HomeMy WebLinkAbout173 Route 6A - Site Plan 5MAXIMUM FEASIBLE COMPLIANCE APPROVALS REQUESTED: TB #1 (SEE B. YOUNG PLAN
(APRIL 2002)
1. VARY SEPARATION TO HIGH GROUNDWATER BY 1' (4' PROVIDED). DEPTH (inches) ELEV.(feet)
LEGEND 310 CMR 15.212. 0 32.0
S
loam
TH 1 TEST HOLE LOCATION, NUMBER 24" _loamy
29e3 sand
-W- WATER LINE MARKINGS iron
9.5 x 8,7 EXIST. & PROP. ELEV. ('X' MARKS POINT) �� soty cloy
EXISTING CONTOUR da" _loom____
_g- - PROPOSED CONTOUR
® EXISTING DRAINAGE CATCH BASIN
- x - FENCE (IF SHOWN, NOT ALL SHOWN)
0 TREE (IF SHOWN, NOT ALL SHOWN)
N gn.
BENCHMARK --TOP SPIKE
SET=31.26 ASSIGNED
(4'3" OFF CORNER SHED)
WATER SERVICE RUNS
FROM HERE TO STREET
BENCHMARK --TOP SPIKE
SET=30.00 ASSIGNED 1
(BEAN POLE WITNESS)
3' DEEP IMPERVIOUS
3.91
BARRIER --65 L.F. OF
32.4 /
40 MIL POLYETHYLENE
CHANGES
(MILLER BREAKOUT**)
PERC RATE:
TOP BARRIER=TOP
Stone
PEASTONE=32.2,GRADE
29'7
ABOVE BARRIER=328 MIN
O /�
** BARRIER IS STIFF
30,
& OBTAINABLE FROM
SOIL SURVEY(1993):
MILLER ENVIRONMENTAL
36"
508-697-3710.
'
N
29.1
30.4
30.3 T TH
32.7
33.47 72,E
(RTE 6q) 24.0
med. sand
SjSzW
45 to 72• raP STREET 120'---------
7-
-�--�-
h
e( N >q. water
61• 3.30^W 144..
3 --121.0
61.$- to
fxlsi �39a / 'n M U RR SPI
PaV 34 14 /M ~ kp Fnd.� .39
4
T\\34
32.4 11
' Stone
IREA=20,8
(Shaded Area NI
30.9
1
129.2
1
`777
::.� 39.0
DpNA�D N/F ,
y' & NpE�S C.B.d
GRA Y
> JOB NO. Y02-36
NOTES COLUNS4.DWG
1. LOCUS IS A.M. 122, PARCEL 120.
2. ELEVATIONS SHOWN ARE ASSIGNED.
3. LOCUS IS IN FLOOD ZONE C ON FIRM DATED JULY 2, 1992.
4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED)
5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER.
6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED.
7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14".
8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW
D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET.
9. DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED.
USE METAL COVERS WITH GRATE AND FRAME OVER PUMP AND SEPTIC TANK OUTLET.
10, STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP.
11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND,
CONTACT THE BOARD OF HEALTH, OR R.J. 'CADILLAC.
12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING
IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3).
13. PUMP AND FILL ANY EXISTING CESSPOOLS. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN
LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT.
14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS.
TEST HOLE DATE: August 28, 2002
PERFORMED BY: Ron Cadillac, Soil Evaluator
WITNESSED BY A V H RS CHO
NOT TO
SCALE
I LOCATION MAP I
TEST HOLE 1
DEPTH (inches) ELEV.(feet)
0 A layer 10yr 4/4 34.8
14" sandy loam
B layer 10yr 5/6
sandy loam
Cl layer 10yr 5/6
sandy loam
C2 layer 10yr 7/2
med. fine sand
(10% gravel)
no water
4.
-
3.91
WIRING INSPECTOR.
32.4 /
MAKE GRADE
CHANGES
S
PERC RATE:
my on one,
<2'-00"/inch (C2 layer)
Stone
as
341
?
O /�
SHOWN OVER
LEACHING
Water ® 21.0 (April, 2002)
SOIL SURVEY(1993):
Carver loamy coarse sand
36"
5. USE MEYER MW50, 1/2 HP PUMP, OR
4e
Q C�
EQUIVALENT, CAPABLE OF PUMPING'
I±S.F.
SEPTIC TANK: 1500 GAL.
44 GPM @ 23' TDH.
GEOLOGIC MAP(1986):
Cape Cod Bay lake deposits
[(35' X 10.83')]
31 5
Use Thrust Blocks
at bends
-
-
Invert 30.70±
H-20 1000 GAL. PUMP CHAMBER
1
DOWN 4' TO 8' TO MED. FINE SAND.
[(379 SF + 77.9 SF) x .74 GPD/SF]
e(Jf�DI
G
_ o'
a
L j CD'
9" cover
Te
Exist. Cast
Iron
Invert 30.15
5 HIGH CAPACITY
2" Cine
NO
Invert
30.07 ALARM 32" CHECK VALVE
a
FT. WEIGHT WATER --HIGH GROUNDWATER DOWN
ON 28"
(26.9 2 X X 11' X 0.0312 TON/CU. FT.
Use Gas Baffle
OFF 24" P
56"
��
Sh 3
odad
`7g14
/ 4r
m
ALARM &PUMP NOTES
25.32 6" STONE UNDER
N ,
H-20
TANK AND 12" COVER ARE HEAVIER BY 6.8 TON.
Invert 31.75 INFILTRATORS
Proposed
u
SF °
o
1.
ALAR M TO BE WIRED BY
ELECTRICIAN ON "
S=1 /2"/ft
9" cover
see detail
32.2 Provide
80 "o -
SEPARATE CIRCUIT FROM
PUMP.
vent
TOP PEA STONE
z
0
Zroposed
f / 2.
ELECTRICAL WORK TO BE
INSPECTED BY
i Invert 30.40
1500
P
140
1-7
Gal.
1
32.8 / 2
t/J
WIRING INSPECTOR.
32.4 /
31.7530.9
3. ALARM TO BE LOCATED IN HOUSE.
PASSING
S
TL 7' -4'1
4. PUMP TO BE CAPABLE OF
Stone
5
1-1/4" SOLIDS AND INSTALLED IN STRICT
-Metol grate .`
:
O /�
CONFORMANCE WITH MANUFACTURER'S
t frame -`
Water ® 21.0 (April, 2002)
SPECIFICATIONS.
i grade(
zi
Q
5. USE MEYER MW50, 1/2 HP PUMP, OR
1.7
Z\�
EQUIVALENT, CAPABLE OF PUMPING'
I±S.F.
SEPTIC TANK: 1500 GAL.
44 GPM @ 23' TDH.
ndl d)
35' LONG BY 10'-10" WIDE BY 10 1/4"
[(35' X 10.83')]
31 5
Use Thrust Blocks
at bends
-
-
all
H-20 1000 GAL. PUMP CHAMBER
1
DOWN 4' TO 8' TO MED. FINE SAND.
[(379 SF + 77.9 SF) x .74 GPD/SF]
DRILL 3/8" WEEP/VENT HOLE
PUMP CHAMBER STORAGE CAPACITY: 370 GAL.
BUOYANCY CALCULATIONS 1500 GAL. H-10
9" cover
Te
TANK= 10.615 TON (PER
BUOYANCY CALCULATIONS -PUMP CHAMBER
11' X 0)
9" COVER=.75' X 6.17' X 11' X 0.055 TON/CU. FT.
2" Cine
9„ COVER -2.80 TON
Invert
30.07 ALARM 32" CHECK VALVE
a
FT. WEIGHT WATER --HIGH GROUNDWATER DOWN
ON 28"
(26.9 2 X X 11' X 0.0312 TON/CU. FT.
9" COVER=1.95 TON
OFF 24" P
TOTAL= 7.25 TON + 1.95 TON = 9.20 TON
TANK AND 9" COVEERR ARE HEAVIER BY 10.7 TON, '
WEIGHT OF WATER --HIGH GROUNDWATER DOWN
m 0
r e
Bottom
25.32 6" STONE UNDER
N ,
TANK AND 12" COVER ARE HEAVIER BY 6.8 TON.
�.` S 2 J L j0)
e
SEE "PROPOSED DRAINAGE PLAN
173 RT 6A, YARMOUTHPORT, MA"
DATED 5/22/02
BY BERNARD J. YOUNG, PE
THIS PLAN IS A VALID COPY ONLY IF IT BEARS
AN ORIGINAL RED STAMP AND SIGNATURE.
HEALTH AGENT APPROVAL DATE
I
Proposed
� Sanitary 10 1/4"
(Bottom 25.65
Tee T 160"
Proposed Invert 31.92 Invert
31.7530.9
6" Stone or compact Proposed
Proposed 4.0' Bottom
TL 7' -4'1
N -O I EI 26.9
1 12001
I-
CD Bottom TH1=18.3
'DESIGN DATA
m 5.9' AIW 247 --April 02
Zone B
RETAIL SPACE: 4600± S.F.
Water ® 21.0 (April, 2002)
[Attic + Basement + 1st Floor + 2nd Floor]
LEACH AREA
[600 s.f. + 1200 s.f + 1800 s.f + 1000 s.f]
GARBAGE GRINDER: No
USE 5 HIGH CAPACITY INFILTRATORS
REQUIRED CAPACITY: 250 GPD
WITH 4' OF STONE ON SIDES AND 2'±
SEPTIC TANK: 1500 GAL.
OF STONE ON THE ENDS, FOR A
BOTTOM LEACHING AREA: 379 SF
35' LONG BY 10'-10" WIDE BY 10 1/4"
[(35' X 10.83')]
DEEP LEACH AREA.
SIDE LEACHING AREA: 77.9 SF
55' REMOVAL
[2(10.83'+ 35') X 0.85' DEEP)]
DO 5' ALL AROUND AND UNDER REMOVAL
DESIGN CAPACITY: 338 GPD
DOWN 4' TO 8' TO MED. FINE SAND.
[(379 SF + 77.9 SF) x .74 GPD/SF]
PUMP CHAMBER STORAGE CAPACITY: 370 GAL.
BUOYANCY CALCULATIONS 1500 GAL. H-10
DOSES PER DAY: (USING 250 GPD) 4
WEIGHT OF EMPTY SEPTIC TANK AND 9" OF COVER
TANK= 10.615 TON (PER
BUOYANCY CALCULATIONS -PUMP CHAMBER
11' X 0)
9" COVER=.75' X 6.17' X 11' X 0.055 TON/CU. FT.
WEIGHT OF EMPTY CHAMBER AND 9" OF COVER
9„ COVER -2.80 TON
CHAMBER= 7.25 TON (PER SHOREY)
TOTAL= 10.615 TON + 2.80 TON = 13.41 TON
9" COVER= 0.75' X 5.25' X 9' X 0.055 TON/CU.
FT. WEIGHT WATER --HIGH GROUNDWATER DOWN
(26.9 2 X X 11' X 0.0312 TON/CU. FT.
9" COVER=1.95 TON
TATE) .65
WEIGHT WATER= TON
TOTAL= 7.25 TON + 1.95 TON = 9.20 TON
TANK AND 9" COVEERR ARE HEAVIER BY 10.7 TON, '
WEIGHT OF WATER --HIGH GROUNDWATER DOWN
(26.9 -25.32) X 5.25' X 9' X 0.0312 TON/CU.
FT.
WEIGHT WATER= 2.33 TON
TANK AND 12" COVER ARE HEAVIER BY 6.8 TON.
�.` S 2 J L j0)
30.1
21.5
SITE PLAN FOR
ROBERT F. & JUDITH M. COLLINS
173 HALLET ROAD (RTE 6A), YARMOUTH(PORT), MA
SEPTEMBER 18, 2002 SCALE: 1"=301
RONALD J. CADILLAC, PLS, RS
PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN
P.O. BOX 258
WEST YARMOUTH, MA 02673
(508) 775-9700
2002 BY R.J. CADILLAC
PAGE 1 OF 1