Loading...
HomeMy WebLinkAbout71 Old Hyannis Road - Site PlanTOP OF FNDN = EL 72.00 EL71.5+ ACCESS COVER WITHIN 6" TO FIN. GRADE EI -69+ MINIMUM .75' OF COVER OVER PRECAST PROPOSED. 1,500 GALLON SEPTIC 6595 TANK (H-10)5EG AS ACCESS COVER (WATERTIGHT) WITHIN 6" TO FIN. GRADE J1//--RUN PIPE LEVEL '''7�'' /-FOR FIRST 2' /I H-10 �- - 2" DOUBLE WASHED PEASTONE 2% SLOPE RFOUIRFn nVFR cvcrru o FLOW LINE EL 5.5 V6" CRUSHED STONE OR MECHANICAL DEPTH OF FLOW = 4' COMPACTION. (15.221 [21) 3.5' O SIDES 10 3' O ENDS REQUIRED TEE SIZES: INLET DEPTH - 10" MIN. BELOW FLOW LINE H_P0 OUTLET DEPTH = 14" MIN. BELOW THE FLOW LINE 14 I off$ _ ( 2 MIN. SLOPE) ( MIN. SLOPE) ( MIN. SLOPE) 3/4" TO 1 t/2" DOUBLE WASHED S"'ONE FOUNDATION 22' SEPTIC TANK 10'-QiD''CB�OX 'D Ti�i4T�Ti� LEACHING FACILITY SEPTIC .DESIGN: (WnAGE DISPOSER IS NOT ALLOWED) -sn + �Q+"+ z NUMBER OF BEDROOMS' 3 (NOT TO S('ALE) 3' MAX. 3.5' O SIDES 3' O ENDS 18' EI -64.67 14' DESIGN A 330 G/P REQUIRED DESIIGNRFLOW 30 G/D 4.9� USE SEPTIC TANK I B.g' 330 G/D (2) = 660 G/D USE PROPOSED 1,500 GALLON SEPTIC TANK LEACHING MOF TH 58.8 SIDE AREA: 2 x 2' x (9.83'+31') - 163.3 SF SEE SOIL LOGS BOTTOM AREA: 9.83' x 31' = 304.7 SF SIDES: 163.3 SF BOTTOM OF 58.6 + BOTTOM: 304.7 SF SEE SOIL LOGS TOTAL: 468 SF PROPOSED CAPACITY: 468 SF x X 0.74 G/D/SF - 346.3 G/D O.K. - USE: (6) H-20 HIGH CAPACITY INFILTRATORS WITH 3.5' STONE AT SIDES, 3' AT ENDS, AND 14" BELOW. 512'"�C MM DESIGN D= / JANE A. RYER / BENCHMARK: DOUGLAS A. ROBERTCONCRETE BOUND I a. SON / EL.71.33 I /I 1 CERT# . \ - na , / I / + + 1 I I I I I I (' / ^ / 8 `a�\ \ \ / ^ / I LCP 39085 \ I o m 1 / / / f�Ncll \ 1 1.3CB/DH FIND / / / (DISPL.) 365.61 \ \ \ ^ ,� 4./27// / ! 73 71 PROPOSED X 71.0,- , 1 / /off!! Ir \ \ / ' 070.6 \ \ DRIVEWAY o LOT 1 71s 42,30 s.f. ' / / / !p 0.97 ac. r I _>- X 70.6 PROPOSED 3jar- 199.81 0 - \ / / o o BEDROOM DWELLING / N , l/ I n \ TOP OF FNDN=EL. 72.00p A 0 - _.-- --oo i / /l If 11 1 1 !I (l 1 /' / �V/ \ 9 a o X 71.5 �7gs0' i tr LOT 3�C o00N �3 o c' lb /38/) / / / 11 1 \ / / lba 1. 6 Lnr) l / 0 c' 0 1 \ 1 6 _-----64-- o l l(64 6 65 0 J1 DO _194.06 s9\ I 1 LOT 2 SCALE 1" 4n APPROVED DATE - BOARD OF HEALTH 99-403 }-i6�0 f���J MA DATE ARNE H. 444& WATER SHUT OFF VALVE v TO BE LOCATED ---W- EXISTING SOIL CLASS: ED LOCATION GAS SHUT OFF VALVE TO BE LOCATED -�_ EXISTING GAS LINE SANDY LOAM 10YR 2 TO BE LOCATED -p` EXISTING PHONE LINE TO BE LOCATED EXISTING ELECTRIC LINE (24 GAL. < 15 MIN,) TO BE LOCATED EXISTING CABLE T.V. LINE 9": TO BE LOCATED -70- EXISTING CONTOUR + 70.6 EXISTING SPOT GRADE PROPOSED CONTOUR x PROPOSED SPOT GRADE THI Q 84,6 SOIL TEST HOLE SEE TEST HOLE LOG(S) Y DENNIS `POND%~ Uli 1 LOCUS MID CAPE a EXIT 1 7 / HIGHWAr - RT,6 LOWS M" - SCALE 1" = 2000' ASSESSORS MAP 94, PARCEL 1, LOT 1 FLOODZONE: C *ZONING DISTRICT: R-40 MINIMUM YARD SETBACKS: FRONT - 30 ft. SIDE/REAR - 20 ft. *TO BE CONFIRMED BY BUILDING COMMISSIONER DEPTH (in.) TH1 ELEVATION 0'O/A 87.6 SOIL CLASS: I (SANDS, LOAMY SANDS) PERC RATE: < 2 MPI (5 MPI DESIGN) SANDY LOAM 10YR 2 PRESOAK: 0:00:00-0:09:45 A4 (24 GAL. < 15 MIN,) B' 66.9 9": 0:09:45 LOAMY SAD BOTTOM PERC: AT 66" EL.62A 2.SY56 I NO WATER OBSERVED 36" Q 84,6 FINESAND DATE: 1/10/00 2.5 Y 6/4 ENGINEER: MICHAEL S. FARIA, SE 1,' ----- gg•6 (DOWN CAPE ENGINEERING) lO T /1^43 t11y1pAt HOU TEST WITNESS: AMY VON HONE, RS EXCAVATOR: OWNER'S EXCAVATOR SCALE DEPTH (in.) TH2 ELEVATION 0' 70.6 SOIL CLASS: I (SANDS, LOAMY SANDS) SAND LOAM 10 YR 4 2 PERC RATE: < 2 MPI (5 MPI DESIGN) (ASSIGNED O Cl) 8' 89.9 LOAMY SA D 2.5 p 6 NO WATER OBSERVED 48" 66.6 1TION OF EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN IS APPROXIMATE. PRIOR TO ANY EXCAVATION ON THIS SITE, THE EXCAVATING CONTRACTOR SHALL MAKE THE REQUIRED 72 HOUR NOTIFICATION TO DIG SAFE (1-868-344-7233) AND ANY OTHER UTILITIES WHICH MAY HAVE CABLE, PIPE OR EQUIPMENT IN THE CONSTRUCTION AREA FOR VERIFICATION OF LOCATIONS. 2. ALL SEPTIC WORK AND MATERIALS TO CONFORM TO 310 CMR 15.00 TITLE 5 AND YARMOUTH HEALTH REGULATIONS. 3. VERTICAL DATUM ASSUMED FROM QUAD. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHTO-H10. 5. THIS PLAN IS FOR A PROPOSED SEWAGE DISPOSAL SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE, 6. ALL SEPTIC PIPING SCH-40-4" PVC UNLESS NOTED. 7. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 8. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 9. PIPE JOINTS TO BE MADE WATERTIGHT. 10. WATER TEST D -BOX FOR LEVELNESS. off. 508-362-4541 fax 508-362-9880 down cape engineering, inc. o"AA-4, of aJCIVIL ENGINEERS ARNE' LAND SURVEYORS 6346 939 main st. yarmouth, ma 02675 xos S. TITLE 5 SITE PLAN OF LAND IN YARMOUTHPORT. MA PREPARED FOR SID SIDDHARDTH LOCATED AT LOT 1 OLD HYANNIS ROAD YARMOUTHPORT, MA 02675 SCALE: 1 "=30' DATE: 9-25-00 REVISED: 2-9-01 30 03� a n y 60 90 Ft.