Loading...
HomeMy WebLinkAboutEngineered Plan - 2015SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE TOP FOUND. EL. 41.2' 1 FILTER FABRIC OVER STONE 4 0.5 MINIMUM .75' OF COVER OVER PRECAST *38.1' PRECAST H-10 RISERS (TYP.) 2'0 37.50' 4"ozKJ140 PVC PIPES LEVEL 1ST 2' 10" 1500 GAL H-14TEE 1z TEE SEPTIC TANK7.25•j16' ; GAS BAFFLE..,' °a�o�o o°o° 4' LIQ. LEVEL (ACME OR EQUAL) . 3 36.99' ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE 2% SLOPE REQUIRED- OVER SYSTEM Z41.0' V^O00000000000000000000000000000000< 00000000000000000000000000000000o^o0^0�0'000^0^0^0'00000 ,o'0�o 0 0 0000 0 ECuFOR vnLEVELNESS6"CRUSHED STONE OR MHANICAL \/11 L1\-ILJI LU COMPACTION. (15.221 [21) (2 % SLOPE) (--L% % SLOPE) (1 % SLOPE) FOUNDATION 30' SEPTIC TANK 9' D' BOX 5' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR F-991 PROPOSED SPOT EL. TH1 TEST HOLE 2� SLOPE OF GROUND • UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING NOTE: CONNECT PLUMBING FOR LAUNDRY SYSTEM TO BUILDING SEWER OR SEPTIC TANK. LOCATE AND FILL OLD GREYWATER SYSTEM. PROP. VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WITH HOMEOWNER CONSULTATION) --\ TEST HOLE LOGS OVER HEAD UTILS. ENGINEER: ARNE H. OJALA, PE, SE WITNESS: AMY VON HONE, RS DATE: AUGUST 12, 2010 PERC. RATE = < 2 MIN/INCH CLASS ' SOILS 4 ELEV. 0°1 41.0' A SL 1OYR 4/2 B MS 24/1 1OYR 5/6 39.0' PERC C MS 1OYR 6/6 1 120" I 131.0' NO GROUNDWATER ENCOUNTERED PINE X 9' \ PI G � 5 15,E o � 4. \0 4" � pp RNAI O "A c '�. 3 7 N \� Scale: 1"= 20' 0 10 20 30 40 50 FEET OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 24' X 8.5' (NO STONE PROPOSED) 5.04' LEACHING FACILITY BOTTOM TH 1 EL. 31.0' NOTES 1. DATUM IS APPROX. NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN 1S FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND Sc OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. NOTE: SEPTIC TANK IS NOT DESIGNED FOR VEHICLE LOADING DATE DANIEL A. OJALA, P.E., P.L.S. LOCUS MAP NOT TO SCALE ASSESSORS MAP 91 PARCEL 33 SYSTEM DESIGN. GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. H-10 SEPTIC TANK LEACHING: 4.72 SFAF x .6.25',.LENGTH 29.5 SF .PER HIGH CAPACITY INFILTRATOR UNIT 330 GPD/0.74 GPD/SF = 445.9 SF LEACHING REQ'D 445.9 SF/29.5 SF/UNIT = 15.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (16) H-20 HIGH CAPACITY UNITS IN FIELD CONFIGURATION OF 4 ROWS OF 4 UNITS 16 UNITS x 29.5 SF = 472 SF > 445.9 SF (OK) J APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 70 OUT OF BOUNDS DRIVE SOUTH YARMOUTH PREPARED FOR JIM & MARY BRESNAHAN AUGUST 13, 2010 OCTOBER 7, 2015 (NEW OWNER) off 508-362-4541 I fax 508-362-9880 downcope.com d®Yn CII►.Pe eagiaeering, i7c. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 , MAI • LOCUS MAP NOT TO SCALE ASSESSORS MAP 91 PARCEL 33 SYSTEM DESIGN. GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. H-10 SEPTIC TANK LEACHING: 4.72 SFAF x .6.25',.LENGTH 29.5 SF .PER HIGH CAPACITY INFILTRATOR UNIT 330 GPD/0.74 GPD/SF = 445.9 SF LEACHING REQ'D 445.9 SF/29.5 SF/UNIT = 15.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (16) H-20 HIGH CAPACITY UNITS IN FIELD CONFIGURATION OF 4 ROWS OF 4 UNITS 16 UNITS x 29.5 SF = 472 SF > 445.9 SF (OK) J APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 70 OUT OF BOUNDS DRIVE SOUTH YARMOUTH PREPARED FOR JIM & MARY BRESNAHAN AUGUST 13, 2010 OCTOBER 7, 2015 (NEW OWNER) off 508-362-4541 I fax 508-362-9880 downcope.com d®Yn CII►.Pe eagiaeering, i7c. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 , MAI