HomeMy WebLinkAbout91.12 - Proposed Septic Designr BENCHMARK TOP OF FOUNDATION 20 FT. MINIMUM FROM CELLAR ELEV. I. I r�2r 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE _ CLEAN SAND :(ASSUMED) CONCRETE COVERS 4' SCHEDULE 40 PVC PIPE LOAM AND SEED MIN. PITCH 1/8' PER FT. 2' LAYER OF t 4 1/hF 1/2- LEGEND: 4' CAST IRON PIPE "- VENT EXISTING SPOT ELEVATION DOxO (OR EQUAL) MINIMUM NOT REQUIRED EXISTING CONTOUR ----00---- PITCH 1/4' PER FT. ? 1 CU. FT. OF FINAL SPOT EVA710N 0 . CONCRETE FINAL CONTOUUR SOIL TEST LOCATION FLOW LINE j j ito, ANCHOR UTILITY POLE -o- j%, 10' TOWN WATER—W--ow--W E1EV.a.✓,� "'{MIN. o wj j 2,0. . • € ?�.. ° CATCH BASIN (®N 4 t l LEVEL Y . e 10' O ELEV.: 3 GAS LINE C �- ELEV. GAS LIEN. y 6' SUMP ELEV. _ .. . « .�a _�..... CLEAN OUT C - BAFFLE CESSPOOL C.P. DISTRIBUTION LIQUID OUTLET j BOX Q HIGH CAPACITY EI N jTRATORS WTH 4 FEET 14 INCHES TFF (TO BE PLACED ON FIRM BASE) TO BE WATER TESTED x V' 2 S FEET 14 INCHES k lbY TRENCH FORMATION > IF MORE THAN ONE OUTLET i FEET 24 1NCHHEs 1500 GALLON (TO BE PLACED ON FIRM BASE) SOIL ABSORPTION tit WELL r�ftr 8 FEET 34 INCHES SEPTIC TANK 3/4• TO 1 1/2'I DDC WASHED STONE SYSTEM (SAS) ADJUST SEWAGE DISPOSAL SYSTEM PROFILE uses PROBABLE WATER TABLE ELEV. m NOT TO SCALE OBSERVm WATER TABLE ( TEST / ELEV. BOTTOM OFF TlSHOLE ELEV. - !i Gk k �I l k f. j-I��V 1% f !s' 7 Y r . Z1>JG , £< SOIL TEST DATE OF SOIL TEST 19, I9SR SOIL TEST DONE BY SWEETSER ENGINEERING WITNESSED BY R.. r v t rx,lt OBSERVATION HOLE 1 ELEv.s PERCOLATION RATE L n MIN./INCH AT '/ „ INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER n" PROJECT LOCATION /Q r�!lt 3 7)I' I 'Ir So() yrW P-1 oEJ7 N . I18" r)LL DATE /o`!6. /9F3 SCALE'+. REVISED/ JOB N0. f� spA.1 D 3I� 1;717•' LCA atY /ov/ SHEET / OF NEF2r�r� t /oV� 3oHG I7>" AVL, WATER ENCOUNTERED AT /20 " ELEV. DESIGN CALCULATIONS NUMBER OF BEDROOMS GARBAGE DISPOSAL UNIT NO TOTAL ESTIMATED FLOW ( 110 CAL/BR./DAY X _. BR.) 232 GAL/DAY REQUIRED SEPTIC TANK CAPACITY /11, 0 GAJ- ACTUAL ALACTUAL SITE OF SEPTIC TANK 1500 GAL SOIL CLASSIFICATION I DESIGN PERCOLATION RATE 5 5 MIN./IN. EFFLUENT LOADING RATEr4I4_ GAL/DAY/S.F'. LEACHING AREA a SO. FT. i"Xiy%*��YSXi 1104"Z_,} re? LkA"G CAPACITY (AREA X RATE) Z GAL/DAY Y� YG RESERVE LEACHING CAPACITY f>""GAL/DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM 70 D.E.P. TITLE 5 AND THE TOWN OF VtiR "Ct/1-iH L RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6' OF FINISHED GRADE 3. ALL COMPONENTS OF THE SANITARY. SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL/-' BE MORTARED IN PLACE, 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH' DEEDED OR ZORiAG REGULATIONS. OWNER / APPLICANT 15 TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY. EXCAVATION CONTRACTOR IS TO CALL 'DIG -SAFE' AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. %CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SRE ANY VARIATION 1S TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8. PARCEL IS IN FLOOD ZONE 9. LOT IS SHOWN ON ASSESSORS MAPS. AS PARCEL a 10. EXISTING SEPTICS ARE TO BE PUMPED AND BACKFILLED. res " 6l APPROVED: BOARD OF HEALTH /ATE AGg&T 0 1998 SWEETSER ENGINEERING I I CC, L �y V y H � i✓� 1 ��J Y T y � \ Y� � �V (� F. PROPOSED SEPTIC DESIGN FOR l'-45 - l'-45 Dt! hlr;C PROJECT LOCATION /Q r�!lt 3 7)I' I 'Ir So() yrW P-1 oEJ7 N . SWEETSER ENGINEERING 235 GREAT WESTERN ROAD _ - P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 DATE /o`!6. /9F3 SCALE'+. REVISED/ JOB N0. f� LOCATION MAP REVISED SHEET / OF 0 1998 SWEETSER ENGINEERING I I