Loading...
HomeMy WebLinkAbout33 Norton Road - Septic System Profile1190.00,h OF 35 LOF 36 O UTILITY Q b � � FULL 9ASEdfE'NT - -, Existin,q.. Fie !, d UTILITY ' cn 33,x, 8' W x �PRO'OSE'D) 8 r � rbIIN SLA6� L J �.26 x26' (PROPOSED) 1 o' —� cp \\ I I M o .�3 Irl o PAYED I I O (PROPOSED)— SITS' PL�1 N y��o, SCALE.- 1" = 20' 14. Septic System >. Basis of design No Garbage grinder Percolation rate =<2 minutes/inch Number of bedroom "Equivalents" =930 CPD Effective Area required = 330 s f. Effective Area provided = 330 s f. 2. Site Preparation — a) As required by the Town of jYest Yarmouth, ' prior to any construction activity, the septic, system must be staked—out by the' Design; Engineer according ' to, the approved ,elan b) All trees, stumps, boulders, debris and otrier materials that will interfere with construction must be removed from the area of construction. c) All fill material must be approved by the Town of West Yarmouth Health Department , or the Design Engineer prior to placement 3. Septic System — aj House sewer is to be 4" Extra Heavy Cast Iron`Pipe or equal set at a slope of 0.25'%ft. Pipe is ,'o be bedded in compacted soil free of large stones and laid true to grade and line. Replace existing pipe if necessary b) At the ., time of installation, the existing tank is to be pumped out by a licensed contractor and inspected It is recommended that the Town Sanitation ba contacted prior to this activity. If the tank is found to be a 1000 gallon Precast Concrete unit in satisfactory condition, it -need not be replaced Should the tank fail to meet the above-.. criteria, it must be replaced with a 1500 gallon Tank by Acme, Shorey, or equal. Set the tank at inverts with inverts at- the elevations of the o.+-iginal tank.. Mori;.- the annular space around inlet and outlet pipes 6" of 'crushsd stone to be placed below new tank prior to installation. c) Connect the tank to the distribution FielY with 4" PVC Pipe Sch40, or equal. Set pipe at a slope of 6� 1,25"/ft. free from sags or depressions. d) The distribution field is to be 3 Flow diffussers with 4' stone sides & ends. Set the distribution ,field level at the invert distribution elevations shown ( see the typical section detail J e) Uniform Distribution —Inverts _of Overflow Distribution Box to be 2" higher than the invert of piping trench. Distribution Box to be water tested for levelness and set on 6" stone base 1),.Distribution Field to be loamed and seeded as specified immediately upon final inspection of the system. Final . grade to shed surface water. WH B. Installation and Backfill 1. General Construction a) The elevations shown may be raised but not lowered without the consent of, the Design Engineer Questions regarding the details of the construction should be addressed prior to the commencement of construction. b) If the installer finds site conditions to vary significantly from the conditions shown, the Design Engineer is to be notified immediately. The Design Engineer shall veri,y soil conditions of a medium sand to a level 4' below leaching area. c) In addition to the specifics contained in these notes and on :the plan, the Contractor is required to be familiar with and follow the provisions within the Massachusetts Public Health Code and any other standard appropriate to insure the health and safety of the workmen and . homeowner. 2. Surface Requirements a) Limit the area of disturbance to within 35" of overall dimension of the septic system. Minimize unnecessary disruption of stable vegetation in areas not diectly involved in Ike construction. b)' Final grading, loaming, fertilization, and seeding should take place as soon as is practical. Provide at least 4 of topsoil and loam in areas to be planted with grass. The following recommendations may be followed. TEMPORARY COVER Annual Ryeg-ass 4011/ac. 3/1 to 6/15 -� 8/1 to 10/1. PERMANENT COVER Kentucky Bleu Crass 20#/ac. Creeping Red Fescue 20#/ac. Perennial Ryegrass 5#/ac! TOTt'L 45#/ac. 4/15 to 6/15 8/15 to 9/15 e) Stabilization outside of the above seeding dates may be accomplished by applying a—.--,' securing hay/srrazu zz t:� = r ale of 2 — 3 tons/ac. LOCUS — "waived" for this plan GEN�R�1L NOTE'S .OESIGN DATA - VO 04BBA0E DISPOSAL 1. Contractor to be responsiblefor the location Daily Flo v., (3) BDRMS, x 110GPD = 3306!PD of all utilities, above and underground, prior Septic Tark 330 CPD x 2009' = 660 CPO Use 100A Callon Precast Septic Tank - existing to any excavation or construction. Leachin Jacility 2. Septic System to be installed in compliance with Use raj 4' x 8' Flowdiffussors w/4' of stone 310 CMR 15.00: Title V. 3 This Plan is not to be used for property line Capacity DATE.. ENC'R. TOWN WITNESS.• i Consultants Revisions REV #1 DEC 2, 1998 Date 6 NOV '98 Scale l„ = 20' DRAWING: SITZ'—SZX4 CZ PL14N 33 Norton Road W Yarmouth, MA prepared for - David Marcotte determination sidewall.• 88 x 1 x .74 = 65. 1 bottom 12 x 32 x .74 = 284.2 4" seh40 PVC nide NOTE. min 1/8 2" layer of 3/8" peastone over 4. Bottom and sides of Septic Tank to be tota' .: 349.3 CPO pitch 48" of washed stone waterproofed at the factory spread. all around 5. Remove impervious material for a 5' radius TEST HOLD' LOG Match invert at tie in New around the leaching facility &replace with to be completed Distribution _.. -- , , clean sand. This- removal to be certified by after/prior leaching _ EL 100 BOx. the design engineer. (provide 24 hr notice see Gen Note # 7 EL 98,5 3- Flow Di sser 6. „ _ Allowed under Maximum Feasible _ 16"' :,,5oo�,,oa000 ,;,o0oo6�00000 PHGW - Compliance" — 310 CMR 15.405.• (1) i To Soil p ne Existing 1, 000 gal -Wo o 0 08 -Woo stone -_.. 7 Existing subsurface conditions to be verified Sub Soil tank, add gas baffle and recorded by the design engineer - during construction. see Installation' Backfill note: 8. An "AS BUIL7" septic plan with elevations and Medium Sand rT 1., b. Test Hole LOG to be submitted to Health Dept. ,S�'PTIC SYS'7'.�1 _ 12, - NO H2O DATE.. ENC'R. TOWN WITNESS.• i Consultants Revisions REV #1 DEC 2, 1998 Date 6 NOV '98 Scale l„ = 20' DRAWING: SITZ'—SZX4 CZ PL14N 33 Norton Road W Yarmouth, MA prepared for - David Marcotte