Loading...
HomeMy WebLinkAbout83 Old Hyannis Road - Site Plan 2TOP FNDN. AT EL. 80.0' ACCESS ,, .. /0 �6 77.0' PROPOSED 76.6' GALLON SEPTIC TANK (H- 10 ) (-L% % SLOPE) DEPTH OF FLOW = 4' TEE SIZES: INLET DEPTH = 10„ OUTLET DEPTH = 14" FOUNDATION- 2' I 1 1 1 I I 85 I !JI SEPTIC PROFILE TO WITHIN 6" OF FIN. GRADE (NOT TO SCALA INSPECTION PORT WITHIN 3" GRADE ACCESS COVER (WATERTIGHT) TO MARK WITH MAGNETIC TAPE OR EQUIVALENT 5' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM 78,0 - 79.0 LRUN PIPE LEVEL 2" DOUBLE WASE PEASTONE L--LIL- � %-FOR FIRST 2' /OR FlLTER FABRI ,6:35' /II / 3^ MAX. CRUSHED STONE OR MECHANIAL IPACTION. (15.221 [2]) (-L% % SLOPE) (! % SLOPE) SEPTIC TANK 44' Q \ J r 5' REMOVAL OF UNSUITABLE 01 REQUIRED $� 0D' ♦ �p \ \ \ \ \ \ \ \16 - RAROUND PERIMETER OF LEAC IN FACILITY, WN \ \ f ( DOTO SUITABLE SOIL LAYERLACE NTH CLEAN M TO C2 LAYESAND, TO H \ /II I 1 I 1 1! r! MEETSPEC Fl SPECIFICATIONS OF 3 0 CMD 15.255(3) TH o \ 79 3A J l l r II 1 Jl 1 I I\ \ 1 l//// ll1 J1111lJ TH, 40, 039, s. f. 79.2' 26.25' // // / /00 C II Il 1 .2 zz� Q��e 'oo• I 4.00' 4.00' II I �SOh o 0' \10.0 PROP. 80.0' LL,�TF � OO'�° ELEC. HANDBOX TEL. & CATV RISE / I/ /IG0' N I / I GARAGE / I/ / oAas /J I / / Is �w//�/ / h / BENCH MARK - H / ^ / / ON TAG# 2068 EL / °' / / / ' / / // PF OP. RET. as 1__/ l // / // / WALLS I Co 23.1' / / / / /I / / / / F / / / ///! / T- 861 i%p' RI }S VIE - 1110/ ATE // ! // //372.5/-----�-- \ Lcb - 6 // \ - / }I PPNEO OR1vEWP PROP. RET. WALL i ExIST1 WALL } } X m I }} { \ ELEC. TRANSFOR 0 z W \ AND METER ZLo / a Q N NI o v TEL. & CATV RISERS I N DCE ¢#99-403 LOMA 3/4" TO 1 1/2" DOUBLE WASHED STONE 12' LEACHING FACILITY 6.17' NOTES 1. DATUM IS APPROTMATE N.G.V.D. 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE t LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR LOCUS MAP BOTTOM TH 1 EL. 67.0' J � DENNIS R•R. PONDr%� NOT TO SCALE 11. CONTRACTOR RESPONSIBLE FOR ALL EROSION CONTROL, LOCUS MID CAPE EXIT EROSION CONTROL NETTING REQUIRED ON ALL SLOPES >10% 7 HIGHWAY _ R T.6 t LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR LOCUS MAP BOTTOM TH 1 EL. 67.0' TO COMMENCEMENT OF WORK. NOT TO SCALE 11. CONTRACTOR RESPONSIBLE FOR ALL EROSION CONTROL, ASSESSORS MAP 94 PARCEL 3.1 EROSION CONTROL NETTING REQUIRED ON ALL SLOPES >10% LOCUS IS WITHIN FEMA FLOOD ZONE C SEPTIC DESIGN: MINIMUM YARD SETBACKS* GARBAGE DISPOSER IS NOT ALLOWED FRONT - 30 FT. SIDE - 20 FT. DESIGN FLOW: 4 BEDROOMS ®110 GPD = 440 GPD REAR - 20 FT. �k VERIFY NTH BUILDING DEPARTMENT USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 TEST HOLE LOGS USE A 1500 GAL. SEPTIC TANK ENGINEER: MICHAEL FARIA, SE LEACHING: SIDES: 2 (33.5 + 12.83) 2 (.74) = 137 GPD WITNESS: AMY VON HONE, RS _ I _ BOTTOM 33.5 x 12.83 (.74) = 318 GPD DATE: -1/10/00 TOTAL: 614 S.F. 455 GPD PERC. RATE _ < 2 MIN/INCH USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) CLASS SOILS WITH 4' STONE AT ENDS AND 4' AT SIDES 4 ELEV. ELEV. 4 ELEV. 4 0„ - 84.0' 0„ 84.0' 0„ - 82.0' 0/A 0/A 0/A - MA APPROVED DATE BOARD OF HEALTH UNSUIT. SL UNSUIT. SL UNSUIT. SL 10YR 3/1 10YR 3/1 10YR 3/1 8.. 8„ 4„ B B B UNSUIT. LS UNSUIT. LS UNSUIT. LS , 36' 10YR .5/6 81.0' 36,. OYR 5/6 81.0 10YR 5/6 18" 80.5' 1 FPAVEDI 111 .LOT 2A I DRIVE 1 \NT 67.0 I 1 55 J 1 r 181.38 6J - - - - - - - - - - - - - - - - 4 - - - EASEME \\�----------------------- LEGEND -----_7 LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - -100 -- EXISTING CONTOUR C1 C1 C1 UNSUIT. LS UNSUIT. LS UNSUIT. LS 2.5Y 6/4 2.5Y 6/4 84„ 2.5Y 6/4 168" 132" jl C2 C2 C2 I �I MS MS PERC MS 2.5Y 7/4 2.5Y 7/4 E 2.5Y 7/4 �1 204" 67_0' 180" 69.0' 156" 69.0' 1 - I NO GROUNDWATER ENCOUNTERED W(7 DATE T ` 3 E PLAN � �. i- II OF LOT 3A OLD HYANNIS ROAD YARMOUTH (PORT) MA PREPARED FOR SIDDHARTH DATE: MARCH 14, 2005 REV: JUNE 17, 2010 (REMOVAL) REV: APRIL 28, 2005 REV: MAY 15, 2005 REV: j v/rF14, 2010 Scale: 1"= 20' path Health Department o o zo 30 ao so FEET �-tlK l 74- \.r-�a - rrn off 508-362-4541 -" (%L� � .-xez4"�' � fax 508-362-9880 down cape. engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouthport, ma 02675 99-403 LOT 3A BASE.DWG