Loading...
HomeMy WebLinkAbout10 Old Hyannis Road - 07 - Cell Site Installation & DetailsSCALE: N.T.S. W:\SPRINT\7472\CAPECOD\73\RNA663C7.DWG 6/18/99 J.R.H. CELL SITE INSTALLATION NOTES: THE FOLLOWING INSTALLATION NOTES HAVE BEEN COMPILED FROM THE EXISTING PROJECT DOCUMENTS (I.E. PROJECT SPECIFICATIONS, SPRINT STANDARD PRACTICE, LUCENT DOCUMENTS, ETC.) FOR USE. THESE NOTES SHALL BE UTILIZED FOR THE CONSTRUCTION OF THE CELL SITES TO ENSURE COMPLIANCE WITH THE PROJECT DESIGN AND SPECIFICATION REQUIREMENTS. A. GROUNDING: 1. ALL METAL CONDUIT FOR GROUNDING DOWN CONDUCTORS SHALL BE BONDED TO THE GROUND SYSTEM AT BOTH ENDS. 2. GROUNDING CONDUCTORS SHALL BE CONNECTED TO THE MAIN WATER PIPE USING A BURNDY TYPE GAR -TC CLAMP. 3. KOPR-SHIELD ANTI -OXIDATION COMPOUND SHALL BE USED ON ALL GROUNDING CONNECTIONS. 4. ALL UNDERGROUND GROUNDING CONNECTIONS SHALL BE MADE BY THE CADWELD @PROCESS. 5. ALL CADWELDSOSHALL BE INSTALLED USING THE PROPER CONNECTION/MOLD AND MATERIALS FOR THE PARTICULAR CONNECTION AND/OR APPLICATION. TEE CONNECTIO SWEEP CONNECTION POST CONNECloc TKkI ANTENNA POST CADWELD II�CADWELD11 #2 AWG BCW /CAOWELD /2 AWG BCW 12 AWG ecw 6. ALL BOLTED GROUNDING CONNECTIONS SHALL BE INSTALLED WITH A 0K WASHER UNDER THE NUT. HARDWARE FOR BOLTED CONNECTIONS SHALL BE MINIMUM OF 3/8" DIAMETER AND SHALL BE STAINLESS STEEL. 7. GROUNDING WIRE SHALL NOT BE INSTALLED OR ROUTED THROUGH HOLES IN ANY METAL OBJECTS OR SUPPORTS TO PRECLUDE ESTABLISHING A "CHOKE" POINT. AWG BCW � nvr%E POINT (NOT ACCEPTABLE) 8. FERROUS METAL CLIPS WHICH COMPLETELY SURROUND THE GROUNDING CONDUCTOR SHALL NOT BE USED. CLIPS OF THE FOLLOWING MATERIALS AND TYPES MAY BE USED TO FASTEN AND SUPPORT GROUNDING CONDUCTORS. • PLASTIC CLIPS • METAL CLIPS WHICH DO NOT COMPLETELY SURROUND THE GROUNDING CONDUCTOR 9. STANDARD BUSS BARS (CIGBES AND MIGBS) SHALL BE FURNISHED AND INSTALLED. THEY SHALL NOT BE FABRICATED OR MODIFIED IN THE FIELD. 10. THE GROUNDING CONNECTION TO THE POWER AND TELCO CABINETS OF THE PPC SHALL BE MADE BY CONNECTING THE CONDUCTOR FROM THE GROUND RING TO THE FACTORY FURNISHED BUSS BAR IN EACH COMPARTMENT. 11. ALL GROUNDING WIRES SHALL BE INSTALLED WITHOUT LOOPS (PIGTAILS) AND SHARP BEND RADIUS. C CLOUGH, HARBOUR � A & ASSOCIATES LLP DRAWING COPYRIGHT ENGINEERS, SURVEYORS, PLANNERS © 1999 s LANDSCAPE ARCHITECTS 171 PARK AVENUE — WEST SPRINGFIELD, MA — 01090 P.O. BOX 626 413-746-0796 CHA Project No. 7472-73 I 5 B. ANTENNA COAXIAL CABLES (WAVEGUIDE) NOTE: THE RF TRANSMISSION LINE INSTALLED BETWEEN THE PRIMARY RADIO CABINET (PRC), FURNISHED BY LUCENT, AND THE ANTENNA CONSISTS OF A COAXIAL CABLE, SOMETIMES REFERRED TO AS A WAVEGUIDE. 1. ALL ANTENNA COAXIAL CABLES AND JUMPERS SHALL BE INSTALLED WITHOUT LOOPS AND/OR PIGTAILS. 2. ANTENNA COAXIAL CABLE GROUND KITS SHAfl.NOT BE INSTALLED ON THE JUMPER BETWEEN THE ANTENNA AND MAIN LINE CABLE. 3. ANTENNA COAXIAL CABLE GROUND KITS SHALL BE INSTALLED AS CLOSE TO THE CONNECTOR AS POSSIBLE IAT EACH ANTENNA. IF THIS IS NOT FEASIBLE THE GROUND .KIT SHALL BE INSTALLED IMMEDIATELY AFTER THE BEND ON THE FIRST STRAIGHT RUN OF CABLE. THE GROUND KIT SHALL BE INSTALLED ON STRAIGHT SECTION OF CABLE ONLY AND NOT ON BENDS. 4. ANTENNA COAXIAL CABLE SHALL BE INSTALLED TO COMPLY WITH THE MANUFACTURE'S MINIMUM BEND RADIUS SPECIFIED BELOW. THE CONTRACTOR SHALL INSTALL RACEWAY FOR COAXIAL CABLE USING THE PROPER FITTINGS NECESSARY TO ENSURE THAT THE MINIMUM BEND RADIUS REQUIREMENTS ARE MET. (REFERENCE: TECHNICAL INFORMATION BULLETIN NO. 96-026) COAXIAL CABLE MINIMUM BEND RADIUS MANUFACTURER CABLE TYPE CABLE SIZE (DIAMETER) MINIMUM BEND RADIUS IN TRAY MINIMUM BEND RADIUS IN 4" OR 6" CONDUIT CABLEWAVE FLC 12-50J 1/2" 5" 10" CABLEWAVE FLC 78-50J 7/8" 10" 18" CABLEWAVE FLC 114-50J 1 1/4" 15" 22" CABLEWAVE FLC 158-50J 1 5/8" 20" 28" 5. THE GPS ANTENNA COAXIAL CABLE SHALL BE,A CONTINUOUS CABLE RUN, FROM THE CONNECTOR AT THE ANTENNA HEAD TO THE CONNECTION AT THE BTS CABINET, WITHOUT JUMPERS. 6. THE ANTENNA COAXIAL CABLE AT THE BTS SHALL BE INSTALLED IN THE ANTENNA CABLE COVER ASSEMBLY (ACCA) IN ACCORDANCE WITH DETAIL 513. THE FINISHED ;.ANTENNA' CABLES (WITH CONNECTOR AND GROUND KIT INSTALLED) SHALL BE INSTALLED SO THAT THE END OF THE CONNECTOR PROTRUDES NO FARTHER THAN 12 INCHES INTO THE ACCA. 7.THE COAXIAL CABLE ENTRY HATCHPLATE ON THE REAR OF THE ACCA SHALL BE INSTALLED WITH THE SMALL 1/2" DIAMETER HOLES (FOR THE GPS ANTENNA AND GROUND WIRES) TO THE RIGHT (WHEN FACING THE ACCA FROM THE REAR OF THE PRC). 8.ALL ANTENNA COAXIAL CABLES SHALL BE MARKED AND TAGGED IN ACCORDANCE WITH THE REQUIREMENTS IN PROJECT SPECIFICATION G-002, SECTION 16000, PARAGRAPHS 36 AND 37. THE FIGURE TO THE RIGHT INDICATES AN EXAMPLE OF THE COLOR CODE MARKED ON THE COAXIAL CABLES. 9. SINCE THERE ARE A NUMBER OF DIFFERENT COAXIAL CABLE ENTRY HATCHPLATES THAT MAY BE SUPPLIED WITH THE ACCA, THE CONTRACTOR SHALL ORIENT THE COAXIAL ;CABLE ENTRANCE INTO THE ACCA IN ACCORDANCE WITH THE DIRECTION ISSUED BY EACH MTA. THE FIGURE SHOWN BELOW INDICATES THE PROPER ORIENTATION FOR THE COAXIAL CABLE ENTRANCE INTO THE ACCA. SPARE KNOCKOUTS (TYP TELCO RECEPTACLE (TYP.) HATCH PLATE/BOOT ON REAR OF ACCA YARMOUTH, PROSPECT HILL WATER TANK YARMOUTH WATER DEPT. OLD HYANNIS ROAD/ PROSPECT HILL YARMOUTH, MA. 02664 4 'Sprint Spectrum, LP —® CROSSROADS CORPORATE CENTER 1 INTERNATIONAL BOULEVARD, SUITE 800 MAHWAH, NEW JERSEY 07495 BOSTON MTA SITE NO.: BS23XC663B2 3 C_ EMERGENCY GENERATORS_ 1. THE GENERAC EMERGENCY GENERATORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS THAT ARE SHIPPED WITH THE UNITS. 2. THE START-UP OF THE GENERAC EMERGENCY GENERATOR SHALL BE PERFORMED BY CERTIFIED ELECTRICAL DISTRIBUTORS (CED) OR ANOTHER FACTORY AUTHORIZED AGENT. THE FIELD SHALL COORDINATE THIS EFFORT WITH TOM CARROLL OF CED [1-800-727-9119] TO ENSURE THAT THE SAFETY AND WARRANTY ISSUES ARE ADDRESSED. 0. ELECTRICAL: 1. THE ELECTRICAL RACEWAY INSTALLED FROM THE MINI -PPC TO THE PRIMARY RADIO CABINET, FURNISHED BY LUCENT, SHALL HAVE AN 1 1/4" MALE CONNECTOR/REDUCER FOR THE TIE TO THE ELECTRICAL FITTING ON THE CABINET. THIS MAY BE ACCOMPLISHED USING EITHER A 1 1/4" CONDUIT, 1 1/4" FLEXIBLE CONDUIT OR A 1 1/4" BUSHING. SPARE KNOCKOUTS (TYP.) i" DIA. COMMON PORT FOR COAX ;ABLE ENTRANCE INTO ACCA. ROUND LEAD EXIT PORT WITH GROMMET (TYP. OF 2) N0. I DATE SCALE N.T.S ISSUED FOR CONSTRUCTION ISSUED FOR RENEW REVISIONS DESIGNED B.R.B. GAMMA AZIMUTH KBK I KJW I JPS JRH KJW JPS BY CHK APP'D W J.R.H. oil 01 B2 BETA AZIMUTH A2 B1 ALPHA AZIMUTH Al = ALPHA FACE, RED (SINGLE STRIPE) RIGHT ANTENNA AS VIEWED WHILE LOOKING AT THE FACE OF THE ARRAY A2 = ALPHA FACE, RED/RED (DOUBLE STRIPE) LEFT ANTENNA AS VIEWED W fLE LOOKING AT THE FACE OF THE ARRAY E31 = BETA FACE, WHITE (SINGLE STRIPE) RIGHT ANTENNA AS VIEWED WHILE LOOKING AT THE FACE OF THE ARRAY 62 = BETA FACE, WHITE/WHITE (DOUBLE STRIPE) LEFT ANTENNA AS VIEWED WHILE LOOKING AT THE FACE OF THE ARRAY G1 = GAMMA FACE, BLUE (SINGLE STRIPE) RIGHT ANTENNA AS VIEWED WHILE LOOKING AT THE FACE OF THE ARRAY G2 = GAMMA FACE, BLUE/BLUE (DOUBLE STRIPE) LEFT ANTENNA AS VIEWED WHILE LOOKING AT THE FACE OF THE ARRAY AArSprint Spectrum, LP CELL SITE INSTALLATION NOTES JOB NO. DRAWING NUMBER REV RBA663C7 1 22 z 34 D SIZE,