HomeMy WebLinkAbout13 Route 6A - Sewage Disposal System Design RepairSOIL TEST PIT DATA: NOVEMBER 22, 2005 TEST PIT --ISL_ TEST PIT #2 GRD. EL. 105.6 GRD. EL. 96.5 EST. HIGH GW. N/A EST. HIGH GW. EST. HIGH GW. 96.5 EST. HIGH GW S10YRP5/3M B LOAMY SD 10YR 5?6N EL = 102.85 C-1 COARSE. SAND 2.5Y 6/6 MED SAND Imoc 2.5Y 7/4 loc EL = 96.85 BOG IRON SANDY LOAM NO G. WATER 144" EL = 93.6 VARIANCES REQUESTED: NONE: FLOOR PLANS: SEE ATTACHED: INVERT ELEVATIONS: .L = 86.5 120" TOP OF FOUNDATION DATE: 4" INVERT AT PIPE (LOWER) EL = 96.5 V 4" INVERT AT SEPTIC TANK (IN) DATE: 4" INVERT AT SEPTIC TANK (OUT) _11/22/05 r--------------; _ ; 11/22/05 21" TEST BY:I 4" INVERT AT DIST. BOX (OUT) A INVERTS AT LEACHING FACILITY: TEST BY: 4" INVERT AT BEGINNING BSC GROUP. INC. OF LEACHING FIELD SANDY LOAM 10YR 5/3 BREAKOUT ELEVATION BSC GROUP. INC. 4" INVERT AT END WITNESSED BY: OF LEACHING FIELD 102.00 K ELEVATION AT BOTTOM WITNESSED BY: 33" LYNN MULKEEN rB 96.5 M 21" LYNN MULKEEN WATERPROOF AT FACTORY PERC. RATE STRUCTION ACTIVITY WITH DIG -SAFE LOAMY Sf�ND 5'11' PERC. RATE 4'-0" PAIN. -2-_MIN./INCH ; 10YR 5/6 _MIN./INCH ? 96.5 SOIL EVALUATOR ; EL = 94.1 - 29" ISOIL EVALUATOR 49" C. FIELD 5 m o 0 LJ ------------------- 33" C. FIELD -�� BOTTOM 93.8 RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING EL = 93.8 PIPE THE CONTRACTOR PRIOR TO CONSTRUCTION `�coC:.--.i 8..: �eS .I .. . . - - � SOIL CLASS: REQUIRED. � a q 3 MERCURY FLOAT SOIL CLASS: 63" 1 PROJECT TITLE: CMED. 1 1/2' STONE 1 #13 SEWER BRICK AND MORTAR. FULL. OUTER jl BOT. EL = 93.50 SAND -• -• 3'r • • = ��� �� v -i, � • L.T.A.R. PREPARED FOR: 2.5Y 7/4 7 LARKIN LANE L.T.A.R. DATE: DECEMBER 30, 2005 0.74 G.P.D./SQ.FT. CHECK: M. DIBB DRAWN: K. HEALY FIELD: D.G. / J.McC. 0.74 G.P.D./SQ.FT. 105" SHEET 1 OF 1 JOB NO. 4-8901.00 117" FLOOR PLANS: SEE ATTACHED: INVERT ELEVATIONS: .L = 86.5 120" TOP OF FOUNDATION 100.80 A 4" INVERT AT PIPE (LOWER) 99.10 B 4" INVERT AT SEPTIC TANK (IN) 98.30 C 4" INVERT AT SEPTIC TANK (OUT) 98.05 D 4" INVERT AT PUMP CHAMBER (IN) 97.75 E 2" INVERT AT PUMP CHAMBER (OUT) 97.50 F 2" INVERT AT DIST. BOX (IN) 102.44 G 4" INVERT AT DIST. BOX (OUT) 102.27 H INVERTS AT LEACHING FACILITY: REQ'D EMERGENCY STORAGE = 440 GAL EMERGENCY STORAGE PROVO = 557 GAL 4'-10' NUMBER OF DOSING CYCLES = 4 PER DAY DEPTH PER CYCLE = 6 INCHES 5"x4' -4"x8' -0"x7.48 GAL/CF = 129 GAL/DOSE DESIGN TDH = 8 FEET 4" INVERT AT BEGINNING INV.=97.75 TANK OF LEACHING FIELD 102.13 J BREAKOUT ELEVATION 102.63 4" INVERT AT END 10% (MAX) BY WT. SHALL OF LEACHING FIELD 102.00 K ELEVATION AT BOTTOM e 3' OF LEACHING FIELD 101.50 L ADJUSTED GROUNDWATER 96.5 M HIGH GROUNDWATER COMPUTATION (BASED ON TP#1 INDICATES DEPTH TO WATER 2.4 INDEX WELL AIW-247 WATER LEVEL RANGE ZONE B CURRENT DEPTH6INDEX WELL(11/05) 23.2 WATER LEVEL ADJUSTMENT 2.5 DEPTH TO ADJUSTED HIGH WATER 0.0 INDICATES FM DOG INDICATES _ V ESTIMATED PERC. SEASONAL HIGH TEST GROUND WATER TOP EL. = 99.00 INDICATES ❑ �- OBSERVED INDICATES GROUND WATER UNSUITABLE MATERIAL SEPTIC TANK DETAIL: 1,500 GALLON H-10 WATERPROOF AT FACTORY BUOYANCY CALCULATION: BUOYANCE FORCE = 2.7 X 62.4 Ib/cf X 5.66' X 10.5' = 10,012 LBS WEIGHT OF TANK = 11,480 LBS WEIGHT OF SOIL = (1' X 5.66' X 10.5') X 85 Ib/cf = 5,070 LBS 11,480 LBS + 5,070 LBS = 16,550 LBS > 10,012 LBS - OK NOTES: 1. SEPTIC TANK SHALL BE STEEL REINFORCED CONCRETE. 2. SEPTIC TANK TO WITHSTAND H-10 LOADING 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 4. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. 5. INLET AND OUTLET TEES TO BE CAST IRON, SCHED. 40 PVC OR CAST -IN-PLACE CONCRETE. TEES TO BE CENTERED UNDER MANHOLE COVER. 10'-6' 10'-0" PRECAST SEPTIC TANK - O ` c 5'-2" IGW., 74.6 FIN. GR. EL. = 100-101 PLAN VIEW BOT. EL 72.7 NOT TO SCALE 2-21' DIA MANHOLE COVERS TO WITHIN TEE TO BE UNDER 6" OFF FINISH GRADE M.H. OPENING SEWAGE SRMER�IBLE TOP EL. = 99.00 _40 OF HEALTH REGULATIONS. APPROX. 24" COVER NOTES: RAISE M.H W L, �pVN' r3' 4" SEWER BRICK & MORTAR 0 +�" ., -' REQ'D EMERGENCY STORAGE = 440 GAL EMERGENCY STORAGE PROVO = 557 GAL 4'-10' NUMBER OF DOSING CYCLES = 4 PER DAY DEPTH PER CYCLE = 6 INCHES 5"x4' -4"x8' -0"x7.48 GAL/CF = 129 GAL/DOSE DESIGN TDH = 8 FEET PUMP CHAMBER TO WITHSTAND INV.=97.75 TANK NORMAL WATER LEVEL 12' SECURE CHAIN ` INV 98.3 H-10 LOADING 10% (MAX) BY WT. SHALL TEE TO WALL DISCHARGE e 3' PASS No. 200 ADJ. G.W. 96.5 10' 14' 3 WALLS PIPE INV 76.80 24" DIA MIN. WATERPROOF AT FACTORY INLET TEE STRUCTION ACTIVITY WITH DIG -SAFE Z8 5'11' EXISTING UTILITY SYSTEM IN SERVICE. 4'-0" PAIN. 80• BEND ON STATUTE CHAPTER 82, SECTION 409 4'-6' 5-8` ? 96.5 :e LIQUID DEPTH cns Tema) ` CONTRACTOR SHALL VERIFY SIZE, PUMP ON EL. = 95.3 AND STRUCTURES AS REQUIRED PRIOR 5 m o 0 LJ 2" SCH 80 PVC THREADED 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTIO14 SHALL BE WATERTIGHT. -�� BOTTOM 93.8 RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING 6"I w 5 mo PIPE THE CONTRACTOR PRIOR TO CONSTRUCTION `�coC:.--.i 8..: �eS .I .. . . - - � BOTTOM ON LEVEL STABLE BASE V:,g REQUIRED. � a q 3 MERCURY FLOAT 4. 3' s' MIN. 3/4" To�`�� PROJECT TITLE: CROSS-SECTION VIEWd�.� 1 1/2' STONE LEVEL CONTROLS #13 FIN. GR. EL. = 100-101 8'-0" 13.1-- DOSING CALCULATIONS: CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. SEWAGE SRMER�IBLE TOP EL. = 99.00 DESIGN FLOW TO CHAMBER = 440 GPD OF HEALTH REGULATIONS. APPROX. 24" COVER NOTES: PUMP POWER & FLOAT CONTROL CABLES FROM SEPTICS 4'-4" co OR EQUIVALENT REQ'D EMERGENCY STORAGE = 440 GAL EMERGENCY STORAGE PROVO = 557 GAL 4'-10' NUMBER OF DOSING CYCLES = 4 PER DAY DEPTH PER CYCLE = 6 INCHES 5"x4' -4"x8' -0"x7.48 GAL/CF = 129 GAL/DOSE DESIGN TDH = 8 FEET PUMP CHAMBER TO WITHSTAND INV.=97.75 TANK INLET SECURE CHAIN 2" PVC DESIGN GPM = 35 GPM H-10 LOADING 10% (MAX) BY WT. SHALL TEE TO WALL DISCHARGE <5 X OF No. 4 SIEVE SHALL PASS No. 200 ADJ. G.W. 96.5 i 3 WALLS PIPE INV 76.80 24" DIA MIN. WATERPROOF AT FACTORY C.I. MANHOLE COVER FIN. GR. EL. = 100-101 N-HYDROMAPUMP BROUGHT TO FINISH GRADE BOLT ON COVERS CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. SEWAGE SRMER�IBLE TOP EL. = 99.00 D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. APPROX. 24" COVER NOTES: 5. POWER CABLES TO BE PLACED IN FROM SEPTICS 1/2" STONE OR EQUIVALENT 1. PUMP CHAMBER TO WITHSTAND INV.=97.75 TANK SCALE SECURE CHAIN 2" PVC CONFORMING TO THE FOLLOWING H-10 LOADING 10% (MAX) BY WT. SHALL 35 GPM ® 8' TDH TO WALL DISCHARGE <5 X OF No. 4 SIEVE SHALL PASS No. 200 ADJ. G.W. 96.5 i ER. n a PIPE INV 76.80 2. WATERPROOF AT FACTORY ALARM ELEV.=95.6 STRUCTION ACTIVITY WITH DIG -SAFE STOR. ro or 2" GALV. UNION CHECK VALVE EXISTING UTILITY SYSTEM IN SERVICE. OR APPROVED. EQUAL. THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL 1-800-322-4844. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL " w LO ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, PUMP ON EL. = 95.3 AND STRUCTURES AS REQUIRED PRIOR 5 m o 0 LJ 2" SCH 80 PVC THREADED 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTIO14 SHALL BE WATERTIGHT. 4'-3" RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING 6"I w 5 mo PIPE THE CONTRACTOR PRIOR TO CONSTRUCTION 10. THE ENGINEER IS TO BE NOTIFIED OF PUMP OFF EL. = 94.8 REQUIRED. o w m q 3 MERCURY FLOAT 4. RAISE MANHO'.E TO FINISH GRADE WITH 508 778 8919 PROJECT TITLE: SEWAGE DISPOSAL 10 a V)'8 LEVEL CONTROLS #13 SEWER BRICK AND MORTAR. FULL. OUTER jl BOT. EL = 93.50 MASSACHUSETTS -• -• 3'r • • = ��� �� v -i, � • MORTAR PARCE TO PROVIDE WATER ISTRIBUTION BOX DETAIL: NOT TO SCALE NO. OF OUTLETS : 5 FINISHED GRADE REMOVABLE -- I- 2" WALLS COVER 2' INLET IEE T T Pic B,wwEN 15 1/2' TEE t T 115" I PRECAST DISI 6' 5.5' OUTLETS ;. 8" 1 1 BOX b910� 9bd, ��d 09epgj4 L1`7BOTTOM ON LEVEL 44\ 2- 1 7 1 71 /2 STABLE BASE 6" MIN. 3/4' TO PLAN SFW CROSS-SECTION 1 1/2' Cf1USHED STONE BASET •----------_i ------------ NOTES: 1. DIST. BOX TO WITHSTAND H-10 LOADING UNLESS UNDER PAVEMENT, DRIVES OR TRAVELED WAYS WHEREIN H-20 LOADING SHALL APPLY. 2. PROVIDE INLET TEE OR BAFFLE WHERE SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR IN PUMPED SYSTEM. 3. FIRST TWO FEET OF PIPE OUT OF DIST. BOX TO BE LAID LEVEL. 4. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. TT ROAD LEACHING FIELD DETAIL: NOT TO SCALE 36" MAX .COVER FINISHED GRADE 4" - H ALLE ROUTE, 6A --------- ----------------------- _ -------- ---------- ----- -- _ \ /_� _- OHW- ---OHW 04W JHw -�" = otiw �W 109.26'._ --- OHw OHW r IN85'56 40 ` II r- ` of / T, J O v6% OF MARK O. DIc B .[� I / CIVIL No.45937 TPS � I rl I �97_ � _ _ // N �b S Is !e� 46 Al MINIMUM 2% CROSS SLOPE _ CAP ENDS � 4�' �ba�4e e�K6YaCo�o(BOOe ST_G 0v:v Z$ e \ 6' DEPTH a4Ri"G�ii"e•�•e�e♦e♦oae oC*A . , `� 4 �. \30 " LEVEL BOTTOM \ EACH SIDE PROFILE 36' MAX. - 12' MIN. COVER 2% MIN. FINISH GRADE 4" MIN. LOAM & SEED LOAM & SEED DISTURBED AREAS 5MI �5' MIN 6' 6.qA bo e •Nep l' �2" MIN. OF 1/13- TO S�`d ; :gyp• ; :-P�,;P�s b ;( 1/2" WASHED STONE I^ . _T 4' 1 4' -j 3/4" TO 1-1/2' CROSS-SECTION DOUBLE WASHED STONE (NO FINES) DESIGN CRITERIA: DESIGN FLOW: 4 BEDROOMS AT110G.P.B./D 440 G.P.D. REQUIRED SEPTIC TANK: 440 X 200% = 880 GAL. SEPTIC TANK PROVIDED: = 1500 GAL. SIZE OF LEACHING FACILITY REQUIRED: DESIGN PERC. RATE: <2 MIN./ INCH C14` PROPOSED POST & // l _ 98, LONG TERM APPL. RATE 0,74 G.P.D/S. F. `O RAIL FENCE TO PROTECT- �\ NEW SEPTIC TANK/ II SIZE OF LEACHING FACILITY PROVIDED: C 1 r I / r / \99` 440 GPD 0,74 SF/GPD = 595 S.F. USE LEACHING FIELD _ /� f ti 04 �\�� \POROPOSEDALLON `\�99 1 �� PROPOSE DXWELLII G '� N BOTTOM = 20' x 30' = 600 S.F ry PUMP A�1BER ADD, N INV ICO \ 1107` d I REL w �^91 I 600 S.F X 0.74 SF/GPD = 444 GPD 100 \4 Z \X 102.9 �' d / 99.5 NOTE: ROOOSE' -��� D C_ I/ I ALL EXISTING LOCUS INFORMATION 2 x 30, -// I i� SEPTIC COMPONENTS LEAC G FIE- `` \ . / OPOSED/l I °' TO BE REMOVED CURRENT OWNER: FRANK B. GOUDEY . \\. _ 2 CAR / ( DO FROM SITE IN PROPOSE D\ GARAG I ACCORDANCE WITH TITLE REFERENCE: DEED BOOK 7172 PAGE 291 1500 GALLON SEPTIC TANK �•- X \ a1 \ \ lu< \ \ \ \ N CC) X 10 4\\ TITLE 5. �p / PROPOSEDCa�'\, PLAN REFERENCE: PLAN BOOK 553, PAGE 21 BREEZEWA MAP 112 PARCEL 22 Alf"! NGvF• .• ASSESSORS MAP: 112 (TOWN WATER) 5,� pA PARCEL: 25.1 EXISTING j `� 38039 J BA G 48' RESIDENTIAL ZONE: R-40 erg 6'39,52.W ��'' SETBACKS: FRONT 30' '►� - SIDE 20' \�� \\ \` \\ �"ear \ x , 1 - 109.1 �7pg\\\ X 1047 1, o \\ \ l \ I I MAP 112 109.9 \\ �\ \ \ \ ] PARCEL 25.2 (TOWN WATER) 107. \ \ \ ] r ! 1;59.80, \ \\ + I W I � LOCUS PLAN: NO SCALE 9 �o 9� N 9L \ 6A ALOCUS 2 ��u19�30G 9,� y m PROFILE: NOT TO SCALE: MANHOLE COVERS AS REQUIRED (BRING TO WITHIN 6" OF FINISH GRADE) r-4" PVC SCH 40 I=n REAR 20' 2.13 MINIMUM LOT SIZE: 40,000 S.F. EXISTING LOT SIZE: 40,044± S.F. io 3 GROUNDWATER N OVERLAY DISTRICT: NOT A ZONE II a p >n FLOOD ZONE: C. PANEL #250015 0003 C BENCHMARK PLAN VIEW DATUM: VERTICAL DATUM: TOP OF CONCRETE SCALE: 1' = 20 FEET ASSUMED BOUND. ELEVATION;I BENCH MARK SET: 100.07 ASSUMED 0 10 20 40 TOP OF CONCRETE BOUND. EL = 100.07 NOTE: CONCRETE COVERS TO WITHIN ADD 2" TEE AT END OF FORCE MAIN 6" TO FINISH GRADE FIRST PIPE LENGTH TO BE SET LEVEL FOR MIN. 2' FINISH GRADE EL 105. ELEVATION 103.5 1,500 GALON1,000 GALLON PRECAST CONCRETE PRECAST CONCRETE SEPTIC TANK PUMP CHAMBER 6' STONE BASE 4" PVC I=J LEACHING FIELD / M pW JAS./ BOT ELEV = L - - , 5' -SEPARATION ` I=F ;- SAND FILL, SEEs' STONE BASE ADJUSTED NOTES 5 & 6 GROUNDWATER = M 93.50 000 GALLON H-10 PUMP CHAMBER: BUOYANCE FORCE _ (3.0') X 62.4 Ib/cf X 4.8' X 8.5' = 7,637 LBS WEIGHT OF TANK = 8,240 LBS WEIGHT OF SOIL = (1' X 5.3' X 9') X 85 Ib/cf = 4,054 LBS 8,240 LBS + 4,054 LBS = 12,294 LBS > 7,637LBS - OK REVISIONS N-HYDROMAPUMP TIGHT SEAL. 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. SEWAGE SRMER�IBLE MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT (MODEL MYERS) 5. POWER CABLES TO BE PLACED IN 6" MIN. 3/4" TO 1 1/2" STONE OR EQUIVALENT CONDUIT IN ACCORDANCE WITH LOCAL NOT TO SCALE LOCATED UNDER MH BUILDING AND WIRE CODES. CONFORMING TO THE FOLLOWING SIEVE ANALYSIS: 10% (MAX) BY WT. SHALL 35 GPM ® 8' TDH <10 % OF No. 4 SIEVE SHALL ISTRIBUTION BOX DETAIL: NOT TO SCALE NO. OF OUTLETS : 5 FINISHED GRADE REMOVABLE -- I- 2" WALLS COVER 2' INLET IEE T T Pic B,wwEN 15 1/2' TEE t T 115" I PRECAST DISI 6' 5.5' OUTLETS ;. 8" 1 1 BOX b910� 9bd, ��d 09epgj4 L1`7BOTTOM ON LEVEL 44\ 2- 1 7 1 71 /2 STABLE BASE 6" MIN. 3/4' TO PLAN SFW CROSS-SECTION 1 1/2' Cf1USHED STONE BASET •----------_i ------------ NOTES: 1. DIST. BOX TO WITHSTAND H-10 LOADING UNLESS UNDER PAVEMENT, DRIVES OR TRAVELED WAYS WHEREIN H-20 LOADING SHALL APPLY. 2. PROVIDE INLET TEE OR BAFFLE WHERE SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR IN PUMPED SYSTEM. 3. FIRST TWO FEET OF PIPE OUT OF DIST. BOX TO BE LAID LEVEL. 4. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. TT ROAD LEACHING FIELD DETAIL: NOT TO SCALE 36" MAX .COVER FINISHED GRADE 4" - H ALLE ROUTE, 6A --------- ----------------------- _ -------- ---------- ----- -- _ \ /_� _- OHW- ---OHW 04W JHw -�" = otiw �W 109.26'._ --- OHw OHW r IN85'56 40 ` II r- ` of / T, J O v6% OF MARK O. DIc B .[� I / CIVIL No.45937 TPS � I rl I �97_ � _ _ // N �b S Is !e� 46 Al MINIMUM 2% CROSS SLOPE _ CAP ENDS � 4�' �ba�4e e�K6YaCo�o(BOOe ST_G 0v:v Z$ e \ 6' DEPTH a4Ri"G�ii"e•�•e�e♦e♦oae oC*A . , `� 4 �. \30 " LEVEL BOTTOM \ EACH SIDE PROFILE 36' MAX. - 12' MIN. COVER 2% MIN. FINISH GRADE 4" MIN. LOAM & SEED LOAM & SEED DISTURBED AREAS 5MI �5' MIN 6' 6.qA bo e •Nep l' �2" MIN. OF 1/13- TO S�`d ; :gyp• ; :-P�,;P�s b ;( 1/2" WASHED STONE I^ . _T 4' 1 4' -j 3/4" TO 1-1/2' CROSS-SECTION DOUBLE WASHED STONE (NO FINES) DESIGN CRITERIA: DESIGN FLOW: 4 BEDROOMS AT110G.P.B./D 440 G.P.D. REQUIRED SEPTIC TANK: 440 X 200% = 880 GAL. SEPTIC TANK PROVIDED: = 1500 GAL. SIZE OF LEACHING FACILITY REQUIRED: DESIGN PERC. RATE: <2 MIN./ INCH C14` PROPOSED POST & // l _ 98, LONG TERM APPL. RATE 0,74 G.P.D/S. F. `O RAIL FENCE TO PROTECT- �\ NEW SEPTIC TANK/ II SIZE OF LEACHING FACILITY PROVIDED: C 1 r I / r / \99` 440 GPD 0,74 SF/GPD = 595 S.F. USE LEACHING FIELD _ /� f ti 04 �\�� \POROPOSEDALLON `\�99 1 �� PROPOSE DXWELLII G '� N BOTTOM = 20' x 30' = 600 S.F ry PUMP A�1BER ADD, N INV ICO \ 1107` d I REL w �^91 I 600 S.F X 0.74 SF/GPD = 444 GPD 100 \4 Z \X 102.9 �' d / 99.5 NOTE: ROOOSE' -��� D C_ I/ I ALL EXISTING LOCUS INFORMATION 2 x 30, -// I i� SEPTIC COMPONENTS LEAC G FIE- `` \ . / OPOSED/l I °' TO BE REMOVED CURRENT OWNER: FRANK B. GOUDEY . \\. _ 2 CAR / ( DO FROM SITE IN PROPOSE D\ GARAG I ACCORDANCE WITH TITLE REFERENCE: DEED BOOK 7172 PAGE 291 1500 GALLON SEPTIC TANK �•- X \ a1 \ \ lu< \ \ \ \ N CC) X 10 4\\ TITLE 5. �p / PROPOSEDCa�'\, PLAN REFERENCE: PLAN BOOK 553, PAGE 21 BREEZEWA MAP 112 PARCEL 22 Alf"! NGvF• .• ASSESSORS MAP: 112 (TOWN WATER) 5,� pA PARCEL: 25.1 EXISTING j `� 38039 J BA G 48' RESIDENTIAL ZONE: R-40 erg 6'39,52.W ��'' SETBACKS: FRONT 30' '►� - SIDE 20' \�� \\ \` \\ �"ear \ x , 1 - 109.1 �7pg\\\ X 1047 1, o \\ \ l \ I I MAP 112 109.9 \\ �\ \ \ \ ] PARCEL 25.2 (TOWN WATER) 107. \ \ \ ] r ! 1;59.80, \ \\ + I W I � LOCUS PLAN: NO SCALE 9 �o 9� N 9L \ 6A ALOCUS 2 ��u19�30G 9,� y m PROFILE: NOT TO SCALE: MANHOLE COVERS AS REQUIRED (BRING TO WITHIN 6" OF FINISH GRADE) r-4" PVC SCH 40 I=n REAR 20' 2.13 MINIMUM LOT SIZE: 40,000 S.F. EXISTING LOT SIZE: 40,044± S.F. io 3 GROUNDWATER N OVERLAY DISTRICT: NOT A ZONE II a p >n FLOOD ZONE: C. PANEL #250015 0003 C BENCHMARK PLAN VIEW DATUM: VERTICAL DATUM: TOP OF CONCRETE SCALE: 1' = 20 FEET ASSUMED BOUND. ELEVATION;I BENCH MARK SET: 100.07 ASSUMED 0 10 20 40 TOP OF CONCRETE BOUND. EL = 100.07 NOTE: CONCRETE COVERS TO WITHIN ADD 2" TEE AT END OF FORCE MAIN 6" TO FINISH GRADE FIRST PIPE LENGTH TO BE SET LEVEL FOR MIN. 2' FINISH GRADE EL 105. ELEVATION 103.5 1,500 GALON1,000 GALLON PRECAST CONCRETE PRECAST CONCRETE SEPTIC TANK PUMP CHAMBER 6' STONE BASE 4" PVC I=J LEACHING FIELD / M pW JAS./ BOT ELEV = L - - , 5' -SEPARATION ` I=F ;- SAND FILL, SEEs' STONE BASE ADJUSTED NOTES 5 & 6 GROUNDWATER = M 93.50 000 GALLON H-10 PUMP CHAMBER: BUOYANCE FORCE _ (3.0') X 62.4 Ib/cf X 4.8' X 8.5' = 7,637 LBS WEIGHT OF TANK = 8,240 LBS WEIGHT OF SOIL = (1' X 5.3' X 9') X 85 Ib/cf = 4,054 LBS 8,240 LBS + 4,054 LBS = 12,294 LBS > 7,637LBS - OK REVISIONS NO. DATE DESCRIPTION GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL 6. REPLACE WITH CLEAN WASHED SAND OR OTHER CLEAN GRANULAR SOILS CONFORMING TO THE FOLLOWING SIEVE ANALYSIS: 10% (MAX) BY WT. SHALL PASS No. 50 SIEVE <10 % OF No. 4 SIEVE SHALL PASS No. 100 <5 X OF No. 4 SIEVE SHALL PASS No. 200 UNIFORMITY COEFFICIENT 0 No. 4 SIEVE </=6.0 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL 1-800-322-4844. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THE START OF CONSTRUCTION. 8. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACILITY. 9. EXISTING INVERTS ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION 10. THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANCES THAT MAY BE REQUIRED. w "ci' ; (t U lul RD 657 Main Street, Unit 6 W. Yarmouth Massachusetts 02673 508 778 8919 PROJECT TITLE: SEWAGE DISPOSAL SYSTEM DESIGN REPAIR #13 ROUTE 6A YARMOUTH PORT MASSACHUSETTS ��� �� v -i, � • X006 Lit PREPARED FOR: Mr. FRANK GOUDEY 7 LARKIN LANE HARWICH, MA 02645 DATE: DECEMBER 30, 2005 COMP. DESIGN: K. HEALY CHECK: M. DIBB DRAWN: K. HEALY FIELD: D.G. / J.McC. FILE NO. 8901-SEP.DWG DWG NO. 5265-05 SHEET 1 OF 1 JOB NO. 4-8901.00