Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 1998i WEST YARMMTK MA PLAN REFERENCE CONTOURS 0 a PLAN BOOK 238 PAGE I EXISTING - - - - - - - 20 JACKSON ASSESSOR'S MAP: 46 FINAL 1`21 STREET LOT: 145 FINAL SPOT GRADE X 20.5 IN 0 W i LOCUS—i;- p� LINCOLN AV s W N I8 ELNOTOCUS-MAP 64ftx7ftx6in ft 20 TO SCALE LEACH FIELD 120,0 o SOIL REMOVAL AREA 21 D -BOX EXISTIN W O 20 St LEACH LD F- Q c o j EXISTING D -BOX\ zo - { cv = J o �' 40 ML I st ° RELOCATED \ 0 U _u 0 \ POLY 1000 GALLON W LL �' L W m SEPTIC TANK w �; o �` 01 �a X ° G�3C c�C�MC D m �o� Q J Lo^ o o o Z IOOOT GAL ON �, JAN 0 6 1999 G "� C5 DRAW h w� SEPTIC TA O rn c� 22 �ZZ O HEALTH DEPT. �+gz G> 3 �- PR OSEI \ Z X o ' A TION > u O APROPOS \ cp wn LL Lo v ins ` ADDITIO W c Lr' DRV I® t0 LOT .5Q N pRN�. c „ BENCH MARK AREA - Is.655 sr +- ' 2 �� 22 TOP OF CONCRETE BOUND 0?+- ELEVATION - 20.10 +- �- _ rr r'=r USGS DATUM ASSUMED CV I� , 366-,�--rt 'pP�Np ETENTION m 98.175 f y � i&� Icy �2 let * z WATEI44 ' Y UTILITY L ,,, z Lp W -j Q POLE LL a \�� Q ENCLOSURE O (1m _ v pRA1NAGE SITE & SEWAGE DISPOSAL SYSTEM PLAN lY Z N I,Go X LL Q PL N I FOR PROPOSED ADDITION TO EXISTING DWELLING Ix o LU F- \' b OV> SCALE.- in -30 ft°f MR. STEVE WRIGHTINGTON Z� - ROBERT to 94 COOLIDGE ROAD WEST YARMOUTH. MA ° M LL ci cv i No. 89x2 ECO -TECH ENVIRONMENTAL O l 9Fs�srER�° 4 43 TRIANGLE CIRCLE SANDWICH MA 02563 � J cU'o `= � qyo yo w `� — RAE ETE-435 APRIL 19. 1995 112 ' """"� ' S A DRAFT PLAN UNLESS IT THIS PLAN IS TO BE CONSIDERED BEARS THE STAMP AND SIGNATURE OF THE DESIGN ENGINEER ORIGINAL PLANS INTENDED FOR SUBMITTAL TO THE BOARD OF HEALTH WILL BE SIGNED IN BLUE AND STAMPED IN RED. TEST: SOIL TEST LOG SOILEEOVA UA OR: DAVID"D5 CIOUGHANOWR. RS WITNESSED BY: BRUCE MURPHY. HEALTH AGENT TEST BORING I ELEVATION - 19.97 •- GROUNDWATER ENCOUNTERED AT 65 in PARENT MATERIAL: PROGLACIAL OUTWASH PERC RATE: 2 MIN/INCH IN C SOILS DEPTH (INCHES) SOIL HORIZON USDA SOIL TEXTURE SOL COLOR (MUNISELL) SOL MOTTLING OTHER 0-4 0 WOOD LOAM 7.5 YR 25/2 NOPE FRIABLE 4-6 E LOAMY SAND 10 YR 3/I NOME FRIABLE 6-11 A LOAMY SAND 7.5 YR 3/3 NONE FRIABLE 1 F3 B LOAMT SAND 10 YR 4/6 NOPE LOOSE 32-85 C COARSE SAND 10 YR 5/6 NONE LOOSE. 20*4 GRAVEL GROUNDWATER ADJUSTME NT (FRIMPTER METHOD) I .OBSERVED GROUNDWATER LEVEL: 14.55 =. 1ND_E WELL: AIW-230 - ZONE E READING: MARCH. 1998 LEVEL: 20.8 ADJUSTMENT: 0.5 ESTIMATED HIGH GROUNDWATER LEVEL: 15.05 LEACHING FIELD DETAIL -NOT TO SCALE DISTRIBUTION LINES TO SLOPE AT .005 ft PER ft DISTRIBUTION LINES TO BE SCH 40 PERFORATED PIPE CAP ENDS OF PIPE 41 64 ft DESIGN CALCULATIONS DESIGN FLOW: 3 BEDROOMS X 110 GPD - 330 GPD SEPTIC TANK: 330 GPD X 2 DAYS - 660 GALLONS USE EXISTING 1000 GALLON SEPTIC TANK DISTRIBUTION BOX: USE 3 OUTLET D -BOX SOIL ABSORBTION SYSTEM: A 64 ft x 7 ft x 6 in LEACHING FIELD CAN LEACH Abot - (64 x 7 ) - 448 sf V 0.74 x 448 - 331.5 GPD USE A 64 f t x 7 f t x 6 in FIELD. Vt - 331.5 GPD > 330 GPD REQUIRED NOTES 1) GARBAGE GRINDER NOT ALLOWED WITH THIS DESIGN 2) ALL LINES TO BE SCH 40 PVC AND PITCH AT 1/8 INCH PER FOOT MINIMUM. 3) ALL COMPONENTS INSTALLED SHALL MEET THE MINIMUM REQUIREMENTS OF MASSACHUSETTS TITLE 5 SEPTIC CODE (310 CMR 15) 4) INSTALLER TO VERIFY LOCATIONS OF ALL UNDERGROUND UTILITIES BEFORE EXCAVATING FOR SYSTEM. TELEPHONE LINE TO BE REROUTED AWAY FROM SYSTEM 5) EXISTING LEACH FIELD TO BE ABANDONED IN PLACE 6) ALL STONE TO BE DOUBLE WASHED AND FREE OF IRON. FINES AND DUST IN PLACE 7) LINES EXITING D -BOX TO RUN LEVEL FOR 2'-0' BEFORE PITCHING DOWN 8) ECO -TECH ENVIRONMENTAL RECOMMENDS THE INSTALLATION OF LOW FLOW FIXTURES AND APPLIANCES, AND BIANNUAL PUMPING OF THE SEPTIC TANK 9) SYSTEM IS NOT DESIGNED TO WITHSTAND VEHICULAR LOADING. DO NOT PARK OR DRIVE VEHICLES OVER SEPTIC SYSTEM. 10) INSTALLER TO OBTAIN DISPOSAL WORKS PERMIT BEFORE STARTING WORK. 11) SEPTIC TANKS SHALL BE INSTALLED LEVEL AND TRUE TO GRADE ON A LEVEL STABLE BASE THAT HAS BEEN MECHANICALLY COMPACTED AND ON TO WHICH SIX INCHES OF CRUSHED STONE HAS BEEN PLACED TO MINIMIZE UNEVEN SETTLING 12) UNSUITABLE SOILS ENCOUNTERED WITHIN THE SOIL REMOVAL AREA ARE TO BE REMOVED DOWN TO THE MEDIUM SAND STRATUM AND REPLACED WITH CLEAN MEDIUM SAND COMPACTED IN PLACE TO MINIMIZE SETTLING 13) EXISTING SEPTIC TANK TO BE PUMPED AND MOVED TO LEVEL AND POSITION SPECIFIED. INTERIOR PLUMBING TO BE MODIFIED IN SUCH A MANNER SO AS TO PERMIT A NEW BUILDING SEWER TO BE INSTALLED AT LEVEL AND POSITION INDICATED. 14) 40 MIL POLY LINER TO BE INSTALLED OS SHOWN ON PLAN.