HomeMy WebLinkAbout8 Old Hyannis Road - Septic Design 2TOP OF FOUNDATION ELEV. _ -% (ASSUMED) 4' CAST IRON PIPE (OR EQUAL) MINIMUM PITCH 1/4' PER FT. 20 FT. MINIMUM FROM CELLAR 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE CONCRETE COVERS 4' SCHEDULE 40 PVC PIPE MIN. PITCH 1/8' PER FT. CLEAN SAND LOAM AND SEED 2' LAYER OF 1/8' TO 1/2' :YID aVENT NOT REQUIRED vANCHORCONCRETE LEGEND: EXISTING SPOT ELEVATION 00,0 EXISTING CONTOUR----00---- FINAL SPOT ELEVATION 0 FINAL CONTOUR SOIL TEST LOCATION UTILITY POLE -�- TOWN WATER —W W CATCH BASIN �® j GAS LINE CLEAN OUT- CESSPOOL C.P. O SOIL TEST DATE OF SOIL TEST SOIL TEST DONE BY WITNESSED BY OBSERVATION HOLE ELEV.= PERCOLATION RATE MIN./INCH AT INCHES `ECFV. / -TMIN.' 2.0. • r d®®®®EiI3EI 3E3E 1 _ LEVEL ®®tom®®®®®®®� �e24 ° ELEV. BAFFLE ELEV. = 6' SUMP ELEV. _ b �®®®®®®®®d® . ELEV. v DISTRIBUTION �S ELEV. m / — 500 GALLON DRY WELLS LIQUID OUTLET BOX STONE IN AN DEPTH TEE (TO BE PLACED ON FIRM BASE)z \ 4 FEET 14 INCHES TO BE WATER TESTED TRENCH FORMATION 3 5 FEET 19 INCHES IF MORE THAN ONE OUTLET 6 FEET 24 INCHES 1500 GALLON 7 FEET 29 INCHES (TO BE PLACED ON FIRM BASE) SOIL ABSORPTION ZONE c'Y �ZI J.S / �� 8 FEET 34 INCHES SEPTIC TANK 3/4' TO 1 1/2'J SYSTEM (SAS) INDEX /S 3 jov WASHED STONE ADJUST 1 7S SEWAGE DISPOSAL SYSTEM PROFILEoesERVED` SGS PROBABLES WATER TAME `j ELEV. q2 R� `'� � 1 � /00 / NOT TO SCALE BOTTOM OF TEST HOLE ELEV. _ l 4 f C, 45 19 RpW � q\� ` � \ \ � �� � �r�� RoPOSEo a QQ� Of P Z/X 111,0 ! �• � � \ � � �, 5 °��D,/�" 1 � � Erb, � ` �- Q •. � �. — � � . , � , \ , ► / 1 / 1 \ g4r 7 !� `bgzl L q vjA Do 01 A l ! I F S I 1 1 l 95. 9A � ! �\ —' I � i , 1 ) I 8/ 1 t ILA 9/ � x 1L r DEPTH HORIZ TEXTURE COLOR MOTT. I OTHER WATER ENCOUNTERED AT ELEV. _ OBSERVATION HOLE ELEV,-- PERCOLATION RATE MIN./INCH AT INCHES DEPTH HORIZ I TEXTURE COLOR MOTT. OTHER WATER ENCOUNTERED AT ELEV. _ DESIGN CALCULATIONS NUMBER OF BEDROOMS GARBAGE DISPOSAL UNIT NO TOTAL ESTIMATED FLOW ( 110 GAL/BR./DAY X 3 BR.) 330 GAL/DAY REQUIRED SEPTIC TANK CAPACITY /S00 GAL ACTUAL SIZE OF SEPTIC TANK 1500 GAL SOIL CLASSIFICATION 7 - DESIGN PERCOLATION RATE cwnN• EFFLUENT LOADING RATE SQ /DAY/S.F. LEACHING AREA LEACHING CAPACITY (AREA X RATE) GAL/DAY RESERVE LEACHING CAPACITY GAL/DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN OF RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6' OF FINISHED GRADE 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT, OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDEC OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL 'DIG -SAFE' AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. B. PARCEL IS IN FLOOD ZONE C 9. LOT IS"SHOWN ON ASSESSORS WAP AS PARCLL la ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND FOR A MINIMUM OF 5' AROUND LEACHING FACILITY AND BE REPLACED WITH MATERIAL AS SPECGTfD IN 310 CMR 15.255c(3). APPZOtlEO YAI#,9,CJTN CQ',4',,,ITTEE '6e SEP 7 Ana O. APPROVED: BOARD OF HEALTH DATE AGENT 01998 CRAIG R• SHORT,_, D rv�vis s 1 ,�OtA Nyp.vv/S RD h i z r ` i o V V �` PROPOSED SEPTIC DESIGN FOR G: /vE UL7 PROJECT_ LOCATION LOT 5 OLD /-% Y/P/V/ //:s RZ) CRAIG R SHORT PROFESSIONAL ENGINEER 508- SOUTH DENNIS. MASS 398-8311 02660 SCALE DATE O/O� I JOB N0. lZ— 8q8 REVISED LOCATION MAP RE"SED SHEET / OF / I 01998 CRAIG R• SHORT,_,