Loading...
HomeMy WebLinkAbout440 Higgins Crowell Road - One-Line Diagram' i z /i 574,200 W DC 1980 SUNTECH STP290-24/VD MODULES 180 SOURCE CIRCUITS OF 11 MODULES i 77 PV SOURCE CIRCUITS ARE WIRED IN PARALLEL USING: 15 COMBINERS 15 - 12 STRING 1 X12 CIRCUIT STRING COMBINER BOX WITH INTEGRAL DISC.SWITCH 2 ( TYP. OF 15) 2 15 DC INPUT TERMINATIONS 500 kW ADVANCED ENERGY TX INVERTER NEMA -3R 310-595 VDC MPPT INPUT VOLTAGE RANGE 480 VAC 30 OUTPUT VOLTAGE 608 AAC MAXIMUM PER PHASE OUTPUT CURRENT — INTEGRAL OUTPUT, 480 VAC 30 EXISTING UTILITY POLE UTILITY POLE MOUNTED PRIMA METERING #1 AND CUTOUTS 200A 600V DC 3P DISC. SWITCH FUSED 150A ( TYP. OF 5) 1 NONE . mon �. MEN E Ili MEMMEM OMMEN ME ®�!I MEN MER Omni fn Sig E PV SOURCE CIRCUITS ARE WIRED IN PARALLEL USING: 8 COMBINERS 3 - 12 STRING 4- 11 STRING 1- 10 STRING LFACILITY GROUNDING SYSTEM 8 DC INPUT TERMINATIONS INTEGRAL TRANSFORMER 250 KW ADVANCED ENERGY TX INVERTER NEMA -3R 295-595 VDC MPPT INPUT VOLTAGE RANGE 480 VAC 30 OUTPUT VOLTAGE 304 AAC MAXIMUM PER PHASE OUTPUT CURRENT — JJ y Y) y INTEGRAL -AC OUTPUT CONTACTOR :---- ,_ 4. SXZ 480 - 480/277V - h 75 kVA 4 GROUNDING J TRANSFORMER 250A C. B. WITH AUX CONTACT 800A 600V AC 3P DISC. SWITCH 3-800A CURRENT LIMITING FUSES 4 TRANSFORMER WITH INTEGRAL HIGH VOLTAGE SWITCH PRODUCTION METER, PROVIDE CT' S ON M SECONDARY SPADES OF TRANSFORMER UTILITY INTEGRAL FUSES ON TRANSFORMER PRI CUSTOMER X12 CIRCUIT STRING COMBINER BOX WITH INTEGRAL DISC.SWITCH 2 ( TYP. OF 8) P-1 INTEGRAL ❑ CIRCUIT BREAKER = INTEGRAL OUTPUT, 480 VAC 3¢ 3 5 480V 750kVA 0 5. 75%Z 23kV 3#1 AL I5kV SHIELDED CABLE 4'PVC TO RISER POLE WITH CUTOUTS. y y 3 200A 600V DC 3P DISC. SWITCH FUSED 150A ( TYP. OF 3) LFACILITY GROUNDING SYSTEM INTEGRAL TRANSFORMER AC 30A C. B. WITH INTACTOR AUX CONTACT 3. 12%Z ( 3) 3000VA 480 - 480/277V GROUNDING Y,- A TRANSFORMERS 400A 600V AC 3P DISC. SWITCH 3-400A CURRENT LIMITING FUSES OVERHEAD LINE FROM TRANSFORMER AREA OUT TO STREET GANG OPERATED 3 -POLE UTILITY AC DISCONNECT POLE MOUNTED LOAD BREAK SWITCH AND LIGHTNING ARRESTORS DAS WEATHER STATION INTERNET CONNECTION SITE CONDITIONS MAX AVG. TEMP: MIN RECORD TEMP: PV ARRAY CONFIGURATION MODULE MFR AND MODEL: MODULE QTY. MODULES PER SOURCE CIRCUIT: TOTAL SOURCE CIRCUITS: PV MODULE OUTPUT■ Voc: Voc (Temp Adjusted): I sc: Vmp: I mp: PV SOURCE CIRCUIT OUTPUT Voc I sc: Vmp I mp: *BASED ON MODULE PERFORMANCE AT STANDARD TEST CONDITIONS (STC) 37 C ' -24 C SUNTECH STP290-24/VD 2970 11 270 45.00 Vdc 56.25 Vdc 8. 42 Adc 35. 60 Vdc 8. 15 A 495.00 Vdc 8. 42 Adc 391.60 Vdc 8. 15 A TABLE 1: PHOTOVOLTAIC SYSTEM EQUIPMENT LIST ID DESCRIPTION O1 2#10 - TYPICAL - SEE NOTE #1 O2#1/0 AWG & 1#6 AWG GND - 11/2'C O3-600 KCMIL & 1#3 AWG GND,I/O AWG INV. GND -.4'C O(2) 3-600 KCMIL & 1#1/0 ANG GND, 1111/0 INV GND,(2) 4'C O(3) 3-600 KCMIL & 1#1/0 AWG GND, 1#1/0 INV GND,(3) 4'C ADJUST FINAL DESIGN TO MAINTAIN 1% VOLTAGE DROP NOTES. 1. ALL HOMERUN WIRES TO DC COMBINER BOXES ARE #10 AWG USE-2/RHW-2 DUAL RATED WIRES. ROUTED AS REQUIRED ON BACK SIDE OF MODULES AND RACKING SYSTEM 2. ALL CONDUCTORS ARE COPPER 90' -RATED 3. ALL EQUIPMENT TO BE LABELED PER NEC REQUIREMENTS 4. METER DATA IS CONNECTED TO DATA ACQUISITION SYSTEM THROUGH CAT -5 ETHERNET CONNECTION (NOT SHOWN) i 861,300 Watts DC 750 kW AC Solar Array GENERAL NOTES: - ALL DESIGNS ARE SUBJECT TO FINAL STRUCTURAL ANALYSIS AND CONSTRUCTION LAYOUT - ALL MOUNTINGS, INVERTERS AND RACKING SYSTEMS ARE SUBJECT TO CHANGE TO AN "OR EQUAL" MANUFACTURER IN ORDER TO ACCOMMODATE THE SUGGESTED CONSTRUCTION SCHEDULE 7 GENERAL REVISION 02-26-13 6 CHANGED INVERTERS TO AE 12-18-12 5 GENERAL REVISIONS 11-27-12 4 GENERAL REVISIONS 10-23-12 3 ADDED WEATHER STATION 10-12-12 2 GENERAL REVISION 07-31-12 1 GENERAL REVISION 02-08-12 REVISIONS: ASN Dl• �4 oy � Gw� Ftl'Rr.R `° BROADWAY ELECTRICAL CO, INC. 295FREEPORT STREET BOSTON, MA 02122 617-288-7900 FAX: 617-288-4169 email: bwy@broadelec.com OWNER: BROADWAY RENEWABLE STRATEGIES, LLC PROJECT: CVEC DENNIS-YARMOUTH SCHOOL DISTRICT MARGUERITE SMALL SCHOOL DRAWING TITLE: ONE -LINE DIAGRAM SCALE: NO SCALE A44 DRAWING NUMBER: JOB NO: NSTAR 2168 DATE: 10-28-11 PV -2 DRAWN BY: MJD CHECK BY: LAF SCALE: NO SCALE