Loading...
HomeMy WebLinkAbout10 Old Hyannis Road - 08 - Electrical PlanSCALE: 1-1 W:\SPRINT\7472\CAPECOD\73\RBM63E1.DWG 8/4/99 DR ELECTRICAL SERVICE NOTES: 1. CONTRACTOR SHALL VERIFY THAT EXISTING SERVICE, WITH THE ADDITION OF SPRINTS SERVICE SATISFIES SPARE CAPACITY REQUIREMENTS OF NEC. 2, DRAWING((S) DE S ECOMPLETED LBASED BEFORE UPON SHE UTILITY IISERVATOIONSNIES COULD CONFIRM THE SOURCE O TELEPHONE SYSTEM NOTES 1. TELCO CONDUIT SHALL BE INSTALLED TO ACCOMMODATE THE FUTURE USE OF FIBER OPTIC CABLE. 2. TELCO CONDUIT RUNS SHALL BE AS SPECIFIED AND HAVE A MINIMUM 12" RADIUS BENDS AND ELBOWS FROM PPC TO ACOA. 3. CONDUIT RUNS SHALL HAVE ONE 18"x18"x8" PULLBOX AFTER 270' OF BEND. 4. STRAIGHT RU(N)S SHALL HAVE A PULLBOX AFTER EACH 75'-0" OF STRAIGHT RUN. 5. CABL.�- NSTALL CABLE WITHOUTSPLIIR CEI(FROM BUILDINGDTERMINAL BOARD LTO PPC). LEAVE ONE 15'-0' OF SLACK CABLE AT EACH END. LABEL AS T-1" AT EACH END AND AT ALL PULL BOXES. 6. PROVIDE 4" DIAMETER, SCHEDULE 40, PVC CONDUIT WITH MINIMUM 3'-0" RADIUS SWEEPS AND ELBOWS FOR UNDERGROUND TELEPHONE CONDUIT INSTALLATIONS FROM TELEPHONE DEMARCATION TO PPC U.N.O. 7. INSTALL PULL ROPES IN ALL CONDUITS UNLESS NOTED OTHERWISE. GROUNDING SYSTEM NOTES 1. ALL GROUNDING CONNECTIONS, MADE THROUGHOUT THIS DRAWING SHALL BE MADE WITH THOMAS AND BETTS KOPR-SHIELD (TM OF JET LUBE INC.). THERE IS NO EQUIVALENT FOR THIS ANTI -OXIDATION COMPOUND. NO OTHER COMPOUND WILL BE ACCEPTED. COAT ALL WIRES BEFORE LUGGING. COAT ALL SURFACES BEFORE CONNECTING. 2. CONTRACTOR SHALL VERIFY THE ADEQUACY OF THE INSTALLED SYSTEM. CONTRACTOR SHALL CONDUCT "SITE RESISTANCE TO EARTH GROUNDING TESTING" PER SPRINT STANDARD 96104 - RELEASE 5. INSTALLED SYSTEM SHALL ACHIEVE A GROUND RESISTANCE OF LESS THAN 10 OHMS. 3. RECORD GROUND RESISTANCE TEST RESULTS ON SPRINT SPECTRUM "GROUND RESISTANCE TEST' FORM. 4. TEST SHALL BE WITNESSED BY SPRINT REPRESENTATIVE. OEM Et J SCALE: 1/4" ��=+=.....^— —`moi ,�`,,�"."''''�,.:,,�..� ..�`v-'.�``.• SEE ALSO 569-5 E4 soo GENERAL NOTE ® 17 E4 1. ALL MATERIALS SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE ATTACHED SPECIFICATIONS NO. G-001, "TECHNICAL SPECIFICATION FOR CONSTRUCTION" AND NO. G-002, "TECHNICAL SPECIRCATION FOR CONSTRUCTION OF ELECTRICAL AND GROUNDING SYSTEM". IN CASE OF A CONFLICT BETWEEN THE CONSTRUCTION SPECIFICATIONS AND THE DRAWINGS, THE DRAWINGS SHALL GOVERN. IN CASE OF A CONFLICT BETWEEN SSLP STANDARD PRACTICES AND EITHER THE CONSTRUCTION ,--, SPECIFICATIONS ON THE DRAWINGS, THE SSLP STANDARD PRACTICES SHALL GOVERN. 509 \•• k '•y'*„f TO LADDER” •\••� 1 SCALE: 3/8" = 1'-0" I O r-1-1 SITE PLAN — POWER TELEPHONE & PART GROUNDING 4 EQUIPMENT PLAN — POWE E1 SCALE: 1/16" = 1'-0" - E1 I SCALE: 1/8" = 1'-0" - LP ��CLOIUGH, HARBOUR YARMOUTH, PROSPECT HILL WATER TANK -A-Sprint Spectrum, & ASSOCIATES LLP ���CROSSROADS CORPORATE CENTER DRAWING COPYRIGHT.ENGINEERS, SURVEYORS, PLANNERS YARMOUTH WATER DEPT. 1 - INTERNATIONAL BOULEVARD, SUITE 800 C 1999 6 L-ANOSCAPE ARCHITECTS OLD HYANNIS ROAD/ PROSPECT HILL MAHWAH, NEW JERSEY 07495 171 PARK AVENUE - WEST SPRINGFIELD, MA - 01090 YARMOUTH, MA. 02664 BOSTON MTA P.O. BOX 626 413-746-0796 SITE NO.: BS23XC663B2 CHA Project No. 7472-73 F 4 3 I /449 ISSUED FOR CONSTRUCTION MCS CMM MSV /2;qs ISSUED FOR REVIEW OR CMM SLN N0. DATE REWSIONS BY CHK APP'D SCALE: AS NOTED DESIGNED: DR DRAWN: DR 2 LEGEND ® GROUND ROD ® WELL CASING ■ CADWELD TYPE CONNECTION • COMPRESSION TYPE CONNECTIQN Ti MIGB MIGB aO B METER SOCKET BY OTHERS METER BY UTILITY COMPANY ---- GROUNDING WIRE, #2 BCW U.N.O. - - - - UNDERGROUND ELECTRICAL/TELEPHONE BY UTILITY CO. -------------- INDICATES EXISTING EQUIPMENT' ® CODED DRAWING NOTE eXX DETAIL NUMBER DRAWING(S) NUMBER ABBREVIATIONS AWG AMERICAN WIRE GAUGE ACCA ANTENNA CABLE COVER ASSEMBLY BCW BARE COPPER WIRE BTS BASE TRANSMISSION SYSTEM CIGBE COAX ISOLATED GROUND BAR EXTERNAL Cu COPPER DWG DRAWING GPS GEOSTATIONARY POSITIONING SYSTEM GR GROWTH MIGB MASTER ISOLATION GROUND BAR MIGBE MASTER ISOLATION GROUND BAR EXTERIOR , PCS PERSONAL COMMUNICATION SERVICE PPC POWER PROTECTION CABINET PRC PRIMARY RADIO CABINET RGS RIGID GALVANIZED STEEL RWY RACEWAY SSLP SPRINT SPECTRUM LIMITED PARTNERSHIP TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE W/ WITH CODED DRAWING NOTES: OEXISTING UTILITY POLE WITH ELECTRIC SERVICE FOR 2DOA, 240/12OV, 10 AND TELEPHONE SOURCE. PROVIDE SERVICE LATERALS AS INDICATED. J 2" C. w/(3) #3/0. + #6 G O 2" RGS W/ (2) 6 -PAIR, #24 AWG SOLID CORE TELEPHONE CABLE. OPPC MINI. FURNISHED BY SSLP. COORDINATE STUB UP LOCATIONS WITH EQUIPMENT LAYOUT. O 11/4" RGS W/(3) #2 +#8G O ACCA FURNISHED BY SSLP. 7O POWER CABINET. FURNISHED BY SSLP. SO PRIMARY RADIO CABINET. FURNISHED BY SSLP. O CIGBE. 10 MIGB 11 FUTURE EQUIPMENT 12 CABLE TRAY. BOND EACH SECTION. 13 #2 SOLID TINNED BCW BURIED GROUND. RING. 14 BOND TO WATER TANK USING HIGH CAPACITY DISCHARGE METHOD. 15 4"C W/(3) 600KCM. 4'-0" METER BANK W.(1) 200A COMBINATION METER/CB SERVICE ENCLOSURE FOR SPRINT AND (1) 200A COMBINATION METER/CB 16 SERVICE ENCLOSURE FOR FUTURE CARRIER BY THIS CONTRACT. METER PAN BY THIS CONTRACT, METER BY UTILITY. COORDINATE INSTALLATION REQUIREMENTS WITH UTILITY. 17 WELL CASING AS PART OF THIS CONTRACT IS AN ADD/ALTERNATE ITEM TO BE DETERMINED AT TIME OF BUILDING. %V+Df�gcil: Sprint Spectrum, LP ELECTRICAL PLAN JOB N0. I DRAWING NUMBEI 7472.044.73 RBA663E1 22x3 328 E3 OEM Et J SCALE: 1/4" ��=+=.....^— —`moi ,�`,,�"."''''�,.:,,�..� ..�`v-'.�``.• SEE ALSO 569-5 E4 soo GENERAL NOTE ® 17 E4 1. ALL MATERIALS SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE ATTACHED SPECIFICATIONS NO. G-001, "TECHNICAL SPECIFICATION FOR CONSTRUCTION" AND NO. G-002, "TECHNICAL SPECIRCATION FOR CONSTRUCTION OF ELECTRICAL AND GROUNDING SYSTEM". IN CASE OF A CONFLICT BETWEEN THE CONSTRUCTION SPECIFICATIONS AND THE DRAWINGS, THE DRAWINGS SHALL GOVERN. IN CASE OF A CONFLICT BETWEEN SSLP STANDARD PRACTICES AND EITHER THE CONSTRUCTION ,--, SPECIFICATIONS ON THE DRAWINGS, THE SSLP STANDARD PRACTICES SHALL GOVERN. 509 \•• k '•y'*„f TO LADDER” •\••� 1 SCALE: 3/8" = 1'-0" I O r-1-1 SITE PLAN — POWER TELEPHONE & PART GROUNDING 4 EQUIPMENT PLAN — POWE E1 SCALE: 1/16" = 1'-0" - E1 I SCALE: 1/8" = 1'-0" - LP ��CLOIUGH, HARBOUR YARMOUTH, PROSPECT HILL WATER TANK -A-Sprint Spectrum, & ASSOCIATES LLP ���CROSSROADS CORPORATE CENTER DRAWING COPYRIGHT.ENGINEERS, SURVEYORS, PLANNERS YARMOUTH WATER DEPT. 1 - INTERNATIONAL BOULEVARD, SUITE 800 C 1999 6 L-ANOSCAPE ARCHITECTS OLD HYANNIS ROAD/ PROSPECT HILL MAHWAH, NEW JERSEY 07495 171 PARK AVENUE - WEST SPRINGFIELD, MA - 01090 YARMOUTH, MA. 02664 BOSTON MTA P.O. BOX 626 413-746-0796 SITE NO.: BS23XC663B2 CHA Project No. 7472-73 F 4 3 I /449 ISSUED FOR CONSTRUCTION MCS CMM MSV /2;qs ISSUED FOR REVIEW OR CMM SLN N0. DATE REWSIONS BY CHK APP'D SCALE: AS NOTED DESIGNED: DR DRAWN: DR 2 LEGEND ® GROUND ROD ® WELL CASING ■ CADWELD TYPE CONNECTION • COMPRESSION TYPE CONNECTIQN Ti MIGB MIGB aO B METER SOCKET BY OTHERS METER BY UTILITY COMPANY ---- GROUNDING WIRE, #2 BCW U.N.O. - - - - UNDERGROUND ELECTRICAL/TELEPHONE BY UTILITY CO. -------------- INDICATES EXISTING EQUIPMENT' ® CODED DRAWING NOTE eXX DETAIL NUMBER DRAWING(S) NUMBER ABBREVIATIONS AWG AMERICAN WIRE GAUGE ACCA ANTENNA CABLE COVER ASSEMBLY BCW BARE COPPER WIRE BTS BASE TRANSMISSION SYSTEM CIGBE COAX ISOLATED GROUND BAR EXTERNAL Cu COPPER DWG DRAWING GPS GEOSTATIONARY POSITIONING SYSTEM GR GROWTH MIGB MASTER ISOLATION GROUND BAR MIGBE MASTER ISOLATION GROUND BAR EXTERIOR , PCS PERSONAL COMMUNICATION SERVICE PPC POWER PROTECTION CABINET PRC PRIMARY RADIO CABINET RGS RIGID GALVANIZED STEEL RWY RACEWAY SSLP SPRINT SPECTRUM LIMITED PARTNERSHIP TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE W/ WITH CODED DRAWING NOTES: OEXISTING UTILITY POLE WITH ELECTRIC SERVICE FOR 2DOA, 240/12OV, 10 AND TELEPHONE SOURCE. PROVIDE SERVICE LATERALS AS INDICATED. J 2" C. w/(3) #3/0. + #6 G O 2" RGS W/ (2) 6 -PAIR, #24 AWG SOLID CORE TELEPHONE CABLE. OPPC MINI. FURNISHED BY SSLP. COORDINATE STUB UP LOCATIONS WITH EQUIPMENT LAYOUT. O 11/4" RGS W/(3) #2 +#8G O ACCA FURNISHED BY SSLP. 7O POWER CABINET. FURNISHED BY SSLP. SO PRIMARY RADIO CABINET. FURNISHED BY SSLP. O CIGBE. 10 MIGB 11 FUTURE EQUIPMENT 12 CABLE TRAY. BOND EACH SECTION. 13 #2 SOLID TINNED BCW BURIED GROUND. RING. 14 BOND TO WATER TANK USING HIGH CAPACITY DISCHARGE METHOD. 15 4"C W/(3) 600KCM. 4'-0" METER BANK W.(1) 200A COMBINATION METER/CB SERVICE ENCLOSURE FOR SPRINT AND (1) 200A COMBINATION METER/CB 16 SERVICE ENCLOSURE FOR FUTURE CARRIER BY THIS CONTRACT. METER PAN BY THIS CONTRACT, METER BY UTILITY. COORDINATE INSTALLATION REQUIREMENTS WITH UTILITY. 17 WELL CASING AS PART OF THIS CONTRACT IS AN ADD/ALTERNATE ITEM TO BE DETERMINED AT TIME OF BUILDING. %V+Df�gcil: Sprint Spectrum, LP ELECTRICAL PLAN JOB N0. I DRAWING NUMBEI 7472.044.73 RBA663E1 22x3