HomeMy WebLinkAboutReview Checklistt �� � Z� - � � �e ; - TOWN OF YARMOUTH ✓`���'� , � SEWAGE PLAN REVIEW CHECKLIST ���' � ����� I • Location: A.M. �/� Lot �?' � Zone af Contribution: In Out_ Acrea.ge �`��.1�"Zv � � � �i � � Commercial: Residential: �.� ; Street: � Village: Floor Plan: #Bedrooms: � Owner: Installer: � � Address: Phone: I � Phone: i Builder: Engineer: � Address: Phone: 7 �- Phone: __ � � C� ,::,L' , � N/A YES NO ' 1.R uired#of co ies received 2.Date of soils exam and ercolation test not older than 2 ears 3.4-5 ft of na.tura occurtin ervious material, above water table 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from s tic com onents Var.: 6.Benchmark indicated and shown-NGVD if near wetlands 7. S tic tank minimum 10 ft from founda.tion, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L/ 9.Leachin minimum 1UO ft from wetlands Var.: • . ' 10.Leaching minimum 150 ft from drinkin welU25 ft irri tion well Var.: 11.Tank/leaching minimum 10 ft from r erry line Var.: i 12.S stem meets all other setback r uirements Vaz.: ' 13.Uses ad'ustment for maximum hi groundwater Var.: 14.Leachin set 4-5 ft above ad'.water or bottom of test hole Var.: 15.System not in to or subsoil(A,B horizons)or 5'removal ' 16.Pro sed contours are suita.ble ; 17. S stem meets slo e r irements-min. 1/8", '/a" referred �/ 18. System meets breakout r irements PVC liner: Wall: �.1 � 19. Specified tee sizes are roper, as baffle on outlet tee �/ 20. Sewa e is under 10,000 d for arcel � 21.No arba e dis osa.l � " 22. S stem ad uatel sized for its intended use 23.Minimum 6"stone or com acted below tank and dbox �i , 24.Manhole covers within 6"of grade, um cha.mber cover to ade , 25.Ins ection ort on lastic chambers/leach field 26.Electrica.l ermit for um chamber/S arate meter for du lexes . 27.Pum s stem-2"line,wee hole,check valve,tee in dbox, um size ' 28.S tic tank/ um chamber to be factory wat roofed 29.Vent rovided if leaching below 3 feet,under drivewa / arkin _/ ' 30.Buoyanc calculations for tank/pump chamber 31.En ' eer to ins ect and cert' soils: wall: commercial: 32.Engineer/Re `stered Sanitarian and Land Surv or stam s/signature ' 33.H-201oadin is sub'ect to vehicular traff'c, oundwater �,.� � 34.Title V A lication and ermit fee, install�si ture a 35.Foundation footin min.2 feet above ad'usted ound water for new house _ t---�' 36.Deed Restriction r uired max: #badrooms: `� . flow: -��� `/ 37.Check area lots for oundwater/Label oundwater in.Assessor's Ma < ' Plan reviewed by: �� c,o3�o3