Loading...
HomeMy WebLinkAbout18 North Sandyside Lane - Site Plan 2LEGEND 99 - EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 99 PROPOSED SPOT EL. T�Hy,1, A 1 TEST HOLE 25 SLOPE OF GROUND C-0-) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 5 BEDROOMS 0 110 GPD = 550 GPD USE A 550 GPD DESIGN FLOW EXISTING SEPTIC TANK: 550 GPD (1.5) = 825 (OLD CODE) **RE -USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SIDES: 2 (42 + 12.83) 2 (.74) = 162 GPD BOTTOM 42 x 12.83 (.74) = 398 GPD TOTAL: 756 S.F. 460 GPD USE (4) 500 GAL. H-10 LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND Ya=outh Health Department APPROVED ":9 U_ MA APPROVED DATE BOARD OF HEALTH "INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON H-10 SEPTIC TANK IF NOT SUITABLE ZONING SUMMARY ZONING DISTRICT: R-40 DISTRICT MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 20' MIN. REAR SETBACK 20' 10-261 FOUNDATION- EXIST. ACCESS COVERS TO WITHIN 6" OF FIN. GRADE SYSTEM PROFILE (NOT TO SCALE) 1 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE MUM .75'1 OF COVER OVER PRECAST I I + 2% SLOPE REQUIRED OVER SYSTEM4� 1.51J, J, 41 BLOCKS OR 40.4' 4"OSCH40 PVC MORTAR ALL PRECAST RISERS PIPES LEVEL 1ST 2' 4 COMPONENTS H-10 ENDS 1 (TYP.) INV'S EL. 38.0' FSID S , I SID 38.83 10* EXISIING 14" TEE 1000 GAL H-10 TEE *' ' ° ®ooa OOOO -�J®OO SEPTIC TANK** 39.Ot ° oo o .o ° 00008 ®f�J®�®®�G'��C7 �OOOa�CiO�®® '0°0 u ° 0 0 0��0 �0000�oo o�0 0 0 0 0 0 e O 0 0 0 o O ;00000° °o °° ° ° ° ° ° °ao°° ®ooa®��o®�® ®®®®®®®ori GAS BAFFLE ° °Z.-O.C.0°0°0°0 °° N °O o 0 0 ° .o:e,°,o o°°°o° 'o°o°o°o° 38.37' 38.20' � °°°°°°° ' °°%°8 36.0 WATER -TEST D'BOX FOR LEVELNESS H 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. -10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. ALL AROUND PRECAST STRUCTURES (4) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 42.0' X 12.83' COMPACTION. (15.221 [2]) 5.6' SEPTIC TANK (_L5 % SLOPE) - 14' - D' BOX (-L-% SLOPE) - 22' - LEACHING FACILITY 30.4' BOTTOM TH-1 NO GROUNDWATER FOUND _ NOTES 1. DATUM IS APPROX. NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. B. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED. FILE L PY LOCUS MAP NOT TO SCALE ASSESSORS MAP 122 PARCEL 130 LOCUS IS WITHIN FEMA FLOOD ZONE C SITE DOES NOT LIE WITHIN ZONE II TEST HOLE LOGS ENGINEER: DANIEL A. OJALA, PE, SE WITNESS: AMY VON HONE, RS DATE: NOVEMBER 16, 2010 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS 1 ELEV. 2 ELEV. a 0 m o Rood w Vic` 41.6' A 2° LS LS 1CYR 4/2 Locu a c B o Sand P� B LS O 36" a V Dennis 38.6' Pond 0 LOCUS MAP NOT TO SCALE ASSESSORS MAP 122 PARCEL 130 LOCUS IS WITHIN FEMA FLOOD ZONE C SITE DOES NOT LIE WITHIN ZONE II TEST HOLE LOGS ENGINEER: DANIEL A. OJALA, PE, SE WITNESS: AMY VON HONE, RS DATE: NOVEMBER 16, 2010 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS PERC M/CS I I M/CS 2.5Y 7/4 2.5Y 7/4 132" 30.4' 126" 31.1' NO GROUNDWATER ENCOUNTERED TIT[.111H 5 SFE PLAN OF 18 NORTH SANDYSIDE LANE YARMOUTH PORT •_*S :2VEyc!R c DATE DANIEL A. OJALA, P.E., P.L.S. PREPARED FOR MARK & JUDITH LINK NOVEMBER 19, 2010 Scale: t "= 20' 0 10 20 30 40 50 FEET I off 508-362-4541 fox 508-362-9880 downcape.ccm down cope engineering, MC. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 LL GUry 1 ELEV. 2 ELEV. p" 41.4' 0" - 41.6' A A- LS LS 1CYR 4/2 1CYR 4/2 B B LS LS 36" 1CYR 5/6 38,4'10YR 36" 5/6 C 38.6' C PERC M/CS I I M/CS 2.5Y 7/4 2.5Y 7/4 132" 30.4' 126" 31.1' NO GROUNDWATER ENCOUNTERED TIT[.111H 5 SFE PLAN OF 18 NORTH SANDYSIDE LANE YARMOUTH PORT •_*S :2VEyc!R c DATE DANIEL A. OJALA, P.E., P.L.S. PREPARED FOR MARK & JUDITH LINK NOVEMBER 19, 2010 Scale: t "= 20' 0 10 20 30 40 50 FEET I off 508-362-4541 fox 508-362-9880 downcape.ccm down cope engineering, MC. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 LL GUry