HomeMy WebLinkAbout25.126 - Title 5 Site Plan (2)SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK CRAWLSPACE LEACHING: PERIMETER: 121 LF x 0.83 x 0.74 = 74 GPD BOTTOM AREA: 520 SF (0.74) =384 GPD TOTAL: 618 S.F. 458 GPD USE 7 H-20 HIGH CAPACITY INFILTRATORS IN CONFIGURATION SHOWN (SEE DETAIL) PROVIDE WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 12.0' MINIMUM .75'+OF COVER OVER PRECAE PRECAST H-10 RISERS (TYP.) z•0 ri SYSTEM PROFILE (NOT TO SCALE) 400SCH40 PVC PIPES LEVEL 1ST 2' ALL SYSTEM COMPONENTS SHALL BE NOTES MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 1. DATUM IS NGVD 2. MUNICIPAL WATER IS EXISTING PROVIDE INSPECTION PORT TO WITHIN 3" OF FINAL GRADE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 2R SLOPE REQUIRED OVER SYSTEM / 11' - 12' 2" PEASTONE OR GEOTEXTILE FILTER FAB�Ib OVER STONE V io 14„ 10,06' TEE 1500 GAL H-10 TEE SEPTIC TANK 9.61 ° 6" MIN. SUMP 4' L10. LEVEL °0O0°o°o°o°a°o o° GAS BAFFLE° °o°o°o°o°o°o o° 12" MIN. INT. DIM. o ACME OR EOUAL ° .0 0_ ° 9_53' 9.78' ° 9.61'$ 0.e3' 00 0 0 0 0 0 0 0 0 0 o c 0 0 0 00 0 00 00 00 00 00 00 o0 c 0000000 00 0 0 0 00„0„0„0„0, HIGH CAPACITY - INFILTRATORS 11�1_ 6" CRUSHED STONE OR MECHANICAL 3/4" TO 1 1/2" DOUBLE WASHED STONE COMPACTION. (15.221 [21) D'BOX TO BE WATER -TESTED FOR LEVELNESS MA q r A ( SLOPE) ( SLOPE) (_1_X SLOPE) APPROVED DATE BOARD OF HEALTH FOUNDATION- 11 -SEPTIC TANK 3' D' BOX 10' - LEGEND- EGEND99 99- EXISTING CONTOUR + 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 99 PROPOSED SPOT EL. THI PROP. I -''1 --+ 9.9 TEST HOLE 2�7 SLOPE OF GROUND CQ-) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAN9NG 02-340 NOTE: FLOOOZONE DESIGN FOUNDATION BY OTHERS. FINAL GRADING TO BE IN ACCORDANCE WITH FEMA FLOODZONE REGULATIONS SAS DETAIL 1"=20' 0 N LOT 11 \+ 13,111± SC. rt. _0.301 ACES \ r TH 1 1 C^ \ `012'lNc � Y\ \� \ 10.0 y �n00 `I NF yy 10. R 2' . 1 + 10.4 PROP. DWEWNG TOP FNDN. ELEV. 13.0 METER PIT + 10.3 + 10.3 GARAGE NOTE: INVERT INTO SAS IS BELOW THE CRAWLSPACE FLOOR ELEVATION 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 10.0' 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 1-a8.7' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND 5.0' PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. USE ADJ. GROUNDWATER AT EL. 3.7'* 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED _LEACHING LEACHING FACILITY. FACILITY - _ - - 12. EXISTING SEPTIC SYSTEM SHALL BE PUMPED AND REMOVED *NOTE: OBSERVED GROUNDWATER ELEVATIONS IN ALL 13. ALL ROOF RUN-OFF TO BE INFILTRATED INTO TEST HOLES WERE WITHIN 3 INCHES. GROUNDWATER IN THIS AREA DRYWELLS CAN BE INFERRED TO BE AFFECTED BY NEARBY NANTUCKET SOUND (GROUNDWATER ADJUSTMENT DATA FOR 2002 HOLES ARE NOT INDICATIVE OF REALISTIC HIGH GROUNDWATER ELEVATIONS) ELEV. s 10.0 FILL 10.5' 0" , za.00 FILL o i 5" t 9.1 PROP. I -''1 --+ 9.9 J DECK I Ila , I SL n I -------- fo.s EB FND I 1 TH 2 2.5Y 7/1 10YR 2/1 i ��Po/ N EXIST. 4" LFS o, IQ E FND + 9J 123.08'} I + 10.3 + 10.3 GARAGE NOTE: INVERT INTO SAS IS BELOW THE CRAWLSPACE FLOOR ELEVATION 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 10.0' 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 1-a8.7' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND 5.0' PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. USE ADJ. GROUNDWATER AT EL. 3.7'* 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED _LEACHING LEACHING FACILITY. FACILITY - _ - - 12. EXISTING SEPTIC SYSTEM SHALL BE PUMPED AND REMOVED *NOTE: OBSERVED GROUNDWATER ELEVATIONS IN ALL 13. ALL ROOF RUN-OFF TO BE INFILTRATED INTO TEST HOLES WERE WITHIN 3 INCHES. GROUNDWATER IN THIS AREA DRYWELLS CAN BE INFERRED TO BE AFFECTED BY NEARBY NANTUCKET SOUND (GROUNDWATER ADJUSTMENT DATA FOR 2002 HOLES ARE NOT INDICATIVE OF REALISTIC HIGH GROUNDWATER ELEVATIONS) ELEV. s 10.0 FILL 10.5' 0" (NGVD) 9.5' FILL 2" FILL 5" t 9.1 A -''1 --+ 9.9 N I I PROPOSED Ila , I SL LS EB FND I DRIVE. TH 2 2.5Y 7/1 10YR 2/1 7" 4" LFS 28" IQ E - ' � E I LS PERC LS O 15" 10YR 5/2 9" 10YR 5/2 Bw I > ry 170 LS LS 28" 1OYR 5/6 " 1OYR 5/6 jo Cl " C1 - e LFS w LFS C) 2.5Y 6/4 46" 2.5Y 6/4 O I W 1 9.3 q ui+ I - I I I EV co '3 3 PROVIDE APPROX. 60' OF 40 MIL LINER AT 5' OFF PORTION ,- R I OF PERIMETER OF SAS. TOP + 10.1 I AT ELEV. 10, BOTTOM AT EL. ONC. BOUND 6 I F 9.4 11.6 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) ZONING SUMMARY ZONING DISTRICT: R-25 MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. LOT COVERAGE: 25% PROP. LOT COVERAGE: 24.3% (INCLUDES ALL DECK AND ACCESS STAIRS) OWNER OF RECORD FRANCIS AND DIANNE CLORAN 36 NOTTINGHAM DRIVE KINGSTON, MA REFERENCES CTF 138794 LCP 18413-D (LOT 11) TEST HOLE LOGS ENGINEER: RICK JUDD, RS WITNESS: AMY VON HONE, RS DATE: 11/20/02 PERC. RATE = < 2 M'N/INCH CLASS ---i-SOILS ELEV ELEV O" FILL 10.5' 0" A 9.5' FILL 2" FILL 5" A 6 A SL LS FS 1OYR 2/1 2.5Y 7/1 10YR 2/1 7" 4" LFS 28" 2.5Y 5/6 E E LS PERC LS C 15" 10YR 5/2 9" 10YR 5/2 Bw Bw LS LS 28" 1OYR 5/6 8.2' 25" 1OYR 5/6 7.4' Cl " C1 - PERC LFS LFS 5B" 2.5Y 6/4 46" 2.5Y 6/4 ADJ WATER C2 4.8, ,�gTR 5.0' OBS. WATER 96 _FS 2.5 " QB� 2.75 5Y 6/6 104" 2.5Y 6/3 1.8' 92" 2. 1.8' GROUNDWATER ADJUSTMENT DATA: WELL: MIW 29 ZONE: A ADJ: 2.3' LOCUS NOT TO SCALI ASSESSORS M LOCUS IS WTI A9 ELEV. 10 1 ON COMMUNIT JULY 2, 1992 TEST HOLE ENGINEER: ARNE H. OJ, WITNESS: AMY VON HOI DATE: 5/14/09 PERC. RATE _ < 2 M CLASS I SOILS 3 ELEV. 0" 10.1' 4" FILL A SL 10YR 2/1 6 E FS 12" 2.5Y 7/1 _ B LFS 28" 2.5Y 5/6 7.7' PERC M1 C v1 LFS JwATE 3.7' 90" 2.6' 2.5Y 5/6 120" 0_1' 1 T I T L kE GROUNDWATER ADJUSTM WELL: MIW 29 ZONE: A ADJ: 1.1' 60 PARKWOOD SOUTH YARM PREPARED FOR M/M FRANCIS C JULY 15, 2009 varmouth Health Department AUGUST 5, 2009 (SEF APPROVED REV DEC. 16, 2009 (LES' _G_._w. _ 0 10 20 30 40 OF 04gS DP.NIEI_ ��m A. off 50 OJALA N I fax 50 No. 40980 down( down cape engineej '°Sr- SUR civil eY land su DATE DANIEL A. OJALA, P.E., P.L.S. 939 Main Street ( Rte YARMOUTHPORT MA