HomeMy WebLinkAbout4 Orchid Lane - Site Plan 2II N ACCESS COVERS MUST.BE WITHIN 6" OF FINISH GRADE \FIRST EL TO / BE LEVEL 9" MINIMUM. 3' MAXIMUM COVER /02.75 I.7J 100.1 I 2 jll IRg[98.0 C.US 100.2T �� c 100.0 l I BAFFLE 3 OUTLET 2-500 GAL LEACHING CHAMBERS P D -BOX W/4' STONE AROUND. 12.8'r x 25.1 x 2'd 1500 GAL H-20 SEPTIC TANK 6" CRUSHED STONE OR H-20 COMPACTED BASE PROFILE: NOT TO SCALE INVERT ELEVATIONS: -` LOCUS LOCUS MAP DESIGN CRITERIA: DESIGN FLOW: 3 BEDROOMS AT 110 G.P.D. PER BEDROOM EQUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 200% - 660 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 MINIINCH SOIL TEXTURAL CLASS -.I EFFLUENT LOADING RATE - 0.74 GPDISF 330 GPD / 0.74 GPDISF - 446 S.F. REQUIRED PROVIDED: 2-500 GAL LEACHING CHAMBERS WI4' STONE AROUND. A-471 S.F. 471 S.F. x 0.74 - 348 G.P.D. SOIL TEST PIT DA TA e INDICATES 17 INDICATES PERCOLATION OBSERVED TEST GROUNDWATER TP #2 HORIZON INVERT AT BUILDING: 104.32 MIN 2" OF PEASTONE INVERT IN SEPTIC TANK: 103.0 OR FILTER FABRIC INVERT OUT SEPTIC TANK: 102.75 ------ INVERT IN DIST. BOX: 100.27 314" - 1 1/2" DIA. INVERT OUT DIST. SOX: 100.1 DOUBLE WASHED STONE INVERT IN LEACH CHAMBER: 100.0 52 " BOTTOM OF LEACH CHAMBER: 98.0 ...... 40------- ADJUSTED GROUND WATER: NIA MEDIUM OBSERVED GROUND WATER: NIA BOTTOM OF TEST HOLE #1: 91.0 -` LOCUS LOCUS MAP DESIGN CRITERIA: DESIGN FLOW: 3 BEDROOMS AT 110 G.P.D. PER BEDROOM EQUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 200% - 660 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 MINIINCH SOIL TEXTURAL CLASS -.I EFFLUENT LOADING RATE - 0.74 GPDISF 330 GPD / 0.74 GPDISF - 446 S.F. REQUIRED PROVIDED: 2-500 GAL LEACHING CHAMBERS WI4' STONE AROUND. A-471 S.F. 471 S.F. x 0.74 - 348 G.P.D. SOIL TEST PIT DA TA e INDICATES 17 INDICATES PERCOLATION OBSERVED TEST GROUNDWATER TP #2 HORIZON TP #1 TEXTURE COL OF •N .84 0� �� - ` FILL O 45" -------------------- - ------ OVER HEAD WIRES A FINE ..- UNDERGROUND ELECTRIC LINE -T- SAND 616 52 " ---------------- SPOT ELEVATION ...... 40------- EXISTING CONTOUR C i MEDIUM IOYR SAND 713 13' rEXIS/GNG 1 C I MEDIUM f l I! ! 1 1 I I TANK l W SAND 7/2 LU F-4 i i / 1 1 1 f ! I 1 !` f / BH 1 I 09.6 BM. CORNER v FL y II t 09. DECK � y /EXISJING iFOPOSED I ,D / SAS/ 1 _ ry+z EXISTING DWELL lNG � m O I / I f m 3d .2' I SHED TO BE N 98.97 I I i o, !(£MOVED /m W o SN 105.1 ON, CORNER STEP / I f IpI/ ITI>1 EL -l10.49 7 STONE WALL SOI REMO AL - SEE`NOTES 1 5. ..'..:� /-DR I WW \\ O l 4 sT�� --- 0 T _h7 L I2 m 1 11 \\^�� 4 `<-��^$92-f S.F. EXISTING STONE DRIVE a� ( 1.72' S9 40"W� >S-� \ \ \ -102.7`_- MULCH \ REUSE 2 EXISTING 500 GALLON LEACHING ' CHAMBERS W/NEW 4' STONE AROUND ORCHID LANE -` LOCUS LOCUS MAP DESIGN CRITERIA: DESIGN FLOW: 3 BEDROOMS AT 110 G.P.D. PER BEDROOM EQUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 200% - 660 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 MINIINCH SOIL TEXTURAL CLASS -.I EFFLUENT LOADING RATE - 0.74 GPDISF 330 GPD / 0.74 GPDISF - 446 S.F. REQUIRED PROVIDED: 2-500 GAL LEACHING CHAMBERS WI4' STONE AROUND. A-471 S.F. 471 S.F. x 0.74 - 348 G.P.D. SOIL TEST PIT DA TA e INDICATES 17 INDICATES PERCOLATION OBSERVED TEST GROUNDWATER TP #2 HORIZON TP #1 TEXTURE COL OF 0- FILL O 45" -------------------- - ------ OVER HEAD WIRES A FINE IOYR UNDERGROUND ELECTRIC LINE -T- SAND 616 52 " ---------------- SPOT ELEVATION ...... 40------- EXISTING CONTOUR C i MEDIUM IOYR SAND 713 72 103.0 0" HORIZON TEXIURL LVLUK 0 O 99.3 /" ------------- - ------ OVER HEAD WIRES A SANDY IOYR UNDERGROUND ELECTRIC LINE -T- LOAM 513 98.7 6' ---------------- SPOT ELEVATION ...... 40------- EXISTING CONTOUR 8 LOAMY IOYR SAND 616 13' C I MEDIUM IOYR SAND 7/2 NO WATER 1 91.0 144-1 DATE: JULY 27. 1999 TEST BY: STETSON HALL WITNESSED BY: KELDA WELSH PERC RATE: ( 2 MINIINCH LEGEND ® C8 CONCRETE BOUND -W- WATER LINE O HYDRANT -G- GAS LINE - OHW- OVER HEAD WIRES # LIGHT POST -£- UNDERGROUND ELECTRIC LINE -T- UNDERGROUND TELEPHONE LINE - CTV- UNDERGROUND CABLEVISION LINE -1- 40.4 SPOT ELEVATION ...... 40------- EXISTING CONTOUR P - PROPOSED CONTOUR Yarmouth Health Department ame D for 103.0 102.9 102.5 101.9 9/.0 GENERAL NOTES: 1. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED, FOR BENCH MARKS SET. SEE SITE PLAN. 3. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT, D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE lS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL -DIG-SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. ALL UNSUITABLE MATERIAL (FILL. A 6 8 HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. 9. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. 10. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. S I TE PLAN 'A SN "ISo OF F 4 ORCHID LANE. MAP JOHN PARCEL 52.2 Z. DEMAREST,JR. ,No. 36859 S I TE PLAN OF LAND 4 ORCHID LANE. MAP 55. PARCEL 52.2 WEST YARMOUTH. MA PREPARED F7O R : MATT CH/1 DS SCALE: I 20' NOVEMBER 13. 2012 REVISED: FEBRUARY 27. 2013 STEPHEN A. HAAS ENGINEERING, I N C 923 Route 6A Yormouthport MA. 02675 ( 508 ) 362-81.32 \1/ JOB NO: 07-097