HomeMy WebLinkAbout13 Park Circle Site Plan 245.8' ACCESS COVERS TO WITHIN 6" OF FIN. GRADE PRECAST H-10 RISERS (TYP.) Vo SYSTEM PROFILE (NOT TO SCALE) -1 2" PEASTONE OR GEOTEXTILE 1 - FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE J MINIMUM .75'+OF COVER OVER PRECAST 1 2% SLOPE REQUIRED OVER SYSTEM 145.0" 45.5.1 NOTE: MIN. WALL THICKNESS 2" LOCKS OR PRECAST RISERS 4"OSCH40 PVC MORTAR ALL INVERT IN 41.5' PIPES LEVEL 1ST 2' 2' COMPONENTS 2•— ENDS (TMP.) SIDES... U 10"1500 GAL H-10 t4^ ..., TEE SEPTIC TANK TEE 1.87 ' ° 6" MIN. SUMP ®®®��®®®®®® ®f]l�®®®®®®®tel GAS BAFFLE.: ° ° °o? 12" MIN. INT. DIM.®®®® 4' UQ. LEVEL (ACME OR EQUAL) 41.79' 41.62' - 3. • - - -. r• .. , WATERTEST D'BOX FOR LEVELNESS } a°c° `H-20 500 GAL LEACHING CHAMBERS IR ACME PRECAST OR EQUi 1 ALL AROUND DOUBLE WASHED STONE 2' MIN (4) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 4 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 38.00' X 8.83' I COMPACTION. (15.221 [21) (2_5 R SLOPE) (—L% SLOPE) (—L-% % SLOPE) MIN. LEACHING FOUNDATION— 17 —SEPTIC TANK 8' D' BOX 14' FACILITY NO GROUND ATEER TH—FOUND *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM INTERIOR PLUMBING TO BE RE—ROUTED AS NECESSARY LEGEND- EGEND99— 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[991— PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 Route 6 TEST HOLE 2> SLOPE OF GROUND �QY UTILITY POLE y� Y FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER. DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 3/26/15 PERC. RATE _ < 8 MIN/INCH CLASS I SOILS 4 ELEV. 0" 45.5' A SL 10YR 4/2 11" B SL 27" 1OYR 6/3 43.3' CT SiL 50 2.5Y 7/2 41.3' " PERC C2 FS 2.5Y 7/6 120" 135_5' NO GROUNDWATER ENCOUNTERED DICE #15-005 2 NOTE. LOT LINES ARE 100'+ FROM ANY PROPOSED SEP77C COMPONENTS Scale: 1 "= 20' 0 10 20 30 40 `G FE=T IV 4 "GROUNDWATER EXPECTED AT EL 31.0 NOTES 1. DATUM IS NAVE) 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-24 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 24" OAK 7/ \ \ SUPPORT GARAGE AS NECESSARY \ TO PREVENT UNDERMINING \ \ DURING SEP77C INSTALLATION O� t �O 01 o4'11 3 PROPOSED ADDITION I �I I 44 I BENCHMARK I0.' I (/� CENTER OF BASIN I e 3130,> - DATE L7 r..auY3 Health Depart.:.z::a__ Date ,7gu 17- 4,r. S. LOCUS MAP NOT TO SCALE ASSESSORS MAP 83 PARCEL 2 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED /x•'5.1 DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (38 + 8.83) 2 (.66) = 124 GPD BOTTOM 38 x 8.83 (.66) = 221 GPD TOTAL: 522 S.F. 345 GPD USE (4) H-20 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 2' STONE ALL AROUND MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 13 PARK CIRCLE WEST YARMOUTH, MA PREPARED FOR LEE ROBERTS DATE: MARCH 30, 2015 I off 508-362-4541 fax 508-362-9880 downcope.com down capeengineering, inc. civil engineers land surveyors 939 Moin Street ( Rte 6A) YARMOUTHPORT MA 02675 15-005 ROBERTS.DWG xit 7 = Route 6 Yarmouth m ~ Campground Q a 2 Locu'^JQ h V s i 04 `° s I\ N `f Sams able y99�i�s, Ronicipol 'Po C'a Airport COMM %, Electric Cocheset LOCUS MAP NOT TO SCALE ASSESSORS MAP 83 PARCEL 2 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED /x•'5.1 DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (38 + 8.83) 2 (.66) = 124 GPD BOTTOM 38 x 8.83 (.66) = 221 GPD TOTAL: 522 S.F. 345 GPD USE (4) H-20 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 2' STONE ALL AROUND MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 13 PARK CIRCLE WEST YARMOUTH, MA PREPARED FOR LEE ROBERTS DATE: MARCH 30, 2015 I off 508-362-4541 fax 508-362-9880 downcope.com down capeengineering, inc. civil engineers land surveyors 939 Moin Street ( Rte 6A) YARMOUTHPORT MA 02675 15-005 ROBERTS.DWG