HomeMy WebLinkAbout25.320 - Title 5 Site Plan (2)TOP FNDN. AT EL. 10.3'
6.6
SYSTEM PROFILE
ACCESS COVER TO WITHIN 6" OF FIN GRADE (NOT TO SCALE)
2% SLOPE REQUIRED OVER SYSTEM MIN. FI- R-5'
*NOTE: 2" DROP BETWEEN
. INLET INVERT AND OUTLET USE CULTEC FILTER FABRIC PER MANUFA--TURERS SPECS
RUN PIPE LEVEL OVER ENTIRE LEACHING FACILITY
/FOR FIRST 2' 4 PROPOSED 1500 -
GALLON SEPTIC 7 67' 0 e o 0 0 0 o e o'o e a o 0 0 0 0 0 0cfl-7�71
7 O'
7.92 TANK (H- 10 ) GAS 7 3 0�7 00 0
(_% SLOPE)
DEPTH OF FLOW 4 -
TEE SIZES:
INLET DEPTH 10
OUTLET DEPTH = 144
FOUNDATION -
BAFFLE 7,55' �� 8
6" CRUSHED STONE OR MECHANICAL 6" SUMP REO'D 3/4" TO 1 1/2" DOUBLE WASHES: STONE
COMPACTION. (15.221 [2])
(-L% SLOPE) (� % SLOPE)
10' - SEPTIC TANK
BENCHMARK - TOP OF LAND COURT BOUND
ELEVATION = 8.50 (NGVD)
+ 7.4
1'A)?KWOOD 7.6
7 . ROAD
__ RELOCATE UTIL.
EDGE OFDIRT POLE AS NEC
.
ROAD
m
PROP. G
DRIVE. ..._
0
PROP RETAINING WALL y
DESIGN BY OTHERS •4• / b
MAX ELEV. 8.0', DESCENDING TO
EL. 6.0 AT BOTH ENDS + 5.2
+ 5.2 za
x
Qti
EXIST
DWELL
TOP FNDN = 5.8'` 1y
a
i
If
/ -r-( 4.9
PROP. DWELL.!
TOP FNDN - 10.3' i ,+ 2'
.2')
16 '
1 PROP. DECK J
+ 5.4'
1 N
L D % JOA RESERVE
7386+/- SO. FT, 468 SF
0.17+/- ACRES _ N
TH
14.
12'
70
VARIANCES REQUESTED:
15.405 1i: REQUEST REDUCTION IN GROUNDWATER SEPARATION, 5'
TO 4'
15.405 10: REQUEST REDUCTION IN SETBACK FOR RESERVE SAS
TO PROPERTY LINE, 10' TO 8'
4PROVIDE APPRC` 87' OF 40 MIL LINER,
5' OFF LEACHING FACILITY, AS SHOWN.
TOP ELEVATION AT 7.7', BOTTOM AT
q EL. 3.7'
.4 \HiGH POINT (EL 8)
rEXIST.
GRAVEL PARKING AREA
O BE REMOVED)
5' REMOVAL OF UNSUITABLE SOIL REQUIRED
AROUND PERIMETER OF LEACHING FACILITY,
DOWN TO SUITABLE SOIL LAYER. REPLACE
WITH CLEAN MED. SAND. ENGINEER TO
INSPECT AND CERTIFY REMOVAL
EXIST
DWELL
ZA / TOP FNDN = 9.5
f \ EXIST. DWELL.
co
TOP FNDN - 6.9'
+
8.2
PROVIDE SWALES AS NECESSARY TO
PREVENT RUN-OFF ONTO NEIGHBORS'
PROPERTIES
LEACI ING
FAC IL TY
TEST HOLE LOGS
ENGINEER: RICK JUDD, RS
WITNESS: AMY VON HONE, RS
DATE: 12/7/00
PERC. RATE = < 2 MIN/INCH
CLASS SOILS P#
ELEV.
Orr 66_6,
4' A/E
LES
6" 1OYR 4/2
Bw
LS
10YR 4/6
30" 4.10'
USE ADJ. WATER AT EL. 3.0' NGVD *
WELL: MIW 29
ZONE: A
ADJ: 2.6'
+ USING V ADJUSTMENT DUE TO
LOCAL CONDITIONS
®'
C
FS
I obs, woter 1 2.02'
2.5Y 6/4
SEPTIC _ DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED
DESIGN FLOvV: 3- BEDROOMS (110 GPD) 330 GPD
GFu DESIGN FLOW
SEPTIC TANK: 330 GPD ( 2 ) = 660
USF A GALLON SEPTIC TANK
LEACHING:
SIDES: - N/A
BOTTOM. 5 x 30 (.74) 333
TOTAL: 450 S F 333 GPD
USE 2 ROWS OF (3) C4 CULTEC FIELDDRAIN PANELS
WITH 3.5' STONE AT SIDES AND 3' AT ENDS
LEGEND
100.0 PROPOSED SPOT ELEVATION
100x0 EXISTING SPOT ELEVATION
100 PROPOSED CONTOUR
--
100- EXISTING CONTOUR
BOARD OF HEALTH
MA
APPROVED DATE
off 508-362-4541
lax 508 362-9880
down cape engineering, inc.
CIVIL ENGINEERS
LAND SURVEYORS
939 main St. yarmouth, rock 02675
-0.4
I
1 I C�01CK RD'
ty
I �
RD.
I PARK
v
n �� LOCUS
A
A
GIIBERT ST.
A
LOCATION MAP NTS
ASSESSORS MAP 25
PARCEL 320
FLOOD ZONE: B & A9
EL 10
ZONING: R-25
C-i
FRONT: 30'
Fns;
SIDE: 15'
EL 9 9'ACCESS
EL. -9-9--'l
MINIMUM 75' OF COVER OVER
PRECAST/--
COVER (WATERTIGHT) TO
WITHIN 6" OF FIN GRADE
2% SLOPE REQUIRED OVER SYSTEM MIN. FI- R-5'
*NOTE: 2" DROP BETWEEN
. INLET INVERT AND OUTLET USE CULTEC FILTER FABRIC PER MANUFA--TURERS SPECS
RUN PIPE LEVEL OVER ENTIRE LEACHING FACILITY
/FOR FIRST 2' 4 PROPOSED 1500 -
GALLON SEPTIC 7 67' 0 e o 0 0 0 o e o'o e a o 0 0 0 0 0 0cfl-7�71
7 O'
7.92 TANK (H- 10 ) GAS 7 3 0�7 00 0
(_% SLOPE)
DEPTH OF FLOW 4 -
TEE SIZES:
INLET DEPTH 10
OUTLET DEPTH = 144
FOUNDATION -
BAFFLE 7,55' �� 8
6" CRUSHED STONE OR MECHANICAL 6" SUMP REO'D 3/4" TO 1 1/2" DOUBLE WASHES: STONE
COMPACTION. (15.221 [2])
(-L% SLOPE) (� % SLOPE)
10' - SEPTIC TANK
BENCHMARK - TOP OF LAND COURT BOUND
ELEVATION = 8.50 (NGVD)
+ 7.4
1'A)?KWOOD 7.6
7 . ROAD
__ RELOCATE UTIL.
EDGE OFDIRT POLE AS NEC
.
ROAD
m
PROP. G
DRIVE. ..._
0
PROP RETAINING WALL y
DESIGN BY OTHERS •4• / b
MAX ELEV. 8.0', DESCENDING TO
EL. 6.0 AT BOTH ENDS + 5.2
+ 5.2 za
x
Qti
EXIST
DWELL
TOP FNDN = 5.8'` 1y
a
i
If
/ -r-( 4.9
PROP. DWELL.!
TOP FNDN - 10.3' i ,+ 2'
.2')
16 '
1 PROP. DECK J
+ 5.4'
1 N
L D % JOA RESERVE
7386+/- SO. FT, 468 SF
0.17+/- ACRES _ N
TH
14.
12'
70
VARIANCES REQUESTED:
15.405 1i: REQUEST REDUCTION IN GROUNDWATER SEPARATION, 5'
TO 4'
15.405 10: REQUEST REDUCTION IN SETBACK FOR RESERVE SAS
TO PROPERTY LINE, 10' TO 8'
4PROVIDE APPRC` 87' OF 40 MIL LINER,
5' OFF LEACHING FACILITY, AS SHOWN.
TOP ELEVATION AT 7.7', BOTTOM AT
q EL. 3.7'
.4 \HiGH POINT (EL 8)
rEXIST.
GRAVEL PARKING AREA
O BE REMOVED)
5' REMOVAL OF UNSUITABLE SOIL REQUIRED
AROUND PERIMETER OF LEACHING FACILITY,
DOWN TO SUITABLE SOIL LAYER. REPLACE
WITH CLEAN MED. SAND. ENGINEER TO
INSPECT AND CERTIFY REMOVAL
EXIST
DWELL
ZA / TOP FNDN = 9.5
f \ EXIST. DWELL.
co
TOP FNDN - 6.9'
+
8.2
PROVIDE SWALES AS NECESSARY TO
PREVENT RUN-OFF ONTO NEIGHBORS'
PROPERTIES
LEACI ING
FAC IL TY
TEST HOLE LOGS
ENGINEER: RICK JUDD, RS
WITNESS: AMY VON HONE, RS
DATE: 12/7/00
PERC. RATE = < 2 MIN/INCH
CLASS SOILS P#
ELEV.
Orr 66_6,
4' A/E
LES
6" 1OYR 4/2
Bw
LS
10YR 4/6
30" 4.10'
USE ADJ. WATER AT EL. 3.0' NGVD *
WELL: MIW 29
ZONE: A
ADJ: 2.6'
+ USING V ADJUSTMENT DUE TO
LOCAL CONDITIONS
®'
C
FS
I obs, woter 1 2.02'
2.5Y 6/4
SEPTIC _ DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED
DESIGN FLOvV: 3- BEDROOMS (110 GPD) 330 GPD
GFu DESIGN FLOW
SEPTIC TANK: 330 GPD ( 2 ) = 660
USF A GALLON SEPTIC TANK
LEACHING:
SIDES: - N/A
BOTTOM. 5 x 30 (.74) 333
TOTAL: 450 S F 333 GPD
USE 2 ROWS OF (3) C4 CULTEC FIELDDRAIN PANELS
WITH 3.5' STONE AT SIDES AND 3' AT ENDS
LEGEND
100.0 PROPOSED SPOT ELEVATION
100x0 EXISTING SPOT ELEVATION
100 PROPOSED CONTOUR
--
100- EXISTING CONTOUR
BOARD OF HEALTH
MA
APPROVED DATE
off 508-362-4541
lax 508 362-9880
down cape engineering, inc.
CIVIL ENGINEERS
LAND SURVEYORS
939 main St. yarmouth, rock 02675
-0.4
I
1 I C�01CK RD'
ty
I �
RD.
I PARK
v
n �� LOCUS
A
A
GIIBERT ST.
A
LOCATION MAP NTS
ASSESSORS MAP 25
PARCEL 320
FLOOD ZONE: B & A9
EL 10
ZONING: R-25
C-i
FRONT: 30'
Fns;
SIDE: 15'
REAR: 20'
MAX LOT COVERAGE:
25%
LOT COVERAGE:
EXIST. DWELL. 1061.5 SF
(14.3%)
PROP. DWELL. 1064 SF (14.4%)
PROP. DECK 293 SF
(3.9%)
NOTES:
1. DATUM IS NGVD
2. MUNICIPAL WATER IS _EXISTING
3. Yi'v1rv!UM PIPE F'IICH i0 BE 1/8" PER FUO -Ir.
4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10
5. PIPE JOINTS TO BE MADE WATERTIGHT.
6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS.
ENVIRONMENTAL CODE TITLE V.
7, THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT
TO BE USED FOR ANY OTHER PURPOSE.
8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC.
9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT
INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED
FROM BOARD OF HEALTH.
10. PUMP & REMOVE (OR FILL W/CLEAN SAND) EXISTING SEPTIC SYSTEM
TI TLE 5 SITE PLAN
OF #9 PARKWOOD ROAD
IN THE TOWN OF:
(SOUTH) YARMOUTH
PREPARED FOR: ANTHONY ROLLAS
20 _ 0 20 40 60
SCALE: 1" = 20' DATE: JANUARY 3, 2001 1
REV. 3/20/01 (HSE) -
REV. 4/10/01 (HSE) K G
REV. 4/11/01 (CANT)
P. L. S.
-DATE
T -a
_
e
s
7411 -
C-i
CG
O
Fns;