Loading...
HomeMy WebLinkAbout173 Route 6A - Site Plan 3MAXIMUM FEASIBLE COMPLIANCE APPROVALS REQUESTED: 1. VARY SEPARATION TO HIGH GROUNDWATER BY V (4' PROVIDED). LEGEND 310 CMR 15.212. TH 1 TEST HOLE LOCATION, NUMBER 2993 -W- WATER LINE MARKINGS 9.5 x 8,7 EXIST. & PROP. ELEV. ('X' MARKS POINT) ,,-6--- EXISTING CONTOUR TB #1 (SEE B. YOUNG PLAN) -BOX L V R PROPOSED CONTOUR JOB NO. Y02-36 v v (APRIL 2002) NOTES COLLINS4.DWG `a ® DEPTH (inches) ELEV.(feet) 1. LOCUS IS A.M. 122, PARCEL 120. RTE 0 32.0 Bondy loam 2. ELEVATIONS SHOWN ARE ASSIGNED. at all bends H-20 1000 GAL. PUMP CHAMBER It 3aa 3. LOCUS IS IN FLOOD ZONE C ON FIRM DATED JULY 2, 1992. USE METAL COVERS WITH GRATE AND FRAME OVER PUMP AND SEPTIC TANK OUTLET. I- v 24'• _loamy -_- 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) (RTE �� sand 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. 0 1 iron silty clay___ 6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. -------- 24.0 48" _ loom- 7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14". NOT TO ,6 J 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW SCALE / a ON 28" DESIGN CAPACITY: 338 GPD D EXIT PIPES TO BE / OFF 24„ P -g- PROPOSED CONTOUR <D DESIGN DATA 5.9 pri Zone B of ln'daded) E EL FO FIRST TWO FEET. / ® EXISTING DRAINAGE CATCH BASIN 72" Use Thrust Blocks - -- 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. LEACH AREA at all bends H-20 1000 GAL. PUMP CHAMBER , 3aa USE METAL COVERS WITH GRATE AND FRAME OVER PUMP AND SEPTIC TANK OUTLET. WITH 4' OF STONE ON SIDES AND 2'± x - FENCE (IF SHOWN, NOT ALL SHOWN) `C �� (RTE 9" cover 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, LOCATION MAP 0 TREE (IF SHOWN, NOT ALL SHOWN) DEEP LEACH AREA. 9B" -------- 24.0 N Rn., ,6 J med. sand CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. O J WATER SERVICE RUNS } FROM HERETO` C� w H F - 5jqA:12W ) (� 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING t 4$ tat 72" r v TRC 120" IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 Pea, 210 J a hef j` T 13. PUMP AND FILL ANY EXISTING CESSPOOLS. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN y� I wafer ' LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) 374. 30< W 144^ ------_- 14. ALL CONSTRUCTION TO MEET TITLE S AND LOCAL REGULATIONS. 34.8 A layer 10yr 4/4 sandy loam B layer 10yr 5/6 sandy loom Cl layer 10yr 5/6 sandy loom C2 layer 10yr 7/2 med. fine sand (107 gravel) no water o l CM l" p 615 to RR TEST HOLE DATE: August 28, 2002 0 fxlst. Pov ;� 3a 14 Spike Fna _ .3a PERFORMED BY: Ron Cadillac, Soil Evaluator 14" 4.1z � I / WITNESSED BY: Amy Von Hone, RS, CHO 33.46 60 341 3.91 / �^ MAKE GRADE CHANGES PERC RATE: <2'-00"/inch (C2 layer) 73'1 Z SHOWN OVER LEACHING SOIL SUR Carver loamy coarse sand 36" Stan �'8 Q CD GEOLOGIC MAP(1986): Cape Cod Bay lake deposits 7z'i Ek�$rING F 3a Q Invert 30.70± eU4plNG a / Ltl 0)7 Exist. Cast Iron Invert 30.15 32J N0, 77 / ALARM &PUMP NOTES Use Gas Baffle 5 HIGH CAPACITY 56" I ShOded 3 H-20 overt 31.75 INFILTRATORS 0 '7814 SF o h l Proposed Provide ••a- x Q 1. ALARM TO BE WIRED BY ELECTRICIAN ON S=1 /2" 9" cover see detail 322 80 lC) V J 5 �3 Q 32.4 I 1 Z Stone Q I 1 a AREA=2C BENCHMARK --TOP SPIKE i Shaded Area SET=31.26 ASSIGNED 0 30.9 (4'3 OFF CORNER SHED) U' a a CID 01 i 29 /> ao,, 29.1 BENCHMARK --TOP SPIKE 29.1 SET=30.00 ASSIGNED (BEAN POLE WITNESS) 9.0 29, 1 1 129.2 at 1 3' DEEP IMPERVIOUS 2 2 2. 1 29 BARRIER --65 L.F. OF 1- , ° �'<' PEASTONE=32.2,GRADE 29.7 as "+C ABOVE BARRIER=32.8 MIN 3p4 C Y4 BARRIER IS STIFF 30 4 17'*& OBTAINABLE FROM 1� MILLER ENVIRONMENTAL 508-697-3710. 30.3 TN to N 2 031 ....:..::.:_ 39.0 p pNACO N/F N. NpEL S C.B.l,. GRA Y 0 "'"" / SEPARATE CIRCUIT FROM PUMP. Vent 0, TOP PEA STONE Z / 2. ELECTRICAL WORK TO BE INSPECTED BY Proposed z u1 Invert 30.40 P aD / ' WIRING INSPECTOR. 1500 Go' Proposed _ _ _ _ 32.8 324 J s J 3. ALARM TO BE LOCATED IN HOUSE. Sanitary 10 1/4" 5 2'4 �53T 4. PUMP TO BE CAPABLE OF PASSING Bottom 25.65 Tee T 160" Stone 'Q :; 5 Ct/ 1-1/4" SOLIDS AND INSTALLED IN STRICT Proposed overt 31.92 Invert 31.75 30.9 Metal gratosed P CONFORMANCE WITH MANUFACTURER'S 6" Stone or compact Proposed 4.0 Bottom O 7� P P Pro osed & tramem J SPECIFICATIONS. I p to /grade W f : Q 5. USE MEYER MW50, 1/2 HP PUMP, OR r7 L 7 r-4 1 1200' ro QEI 26.9 1.7Z\� EQUIVALENT, CAPABLE OF PUMPING Bottom TH1=18.3 AIW 247--A ;l 02 190±S.F. 44 GPM @ 23 TDH. <D DESIGN DATA 5.9 pri Zone B of ln'daded) RETAIL SPACE: 4600± S.F. Water 0 21.0 (April, 2002) 1.3 .a [Attic +. Basement + list Floor + 2nd Floor] 31. ss Use Thrust Blocks - -- [600 s. f. + 1200 s.f + 7800 s.f + 7000 s.f] LEACH AREA at all bends H-20 1000 GAL. PUMP CHAMBER GARBAGE GRINDER: No .. USE 5 HIGH CAPACITY INFILTRATORS REQUIRED CAPACITY: 250 GPD WITH 4' OF STONE ON SIDES AND 2'± 7 DRILL 3/8" WEEP/VENT HOLE SEPTIC TANK: 1500 GAL. OF STONE ON THE ENDS, FOR A 9" cover BOTTOM LEACHING AREA: 379 SF 35' LONG BY 10'-10" WIDE BY 10 1/4" 7TH i, Etne [(35' X 10.83')] DEEP LEACH AREA. 2 SIDE LEACHING AREA: 77.9 SF 5' REMOVAL J Invert 30.07 CHECK VALVE ALARM 32' [2(10.83'+ 35') X 0.85' DEEP)] / a ON 28" DESIGN CAPACITY: 338 GPD DO 5' ALL AROUND AND UNDER REMOVAL / OFF 24„ P [(379 SF + 77.9 SF) X .74 GPD/SFj DOWN 4' TO 8' TO MED. FINE SAND. o PUMP CHAMBER STORAGE CAPACITY: 370 GAL, BUOYANCY CALCULATIONS 1500 GAL. H-10 a' a... Bottom 25.32 6" STONE UNDER DOSES PER DAY: (USING 250 GPD) 4 0 / y WEIGHT OF EMPTY SEPTIC TANK AND 9" OF COVER f y TANK= 10.615 TON (PER SHOREY) o BUOYANCY CALCULATIONS -PUMP CHAMBER 9" COVER=.75' X 6.17' X 11' X 0.055 TON/CU. FT. w P ^ WEIGHT OF EMPTY CHAMBER AND 9" OF COVER 9" COVER=2.80 TON o CHAMBER= 7.25 TON (PER SHOREY) TOTAL= 10.615 TON + 2.80 TON = 13.41 TON a m 9" COVER= 0.75' X 5.25' X 9' X 0.055 TON/CU. FT. WEIGHT OF WATER --HIGH GROUNDWATER DOWN m ^ (26.9 -25.65) X 6.17' X 11' X 0.0312 TON/CU. FT. s SEE "PROPOSED DRAINAGE PLAN 9" COVER 25 T TON TOTAL= 7.25 TON + 1.95 70N = 9.20 TON WEIGHT WATER= 2.65 TON n 173 RT 6A, YARMOUTHPORT, MA" WEIGHT OF WATER --HIGH GROUNDWATER DOWN TANK AND 9" COVER ARE HEAVIER BY 10.7 TON. v DATED 5/22/02 X 5.2 9 X 0.0312 TON/CU. FT. (26GHT BERNARD J. YOUNG, PE TX WEIBY WATER O TANK AND 12" COVER ARE HEAVIER BY 6.8 TON, J � THIS PLAN IS A VALID COPY ONLY IF IT BEARS Q AN ORIGINAL RED STAMP AND SIGNATURE. N OF �C v a\ a,uorn; S &c N "'O , ��is0` RONALD ��m�> �� RONALD ��° 'o JA S (��io JAMES �1M HEALTH AGENT APPROVAL DATE 30.1 21.5 1 SITE PLAN FOR ROBERT F. & JUDITH M, COLLINS 173 HALLET ROAD (RTE 6A), YARMOUTH(PORT), MA SEPTEMBER 18, 2002 SCALE: 1"=30' RONALD J. CADILLAC, PLS, RS PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 (508) 775-9700 2002 BY R.J. CADILLAC PAGE 1 OF 1