Loading...
HomeMy WebLinkAbout25.320 - Title 5 Site Plan6,6 TOP FNDN. AT EL. 10.3' SYSTEM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) /�' ACCESS COVER (WATERTIGHT) TO 9.9' MINIMUM .75' OF COVER OVER PRECAST{ WITHIN 6" OF FIN GRADE •NOTE: 2" DROP BETWEEN INLET INVERT AND OUTLET PROPOSED 1500 2% SLOPE REQUIRED OVER SYSTEM MIN FI R S' USE CULTEC FILTER FABRIC PER MANUFACTURERS SPECS RUN PIPE LEVEL OVER ENTIRE LEACHING FACILITY FOR FIRST 2' 7.92' 11 0 GALLON SEPTIC 7.67' 3 Z TANK (H- 110 ) GAS 7.38' BAFFLE 7.55' (2_7 SLOPE) �6" CRUSHED STONE OR MECHANICAL 6" SUMP REQ'p COMPACTION. (15.221 [23) DEPTH OF FLOW = 4_ ( 1 % SLOPE) { % SLOPE) TEE SIZES: INLET DEPTH OUTLET DEPTH - 14" FOUNDATION- 10' SEPTIC TANK BENCHMARK -- TOP OF LAND COURT BOUND ELEVATION = 8.50 (NGVD) �'ARKiY00D 7.6 + 7.4 7- U ROAD RELOCATE UTIL. EDGE OF DIRT POLE AS NEC. ROAD PROP. DRIVE. PROP RETAINING WALL .r"`� 5.. -- MAX ELEV. 8.0', DESCENDING TO EL. 6.0 AT BOTH ENDS +5.2 �- 5.2 EXIST DWELL W TOP FNDN 5.8" 4.9 PROP. DWELL. TOP FNDN = 10.3'(V L0 34\A 7386+/- SO. FT. 0.17+/- ACRES 40, )0-319 0 N i _�A 1 76 1 OP PROP, DECK I L � 8 14. `r7.1 A 12' •"/ -' •- I ./ a l WVQtC VVAJfICU J17JIVC VARIANCES REQUESTED: 15.405 11: REQUEST REDUCTION IN GROUNDWATER SEPARATION, 5' TO 4' 15.405 to: REQUEST REDUCTION IN SETBACK FOR RESERVE SAS TO PROPERTY LINE. 10' TO 8' PROVIDE APPROX. 87' OF 40 MIL LINER. 5' OFF LEACHING FACILITY, AS SHOWN. TOP ELEVATION AT 7.7', BOTTOM AT EL. 3.7 -----HIGH POINT (EL 8) -EXIST. GRAVEL PARKING AREA (TO BE REMOVED) �.--- 5' REMOVAL OF UNSUITABLE SOiI REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN "f0 SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND. ENGINEER TO INSPECT AND CERTIFY REMOVAL EXIST DWELL TOP FNDN 9.5' LEACHING FACILITY USE ADJ. WATER AT EL. 3.0' NGVD' PROVIDE SWALES AS NECESSARY TO PREVENT RUN-OFF ONTO NEIGHBORS' PROPERTIES �N EXIST. DWELL. CONSULT MANUFACTURER'S SPECS FOR TOP FNDN - 6.9' DETAILED DESCRIPTIONS AND INSTALLATION- co ENSURE ALL WATER DIRECTED AWAY FROM WALL. EL. 8.0' (HIGHEST PISA 11 STANDARD ELEVATION) UNIT (OR EQUAL) '/- PROP. FILTER CLOTH +93 _H 12" /' PROVIDE 12" OF WELL GRADED WASHED + 6.2 _.`. / STONE BEHIND MASONRY BLOCK UNITS .. �� PROVIDE TRENCH 12" DEEP AND 24' WIDE. SHAPE SLOPE TO ALLOW FOR 12- DRAINAGE MATERIAL BEHIND THE WALL RETAINING WALL DETAIL (NTS) WELL: M!W 29 ZONE: A ADJ., 2.6' USING V ADJUSTMENT DUE TO LOCAL CONDITIONS TEST HOLE LOGS ENGINEER: RICK JUDD, RS WITNESS: AMY VON HONE, RS DATE: 12/7/00 PERC. RATE =_< 2 MIN/INCH CLASS SOILS " P{/ ELEV. 0„ A/E LFS 6" 10YR 4/2 Bw LS 10YR 4/6 30" 4.10' C FS obs. woter 2.5Y 6/4 cEPTIC DESIGN: (GARFAGE DISPOSER IS NOT ALLOWED_ �EsIGN FLOW: 3_ BEDROOMS (1?0_GPD) _ ;i30 GPD SE A 330 GPD DESIGN FLOW `Q' HC TANK: 330 - GPD (2 ) = 660 ..L. USE A i500 GALLON SEPTIC TANK _LEACHING: SIDES: -- N/A _ 15 x 30 (.74) 3 t>0'TOM: _ = 333 "01AL: 450 S.F. 333 GPD -- LSE 2 ROWS OF (3) C4 CULTEC FIELOD RAIN PANELS V'AT1 3.5' STONE AT SIDES AND 3' AT ENDS LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION UO]PROPOSED CONTOUR 100 - EXISTING CONTOUR BOARD OF HEALTH 7371/ A17PROVED DATE MA o/l 508-162-4541 fox 508 362-9680 down cape engineering, inc, CIVIL ENGINEERS LAND SURVEY RS 939 main St. yarmouth, Ina 02675 2.02' I I COROICK R0. m 1 s I RARKNOOp RD oIY z LOCUS A N OILBERI ST. " A LOCATION MAP NTS ASSESSORS MAP 25 PARCEL 320 FLOOD ZONE: A9 EL 10 ZONING: R--25 FRONT: 30' SIDE: 15' REAR: 20' MAX LOT COVERAGE: 25% LOT COVERAGE: EXIST, DWELL. 1061.5 SF (14.37) PROP. DWELL. 1064 SF (14.4%� PROP. DECK 293 SF (3.9% -0.4 NOTES: 1. DATUM IS NGVD 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 / 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. PUMP & REMOVE (OR FILL W/CLEAN SAND) EXISTING SEPTIC SYSTEM TITLE 5 SITE PLAN OF #9 PARKWOOD ROAD IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: ANTHONY ROLLAS 20 0 20 40 60 SCALE: 1„ = 20' DATE: JANUARY 3, 2001 REV. 3/20/01 (HSE) _ REV. 4/10/01 REV. 4/11/01 C�'Pt � Ll u �� EV. 5/30/01 IVALL) .jUP,l 2 0 2001 j �fSo i. DATE