LOADS ..... 12/20/2004 13:23 NOTE: Level design times indicated above provide assurance for proper level stacking. Design Methodology: ASD Floor Area Loading Is: 40psf Live Load and 12 psf Dead Load Maximum Joist Deflection: L/480 Live Load L/240 Total Load TJ -Pro Rating Information: Weighted Average: 51 Lowest Rating: 41 Highest Rating: 70 Glued 6 Nailed Decking is Required Direct Applied Ceiling of 1/2" Gypsum is Required 1 X 4 Strapping is Required Floor Decking: 23/32" Panels (24" Span Rating) Normal O.C. Spacing = 1611* Standard Blocking: Bki* *Unless noted otherwise Layout Scale: 3/16" = 1'